General Specifications

Similar documents
General Specifications

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition

General Specifications

General Specifications

Instruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA

General Specifications

General Specifications

General Specifications

Model PH87 Retraction Sensor Assembly

General Specifications

Manifolds for DPHarp EJA and EJX Pressure and Differential Pressure Transmitters. Pressure psi (bar) (860) (552) (413) 4.

User Manual. Model PR20 Retractable fitting for combined ph/redox electrodes. IM 12B6K3-E-E 9th Edition

Instruction Manual YOKOGAWA. ph/orp. Model FD20 Immersion Fittings. IM 12B06K02-01E-E 9th edition. IM12B06K02-01E-E_ed09.indd 1 07/03/16 09:51

Instruction Manual YOKOGAWA. Model FD20 Immersion Fittings. ph/orp. IM 12B6K2-01E-E 7th edition

General Specifications

General Specifications

Variable V Area Flowmeter Rotameter The Original

General Specifications

General Specifications

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Personal ph, ph/orp, Conductivity Meters

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

General Specifications

User Manual. Model PD20, PF20 and PS20 Compact ph Probe YOKOGAWA. IM 12B6K4-01E-E 8th Edition

Digital ph transmitter

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

Digital ph transmitter

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

DISSOLVED OXYGEN MEASUREMENT

Signet 3719 ph/orp Wet-Tap Assembly

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

Inductive conductivity meter

General Specifications

MCF3 25CT Inrush-withstand

General Specifications

MCF3 DC86V11CT Inrush-withstand

General Specifications

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

General Specifications

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page

General Specifications

General Specifications

Inductive conductivity meter

Signet Conductivity/Resistivity Electrodes

Signet DryLoc ph/orp Electrodes

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Flow-Through Fitting ARF 215

OD OD DIGITAL DISSOLVED OXYGEN CONTROLLERS

Data Sheet No 241 Jan 2002 Issue G. Electrode Holders & Brackets for Conductivity Type Systems

WalkLAB Digital Dissolved Oxygen meter HD9030

General Specifications

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

Instrumentation Manifolds Traditional C13WT series. For DPharp EJX & EJA-E Differential Pressure and Pressure Transmitters

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

Signet DryLoc ph/orp Electrodes

Conductivity Measuring Cells ConduMax W CLS 19

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Royce Total Suspended Solids Systems. Water & Wastewater

Signet Conductivity/Resistivity Electrodes

Model DFX Doppler ultrasonic flow meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Mobrey MSM400 Ultrasonic sludge density measurement system

Measuring Cells for free chlorine, chlorine dioxide, ozone

General Specifications

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

General Specifications

Metal tube variable area flowmeter for gases, liquids and steam

Thermowell For sanitary applications Model TW61, for orbital welding

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Combination ph/redox (ORP) Sensors

Industrial automatic self-cleaning filters made in stainless steel AISI 316

* * Rev. 9 01/18 Product Manual

WEDGE & SLAB GATE VALVES

General Specifications

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Signet V(D) to V(D) PVDF Conductivity Electrodes

ph-kompaktelektrodensystem sensopac CPA 320

General Specifications

Instruction Manual. Model FF20 Flow fittings. Model FS20 Subassembly flow fittings. IM 12B6K1-01E-E 7th edition

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Pressure Transmitter. Informational & Installation Manual

871DO-C Dissolved Oxygen Sensors and Sensor Accessories

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Signet ph/orp Electrodes

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

SELF-CLEANING FILTER

Process to Instrument Valves: C13SF Monoflanges For DPharp EJX & EJA-E Pressure Transmitters

Control Components Pty Ltd. Drawing Number. Indicator Model Overview A 66.01A Side flanged connection

Signet ph/orp Electrodes

Combination ph/redox (ORP) Sensors

GLASS LINING TECHNOLOGIES. Bottom Outlet Valves

Transcription:

General Specifications Model DO30G and FD30/PB30 Sensor and fittings for Dissolved Oygen DO The DO30G sensor for dissolved oygen is designed for use in water treatment plants such as sewage treatment works, effluent activated sludge process, and potable water treatment. It is also effective in river monitoring, intake protection, fish farming and other fields where water quality is important. This galvanic cell has a fast response time and good long term stability, and features replaceable diaphragm and cable for easy maintenance. A temperature sensor is incorporated for compensation. The DO30G sensor can be used in either the PB30 floating ball fitting or in the FD30 immersion fitting. The PB30 floating ball holder for the DO30G features a design which minimises fouling by the process. A brass ring around the sensor facilitates a check for membrane integrity, and helps to eliminate any deposits of algae, making a cleaning system unnecessary for the model PB30. Maintenance is very simple, with only periodic inspection and calibration needed. The FD30 PVC immersion fitting is designed for installing the DO30G sensor in tanks, open vessels and drains. It can be supplied in lengths between 0.5 and 2.0 meter. Flange mounting is also possible. In applications with a heavy load of solids the use of a cleaning system is recommended, so an option, a jet cleaner is available for the immersion fitting. The use of this device can etend the continuous measurement period and eases maintenance. Features DO30G Fast response time Good long term stability Easy membrane change PB30 Easy to install Easy calibration Sensor diagnosis for membrane integrity FD30 Various immersion depths Flange mounting possible Cleaner option Sensor diagnosis for membrane integrity System configuration Sensors Cables Fittings Transmitters Accessories 9th edition

2 DO30G Sensor The DO30G sensor, which replaces the previous model DOX8SM, is the heart of Yokogawa s Dissolved Oygen measuring loop. It can be supplied with membrane thicknesses of 25 or 50 µm. The detachable connection cable comes in 5 different lengths between 3 meters and 20 meters. For convenience both the cell assembly and the cable are available as spare parts, as are the membrane sets and O-rings. Specifications General Measuring : Dissolved Oygen Measuring Principle : Galvanic cell method Measuring Range - Minimum : 0-2.5 ppm - Maimum : 0 to 20 ppm Liquid operating conditions - Temperature : 0 to 40ºC - Pressure : atmosphere - Flow velocity : Minimum 5 cm/sec Response time : < 60 sec Sensor Temperature compensation sensor : Pt1000 Wetted part materials : Hard PVC Fluorinated polymer (FEP) Stainless steel (SUS304) Nitrile rubber Soft PVC Polycarbonate Membrane : 25 or 50 µm Model and Suffi Code DO Sensor Model Suffi Code Description DO30G DO Sensor Membrane -S25 25 micron type -S50 50 micron Cable -03 3 mtr length -05 5 mtr -10 10 mtr -15 15 mtr -20 20 mtr Accessories Parts set for maintenance Part no. Description K1530UH Accessory kit for 50 micron membrane K1530UJ Accessory kit for 25 micron membrane Accessories (parts for maintenance) Contents - Electrolyte for sensor (50 ml), 1 bottle - Membrane, O-ring, 3 sets - Syringe for replacing electrolyte, 1 piece Shipping details Weight : Package size : Appro. 0.9 kg (with cable length of 5m) Weight of the sensor is appro. 0.1 kg : 295 230 165 mm

3 Dimensions 11 white Temp 12 brown Temp 13 green Cathode 14 yellow Shield 15 blue Anode 16 red Liquid earth Unit: mm (inch) Cable length (Standard: 3, 5, 10, 15 and 20 mtr) 46 (1,81) 38.5 (1,51) ø 26 (1,02) ø 36 (1,42) 108 (4.25) 10 (0,40) ø 30 (1,18) Figure 1. DO30G sensor

