Tank Monitor. Instruction manual DTM01. Tank Monitor

Similar documents
TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

OWNER S MANUAL AUTOMATIC DISCHARGE PUMP CONTROLLER

8700 Series MasterFlush. Macerator Toilet Operation manual. Mazerier-WC Bedienungsanleitung WC dilacérateur Mode d emploi...

VacuFlush HTS-VG series (with vacuum generators) SeaLand HTS-T series (with discharge pumps) SeaLand HTS-Basic series (with fittings only)

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

TPHK Series Immersible Pump

INSTALLATION INSTRUCTIONS

RECHARGEABLE 24 LED WORK LIGHT

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

WR Air Accessory Mounting Brackets

Gooseneck Hitch Ball plate with 2-5/16" ball spins in/out 30,000 lb. rating. (5,000 lb. vertical load) Requires only one 3" hole in truck bed

Installation Instructions

TPAK Series COOLANT PUMP

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Microscope light manual

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Installation Instructions

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Model FM2642 Wall Mount. Full Motion Television Wall Mount

SUPER PUMP OUT SYSTEM

Grundfos MAGNA, Relay Module

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Thermaltake Warranty / Support Information

Cleaning & Sanitizing Instructions

Air and water reels. Models and Series B. Installation and maintenance guide DANGER

SOLAR DASH CHARGING SYSTEM USER GUIDE

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

Use/Installation Guide

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

TPHK Series Immersible Pump

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

ESE Series Cast Iron Sewage Pumps

Penguin Gentoo 600B Cordless Sprayer User s Manual

Models P, P, P, , DANGER

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

Compressor Isolator Kit 50714

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Power Distribution Units

INSTALLATION INSTRUCTIONS

Universal Installation Instructions

WARNING OPERATING PRESSURES: READ INSTALLATION INSTRUCTIONS COMPLETELY BEFORE INSTALLING YOUR KIT

Warranty Information North America

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

Viking Use/Installation Guide

Installation Instructions Soft Top Replacement Hardware, Wrangler

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

CLASSIC II Portable Braking System

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

The Esteem Steel Self Propel Wheelchair Instructions

PVI 60KW, PVI 82KW, PVI 95KW

Model A Turn Signal Kit Installation Guide

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Owner's Manual. For latest instructions please go to

Phase Sequence Tester

DEINES MANUFACTURING CORPORATION

Wall mount PMV pump with suction kits and hoses

Full Length Bed Rail - Model G29

SKID STEER COMBO PLOW

Warranty Statement. Global Commercial Warranty Statement. Commercial Generating Set Transfer Switch Switch Gear. A028U870 (Issue 1)

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

CTFRP Series Power Supplies

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

ESC Series Engine Shutdown Control

JAMP-500HR06-RC. Installation and Operation Instructions. 500W 4-CH Amplifier Kit For Harley Road Glide Fairing with Lower Fairing Speakers

COVER PAGE CUSTOM QUICK INSTALL MOUNTING KIT NOTE!

BATHROOM ACCESSORIES

Cable Length Meter INSTRUCTION MANUAL

POWER GEAR SLIDE-OUT MANUAL

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

ROUSH FUEL SYSTEM UPGRADE CURRENT FORD MUSTANG 5.0L

PIAA Multi-Fit 005/1100X Light Bracket Kits

Xtreme Air Command. Step 1 Prepare the components. Step 2 Select a mounting location. Parts list

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

MODEL FIXED MOTOR BRACKET

JAMP-250HR06P. Installation and Operation Instructions. 250W Amplifier Kit For Harley RoadGlide Fairing

Pressurized oil drain for collection of used lubricants and anti-freeze.

