[ ]

Similar documents
OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE INCLUDE MANUAL: S-632 GENERAL INFORMATION MANUAL (PN )

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Temperature Sensor Series

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

IOM FOR DYNATORQUE D-LOCK LOCKING DEVICE (DL TYPE)

Pressure Sensor No Series

DEMCO Resilient-Seated Butterfly Valve

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

INSTRUCTION MANUAL. Series PROCUNIER SAFETY CHUCK CO. (Serial Nos. B4870 and higher. (Serial Nos. B9230 and higher

OPERATION AND PARTS MANUAL

Installation and Maintenance Instructions JSE MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

Check Valve (Next Generation) A-180 and A-183 Series. Installation, Operation & Maintenance (IOM) Manual. P/N: A-180/A-183, Rev. 6.

Installation and Maintenance Instructions JSE1-0128MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

OPERATION AND PARTS MANUAL

MODCO TM FIGURE 500 CLOSURE

Tool-less Hinged Closure Installation, Operation, & Maintenance

SV HIGH VACUUM (Positive Relief) SEAL-OFF VALVE 1 Inch Size

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Installation and Maintenance Instructions JSE2-0241MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

High Lift Transmission Jack

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE

Installation Instructions

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

B14 AAA FINE FINISH SERIES PUMP OUTFIT

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

Disassembly and Reassembly for CBB-SR (Spring Return) Series Pneumatic Actuators

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

Maintenance Instructions. World Leader in Modular Torque Limiters. JSE AEA Extruder Clutch

B14 AAA FINE FINISH SERIES PUMP OUTFIT

MOTION DECOUPLED HYDRAULIC DELIVERY SYSTEM (MDHDS) ASSEMBLY AND DEPLOYMENT PROCEDURES

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

TURBO DRIVE INSTALLATION MODEL 3700T TABLE FEED Sharp, Chevalier & Others

FaceClipper Model # Serial #

PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

FaceClipper Model # Serial #

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP


TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

GBP784B INSTALLATION TOOL

UTV Universal Stronghold Auto- Latch Double Boot Mount

RECOMMENDED PROCEDURE FOR INSTALLATION OF DRILLCO MAXI-BOLT ANCHORS

LS Series. Remix Shaft Installation Instructions REQUIRED TOOLS PARTS WORK SAFELY! PREPARATION/SAFETY PROCEDURES

Operating Procedures for 4 to 24 Double Block and Bleed Test and Isolation Plugs

INSTRUCTION MANUAL IM-422 For HTC/COUPLING ASSEMBLY HC-8088

270PK SERVICE GUIDELINES

V&P SCIENTIFIC LEVITATION STIR BALL LOADER. VP 725C-96 Operating Instructions

Operation and Maintenance Manual

LEAK TEST PROCEDURE MRT4-DC LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

Model DFR 070/156/220 Rotary Actuator

Product Customization Guide TSE Brakes, Inc.

Jeep Wrangler Heavy Duty Drag Link Installation Instructions

MGM Brakes Service Manual

RANGER 900 POWER STEERING KIT

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

IOM Manual. IOM Manual. Series 20/21.

INSTALLATION & MAINTENANCE MANUAL

Property of American Airlines

VLP-UL-KIT INSTALLATION INSTRUCTIONS. The VLP-UL-KIT for 36 or 48 is a field installable solenoid latch pullback for the Von Duprin 33/35 &

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Audi-Larm TM Audible Alarm: AirHawk II Air Mask

PNEUMATIC SLIDING VALVE

5019 JK FRONT AIR BUMP KIT (THRU COIL)

ENGINEERING STANDARD

CD42 T-Series 22 Hz Electromagnetic Transmitter

Model 800 Disassembly Instructions and Troubleshooting

Fisher 656 Diaphragm Actuator

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

#10 Setting Tool Assembly Product Family No (10)

FaceClipper Model # Serial #

LEAK TEST PROCEDURE DC CHANNEL LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

Fisher 2052 Diaphragm Rotary Actuator

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

Instructions for Installation, Operation Care and Maintenance

Operating Procedures for 4 to 24 GripTight Isolation Plugs

PSR-HP-3000 MANUAL HAND PUMP INTERNAL LIQUID CAPICITY MAXIMUM OUTPUT PRESSURE PsiG (BarG) GALLONS (LITERS) 3000 (207) 5 (19)

Installation, Operation and Maintenance Manual

Specifications Information and Repair Parts Manual , , , &

Lead-free Pneumatic Metering Valve Assemblies (Plastic Bodied) WILLOUGHBY Industries, Inc WEST 78TH STREET / INDIANAPOLIS, IN 46268