4 FD30 Immersion Holder Intended to mount the sensor in tanks, the immersion fittings should be installed where the point of measurement truly represents the entire solution. Avoid areas where the measurement value varies significantly e.g. stagnant corners. Select a place where the sensor is always immersed in the process liquid. The FD30 fitting is standard equipped with membrane check-facility and can be specified with or without a flange. Cable length and sensor membrane can also be specified in the MS code. For types without a flange, a mounting set and a jet cleaner are available as options. /JC Jet Cleaner This optional cleaner gives the opportunity to avoid build up of deposits and consequent fouling on the sensor membrane. This is achieved by spraying water (or air) onto the membrane of the DO-sensor. The spray head is equipped with a built-in (non-return) valve to avoid penetration of the process liquid into the cleaning system. The EXA DO400 has a built-in wash timer with programmable washtime, interval time and recovery time for the automatic cleaning of the sensor. Specifications General Wetted materials Fitting - Body & flange : Polyvinylchloride (PVC) - O-rings : Silicone rubber - Blanking plug : Ryton R4 (remove before use!) - Conductive bushing : Brass Options - Sensor/cable : See DO30G - Fle. conduit : PVC and Nylon - Jet cleaner : PVC, Nylon, PVDF and PTFE - Mounting : Galvanized steel Weight - Without flange : 1.35 kg + 0.2 kg per 0.5 meter - With flange : 0.5 kg etra Functional Fitting - Temperature : Min. : -10ºC Ma. : +50ºC - Pressure : Ma. 2 bar - Immersion length : 0.5 to 2.0 m (10 cm steps) When ordered as a subassembly (pipe length 00), a tube with PVC cement will be delivered with the holder. Cleaner (optional) - Temperature : As FD30V27 - Pressure : As FD30V27 - Immersion length : Additional + 4 cm. Model and Suffi Codes Immersion Fitting Model Suffi Option Description FD30V27 Immersion Fitting PVC Immersion -00 Pipe supplied by user length - Between 0.5 and 2.0 (in steps of 0.1m) Eample: 06 = 0.6 m Mounting -FN No flange flange -F1 DIN DN50 PN10 -F2 ANSI 2 150 lbs *A Style A Cable /C05 5 mtr /C10 10 mtr Protection hose /PH5 5 meter /PH10 10 mtr Cell-assembly /S25 25 µm membrane /S50 50 µm membrane Jet Cleaner /JC * Mounting set /MS1 * * Not available with flanged versions. Accessoires Accessories and Options (for sensor & cable see DO30G) Part no. Description K1530YZ Jet Cleaner (/JC) K1541ZY Mounting set (/MS1) K1500CJ 5 meter Protection hose kit (/PH5) K1500CK 10 meter Protection hose kit (/PH10) Spare Parts (for sensor & cable see DO30G) Part no. Description K1530UK Spray nozzle for Jet Cleaner K1530UL Tubing 1/4 for Jet Cleaner, 10 meter K1500AW Fleible conduit 5 meter K1500AX Fleible conduit 10 meter K1500AY Connection parts for fleible conduit K1500AZ Nozzle parts K1500FX O-ring set (5 pieces, silicone) for sealing the sensor K1500FY O-ring set (5 pieces, silicone) for mounting the sensor in the fitting

5 Dimesions 12J6K4-18 FD 30 18 (0.70) 18 (0.70) Ø 100 (3.94) 78 (3.07) 125 (4.92) 165 (6.60) Unit: mm (inch) Ø 40 (1.57) L Ø 40 (1.57) L Ø 50 (1.97) 90 (3.54) Ø 50 (1.97) 90 (3.54) FD30-V27- -F1(2)*A 70 (2.80) FD30V27- -FN*A 70 (2.80) Figure 2. Immersion assembly without flange Figure 3. Immersion assembly with flange ISO 228/1-G1 1/4 Sleeve Spacer Ø 48,6 600 (Ø1,9 24") Ø 50 (1.97) Min: 110 (4,35") Ma: 515 (20") 1/4" OD tube 115 (4.53) 134 (5.16) 2 pipe 42 (1.65) Figure 4. Option /JC Jet cleaner Figure 5. Option /MS1 Mounting set

