Ventilation grilles for installation into walls, sills or rectangular

Similar documents
Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ceiling swirl diffusers with perforated face plate

For installation into ductwork

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Slot diffusers for ceiling installation

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Pressure relief dampers

Ceiling swirl diffusers

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Grilles Linear Grilles

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Type VSD35. Nominal length up to 1500 mm: one spigot

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Grilles Linear Grilles

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

WGA Long throw nozzle grille

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Slot diffusers, Round duct diffusers. IMP Klima

Compact Grille Model KG

Ventilation grille Model IB-R

Round duct diffuser DBB-RR

Round duct grille Model KG-RR

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Ceiling diffuser 4DE

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

HIGH CAPACITY LINEAR SLOT DUFFUSERS

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

Ventilation grille Model AL

Catalog Swirl diffuser DAL 359

ceiling swirl diffuser DQJ

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Air Displacement Vent Units

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

WALL VENTILATION GRILLES CBP

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Nozzle Jet Diffuser Model DSA

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

SDV Vane Swirl Diffusers

LINEAR SLOT DUFFUSERS

Ceiling Swirl Diffuser DQJ

LINEAR SLOT DIFFUSERS

Ceiling Slot Diffuser Model DSX

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Wall and Ceiling Grille

Ceiling diffuser 4DF

CONSTANTFLOW Volume Flow Controllers

Swirl Diffuser Model DQF

Duct Nozzle Diffuser. L e

Ceiling impulse diffuser Model PIL

Ceiling Slot Diffuser DSC

ceiling swirl diffuser Model DQJA / DQJR

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

series Linear grilles

Ceiling Slot Diffuser DSC

LINEAR SLOT DIFFUSERS

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

Ventilation Grille PA

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Ceiling Slot Diffuser DSC

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

CAV controllers Type RN

Active Chilled Beams

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Volume Flow Limiters Type VFL

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Transcription:

X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation grilles with their gently sloped border combine function with an attractive design; they can be installed in walls, sills or rectangular ducts. Nominal sizes 225 125 1225 525 mm Volume flow rate range 19 2651 l/s or 68 9544 m³/h Energy-efficient and acoustically optimised air discharge Symmetric blade profile for two-way entry flow Uniform look and easy adjustment due to concealed blade linkage Gently sloped border construction, almost completely flush with the installation surface Linear look, ideal for continuous horizontal runs Use of existing rear assemblies Easy replacement of existing grilles due to standard installation dimensions Optional equipment and accessories Installation subframe Attachments for volume flow rate balancing and air direction control Concealed screw fixing Spring clip fixing Flat border construction PD XGB 1

General information Type Page General information XGB 2 Function XGB 4 Technical data XGB 7 Quick sizing XGB 8 Specification text XGB 9 Order code XGB 10 Dimensions and weight XGB 12 Product details XGB 14 Installation examples XGB 15 Installation details XGB 16 Commissioning XGB 17 Basic information and nomenclature XGB 18 Application Application Ventilation grille of Type as supply air or extract air variant for comfort zones and industrial zones Attractive design element for building owners and architects with demanding aesthetic requirements Directed supply air discharge for mixed flow ventilation Blades are adjustable to meet different local requirements For variable and constant volume flows For supply air to room air temperature differences from 12 to +4 K For installation in walls, sills and rectangular ducts Special characteristics Symmetric blade profile for two-way entry flow Concealed blade linkage for adjusting the blades simultaneously Gently sloped border construction, almost completely flush with the installation surface Linear look, ideal for continuous horizontal runs Nominal sizes Single grille Nominal length: 225, 325, 425, 525, 625, 825, 1025, 1225 mm Nominal height: 125, 225, 325, 425, 525 mm Horizontal run section Nominal length of end section: 950 2025 mm Nominal length of middle section: 2000 mm Nominal height: 125, 225, 325 mm Other dimensions upon request PD XGB 2

General information Description Variants Single grille Horizontal run section Fixing VS: Concealed screw fixing KF: Spring clip fixing VS, KF only with installation subframe Parts and characteristics Gently sloped border Horizontal blades with concealed linkage to adjust blades simultaneously Vertical centre mullion for nominal lengths over 625 mm Concealed screw fixing and spring clip fixing, optional Attachments AG, AS, D, DG: For volume flow rate balancing and for air direction control Accessories Installation subframe: For the fast and simple installation of ventilation grilles Construction features Only small clearance between blades and border Centrally supported blades Materials and surfaces Border made of galvanised sheet steel Blades made of aluminium Linkage and end pieces for blades made of highly temperature resistant special plastic, flame retardant to UL 94, V-0 Border and blades powder-coated RAL 9010, pure white P1: Powder-coated, RAL CLASSIC colour Standards and guidelines Sound power level of the air-regenerated noise measured according to EN ISO 5135 Maintenance Maintenance-free as construction and materials are not subject to wear Inspection and cleaning to VDI 6022 PD XGB 3

