12V OIL & DIESEL PUMP MODEL NO: CFTP12

Similar documents
230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

CFT24 &CFT230 PART NOS:

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

LEAD ACID BATTERY CHARGER

1200W INVERTER GENERATOR

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

ORIGINAL INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

ARC ACTIVATED HEADSHIELDS

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

SUBMERSIBLE DIRTY WATER PUMP

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

OPERATION & MAINTENANCE INSTRUCTIONS

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

BATTERY CHARGER-STARTER

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

720W PORTABLE GENERATOR

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

OPERATION & MAINTENANCE INSTRUCTIONS

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

28W WORK LAMP Model: CTL28 Part No:

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

ELECTRIC CAR POLISHER

ENGINE DRIVEN 3 FULL TRASH PUMP

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

18V CORDLESS DRILL MODEL NO: CON18LiC

20V 1.5Ah LITHIUM-ION BATTERY

1 ELECTRIC WATER PUMP

SWIMMING POOL PUMPS Models SPP07, SPP10 & SPP15 Part Nos: , &

SUBMERSIBLE WATER PUMP

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

1100W PORTABLE GENERATOR

BENCH GRINDER WITH LIGHT AND WIRE WHEEL MODEL NO: CBG8370LW

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

12v / 24v Diesel Transfer Pump Kit

RECHARGEABLE SPOTLIGHT

OIL DRAINER MODEL No: COD70. Part No: ASSEMBLY and OPERATING INSTRUCTIONS 0707

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

8LITRE HAND SPRAYER MODEL NO: PHS8B USER INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

original instructions 18V Torch RFP1801

12V PORTABLE PRESSURE PUMP

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

RMT1201. ORIGINAL INSTRUCTIONS Cordless Multi-Tool

BENCH GRINDER WITH WIRE BRUSH WHEEL, LIGHT AND WHEEL DRESSER MODEL NO: CBG6250LW

18V CORDLESS COMBI DRILL MODEL NO: CON18NI

BENCH GRINDER MODEL NO: CBG6250

ARC ACTIVATED HEADSHIELD

ELECTRIC ENGRAVER 15W WARRANTY INSTRUCTION MANUAL SPECIFICATIONS WHAT S IN THE BOX. ozito.com.au. Electric Engraver

4V LITHIUM-ION SCREWDRIVER OWNER S OPERATING MANUAL

ELECTRIC IMPACT WRENCH

PRESSURISED SANDBLASTER MODEL NO: CPSB200B

PRESSURISED SANDBLASTER MODEL NO: CPSB100B PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

OPERATION & MAINTENANCE INSTRUCTIONS

HOT AIR GUN MODEL No. CHG 1500B Part No

PETROL POWER WASHER MODEL NO: PLS195, PLS265 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS0616

Cordless Rechargeable Saw Instructions for Use

HAND SPRAYER. MODEL NO: PHS8 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC0513

RPS1215 ORIGINAL INSTRUCTIONS. Cordless Pruner

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

CORDLESS IMPACT WRENCH

VEHICLE POSITIONING JACK

5 LITRE HAND SPRAYER

EC DECLARATION OF CONFORMITY

2 TONNE TROLLEY JACK

2 TONNE GARAGE JACK Model No: CTJ2QLP PART NO:

RECHARGEABLE SPOTLIGHT

GARAGE JACK MODEL NO: CTJ3000G PART NO: OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS

GARAGE JACK MODEL NO: CTJ3000QLB PART NO: OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS

18V CORDLESS STAPLER/NAILER

SHOT BLAST CABINET MODEL No. CSB20B Part No OPERATING & MAINTENANCE INSTRUCTIONS

ENGINE DRIVEN SEMI TRASH 3 PUMP MODEL NO: PS75

ELECTRIC IMPACT WRENCH

ATD-8400 BENCH TOP BLAST CABINET OWNER S MANUAL

3-TONNE GARAGE JACK OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CTJ3000GB PART NO: ORIGINAL INSTRUCTIONS

VARIABLE SPEED JIG SAW

Instruction Manual. CORDLESS DRILL 18V Li-ion WITH IMPACT FUNCTION. Model SROM 1172

GENERATOR MODEL NO: FG4050ES / FG5100ES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS0310

WHAT S IN THE BOX METAL CUTTING SHEARS. Metal Cutting Shears 500W INSTRUCTION MANUAL SPECIFICATIONS. Hex Key. Max. Thickness: ozito.com.

