Explosion and flame-proof single phase electric motors

Similar documents
Explosion and flame-proof cast iron electric motors

VALIADIS S.A. HELLENIC MOTORS

Standard cast iron Motor

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

BFG range BFGC range BFN range

BFG range BFGC range BFN range

champion series motors

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

: B3; B5; B14; B34; B35; V1

Low Voltage Induction Motors

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Aluminium Frame Motors Improved Efficiency EFF2

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

SINGLE PHASE TEFC CAGE MOTORS

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

1LG0 Low-voltage Motors

W22 Medium Voltage Motors TEFC - Severe Duty

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw

NEMA explosion-proof AC motors. Individual solutions are our standard

M3000 Motors for Hazardous Areas. Low Voltage Non-sparking Motors Ex na, EEx na

10 Load and Motor Switchgear

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

Type - KF FLAME-PROOF MOTOR FRAME 80 TO 355 Ex d. A Regal Brand.

W22 NEMA Brake Motors - NEMA Premium

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact:

Series E4F E5F

ELK PRODUCT CATALOGUE. elkmotor.com.tr

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Motors for hazardous areas New cast iron motors in sizes

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

xplosion Proof Motors hoyermotors.com Explosion Proof

HAIE2 -Efficiency and reliability for industry

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

End Suction Range MARCH 2018

CE Marking. Number of poles. Core Length. Frame size

Energy Saving Three Phase Motors

Flameproof Enclosures

This catalogue also includes cooling medium pumps of the types DKP and EKP.

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request

PLS Open Drip Proof three-phase asynchronous motors. General information

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Technical Documentation

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC

Unused flameproof threads for cable glands have to be closed with certified plugs.

MVSI. Technical features

Flameproof DC motors for hazardous locations. C Series DC motors. Grandezze-Sizes Catalogo Catalogue. Code C-DC-ATEX-7-23-E-11

Low Voltage 3-Phase Induction Motors. Range 0.18kW to 670kW

Low Voltage 3-Phase Induction Motors. Range 0.55kW to 500kW TOTALLY ENCLOSED FAN-COOLED CAST IRON FRAME SERIES AUSTRALIA & NEW ZEALAND

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST

Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

Position Qty. Description Single Price 1 SEV B

Control and Terminal Box Type A21-**-*****

Metric Efficient Line Cast-iron IEC Motors

Q max (see specifications table)

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

Severe Duty is Standard with WEG W22 motors

SERIES R - MD MOR & GOR

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Factor 1) Modulating torque 4) [Nm]

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Helical Gear Motors BEGE Type G & M. Your drive, our (trans)mission. BEGE Power Transmission

Modular Explosion Proof Brakes. IECLine rev 0

For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h

A good connection. International approvals.

IECEx Certificate of Conformity Annexe

ELECTRIC MULTI-TURN ACTUATORS for valve automation in the oil & gas industry with high torque requirements

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

LSES high efficiency three-phase asynchronous motors. General information

M-0. M-0... series control, monitoring and signalling devices. Ex e

High voltage flameproof induction motors The simplest solution for hazardous environments

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

Solenoid Operator 0516 / 1216

THREE PHASE ASYNCHRONOUS MOTORS. MS/S Series (frame Aluminum) TC Series (frame Cast iron) Y Series (frame Cast iron)

MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

10 Load and Motor Switchgear

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

AC MOTORS. Bangalore, India

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Level limit switch Series RF 3000 Selection list

IEC Range Three phase IEC low voltage motors - 56 to 355 frames. Single phase motors - 56 to 100 frames Capacitor Run Capacitor Start and Run

IP66 GSW GEAR BOX MOTOR SERIES

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE

Transcription:

Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz

Types of mounting B3 V9 B5 B14 B6 B9 B3 / B5 V5 B3 / B14 B15 V1 B7 V18 V1 / V5 V8 V18 / V5 V6 B8 V3 / V6 V3 V19 V19 / V6