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

LDT Digital Temperature Gauge. Installation & Operation Instructions

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

Air Curtain. Installation, Operating and Maintenance Instructions

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

AIR CONTROL ACCESSORY KIT

PPP-13. Portable Power Pack Installation Instructions

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Deluxe ASA Halogen Spot/Flood Light

Heavy Duty Air Command

OWNER S MANUAL WARNING

TWO YEAR LIMITED WARRANTY MOMENT NOW PLEASE TAKE A INSTRUCTION MANUAL AND WARRANTY INFORMATION MP-15-THP

Propane/CNG Solenoid Valve Controller

Transcription:

EN Tank Monitor Instruction manual DTM01 Tank Monitor

1 2 3 1 2 4 3 2 1 4 2

Notes on using the manual Table of contents EN 1 Notes on using the manual 3 2 General safety instructions 3 3 Intended use 4 4 Components and functions 4 5 Specifications 5 6 Installation 6-9 7 Warranty and product liability 11-12 8 Customer service 12 1 Notes on using the manual Caution! Safety Instruction: Failure to observe this instruction can cause material damage and impair the function of the device. Note Supplementary information for operating the device. fig. 2 1, page 2 : This refers to an element in an illustration. In this example, item 1 in figure 2 on page 2. 2 General safety instructions The manufacturer will not be held liable for claims for damage resulting from the following: Faulty assembly or connection Damage to the unit from mechanical influences, misuse or abuse Alterations to the unit without express written permission from the manufacturer Use for purposes other than those described in the operating manual 3

Intended use DTM01 Tank Monitor 3 Intended use (fig. 1, page 2) DTM01 Tank Monitor panel indicates when a wastewater holding tank is almost full. This monitor helps prevent damage to the boat that can happen because of accidental overfilling of the holding tank. Caution! Do not use in fuel tank. 4 Components and functions (fig. 2, page 2) Item Description 1 Probe assembly with float switch 2 #8 fasteners for probe assembly 3 Indicator panel 4 #6 fasteners for indicator panel Probe Assembly with Float Switch The probe assembly installs into a 1.25-inch (32 mm) dia. opening on the top of a Dometic holding tank or other holding tank. As the level of holding tank contents rises, the float switch inside the tank is pushed upward and activates the Full Tank light on the indicator panel. Indicator Panel The indicator panel has a single light which is activated by the float switch inside the holding tank. When the Full Tank light is activated, the operation of any plumbing fixture connected to the holding tank should stop until the tank is emptied. 4 Caution! Operator must know local regulations for emptying a holding tank.

5 Specifications 5.1 Materials Panel frame: ABS Panel: Polyester Float switch: Specifications Nitrile rubber ebonite 5.2 Electrical Current Draw Average current consumption: 0.016 amps at 12 V DC. Requires 0.5-amp fuse. 5.3 Approvals ISO8846; EMC Directive 2004/108/EC 5.4 Dimensions 2 in. (51 mm) 2.5 in. (64 mm) 3.25 in. (83 mm) 3.94 in. (100 mm) 4.5 in. (114 mm) 0.375 in. (10 mm) 2 in. (51 mm) min. clearance behind wall 5

Installation DTM01 Tank Monitor 6 Installation 6.1 Indicator Panel (fig. 3, page 2) 1. Select panel location away from direct contact with water and oil. 2. Confirm clearance for wire connections behind wall, hull liner or bulkhead. 3. Using indicator panel template (fig. 6, p. 9), cut out panel access hole and drill fastener holes. 4. With electrical power off, route 18-gauge stranded copper wire from power source, through 0.5 amp fuse (not provided), to panel location. Route 18-gauge stranded copper wire from holding tank probe assembly to panel location. Make sure wires extend out through access hole (fig. 3 2, p. 2). 5. Install mounting frame (fig. 3 1, p. 2) with four #6 fasteners (provided). 6. Make proper 12 or 24 V DC wiring connections to indicator panel. Refer to wiring diagram (fig. 5, below). 7. Push indicator panel onto mounting frame until it locks into place. 5 Caution! Do not install indicator panel in an atmosphere with potentially flammable or explosive vapors. 6

