CONDUCTIVITY MONITOR AND CONTROLLER

Similar documents
BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

2-ELECTRODE CONDUCTIVITY SENSORS

4-ELECTRODE CONDUCTIVITY SENSORS

Analog Condensate Monitor Instruction & Maintenance Manual

SUPERPLUS WATER FILTRATION SYSTEM

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

OWNERS REFERENCE MANUAL

RP-4000 Reserve Power Control

Pre-plumbed Blowdown Assembly ½ Model

RESISTIVITY MONITOR/CONTROLLERS

Rosemount 402 and 402VP

Model LA 4400 Time Delay OFF Controller

EV-2051-M Electric Motor. Operation and Maintenance Manual

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

JET METER INSTRUCTIONS

3D TRASAR Automation - Boiler Blowdown Equipment

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

MAXIGARD A2000 SPEED SWITCH. Introduction

Manual. Series 2EZ. Installation Maintenance Repair Manual

Model 116 DPI Switch Installation and Operating Instructions

Signet Conductivity/Resistivity Electrodes

MicroTron Series C. Manual. Installation Maintenance Repair. Manual. Chemical Metering Pump

AD-830. Parts Manual thru 1997

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

CTFRP Series Power Supplies

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

MA-5200 Series MA-5300 Series

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

OWNERS MANUAL JANUARY 2007 ISO

FIXED DEPTH INSERTION METER INSTRUCTIONS

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

THREE RANGE DS METERS Operation Instructions

ADI-125/750 ADI-125/1500 ADI-125/2500

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

100 Gallon 4- Wheel Sprayer

Snapshot. User Manual BOB LED

Nordson Airless Nozzle Tester

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

! Warning, refer to accompanying documents.

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP

SOFT TOUCH FOR PNEUMATIC RIVETERS

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Signet Conductivity/Resistivity Electrodes

ME AGS Auto Gen Start System for Coach Generators. Operator s Manual.

Buxco Bias Flow Manual

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

DIVERTER AND CHECK VALVES 1-1/2 IN. AND 2 IN. 2-WAY, 3-WAY AND CHECK

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

BITZER Capacity Controller for CSH Compressors Temperature Sensor

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

Manual. MicroTron. Series C. Installation Maintenance Repair Manual. Chemical Metering Pump

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

Installation Manual v1.0: Aurora Plus Turbo Kit ( ) 5.9L Dodge. Please read all instructions before installation.

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

Battery Powered Hydraulic Pump; Kit PN [ ]

Constant Flow Valves. Specifications Sizes: PVC: 1/2", 3/4", 1", 2", 3", 4" CPVC: 1" and 2" Body: Bonnet: Models: Seals: Springs:

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Refinery Supply Company, Inc.

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

System 350 P352AB Electronic Pressure Control Series

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

DIGITAL GLYCOL FEEDER

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

EZ SDI TM Booster Pump Assembly

Mizer Single Pump and Starter Box

Enclosed Electric Rotary Screw Compressor Installation Guide

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Ratio Feeder DB & DD Series Injectors

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

TC62D Installation Instructions

65 Series. Valve Operation Manual

DC to AC Power Inverters

DC to AC Power Inverters

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Model LA 4300 Time Delay OFF Controller

GLOBE FLOWCELL. Operating Manual. Rola-Chem Flowcell PN /01/2013 page: 1 of 8

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

ETF-600 Sensor Operated Lavatory Faucet

POWER COLOR FAST STOP OFF SLOW. AfterDark IMPORTANT INFORMATION

Electric Reciprocating Compressor. Installation Guide

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Manual No: Revision: F. Mag Probe Assembly Manual

Automotive Air Conditioning Manifold Gauge Sets

DIVERTER AND CHECK VALVES 1-1/2 IN. AND 2 IN. 2-WAY, 3-WAY AND CHECK

Chapter Page. 1 Introduction Description 1

Model 616 Rotating Disk Electrode Instruction Manual

Service Manual for Battery Control Center

Atmospheric Consistometer # (115V) # (220V) Instruction Manual. Updated 1/25/2018 Ver. 6.0

4&5 RANGE CONDUCTIVITY METERS Operation Instructions

Model 6275RC 50% Duty Cycle Compressor

SECTION 3. PARTS INFORMATION

Transcription:

LAKEWOOD INSTRUMENTS MODEL 267 CONDUCTIVITY MONITOR AND CONTROLLER INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI 53224 USA Phone (800) 228-0839 Fax (414) 355-3508 http://www.lakewoodinstruments.com