General characteristics Introduction: This documentation describes the main technical characteristics of our explosion-proof motors. They have been designed according to ATEX N. 94/9/CE that concerns the essential safety characteristics of equipments intended to be used in potentially explosive atmospheres. The suitability of our explosion proof motors, to the essential safety characteristics demanded by the ATEX, is shown by the CE certificates issued by the CESI, notified body N. 0722: CESI 06 ATEX 059 IIB and CESI 06 ATEX 060 IIC. Definition: An explosion and flame proof motor Ex-d, Ex-de is a rotating machine which can work in an environment with the presence of gases and/or explosive or inflammable fumes without causing internal damage to the motor. It is in fact: Explosion-proof: its housing neither cracks nor explodes in case of an inward short circuit. Flame-proof: it doesn t allow the exit of gases and flame from the motor when the ambient temperature is critical. Introduction: Our explosion-proof motors Ex-d, Ex-de have been designed according to European standard Cenelec EN 60079-:2006; EN 60079-1:2004; EN 61241-1:2004; EN 61241-0:2006 and, for this reason, they are suitable for hazardous areas as per CEI 64-2 - EN 60079-10.14.17 standard. Explosion groups: Our motors have been certified for explosion group IIA - IIB - IIC and reproduce the following identification marks: GAS : zone 1 e 2 II 2G Ex-d (de) IIB (IIC) The standard EN 60079-0:2006 and EN 60079-1:2004 state the type of gases and vapours included in each explosion group (see the list in the bottom page). Ex-de motors = flameproof enclosure, d for motor frame and increased safety and e for terminal box. DUST: zone 21 e 22 II 2D IP66 T 85 C, T 100 C, T 135 C, T 155 C according with standard EN 50281-1-1. Temperature classes: Our motors are certified for the temperature classes T3 - T4 - T5 (some T6). The ATEX standard settles the correlation between temperature class and maximum motor surface temperature, according to the following table: Main characteristics: - size 56 to 160mm - housing, shields and terminal box in cast iron - standard mechanical protection IP 55 - fan cover protection IP 2x - the cooling fan is in non-sparking synthetical material up to 160 - paint RAL 5010 - screws: nickelled or cadmied - stainless steel nameplate - ball bearings type ZZ on both sides. Temperature class Maximum surface temperature ( C) T1 450 T2 300 T3 200 T4 135 T5 100 T6 85 Terminal box: It is located on the top with cable entry on NDE and can be rotated through 90. Standard motors have 2 cable entries with conical thread GAS GK UNI 6125 or Metric type thread. Motors with either space heaters, Clixon or PTC thermistors always have an extra cable entry. Voltage and frequency: Motors can be wound up to 660 V, 50 or 60 Hz. According to CEI standard, the rated operating voltage can stand a variation of ± 5% and the rated operating frequency can stand a variation of ± 2%, with the motor operating at the name-plate power. Grounding: Motors are provided with 2 earth screws: one on the terminal box, and one on the housing.

Vibration: Vibration values are within the limits of IEC 60034-14 and ISO 2373 grade standards, measured with half key in accordance with ISO 8821. On request we can supply motors with vibration s value R grade. Noise: Standard noise level agrees with the requirements of IEC 60034-9 and ISO R 1680 standards. Output: The rated output indicated on the name plate applies to continuous duty S1, rated voltage and frequency, to max 40 C ambient temperature and to an altitude of installation up to 1000 metres above sea level. Modifications of the output, due to temperature and altitude changes, are indicated in the following diagrams:

2 Pôles 3000 r.p.m single phase TYPE Rated output Speed Currant Efficiency Power factor Mn Capacity Is / In Ts / Tn T max Weight kw tr/min. A (230V) η % cos γ Nm µf M.N Kg. MAK-M 56-2 0,12 2703 0,97 52,72 0,981 0,42 5 2,35 0,44 1,54 7,2 MAK-M- 63A-2 0,18 2836 1,47 60,23 0,894 0,61 5 3,03 0,41 2,13 10,3 MAK-M- 63B-2 0,25 2834 1,85 65,39 0,891 0,84 6,3 2,95 0,49 1,75 11,3 MAK-M- 71A-2 0,37 2897 2,80 69,01 0,837 1,22 8 3,83 0,38 2,24 15,3 MAK-M- 71B-2 0,55 2912 4,20 69,47 0,819 1,80 12,5 4,27 0,45 2,30 16,3 MAK-M- 80A-2 0,75 2842 5,02 70,89 0,919 2,52 16 3,38 0,37 1,66 22,3 MAK-M- 80B-2 1,1 2810 6,90 77,1 0,884 3,74 20 3,95 0,45 3,63 24,3 MAK-M- 90S-2 1,1 2936 6,89 76,49 0,922 3,58 31 5,73 0,48 3,22 29,4 MAK-M- 90L-2 1,5 2778 9,22 76,11 0,936 5,16 35 3,3 0,67 2,70 32 MAK-M 100LA-2 2,2 2903 13,17 79,41 0,954 7,24 40 2,92 0,36 2,1 45,4 MAK-M 100LB-2 3 2853 18,39 78,05 0,928 10,04 50 3,96 0,55 2,38 46,8 MAK-M- 112M-2 4 2850 25,30 72,04 0,953 13,40 75 4,89 0,6 1,90 56,4 4 Pôles 1500 r.p.m single phase TYPE Rated output Speed Currant Efficiency Power factor Mn Capacity Is / In Ts / Tn T max Weight kw tr/min. A (230V) η % cos γ Nm µf M.N Kg. MAK-M- 56-4 0,09 1310 0,86 51,3 0,885 0,66 5 2,25 0,51 1,8 7,2 MAK-M- 63A-4 0,12 1416 1,20 53,74 0,806 0,81 5 2,37 0,56 2,00 10,3 MAK-M- 63B-4 0,18 1408 1,65 54,59 0,866 1,22 8 2,54 0,57 1,95 11,3 MAK-M 71A-4 0,25 1407 1,85 62,43 0,929 1,70 6,3 2,82 0,43 1,56 15,3 MAK-M- 71B-4 0,37 1391 2,65 64,60 0,937 2,54 8 2,79 0,45 1,43 16,3 MAK-M- 80A-4 0,55 1418 4,12 64,00 0,908 3,70 12,5 2,81 0,42 1,60 23,3 MAK-M- 80B-4 0,75 1415 5,05 73,86 0,875 5,06 14 3,04 0,33 1,89 24,3 MAK-M- 90S-4 1,1 1341 6,40 74,78 0,988 7,83 31 2,5 0,46 1,77 29,4 MAK-M- 90L-4 1,5 1363 9,48 72,72 0,936 10,51 40 2,76 0,35 1,80 32 MAK-M 100LA-4 2 1404 12,47 74,68 0,933 12,47 45 2,85 0,53 2,46 44,4 MAK-M 100LB-4 2,2 1450 12,75 81,45 0,935 14,49 55 4,41 0,20 2,18 47,4 MAK-M 112M-4 3 1406 17,25 79,69 0,951 20,38 55 3,61 0,19 1,82 60,4 6 Pôles 1000 r.p.m single phase TYPE Rated output Speed Currant Efficiency Power factor Mn Capacity Is / In Ts / Tn T max Weight kw tr/min. A (230V) η % cos γ Nm µf M.N Kg. MAK-M 63B-6 0,06 918 0,69 38,71 0,935 0,62 4 1,63 0,7 1,12 12,3 MAK-M 71B-6 0,18 901 1,28 61,41 0,977 1,91 8 2,04 0,16 1,32 16,3 MAK-M- 80A-6 0,25 900 2,30 56,40 0,852 2,65 10 2,30 0,40 1,80 22,8 MAK-M 80B-6 0,37 940 2,92 60,31 0,893 3,76 10 2,78 0,33 1,77 24,8 MAK-M- 90S-6 0,55 870 4,50 59,50 0,858 6,04 18 2,20 0,41 1,30 29,4 MAK-M- 90L-6 0,75 888 5,09 68,26 0,931 8,07 25 2,09 0,59 1,50 31,4 MAK-M 100LB-6 1 958 6,16 74,10 0,967 9,97 45 4,03 0,34 1,44 43,4 MAK-M 112M-6 1,5 925 9,20 75,50 0,947 15,49 35 3,03 0,34 1,00 57,4

Permissible radial and axial load The permissible radial loads given in table relate to service life of the bearings of 20000 h for 2 poles motors and 40000 h for 4, 6, 8 poles motors operating with 50 Hz power supply. If the shaft end is loaded at E2 with the permissible radial load FR (E2),an additional axial load FA is allowed, equal with 0.8xFR (E2) when the rotor is pushed, or 0.35xFR (E2) when the rotor is pulled. For operating at 60 Hz the values have to be reduced by 6% in order to achieve the same useful life. Frame size Poles Permissible radial load FR (N) E0 E1 E2 56 2 355 325 300 4 345 320 295 2 360 330 310 63 4 350 325 305 6 405 375 350 8 445 415 385 2 450 415 380 71 4 430 395 365 6 500 460 425 8 550 510 470 2 605 550 505 80 4 590 535 490 6 665 605 555 8 735 670 615 2 665 595 540 90 4 655 585 530 6 825 740 670 8 745 670 610 2 930 840 765 100 4 900 810 740 6 1025 925 845 8 1125 1015 925 2 1355 1230 1120 4 1325 1200 1095 112 6 1495 1350 1235 8 1655 1495 1365 Ball bearings Frame size Drive end Non Drive end 56 6201 2Z 6200 2Z 63 6202 2Z 6202 2Z 71 6203 2Z 6203 2Z 80 6204 2Z 6204 2Z 90 6205 2Z 6205 2Z 100 6206 2Z 6206 2Z 112 6306 2ZC3 6306 2ZC3