Installation 6.2 Probe Assembly (fig. 4, page 2) Caution! Do not use probe assembly in fuel tank. Never install the probe assembly with float switch in tank that contains anything other than wastewater, gray water or fresh water. Note For installation in sailboats: Locate probe assembly on athwartships centerline of tank to assure accuracy when heeled. 1. Route 18-gauge stranded copper wire from DC Ground source to probe assembly. 2. Using quick-disconnect terminals, make proper wiring connections from DC Ground source and indicator panel to probe assembly wires. Refer to wiring diagram (fig. 5, page 6). 3. Select probe assembly location away from other tank fittings. Drill 1.25-in. (32 mm) dia. hole in top of tank. 4. Place probe assembly into center of hole. Mark four fastener locations at corners. Remove probe assembly from hole. 5. Drill fastener holes with 1/8-in. (3 mm) drill bit. 6. With probe assembly removed from tank, turn on electrical power to system. Move black float up and down to assure proper operation of float and indicator light. Red indicator light should illuminate when float is pushed up. After successful test, turn off electrical power and disconnect wires at quick-connect terminals. 7. Place probe assembly into hole in top of holding tank. Use four #8 fasteners (provided) to secure probe assembly into holding tank (fig. 4, page 2). Re-connect wires and turn on electrical power. 7

THIS PAGE IS INTENTIONALLY BLANK. 8

Indicator panel template 6 9

THIS PAGE IS INTENTIONALLY BLANK. 10

Warranty 7 Warranty and product liability North America Manufacturer s One-Year Limited Warranty Dometic Corporation, Sanitation Systems (Dometic) warrants to the original purchaser only that this product, if used for personal, family or household purposes, is free from defects in material and workmanship for a period of one year from the date of purchase. If this Dometic product is placed in commercial or business use, it will be warranted to the original purchaser only to be free of defects in material and workmanship for a period of ninety (90) days from the date of purchase. Dometic reserves the right to replace or repair any part of this product that proves, upon inspection by Dometic, to be defective in material or workmanship. All labor and transportation costs or charges incidental to warranty service are to be borne by the purchaser-user. EXCLUSIONS IN NO EVENT SHALL DOMETIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, FOR DAMAGES RESULTING FROM IMPROPER INSTALLATION, OR FOR DAMAGES CAUSED BY NEGLECT, ABUSE, ALTERATION OR USE OF UNAUTHOR- IZED COMPONENTS. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WAR- RANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF ONE YEAR FROM DATE OF PURCHASE. IMPLIED WARRANTIES No person is authorized to change, add to, or create any warranty or obligation other than that set forth herein. Implied warranties, including those of merchantability and fitness for a particular purpose, are limited to one (1) year from the date of purchase for products used for personal, family or household purposes, and ninety (90) days from the date of purchase for products placed in commercial or business use. OTHER RIGHTS Some states do not allow limitations on the duration of an implied warranty and some states do not allow exclusions or limitations regarding incidental or consequential damages; so, the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. To obtain warranty service, first contact your local dealer from whom you purchased this product or go to http://www.dometic.com/enus/americas/usa/customer- Support/ for a dealer near you. 11

Warranty DTM01 Tank Monitor Europe: Warranty Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned. For warranty or other service, please contact our Dometic Service department listed elsewhere in this manual. Any damage due to improper use is not covered by the warranty. The warranty does not cover any modifications to the product or the use of nonoriginal Dometic parts; the warranty does not apply if the installation and operating instructions are not adhered to and no liability shall be entertained. Product Liability Product liability of Dometic Group and its subsidiary companies does not include damages which may arise from: faulty operation; improper alterations or intervention in the equipment; adverse effects from the environment which may impact the equipment itself or the direct vicinity of the equipment or persons in the area. To obtain warranty service, first contact your local dealer from whom you purchased this product or go to http://www.dometic.com/enuk/europe/united-kingdom/ Customer-Center/ for a dealer near you. 8 Customer service There is a strong, worldwide network to assist in servicing and maintaining your toilet system. For the Authorized Service Center near you, please call from 8:00 a.m. to 5:00 p.m. (ET) Monday through Friday. You may also contact or have your local dealer contact the Parts Distributor nearest you for quick response to your replacement parts needs. They carry a complete inventory for the SeaLand product line. Telephone: 1 800-321-9886 U.S.A. and Canada 330-439-5550 International Fax: 330-496-3097 U.S.A. and Canada 330-439-5567 International Web sites: http://www.dometic.com Registered; Trademark of Dometic Corporation Dometic Corporation 600346554 03/13 12 DOMETIC CORPORATION SANITATION SYSTEMS 13128 SR 226 PO BOX 38 BIG PRAIRIE, OHIO 44611 USA www.dometic.com