6 PB30 Floating Ball The design of the PB30 floating ball ensures minimum user maintenance. The constant movement of the ball with the action of waves on the surface of the tank provides a good flow of sample at the membrane surface. Constant measurement depth is also assured. The solution ground ring in brass, gives the facility of a membrane check, while also minimising algae growth on the sensor. For convenience, the PB30 includes a winch mounting mechanism, and is normally specified as a unit complete with sensor and cable. Specifications Fitting - Wetted parts : High impact polystyrene, PVC & Brass - Temperature : 0-40 C - Mounting bracket : Galvanised steel, for rail, or surface mounting. - Sensor/cable : See DO30G Note: The standard pipe used for PB30 has a 50 mm outer diameter. For 11/2 pipe it is necessary to use the 11/2 adapters delivered with the PB30-00. Shipping details - Weight : Appro 12.5 kg. - Package size : 490320340 mm - Main support arm : 2.5 m Model and Suffi Codes Floating Ball Model Suffi Code Description PB30 Floating Ball Fitting Pipe length -00 Pipe supplied by user -25 2.5 meter Sensor type -SNN No sensor -S25 With 25 µm membrane -S50 With 50 µm membrane Cable length -00 No cable -05 5 mtr -10 10 mtr -15 15 mtr -20 20 mtr ACCESSORIES Spare Parts (for sensor & cable see DO30G) Part no. Description K1530DQ Mounting bracket for PB30 K1500AV O-ring set for PB30 25.33.2 (5) K1530SA Floating ball ass. Note: The standard pipe used for PB30 has a 50 mm outer diameter. For 1 1 /2 pipe it is necessary to use the 1 1 /2 adapters delivered with the PB30-00. Dimensions 111 (4.37) 70 (2.75) 121 (4.76) Ø 9 (.35) 164 (6.45) Figure 6.

7 Dimensions Unit: mm (inch) 2570 50 (100 2) Ø 50 (1,97) Rohr-/Schienenmontage DN 50 (2,00) 394 (15,50) 280 (11) Figure 7. Universal mounting assembly for floating ball fitting

Accessories Part no. Description DO30G FD30 PB30 K1530YZ Jet Cleaner (/JC) K1541ZY Mounting set (/MS1) K1500CJ Fleible conduit 5 meter and connection set (/PH5) K1500CK Fleible conduit 10 meter and connection set (/PH10) K1530UH Accessory kit for 50 micron membrane K1530UJ Accessory kit for 25 micron membrane Service Parts Part no. Description DO30G FD30 PB30 K1530UK Spray nozzle for Jet Cleaner K1530UL Tubing 1/4 for Jet Cleaner, 10 meter K1500AW Fleible conduit 5 meter K1500AX Fleible conduit 10 meter K1500AY Connection parts for fleible conduit K1500AZ Nozzle parts K1500FX O-ring set (5 pieces, silicone) for sealing the sensor K1500FY O-ring set (5 pieces, silicone) for mounting the sensor in the fitting K1530QA Lower support for PB30 K1530DQ Mounting bracket for PB30 K1500AV O-ring set for PB30 K1530SA PB30 assembly YOKOGAWA HEADQUARTERS 9-32, Nakacho 2-chome, Musashinoshi Tokyo 180 Japan Tel. (81)-422-52-5535 Fa (81)-422-55-1202 www.yokogawa.com YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 United States Tel. (1)-770-253-7000 Fa (1)-770-251-2088 www.yokogawa.com/us Yokogawa has an etensive sales and distribution network. Please refer to the European website (www.yokogawa.com\eu) to contact your nearest representative. YOKOGAWA EUROPE B.V. Databankweg 20 3821 AL AMERSFOORT The Netherlands Tel. +31-33-4641 611 Fa +31-33-4641 610 www.yokogawa.com/eu YOKOGAWA ELECTRIC ASIA Pte. Ltd. 5 Bedok South Road Singapore 469270 Singapore Tel. (65)-241-9933 Fa (65)-241-2606 www.yokogawa.com/sg Subject to change without notice Copyright Printed in The Netherlands, 09-705 (A) I