AIR COOLED RECTIFIER SPECIFICATION S-50-A

Similar documents
SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

SECTION MOTOR CONTROL

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

AT30 SERIES BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

A. Submit manufacturer's literature and technical data before starting work.

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

HIGH POWER RECTIFIER SYSTEMS

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

MaxPak Plus Analog DC V S Drive

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

825-P Modular Protection System for motors Specification Guide

Product Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

ATevo SERIES BATTERY CHARGER

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

SUBSTATION EQUIPMENT - Page 1 of 8

AT EVO SERIES BATTERY CHARGER

A1P OPERATING MANUAL

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

PROCESS ELECTRONICS CORPORATION

SDC,Inc. SCR-Regenerative Ac Drive

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Unit Substation Transformers 5 and 15 KV Class

SECTION MOTOR CONTROLLERS

MAGNETIC MOTOR STARTERS

Sola/Hevi-Duty S3K Series Mini-Tower UPS

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Liebert PowerSure PSI UPS

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

PROCESS ELECTRONICS CORPORATION

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Generator Fire Safety: Generator assemblies should be located outside the building.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

RVS-DN Digital Reduced Voltage Motor Starter

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

WARREN COUNTY, N.Y. M/E REFERENCE

A6Z OPERATING MANUAL

www. ElectricalPartManuals. com r" n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

Application Description

PVT Series. Peschel Variable Transformer FEATURES BENEFITS APPLICATIONS

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

OTEC Transfer switch open transition

EVO AT SERIES BATTERY CHARGER

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Transfer switch OTEC open or delayed transition

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Electronic voltage regulator. Instruction manual. Effective September 2015 Supersedes August 2013

CHPC Transfer switch closed transition

Design Standard. Purpose: Design Standard:

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

SURE TRIP RETRO KITS

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

A3Z OPERATING MANUAL

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

MOTORTRONICS Solid State AC Motor Control

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

TOSHIBA G , 750kVA

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

AT SERIES EVO BATTERY CHARGER

CTi Automation - Phone: Fax: Web:

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

SINAMICS GM150 IGCT version

SURE-TRIP OEM RELACEMENT TRIP UNIT

SECTION MOTOR CONTROLLERS

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

Functions provided by measuring relays in railway equipment

Transcription:

SPECIFICATIONS AIR COOLED RECTIFIER Spec50a1 5JAN1999 SPECIFICATION S-50-A HIGH VOLTAGE SINGLE TRANSFORMER AIR COOLED RECTIFIER Standard output power range: 250 to 600 volts at 100 to 1,200 amperes TECHNICAL SPECIFICATIONS General Standards The following specification describes Controlled Power s high voltage single transformer secondary thyristor (SCR) DC power supply. All systems are designed and built to assure maximum reliability, flexibility, serviceability and performance. Controlled Power meets the individual needs of their customers through options and system customizing. The D. C. Power Supply is designed and manufactured in accordance with the following where applicable: National Electric Code (NEC) current edition American National Standards Institute (ANSI) National Fire Protection Association (NFPA-70) National Electrical Manufacturers Association (NEMA) Performance Specifications Input Voltage Standard Voltages: 240 or 480 Volts, 3 Phase. Optional Voltages: 208, 380 or 600 Volts, 3 Phase. Input Line Variation Standard: +5% from nominal. Optional wider ranges available. Frequency Standard: 60 hertz. Optional: 50 hertz. Efficiency Between 90% and 93% Power Factor Typically 90% at full output Reliability 16,598 hours (MTBF) Voltage Regulation + 0.5% Current Regulation + 0.5% Ambient 0 º C (32 º F ) to 40 º C (104º F) Maximum Humidity 95% non-condensing. Elevation Maximum elevation 5000 feet (1524 meters). Storage -20 C (-4 F) to 50 C (122 F) 1

Regulation Solid state regulation of the output power is accomplished by means of Thyristors (silicon controlled rectifier, SCR), a solid state device with extremely long life, high efficiency and superior power factor. Thyristor regulation provides full range control, with or without a load, affording maximum operating flexibility and minimum maintenance. Main Transformer The design of the power transformer section of this power supply is of the highest quality and reliability. The power transformer is a ventilated, dry type. The primary circuit is (3) three phase, ungrounded, delta connected. The secondary is wye. ANSI circuit # 23 standard 34.2. The transformer has separate primary and secondary windings, auto-transformer types are not used. All electrical conductor material is high conductive electrolytic copper of not less than 98% of the international annealed standard for conductivity. Insulation is Class 200 (200 C rating), designed to operate within safety margins. The primary is separated from the core and secondary by a double layer arc resistant barrier (nomex) to minimize the possibility of shorts. All transformer leads are supported so that the weight is removed from the coils and they are securely braced to prevent damage in transit and during installation. All cores are manufactured from a high-grade, grain oriented silicon steel with highmagnetic permeability, low hysteresis and eddy current losses. Magnetic flux densities are kept well below saturation to allow for a minimum of 5% over-voltage excitation. All laminations are free from burrs and stacked without gaps. All stand-off or support insulators for both transformer leads and other rectifier bus are glastic materials. Organic material are not used for bus or cable support due to possible deterioration. All transformer coils and connections are thoroughly braced for the magnetic stresses for short circuits of 18.0 times the rated base RMS symmetrical current, phase to phase, or phase to neutral for a period of 3.35 seconds. The transformer is constructed to be capable of withstanding, without damage, the mechanical stresses of an external short circuit or ground fault of this magnitude while rated primary voltage is maintained. Rectifier Circuit Ripple A wye secondary, ANSI circuit No. 23 standard 34.2 is used. Output rectification is by means of Thyristors.(SCR) 5% Rms. AC ripple at unit full output rating. Filtering can be added as an option to reduce the percentage of ripple if required. 2