Function Functional description Ventilation grilles are air terminal devices for the supply air and extract air of ventilation and air conditioning systems. They direct the supply air into the room. Ventilation grilles with adjustable blades allow for adapting the discharge direction to the local conditions. The result is a mixed flow ventilation in comfort zones and industrial zones, with good overall room ventilation. Induction slows the airflow down, i.e. the airflow velocity decreases as the distance from the grille increases. The distance at which the airflow velocity reaches a certain defined value, e.g. 0.2 m/s, is called throw distance. The supply air jet from wall grilles that are installed near the ceiling achieves a larger throw distance than a free jet (from a grille that is not installed near the ceiling). Single grilles, groups of grilles and continuous horizontal runs all achieve different throw distances. In cooling mode it is necessary to take account of the jet deviation towards the occupied zone, which increases as the supply air to room air temperature difference increases and the discharge velocity decreases. In heating mode the supply air jet deviates towards the ceiling. This has no negative effect on the airflow velocity in the occupied zone, but it may affect the complete ventilation of the room. Schematic illustration of a ventilation grille with longitudinal blades 1 3 2 1 Front border 2 Longitudinal blades 3 Centre mullion Air pattern in cooling mode, with ceiling effect, sectional view Air pattern in cooling mode, without ceiling effect, sectional view Distance from ceiling 0.3 m Distance from ceiling 0.8 m PD XGB 4

Function Air pattern with ceiling effect, sectional view Air pattern without ceiling effect, sectional view ls ls Distance from ceiling 0.3 m Distance from ceiling 0.8 m Air pattern with ceiling effect, top view Air pattern without ceiling effect, top view ls ls Air pattern with ceiling effect, group of grilles, top view Air pattern without ceiling effect, group of grilles, top view ls ls Distance between single grilles 0.15 l S Distance between single grilles 0.2 l S PD XGB 5

Function Air pattern, group of grilles, top view Air pattern, continuous horizontal run, top view b b < 0.1 l S Several single grilles arranged in a row and with not much distance between them have the same effect as a continuous horizontal run. PD XGB 6

Technical data Nominal sizes Horizontal run section Minimum volume flow rate Maximum volume flow rate, with L WA max. 40 db(a) without attachments Supply air to room air temperature difference Volumen flow rates for single grille for supply air. 225 125 to 1225 525 mm H: 125, 225, 325 mm 16 568 l/s or 58 2045 m³/h 97 2651 l/s or 350 9544 m³/h 12 to +4 K Geometric free area H L [mm] 225 325 425 525 625 825 1025 1225 A geo mm m² 125 0.013 0.019 0.026 0.032 0.037 0.051 0.064 0.077 225 0.025 0.038 0.051 0.064 0.073 0.103 0.129 0.155 325 0.057 0.077 0.096 0.109 0.154 0.193 0.232 425 0.102 0.128 0.146 0.206 0.258 0.310 525 0.160 0.182 0.257 0.322 0.387 PD XGB 7

Quick sizing X-GRILLE Cover,, volume flow rate ranges 1225 525 1025 525 825 525 625 525 525 525 1225 425 1025 425 825 425 625 425 525 425 425 425 1225 325 1025 325 825 325 625 325 525 325 425 325 325 325 1225 225 1025 225 825 225 625 225 525 225 425 225 325 225 225 225 1225 125 1025 125 825 125 625 125 525 125 425 125 325 125 225 125 Nenngröße 60 100 200 500 1000 2000 5000 10000 12000m 3 /h 15 20 50 100 200 500 1000 2000 3000 3600 l/s L WA = 40 db(a) with unrestricted airflow+ L WA = 40 db(a) with airflow restricted by 50 % PD XGB 8

Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Ventilation grilles with gently sloped border, rectangular, for supply and extract air. Function combined with an appealing design. Gently sloped border. Preferably for wall and sill installation but also suitable for rectangular ducts. Ready-to-install component which consists of a border and symmetrically and aerodynamically profiled, horizontal blades with a concealed linkage that allows for adjusting the blades simultaneously. Special characteristics Symmetric blade profile for two-way entry flow Concealed blade linkage for adjusting the blades simultaneously Gently sloped border construction, almost completely flush with the installation surface Linear look, ideal for continuous horizontal runs Materials and surfaces Border made of galvanised sheet steel Blades made of aluminium Linkage and end pieces for blades made of highly temperature resistant special plastic, flame retardant to UL 94, V-0 Border and blades powder-coated RAL 9010, pure white P1: Powder-coated, RAL CLASSIC colour Technical data Nominal sizes: 225 125 to 1225 525 mm Horizontal run section, height: 125, 225, 325 mm Minimum volume flow rate (supply air): 16 568 l/s or 58 2045 m³/h Maximum volume flow rate (supply air), at L WA max. 40 db(a) without attachments: 97 2651 l/s or 350 9544 m³/h Supply air to room air temperature difference: 12 to +4 K Sizing data [m³/h] Δp t [Pa] Air-regenerated noise L WA [db(a)] PD XGB 9