Model 267 Instruction Manual 2

Lakewood Instruments Congratulations on your purchase of a Lakewood Instruments controller. We would like to take this opportunity to welcome you to the Lakewood Instruments product family. With proper care and maintenance, your controller should give you many years of trouble-free service. Please take the time to read and understand the operation manual, paying special attention to the sections on INSTALLATION and MAINTENANCE. If, in the future, any parts or repairs are required, we strongly recommend that only original replacement parts be used. Our Customer Service Department would be happy to assist you with your parts or service requests. We thank you for your selection and purchase of an Lakewood Instruments product. Model 267 Instruction Manual 3

Model 267 Instruction Manual 4

MODEL 267 Table of Contents INTRODUCTION 7 Ordering Information 8 Operation 8 Front Panel Controls 8 INSTALLATION 10 Checking 10 Mounting 10 Plumbing 10 Wiring 10 START-UP 11 Checking 11 Setup and Calibration 11 Establishing Setpoint 12 MAINTENANCE AND TECHNICAL SERVICE 13 Technical Service 13 Service Guide 13 Troubleshooting 14 DRAWINGS 17 Model 267 Instruction Manual 5

Model 267 Instruction Manual 6

INTRODUCTION MODEL 267 CONDUCTIVITY MONITOR AND CONTROLLER The Model 267 is a conductivity monitor and controller. It may be used in condensate systems or process water applications where the conductivity range is less than 100 µs. It will operate at a range of 0-100 µs. Custom ranges are available in 0-25 µs and 0-50 µs. The conductivity sensor comes with a ¾ MNPT and will operate at 400 F and 70 psi. Sensor Material 316 SS Max. Temp 400 F Max. Pressure 70 psi Cond. Range 0-100 µs SPECIFICATIONS Controller Enclosure Cond. Range Resolution Accuracy Power Relays ABS Plastic 0-25 µs, 0-50 µs and 0-100 µs (standard). 1 µs (0-100 µs range). ±5 µs (0-100 µs range). 120 VAC, 50/60 Hz; 240 VAC, optional. 5 Amps @ 120 VAC Model 267 Instruction Manual 7

Ordering Information 267 Monitor/Controller with 0-100 µs sensor and ¾ MNPT inline compression fitting. Custom Range (optional, select one only) CR2 0-25 µs scale. CR5 0-50 µs scale. Sensor Process Connection (optional) 1167375 316 SS ball valve with 1 process connection. This retractable option allows user to remove sensor without disturbing process. Operation The Model 267 measures the electrical conductance of your sample water to determine the level of TDS in your system. The level of conductance is expressed in either a micromhos (µmhos) or a microsiemens (µs) value. When the level of water conductivity demonstrates a level of TDS that exceeds the predetermined setpoint value, then the Model 267 triggers a blowdown of the system and dumps some of the water into the drain. Makeup water is added, which dilutes, and thus reduces, the TDS levels. Front Panel Controls The Model 267 controller features two front panel lights and two adjustments. The two lights are POWER and OPERATE. POWER OPERATE ON when there is power to the controller ON when the conductivity exceeds the front panel setpoint and blowdown occurs Model 267 Instruction Manual 8

The two controller adjustment options are: 1). SETPOINT Establishes the desired level of conductivity to be maintained. When the conductivity level exceeds the setpoint, blowdown occurs. Once the setpoint level is achieved, the controller shuts down the blowdown process. Consult your water treatment engineer to establish the proper setpoint for your system. 2). CALIBRATION Allows you to calibrate the controller to match the actual condensate water conductivity. Pushing the SIMULATOR button substitutes a fixed 50 µmhos value in place of the sensor. This can be used to easily verify controller operation and calibration changes. Model 267 Instruction Manual 9

INSTALLATION Checking Inspect the shipping carton for obvious external damage. Note on the carrier's bill-of-lading the extent of the damage, if any, and notify the carrier. Save the shipping carton until your controller is started up. If there was shipping damage, call the Lakewood Instruments Customer Service Department at (800) 228-0839 and return the analyzer to the factory in the original carton. Mounting Mount the controller on a FLAT, NON-VIBRATING wall. Avoid drilling or punching additional holes in the analyzer enclosure. Damage incurred as a result of any alteration to the enclosure is not covered under the Lakewood Instruments product warranty. NOTE: EXCESSIVE HEAT AND/OR DIRECT SUNLIGHT EXPOSURE WILL DARKEN THE LCD DISPLAY SCREEN, MAKING IT DIFFICULT TO READ, AND MAY SHORTEN THE LIFE OF OTHER ELECTRONIC COMPONENTS. Plumbing Condensate Monitoring Make sure you locate the sensor where the pipe is ALWAYS full of water. The controller diverts contaminated condensate to waste and keeps it out of the boiler. Always install the sensor in the bottom of a U to make sure the pipe is full. WARNING: DO NOT USE PVC OR CPVC PLUMBING. Wiring See drawings for wiring instructions. Model 267 Instruction Manual 10