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Installation, Operation, and Maintenance Manual

VOYAGEUR 144 BRAKE LIGHT SUPPORT KIT

16K HYDRAULIC PLANETARY CAPSTAN DRIVE

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

Type 2000 Transducer Product Instructions

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

Disassembly and Reassembly for CBB (Double Acting) Series Pneumatic Actuators

Installation For Service Only

TOOLS NEEDED FOR REPAIR OF MK 14

SAE STANDARD BOLT ASSEMBLY NUMBER 60020_IR4 INSTALLATION AND OPERATIONS MANUAL

REACTOR DISCHARGE VALVES S & DIGESTER BLOW VALVES SB & 5300SB B FLANGED BALL VALVES

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

Transcription:

[ www.pigpopper.com ] Installation Guide

Pig Popper Installation Guide Enduro Pipeline Services, Inc. P.O. Box 489 Tulsa, OK 740 500 S. 45th W. Ave. Tulsa, OK 7407 p: (98) 446-94 toll-free: (800) 75-68 www.enduropls.com

Contents.0 Disclaimers and Privacy.0 Overview 4.0 Pressure Test Log 5 4.0 Installation Procedure: Pig Popper Manual (PPM) 6 4. Installation 6 4.. Tools Needed 7 4.. Removing the Pipe Nipple 7 4.. Removing the Pig Popper Plug Assembly 9 4..4 Installing the Pipe Nipple 0 4..5 Inserting Trigger Ball Assembly into Pipe Nipple 4..6 Spring Placement 4..7 Pipe Cap Installation Appendix A: Pig Popper Drawings: 000-9-086 4.0 Disclaimers and Privacy The information contained in this document is the proprietary and exclusive property of Enduro Pipeline Services, Inc., except as otherwise indicated. No part of this document, in whole or in part, may be reproduced, stored, transmitted, or used for design purposes without the prior written permission of Enduro Pipeline Services, Inc. The information contained in this document is subject to change and/or revision without notice. 00-40-675 - Rev B

.0 Overview The Pig Popper is an intrusive pig signal that is manually reset once it has been tripped by a pig.»» Pig Popper Manual (PPM) alert (# 000-9-0974) Extensions are available in 6 inch increments for buried pipe locations. All units are also available in a lighted (beacon) version. The Pig Popper is designed to be fitted on most existing inch fittings. The Pig Popper Assembly may be installed in any location around the pipe perpendicular to the center line of the pipe. U.S. Patent # 8096 C A P I N D I C A T O R H O U S I N G I N D I C A T O R D U S T C O V E R.44 P I P E C A P 9.66 P I P E N I P P L E.50 B A L L T R I G G E R Figure.0 00-40-675 - Rev B 4

.0 Pressure Test Log We have designed and built a test vessel specifically for the testing of our pig signal devices. The vessel presently tests our Pig Popper Model (PPM units) at pressures from 0 to 4,000 psi. A pneumatic plunger resets the pig signal each time a pig simulator passes and triggers the pig signal probe. With our Pressure Compensated Pig Popper there is no need to change the internal spring based on line pressures. The following chart indicates the number of cycles (pig passes) and the operating pressure maintained during testing. Note: The life of the Pig Popper test is the additive cycle period of each test combined. The mechanical testing of the Pig Popper is equivalent to approximately 0 years with no failure. Pressure Cycles Media 0 500 / 500 Water 400 500 / 000 Water 800 500 / 500 Water 00 500 / 000 Water 600 500 / 500 Water 000 500 / 000 Water 400 500 / 500 Water 800 500 / 4000 Water 00 500 / 4500 Water 600 500 / 5000 Water 4000 500 / 5500 Water Test ran 500 cycles at each pressure from 0 psi. to 4000 psi. and then from 4000 psi. back down to 0 psi. Running Total of cycle count was,000.»» Simulated pig passage in test vessel with mechanical pig passage and pneumatic reset.»» Terminated test after,000 cycles with a full range of psi levels having been met with no leaks or failures.»» To date the unit has exceeded all expectations and has proven to be of sound engineering and material selections.»» Further testing of the Pig Popper is constantly taking place.»» Additional models, such as a lighted version and control panel electrical units are also available. 00-40-675 - Rev B 5