Order code as a single grille X-GRILLE-Basic AG / L H / B1 / VS / P1 RAL... Type X-GRILLE-Basic Single grille Attachments A Without (grille face only) AG Damper unit, opposed action blades AS Hit and miss damper D Air direction control, blades installed at 90 to the front blades, independently adjustable DG D combined with AG Nominal size [mm] L H Installation subframe VS, KF only with installation subframe No entry: none B1 With Order example: X-GRILLE-Basic-AG/525 225/B1/VS/P1-RAL 9016 Fixing VS Concealed screw fixing KF Spring clip fixing KB Without fixing material VS, KF only with installation subframe Surface No entry: powder-coated RAL 9010, pure white P1 Powder-coated, RAL... CLASSIC Gloss level RAL 9010 50 % RAL 9006 30 % All other RAL colours 70 % Attachments Damper unit, opposed action blades Nominal size 525 225 mm Installation subframe With installation subframe Fixing Concealed screw fixing Surface RAL 9016, traffic white, gloss level 70 % PD XGB 10

Order code for continuous horizontal runs X-GRILLE-Basic E R AG / L H / D1 / VS / P1 RAL... Type X-GRILLE-Basic Horizontal run section Section E End section M Middle section End section Specify only for end section R Right end section L Left end section Attachments A Without (grille face only) AG Damper unit, opposed action blades D Air direction control, blades installed at 90 to the front blades, independently adjustable DG D combined with AG Nominal size [mm] L H Length Middle section: 2000 mm End section: 950 2025 mm Height: 125, 225, 325 Order example: X-Grille-Basic-E-R-AG/1025 225/D1/VS Installation subframe No entry: none D1 For end section F1 For middle section Fixing VS Concealed screw fixing KB Without fixing material VS only with installation subframe Surface No entry: powder-coated RAL 9010, pure white P1 Powder-coated, RAL... CLASSIC Gloss level RAL 9010 50 % RAL 9006 30 % All other RAL colours 70 % Section End section End section Right end section Attachments Damper unit, opposed action blades Nominal size 1025 225 Installation subframe For end section Fixing Concealed screw fixing Surface RAL 9010, pure white, gloss level 50 % PD XGB 11

Dimensions and weight The weight table shows the available nominal sizes, 26 mm wide front border 26 H + 20 20 26 33 5 L + 20 L Nominal length Vertical centre mullion if L > 625 mm H Nominal height, single grille H mm L [mm] 225 325 425 525 625 825 1025 1225 125 0.5 0.6 0.8 0.9 1.1 1.4 1.7 2.0 225 0.8 1.0 1.2 1.5 1.7 2.2 2.7 3.1 325 1.4 1.7 2.0 2.3 3.0 3.7 4.3 425 2.2 2.6 3.0 3.9 4.7 5.5 525 3.1 3.6 4.8 5.7 6.7 Weights apply to ventilation grilles without attachments m kg for continuous horizontal runs H + 20 20 26 E 2,5 M = 2000 E 2,5 26 33 5 E End section M Middle section H Nominal height PD XGB 12

Dimensions and weight for continuous horizontal runs H E Section mm kg/m kg 125 1.6 3.2 225 2.6 5.2 325 3.6 7.2 Middle section M: 2000 mm End section E: 950 2025 mm in increments of 1 mm Weights apply to sections without attachments M PD XGB 13

Product details Front border longitudinal section (L), 28 mm 5 38 26 Front border transverse section (H), 28 mm 4,7 38 26 X-GRILLE blade 29 7 PD XGB 14

Installation examples Wall installation Nominal length up to 625 mm: without vertical centre mullion PD XGB 15

Installation details Installation and commissioning Installation preferably in walls, sills and rectangular ducts Installation with installation subframe is recommended These are only schematic diagrams to illustrate installation details. Ventilation grille with concealed screw fixing 2 1 3 1 Installation subframe 2 Concealed screw fixing 3 Ventilation grille Ventilation grille with spring clip fixing 1 2 3 1 Installation subframe 2 Spring clip 3 Ventilation grille PD XGB 16

Commissioning Volume flow rate balancing When several ventilation grilles are installed on the same duct, it may be necessary to balance the volume flow rates. AG: Damper unit with opposed action blades, adjustable, secured with a locking screw AS: Damper unit with hit and miss damper, adjustable, secured with a locking screw Air pattern Adjustable blades: Set the air control blades individually or together and depending on the local conditions D, DG: Air control blades, fitted at 90 to the front blades, can be adapted to the local conditions Volume flow rate balancing -*G X X Attachments -AG, -DG and Types AGW, DGW Volume flow rate balancing -S X X Attachments -AS, -KS, -RS and Type ASW PD XGB 17

Basic information and nomenclature Principal dimensions L [mm] Nominal length of the ventilation grille Nominal height of the ventilation grille m [kg] Weight H [mm] Nomenclature L WA [db(a)] Sound power level of the air-regenerated noise [m³/h] and [l/s] Volume flow rate Δp t [Pa] Total differential pressure l S [m] Distance from single grille or horizontal run section (throw distance) PD XGB 18