Cabinet Thyristors The cabinets are all steel construction built to NEMA 1 standards. The metal is pretreated with a phosphate coating and finished with a baked-on enamel paint to resist corrosion, marring or scratching. The thyristors (SCR) are rated for continuous full load operation. An optional auxiliary sensing circuit is available to detect a phase imbalance in the unlikely event of a device failure. This circuit insures no fault load will be placed on the remaining devices. The thyristor assembly is designed for a maximum junction temperature not to exceed 80% of the maximum rated junction temperature of the device to prolong the life of the device. The peak inverse and forward voltage ratings of the devices are at least 2 ½ times the peak voltage of the AC supply. The devices are mechanically clamped and mounted to an extruded heat sink in a manner which insures less than 10 C difference between the device and the heat sink. The heat sink is designed to provide proper cooling and to limit the maximum temperature rise to 40 C. This design is in conjunction with the appropriate air CFM maintained on the heat sink. The heat sink is machined to exceed thyristor manufacture specifications. Transient voltage surge protection limits the maximum transient voltage to less than 2.5 times the peak inverse voltage of the device. This protects each device from surges caused by switching and other alternating current variables. Primary Protection Cooling Controls Primary protection is provided by means of an AC Thermal Magnetic Circuit Breaker. This breaker is sized to interrupt the fault current of normal installations. An optional fast acting AC current unbalance circuit which shuts the rectifier down under fault conditions is available. Cooling is accomplished by circulating ambient air across the heat generating components with axial fans. The operator s control panel is on the door of the control enclosure and includes the volt meter, ammeter, control potentiometer, volt/amp switch, start/stop/power off push buttons and some option components may also be included. 3

Automatic Controls MICROPROCESSOR BASED CONTROL SYSTEM This system provides accurate repeatability and programmable features. CONSTANT VOLTAGE CONTROL This control maintains the preset output voltage constant to within +0.5%. The control limits the output of the DC power supply to a safe level if an excessive load is placed on the power supply. CONSTANT CURRENT CONTROL This control maintains the selected output current constant to within +0.5% over a 10-100% voltage range with varying input voltages and loads. If the load is removed, the voltage will rise to a preset limit value. DC OVERLOAD Digitally enhanced overload circuit allows selection of one of four settings from zero (0) to three (3) restart attempts once excessive output current is detected. Upon overload detection, the circuitry will disable the DC output, ramp the output back to it s set level within five (5) seconds and continue operation without interruption as long as the excessive load has cleared. Upon exceeding the selected number of restart attempts if the excessive load has not been cleared the unit will shut down. The overload level is factory adjusted for 5% over the units rated current output. OPTIONAL CONTROLS Fast acting AC current unbalance circuitry detects AC current unbalance and shuts down the DC power before serious damage may occur. Automatic slope is digitally stepped to ramp the DC power at an adjustable rate. One (1) of two (2) standard time frames may be selected. Zero (0) to two (2) minutes or zero (0) to twenty (20) minutes. Optional longer times frames are available. Signal conditioners fully isolate interface signals to control and monitor the DC output. One of the following signals may be specified 4-20 miliamp, 0-10 volt or 0-5 volt. Amp Hour Counter allows the accumulated ampere-time product to be continually monitored for chemical replenishment or maintenance scheduling. Parallel control circuit for balanced operation allows two (2) or more units to be operated in parallel for increased current output levels to a load. Cycle timer with optional alarm for time controlled operation. Command two level control for conveyor stopped low level output setting. 4

Gating Circuitry DC Output Warranty SOFT START The output voltage is ramped from zero (0) to the set value in a minimum of 300 milliseconds by electronic circuitry limiting damaging current surges at start-up. SYNCHRONIZATION A Phase Lock Loop circuit digitally produces synchronized gating signals for proper gating and insures that all phases are present before gating commences. INHIBIT CIRCUITS (optional) A potential free contact controlled circuit can disable the gate card to remove gate signals from the thyristors. (Contact closure enables the gate signals). An automatic absolute zero gate inhibit circuit board will disable gate signals and suppress leakage whenever the output is set for zero (0) in voltage or current mode of control. The DC output of the unit is floating. Either terminal may be grounded. The system is guaranteed against defects in material and workmanship for one (1) year from the date of shipment. 5