C:\Vault-Local\Designs\0\00\000-9-0974.idw Enduro Pipeline Services, Inc. 4.0 Installation Procedure: Pig Popper Manual (PPM) ITEM QTY PART NUMBER SEE TABLE 000-9-09587 000-9-065 4 000-9-0840 Parts List REV. DESCRIPTION SEE TABLE ASSEMBLY, PIG POPPER PLUG ASSEMBLY, PIPE CAP ASSEMBLY, INDICATOR Table matrix applies to all models Table WALL THICKNESS LENGTH "A" PART NO..50" TO.500" 4.000" 000-0-0480.50" TO.750".750" 000-0-048.75" TO.000".500" 000-0-048.00" TO.50".50" 000-0-048.5" TO.500".000" 000-0-0484.50" TO.750".750" 000-0-0485 A 4 "A" A SECTION A-A ATERIAL OATING/FINISH ASS N/A 4. Installation Released 8/6/008 mattl REV DESCRIPTION Figure DATE 4.0 BY REVISION HISTORY ENDURO PIPELINE SERVICES, INC. 500 S. 45th W. Ave., Tulsa, Oklahoma 7407 Tolerances Unless Otherwise Phone: 98-446-94 Fax: 98-446-85 Specified TITLE REVISION Decimal:.xx = +/-.5 ASSEMBLY, PRESSURE COMPENSATED PIG POPPER Angular: x.x = +/- deg. Dimensions are in inches PART# DATE CREATED These instructions apply to all models of the Pig Popper. See Section 5.. 000-9-0974 8/6/008 SHEET OF Removing the Pipe Nipple on page 7 for Adjustable Spring Guide exception. important Partial Disassembly Required before Installation Important: Your Pig Popper has been assembled and tested prior to shipping, however; some disassembly of the unit is required prior to welding the pipe nipple to the pipeline. This will protect the working components and O-ring seals. warning Do Not Weld Warning: Welding the Pig Popper to the pipeline with the trigger ball assembly inside the pipe nipple will compromise its integrity and will void the warranty. 00-40-675 - Rev B 6

4.. Tools Needed / inch x /4 inch socket adapter (included) /6 inch hex key Socket wrench with / inch drive 4.. Removing the Pipe Nipple Step - Trip the Trigger Ball to release the Indicator Cap Assembly. This will release the Cap Assembly from the internal catch finger assembly. Does not apply to model PPE. Step - Remove the safety set screw from the Pipe Cap. Step Step 00-40-675 - Rev B 7

Step - Unscrew the Pipe Nipple Assembly from the Pipe Cap (counter clockwise). Step 4 - Remove the Spring Guide Assembly and set it aside to re-install later. Note/Exception: For Model PPE, the Spring Guide Assembly is preadjusted to the necessary length to trigger the indicator (Adjustable Spring Guide Assembly). Step 5 - Remove the Trigger Pin from the Trigger Ball Assembly to prevent it from getting it lost. Step Step 5 Step 4 00-40-675 - Rev B 8

4.. Removing the Pig Popper Plug Assembly Step - Remove the Pig Popper Plug Assembly (turn counter clockwise) from the Pipe Nipple using the ½ inch X ¾ inch socket adapter included with the pig popper kit. Note: You will require a socket wrench with a ½ inch drive for the adapter socket. Step 00-40-675 - Rev B 9

4..4 Installing the Pipe Nipple hot Tapping When tapping a line that is in service, refer to the tapping machine manufacturer s procedures for hot tapping. Important: Extreme Care Required when welding the nipple to the pipeline. The Pig Popper is made of high precision, close-tolerance parts and any deformation of the nipple will result in the inability to reassemble the unit after nipple installation. cool to the touch: It is important to keep the nipple as cool as possible during the welding process by allowing the weld and surrounding material to cool to the touch between each weld pass and prior to installing the plug assembly. Caution Use welding and safety Codes Welding Codes ASME B.4 ASME B.8 Pressure/Hydro Information For liquid transportation systems inclusive of hydrocarbon, liquid petroleum gas, anhydrous ammonia and alcohol. Gas transportation and distribution piping systems. Hydro Testing Debris/Brass Plug Hydro testing can be performed with the pig popper plug assembly installed in the nipple; no additional pipe cap on the nipple is required. It is not recommended to use a pipe cap for pressure tests as they can be over-torqued, causing damage to the nipple. If there is a high amount of debris expected, it is recommended to replace the pig popper plug assembly with a solid brass plug during the test. This will prevent any debris from getting into the mechanism of the pig popper during testing. Brass plugs are available from Enduro. Attach the indicator nipple to the pipeline in accordance with the pipeline company s welding specifications in the following sequence (use Figure 4..0 as a reference): General Installation Procedures Step - Mask off the internal and external threads on the Pipe Nipple to protect against weld splatter. Step - At the point of installation, drill the pipe for indicator protrusion into the pipeline by using a -/ diameter drill bit. Step - Remove all drill shavings and burrs from the edge of the hole. Step 4 - Carefully position the nipple on the pipe so that it is centered over the -/ hole and level with the line pipe. Proper alignment is critical for the pig popper to function correctly. Weld in accordance with the appropriate welding codes. Allow weld and nipple to cool to the touch. Step 5 - Remove all masking material. 00-40-675 - Rev B 0