Mounting B3 Type A AA AB AC AF B BB BF C D DA E F GA GD H HA HD K L LL Z IC-GK 56 A 90 22 105 110 91 71 90 103 36 9 M3 20 3 10,2 3 56 6 176 6 200 43 9 1X1/2 63 A/B 100 30 120 125 101 80 100 113 40 11 M4 23 4 12,5 4 63 7 201 7 245 68 10 1X1/2 71 A/B 112 31,5 140 140 101 90 110 113 45 14 M5 30 5 16 5 71 8 217 7 283 80 10 1X1/2 80 A/B 125 39 155 158 131 100 130 140 50 19 M6 40 6 21,5 6 80 9 237 10 327 85 15 1X3/4 90 S 140 34 170 177 131 100 130 140 56 24 M8 50 8 27 7 90 9 255 10 363 101 15 1X3/4 90 L 140 34 170 177 131 125 155 140 56 24 M8 50 8 27 7 90 9 255 10 383 101 15 1X3/4 100 LA/LB 160 45 196 200 131 140 170 140 63 28 M10 60 8 31 7 100 12 284 12 440 127 15 1X3/4 112 M 190 48 224 222 151 140 170 162 70 28 M10 60 8 31 7 112 12 318 12 456 130 15 2X1 Mounting B5/B35 Type A AA AB AC AD AF B BB BF C D DA E F GA GD K L LA LL M N P n S U T IC-GK 56 A 90 22 105 110 120 91,0 71 90 103 36 9 M3 20 3 10,2 3 6 200 8 43 100 80 119 4 7 45 3 1X1/2" 63 A/B 100 30 120 125 138 101 80 100 113 40 11 M4 23 4 12,5 4 7 250 8 72 115 95 140 4 10 45 3 1X1/2" 71 A/B 112 31,5 140 140 147 101 90 110 113 45 14 M5 30 5 16 5 7 284 8 80 130 110 160 4 10 45 3,5 1X1/2" 80 A/B 125 39 155 158 157 131 100 130 140 50 19 M6 40 6 21,5 6 10 328 9 86 165 130 200 4 12 45 3,5 1X3/4" 90 S 140 34 170 177 165 131 100 130 140 56 24 M8 50 8 27 7 10 364 9 102 165 130 200 4 12 45 3,5 1X3/4" 90 L 140 34 170 177 165 131 125 155 140 56 24 M8 50 8 27 7 10 384 9 102 165 130 200 4 12 45 3,5 1X3/4" 100 LA/LB 160 45 196 200 184 131 140 170 140 63 28 M10 60 8 31 7 12 440 10 127 215 180 250 4 15 45 4 1X3/4" 112 M 190 48 224 222 206 151 140 170 162 70 28 M10 60 8 31 7 12 456 11 130 215 180 250 4 15 45 4 2X1"

Mounting B14/B34 Type A AA AB AC AD AF B BB BF C D DA E F GA GD H HA HD K L LL M N P S T IC-GK 56 A 90 22 105 110 120 91 71 90 103 36 9 M3 20 3 10,2 3 56 6 176 6 200 43 65 50 80 M5 2,5 1X1/2 63 A/B 100 30 120 125 138 101 80 100 113 40 11 M4 23 4 12,5 4 63 7 201 7 250 72 75 60 90 M5 2,5 1X1/2 71 A/B 112 31,5 140 140 147 101 90 110 113 45 14 M5 30 5 16 5 71 8 218 7 284 80 85 70 105 M6 2,5 1X1/2 80 A/B 125 39 155 158 157 131 100 130 140 50 19 M6 40 6 21,5 6 80 9 237 10 328 86 100 80 120 M6 3 1X3/4 90 S 140 34 170 177 165 131 100 130 140 56 24 M8 50 8 27 7 90 9 255 10 364 102 115 95 140 M8 3 1X3/4 90 L 140 34 170 177 165 131 125 155 140 56 24 M8 50 8 27 7 90 9 255 10 384 102 115 95 140 M8 3 1X3/4 100 LA/LB 160 45 196 200 184 131 140 170 140 63 28 M10 60 8 31 7 100 12 284 12 440 127 130 110 160 M8 3,5 1X3/4 112 M 190 48 224 222 206 151 140 170 162 70 28 M10 60 8 31 7 112 12 318 12 456 130 130 110 160 M8 3,5 2X1 B5/B14 special mounting B5 reduced Frame size C D M N P S 71 57 (*) 115 95 140 10 80 71 (*),(**) 130 110 160 12 90 71 (*) 130 110 160 12 100 76 (*) 165 130 200 15 112 83 (*) 165 130 200 15 B14 special Frame size C D M N P S 71 45 (*) 115 95 140 M8 80 50 (*),(**) 130 110 160 M8 90 56 (*),(**) 130 110 160 M8 100 63 (*),(**) 165 130 200 M8 112 70 (*),(**) 165 130 200 M10