Start-Up Checking Check the power wiring. Make sure that the controller is powered from 120 VAC, unless it is specifically set up for 240 VAC. Check the wiring to the blowdown solenoid valve. Make sure that the solenoid or ball valve is wired internally through the conduit knockouts to the VALVE OPEN terminal lug. Make sure that the sensor has been attached according to the suggested installation drawing. After you turn the flow on, check the plumbing for leaks. Setup and Calibration The Model 267 Controller is designed for ease of use. We have provided a few optional methods of calibrating so you can select the one best suited to your needs: EXAMPLE 1: USE A HAND-HELD CONDUCTIVITY METER You can use a Lakewood Instruments calibrated hand-held conductivity meter, a Myron L unit or other similar meters. Take a sample of the water. If you have one, use a sample valve spout to get the water directly from the inlet flow line. Let the water run for a few seconds to get a good sample. Measure the water conductivity level with the meter. Take careful note of the level. For the purposes of this example, the level is 25 µmhos. Then turn the conductivity CALIBRATE screw on the front panel very slowly until the conductivity on the LCD matches that on the hand-held meter. You can verify that the calibration is correct by turning the setpoint dial knob very slowly to 26 µmhos and then back to 24 µmhos to make sure the OPERATE light goes OFF at 26 µmhos and ON at 24 µmhos. Model 267 Instruction Manual 11

EXAMPLE 2: USE THE SIMULATOR Set the CALIBRATE screw so it points straight up. Press the SIMULATOR pushbutton. Adjust the CALIBRATE until the display reads 50. Verify operation of the controller with the pushbutton pushed in. NOTE: THIS IS A ROUGH CALIBRATION. USE EXAMPLE 1 FOR GREATER ACCURACY. Establishing Setpoint After you have calibrated the controller, adjust the setpoint to the conductivity level you want to maintain. Consult with your water treatment engineer to determine the proper level for your system. Model 267 Instruction Manual 12

Maintenance and Technical Service Technical Service Technical Support for Lakewood Instruments can be reached by calling (800) 228-0839 or faxing (414) 355-3508, Monday through Friday, 7:30 a.m. - 5:00 p.m. CST. Mail and returns should be sent to: Lakewood Instruments 7838 North Faulkner Road Milwaukee, WI 53224 USA When any merchandise is returned to the factory, please call and obtain a Return Goods Authorization (RGA) number and have the following information available: Customer s name, address, phone and fax numbers. A purchase order number (no exceptions) for cases where parts are required that are not under warranty. A contact person s name and phone number to call if the equipment is beyond repair or to discuss any other warranty matter. Equipment model and serial numbers. Reason for return (i.e., repair, warranty, incorrect part, etc.). We will then fax to your attention an RGA form that must accompany the returned item. NOTE: THE RGA NUMBER MUST BE CLEARLY WRITTEN ON THE OUTSIDE OF THE PACKAGE(S) BEING RETURNED. Model 267 Instruction Manual 13

Service Guide When calling Lakewood Instruments, please have the controller s complete model number and serial number available, so that the technician can better assist you. When any parts are returned to the factory, please indicate: Customer s name and address. Individual at customer location to send the repaired controller or new part to. The person (and phone number) to call if the equipment is beyond repair or for any warranty matter. Write your controller s complete model number, serial number, here so that you will have them available if you wish to contact an Lakewood Instruments technician. Model Number: Serial Number: Model 267 Instruction Manual 14

Troubleshooting PROBLEM Controller is inoperative. CHECK 1. Verify that the power outlet is 120 VAC. 2. Plug in the power cord and check 120 VAC across terminal block TA lugs 2 and 3. 3. Check continuity through the 10 Amp fuse on the rear circuit board. The fuse is located above terminal block TA. Conductivity control is inoperative. The OPERATE light comes ON with the setpoint, but the valve does not open. There is no conductivity reading above 0. 1. Make sure there is flow so the sensor is in water. 2. Turn the setpoint fully counterclockwise to 0. The OPERATE light should come on and the blowdown valve should open. 1. Check for 120 VAC at the blowdown valve terminal when the OPERATE light is ON. 2. Replace the relays if necessary. 3. Refer to the blowdown valve instructions and thoroughly check the valve and wiring. 1. Refer to the maintenance section to clean the sensor. 2. Push the SIMULATOR pushbutton. Does the controller work at 50 µmhos? 3. Replace the conductivity sensor. Controller drifts downward over a long time. 1. Is the sensor clean? 2. Is the sample flow rate too low? Replacement Parts P/N Description 1167087 Conductivity Sensor 540K.1-4-105-18-TC500 Model 267 Instruction Manual 15

For more information call toll free in the USA (800) 228-0839 Manufactured in the USA Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI 53224 USA Phone (414) 355-2807 Fax (414) 355-3508 http://www.lakewoodinstruments.com