Pre-existing Nipple Step - Verify with the factory that the housing is compatible for use with the pig popper. Step - Chase the internal threads of the nipple with a thread chaser. This will require a special.875-8 thread chaser available from Enduro. The nipple is now ready for pig popper installation..50.5 Figure 4..0 00-40-675 - Rev B

4..5 Inserting Trigger Ball Assembly into Pipe Nipple Step - Apply grease to the Pig Popper housing O-rings. Step - Install the Pig Popper Plug Assembly into the welded Pipe Nipple using a ½ inch drive socket wrench and the provided ½ inch to ¾ inch adapter. Step - Place the Trigger Pin Plate pre-assembly inside the Pipe Nipple. Step Step Step 4..6 Spring Placement Step - Apply grease to the top portion of the Spring Guide. Step - Place the Spring back onto the Spring Guide. Step - Slide the Spring Guide, with the Spring on it, into the Pipe Cap Assembly. Step Step Step 00-40-675 - Rev B

4..7 Pipe Cap Installation Step - Apply Teflon tape or anti-seize to 5 to 6 threads of the Pipe Nipple. Step - Install the Pipe Cap Assembly onto the Pipe Nipple with the Spring Guide protruding thru the Pipe Cap and Catch Plate. Step - Tighten the Set Screw into the side of the Pipe Cap, thus locking the cap in place. Step 4 - To set the unit, push down on the Dust Cover Cap until a click is both heard and felt. The unit is now ready to be placed into service. Step Step Step Step 4 00-40-675 - Rev B

U:\Technical_Communications\Pig_Popper\drawings\000-9-086-Exploded.idw Enduro Pipeline Services, Inc. Appendix A: Pig Popper Drawings: 000-9-086 ITEM 4 5 6 7 8 9 0 4 5 6 7 8 9 0 4 5 6 7 8 9 0 4 5 QTY 4 4 Parts List PART NUMBER 000-0-07079 000-0-0574 000-0-0959 000-0-09589 O'RING INCH O'RING INCH 000-0-09590 000-0-0959 000-0-09588 O'RING INCH 8-5 ANSI B8.8. - / x 000-0-0959 ANSI B8. - 6- UNC x 0.5 000-0-066 000-0-0490 ANSI B8. - /4-0 UNC - /4 000-0-0580 V-000000 000-0-0579 O'RING INCH 000-0-058 ANSI B8.8. - /8 x./ Standard Duty ANSI B8. - /4-0 x /4 000-0-0586 000-0-0585 000-0-0587 000-0-0588 000-0-0590 O'RING INCH ANSI B8. - 0-4 x / 000-0-059 000-0-0589 000-0-4875 V-000006 REV. 5 5 4 8 8 DESCRIPTION PIPE, NIPPLE 4.000" SCARFED PIN, TRIGGER BALL BALL, TRIGGER HOUSING, INDICATOR LOWER O'RING -0 O'RING -00 PLUNGER, TRIGGER CAP, TRIGGER PLUNGER HOUSING, INDICATOR UPPER O'RING -5 BACK-UP RING Pin - Hardened Ground Production Dowel PLATE, TRIGGER PIN Hexagon Socket Set Screw - Flat Point GUIDE, SPRING SPRING, COMPRESSION.055 Hexagon Socket Head Cap Screw SPACER, PIPE CAP Sckt Set Screw /4"-0 Thrd, /4" Lg w/ brass tip CAP, PIPE O'RING - PLATE, CATCH FINGER Pin - Coiled Spring Hexagon Socket Button Head Cap Screw FINGER, CATCH SPRING, CATCH FINGER SPRING, INDICATOR PIN, CATCH FINGER HOUSING, INDICATOR O'RING -4 Hexagon Socket Button Head Cap Screw COVER, DUST CAP, INDICATOR TAG, SERIAL NUMBER NAIL, #0 X /4" EASY-DRIVE 4 5 0 9 8 7 4 6 5 0 8 7 5 6 4 9 5 0 8 7 4 9 6 00-40-675 - Rev B 4

P.O. Box 489 Tulsa, OK 740 500 S. 45th W. Ave. Tulsa, OK 7407 office: (98) 446-94 toll-free: (800) 75-68 www.enduropls.com

.800.75.68 [ www.enduropls.com ] 00-40-675 - Rev B