Single phase motors capacities dimension Type MAK-M 63 71 80 90 100 112 J 23 40 / / / / W / / 30 30 50 60 Y 120 110 115 135 155 160 Output shafts dimensions Type D d1 d2 d3 t1 mm mm mm mm mm 56 9j6 M3 3,2 5,3 12 63 11j6 M4 4,3 6,7 14 71 14j6 M5 5,3 8,1 17 80 19j6 M6 6,4 9,6 21 90 24j6 M8 8,4 12,2 25 100 28j6 M10 10,5 14,9 30 112 28j6 M10 10,5 14,9 30 Balance degree according IEC 34.14 - ISO 2373 Balance degree Speed Limit value of the vibration speeds from 10 to 1000Hz Motor size 56-132 160 N (Normal) 600-3600 1.8 2.8 R (reduced) 600-1800 0.71 1.12 1800-3600 1.12 1.8 S (special) 600-1800 0.45 0.71 1800-3600 0.71 1.21

Single-phase motor connection diagrams Entrée des câbles pour alimentation moteur monophasé Frame size Standard On demand UNI6125 IEC 423 DIN 40430 ANSI B1.20.1 56-71 1 x 1/2 GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2 NPT 80-100 1 x 3/4 GK 1 x M 25 x 1.5 1 x PG 21 1 x 3/4 NPT 112 1 x1 GK 1 x M 32 x 1.5 1 x PG 29 1 x 1 NPT Auxiliaires cables entry FRAME SIZE STANDARD ON DEMAND UNI6125 IEC 423 DIN 40430 ANSI B1.20.1 63-112 1 x 1/2 GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2 NPT Cable entry for single-phase motor s supply MOTOR SIZE STANDARD ON DEMAND UNI6125 IEC 423 DIN 40430 ANSI B1.20.1 56-71 1 x 1/2 GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2 NPT 80-100 1 x 3/4 GK 1 x M 25 x 1.5 1 x PG 21 1 x 3/4 NPT 112 1 x1 GK 1 x M 32 x 1.5 1 x PG 29 1 x 1 NPT Auxiliary cables entry MOTOR SIZE STANDARD ON DEMAND UNI6125 IEC 423 DIN 40430 ANSI B1.20.1 63-112 1 x 1/2 GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2 NPT

P.T.F bimetallic type device nc/no Intervention temperature Voltage Current Cables colour Code 130 C NC Yellow - Yellow 32/33 V. 250 ± A. 2,5 COS 150 C NC Yellow - Yellow 32A/33A 5% φ 1 140 C NA 42/43 This device consists of a series connection of 1 or 3 protectors. The standard contact is closed /open; it opens/closes when the winding temperature reaches dangerous level regarding to the temperature class. C.T.P thermistor thermal detectors Intervention température. Câbles colour CODE 130 C BLUE - BLUE 12/13 150 C BLACK - BLACK 12A/13A 180 C WHITE - RED 12B/13B Once reached the operating temperature, this device quickly changes the resistance; it must be connected to a suitable releasing device according to DIN 44081-44082 standards. Space heaters Motor size Output (W) Voltage (V) Resistance (ω) Cables color Code 71-100 1x25(*) 1~ 220(**) 190 a 20 C Orange-Orange 70-71 112 2x25 série (*) 1~ 220(**) 191 a 20 C Orange-Orange 70-72 * Power has to be doubled when working at lower temperature than -20 C (up to -40 C). ** V. 110 on request Motor heating through motor windings Size For preventing condensation For temperatures below -20 C Output Line voltage with motors wound up to: Output Line voltage with motors wound up to: VA 230 V 400 V 440 V 500 V VA 230 V 400 V 440 V 500 V 56/63 25 45 75 90 100 65 70 120 140 160 71 40 35 65 75 85 100 60 100 120 130 80 50 30 55 65 75 125 50 90 100 115 90/100 70/100 25 40 50 55 175/250 40 60 70 80 112 150/200 20 35 40 45 370/500 30 55 65 70

Specification Spare parts 1. Drive end shield 2. Frame 3. Shaft with rotor 4. Key 5. No drive end shield 6. Cooling fan 7. Cover fan 8. Terminal box 9. Terminal board 10. Flange 11. Rubber 12. Rectify screw 13. Terminal box cover - 14. Ball bearings - 15. Spring washer - 16. Sealing ring - 17. Flange B5 -