STAND FOR LOGBUSTER 5 MODEL NO: LB5S

PRESSURISED SANDBLASTER

12V CONSTANT PRESSURE PUMP

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

Power Paint Scraper 200W CPS-200. To view the full range visit: Instruction Manual 3 Year Replacement Warranty

ENGINE DRIVEN 2 PUMP

POND PUMP Model Nos:SPP3 & SPP6 0200

2¼ TONNE TROLLEY JACK

12V Oil Extractor Pump

Transcription:

12V OIL & DIESEL PUMP MODEL NO: CFTP12 PART NO: 7160100 OPERATION & MAINTENANCE INSTRUCTIONS GC0814

INTRODUCTION Thank you for purchasing this CLARKE Pump. The CFTP12 pump is designed only for use with diesel fuels and automotive oil and is suitable for extracting automotive oil from vehicle engines via the dip stick/filler hole. It must not be used with water, petroleum fuels or alcohol, nor if small solids are known to be in suspension. Contents: 1 x Pump, 1 x Inlet Hose, 1 x outlet Hose, 2 x Hose Clips. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase. No product can be returned to us without prior permission. This guarantee does not effect your statutory rights. IMPORTANT Please read all of the safety and operating instructions carefully before using this product. The following safety symbols may be found on the product. Read this instruction booklet carefully before use. Wear protective gloves Keep these instructions in a safe place for future reference. 2

ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility. SAFETY PRECAUTIONS WORK AREA 1. Keep the work area clean and well lit. Cluttered and dark areas invite accidents. 2. Do not operate power products in explosive atmospheres such as in the presence of flammable liquids, gasses or dust. Power products create sparks which may ignite dust or fumes. ELECTRICAL SAFETY 1. Do not abuse the electrical cable. Keep the cable away from sources of heat, oil, sharp edges or moving parts. Damaged or tangled cables increase the risk of electric shock. PUMP SAFETY 1. DO NOT use this pump where there is a danger of fire. 2. DO NOT use to pump ANY liquid other than diesel and automotive oil. 3. ALWAYS ensure the ON/OFF switch, mounted on the rear of the pump, is in the OFF (O) position, BEFORE connecting to the battery This is to avoid the possibility of arcing taking place, thereby reducing the risk of fire. 4. Switch the pump OFF immediately after the task is completed. 5. Do not use the pump if the switch does not turn it on and off. Any power product that cannot be controlled with the switch is dangerous and must be repaired. 6. If necessary, have your pump repaired by a qualified person using identical replacement parts. This will ensure that the safety of the product is maintained. 3

ENVIRONMENTAL PROTECTION 1. Take care to ensure that if diesel fuel is spilt that it is cleaned away using sand or treated with absorbent granules designed for the purpose. 2. Always make every effort to contain any spillage and prevent ingress into the local water course. ELECTRICAL CONNECTION & OPERATION 1. Connect the inlet and outlet hoses to the pump after removing the black plastic caps as shown. NOTE: The black plastic flange remains fixed to the pump connection. 2. Connect the inlet and outlet hoses to the pump using the hose clips supplied. The hose and connections need to be completely air tight, otherwise air will be drawn in and reduce the flow. The smaller hose (marked IN) is designed to fit the dipstick opening and the larger one is the outlet hose. 3. Insert the inlet/outlet tubes into the engine dipstick opening and a suitable container for waste oil. 4. Ensure the ON/OFF switch, located at the rear of the pump, is set to the OFF (O) position BEFORE connecting the pump to the car battery. 4

WARNING: THIS IS TO AVOID THE POSSIBILITY OF SPARKING TAKING PLACE AND THEREBY REDUCING THE RISK OF FIRE. DO NOT USE WITH PETROL OR ANY OTHER HIGHLY FLAMMABLE LIQUID. Position the pump on a suitable surface in the engine bay as shown. Only connect this pump to a 12V battery. Ensure also that the battery terminals are clean and firmly attach the RED clamp to the POSITIVE and the BLACK clamp to the NEGATIVE terminals respectively. Double check to ensure the clamps cannot be disturbed easily, and that the 5

setup is protected from passers by. Set the switch, at the rear of the pump to ON (I). Do not allow the pump to run dry for more than 30 seconds after pumping has stopped. MAINTENANCE The pump requires no maintenance, but should be inspected before use to ensure that the electric power cables and clamps are in good condition. Ensure that the hoses used are perfectly sound. Avoid using solvents if cleaning plastic parts, as most plastics are susceptible to damage from various types of commercial solvents. Store the pump in dry conditions protected from the weather. For any problems requiring dismantling of the pump, contact your CLARKE dealer. SPECIFICATIONS Fluid Classification / Fluids to be used Max. Head Max. Flowrate (dependant upon temperature/type of oil) Max Operating Time Max. Temperature of liquid being pumped Self Priming Weight Inlet Hose Length Outlet Hose Length Motor IP Rating Clean (motor oil, diesel) 0.7 m 1.5 litres/min (diesel) 0.2 litres/min (engine oil) 30 mins 60 o C (Oil) / 45 o C (Diesel) Yes 0.85 kg 1.2 m 1.6 m 12V DC / 9.4 A IPx4 Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice. Always consult the pump s data plate. 6

DECLARATION OF CONFORMITY 7