Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Similar documents
LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switch - Prewired Type Metal Body

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches Metal casing, 40mm & 60mm Assembled Components

FOOT SWITCHES

Comepi Limit Switches

Safety Limit Switches

FL series position switches

AF40... AF96 3-pole contactors Technical data

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Gross Automation (877)

FOOT SWITCHES IN THERMOPLASTIC MATERIAL AND ALUMINIUM DIE CAST PS... / PD... SERIES. Symbols P S / P. Dimensions (in mm)

Position switches FD series

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Compact plastic limit switches with positive opening mechanism

PRODUCT SPECIFICATION. Foot Switches. Series.

ASL09..S 3-pole Contactors - Spring Terminals

Compact plastic limit switches with positive opening mechanism

Safety switches for hinged doors

Position switches FR series

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Single foot switches PX and PA series

Safety switches for hinges

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Prewired position switches FF series

Position switches FR series

Description. Positive safety relays

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Compact Limit Switches

Miniaturized limit switches

Safety Limit Switch

Safety switches with separate actuator

LK Position Switches TECHNICAL DATASHEET.

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Safety switches with separate actuator

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Position Switches Series 8070/2

Hinged Safety Door Switch

AE 9... AE 40 Contactors NE... Contactor Relays

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Prewired position switches FF series

Pre wired limit switches

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Limit switches 3. Page 92. Page 92

Switches with manual reset

SFS-UFS Single Foot Switches

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

DP_T Limit Switches. Double Insulation Plastic Casing IP65-50 mm. width. T1 - Plain plunger T10: nylon plunger T11: metal plunger 0,5 15 /

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Microswitches M series

L S T E 4 1 L S A 4 0 X 5 4

Position Switches Series 8060/2

Position switches FC series

LR-LX-LK-LW Safety Switches with separate actuator

TAE pole Contactors

XACA871 pendant control station XAC-A - 8 pushbuttons

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Electronic overload relay EF65, EF96 and EF146

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Short form catalogue. Motor protection & control

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Safety rope switches with reset for emergency stop

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Safety rope switch with reset for emergency stop

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

K50H004UP cam changeover switch - 4-pole A - screw mounting

Safety switches for hinged doors

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

Microswitches MK series

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons

K30H001YP cam star-delta switch - 3-pole A - screw mounting

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Single foot switches PX and PA series

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Position Switches Series 8074/2

IEC Limit Switches Selection Guide

Electronic overload relays EF205 and EF370

Safety rope switch without reset for simple stop

Star Series Motor protection & control

IEC Limit Switches Selection Guide

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

General_technical_data Series

Transcription:

Limit switches pre-wired 3mm & 35mm Metal & plastic casings Limit switches Description Plastic are made of reinforced UL-VO thermoplastic fiberglass, offering double insulation <square image> and protection of IP67 and NEMA Type 1. Metal are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X. Casings come in 2 dimensions: 3mm width 35mm width Applications Easy to use, electromechanical offer specific qualities: Visible operation Able to switch strong currents (5A thermal) Electrically separated contacts ( shape) Precise operating points (consistency) Immune to electromagnetic disturbances Limit switches used for these mechanical applications: Presence/absence Positioning and travel limit Objects passing/counting UL Listed file #E1163 Low Voltage Products & Systems.63 ABB Inc. -35-21 www.abb.us/lowvoltage 1SXU23C22

General information Metal & plastic Pre-wired Description LS2P... LS26P, made of fiberglass reinforced UL-V thermoplastic material, sealed with epoxy resin at the base on the body, offer double insulation and a degree of protection IP67, NEMA Type 1. LS2M... LS26M, made of zinc alloy (zamack), sealed with epoxy resin at the base on the body, offer a degree of protection IP67, NEMA 4, 4X. The casings come in 2 dimensions: LS2... LS21, 3 mm width, LS... LS26, 35 mm width. Applications Easy to use, electromechanical offer specific qualities: Visible operation. Able to switch strong currents (5 A conventional thermal current). Electrically separated contacts ( shape). Contact blocks with positive opening operation of the N.C. normally closed contact(s) (symbol ). Precise operating points (consistency). Immune to electromagnetic disturbances. They are exceptional detection devices thanks to these characteristics: Presence/absence. Positioning and travel limit. Objects passing/counting. A variety of operating heads: Plain plunger Roller plunger Roller lever, adjustable or not, etc. Assembled using 2 x ø3 screws for LS2P...LS26P Assembled using 2 x M3 screws for LS2M...LS26M Casing: 3 mm or 35 mm width Contact blocks: Contact configuration: 1 N.O. + 1 N.C. Positive opening operation Snap action or slow action shape: the 2 contacts are electrically separated Mounting the casing: 2 x M4 screws on the top part Electrical connection: Cable output left/right or cable output bottom: for LS2P...LS26P - cable IEC 2/22 II PVC 4 x.75 mm² - cable UL 62 PVC 4 x AWG 1 for LS2M...LS26M - cable IEC 2/22 II PVC 5 x.75 mm² - cable UL 62 PVC 5 x AWG 1 Standard length: 1 m (other lenghts on request) Other outputs (on request): - connector M or 7/" NPT - cable with end connector Compounding with epoxy resin for IP67 protection degree Catalog number explanation Example : L S 2 5 M 51 D 11 U 2 Limit Switch, prewired...ls2 3 mm width: cable output left / right... 3 mm width: cable output bottom... 1 35 mm width: cable output left / right... 5 35 mm width: cable output bottom... 6 Cable length: 1...1 m 2...2 m 3...3 m 5...5 m 1...1 m (Max. for UL cable) U... cable UL 62 - PVC Contact types: 11... 1 N.O. + 1 N.C. contacts Plastic casing... P Metal casing...m Operating heads: Codes...1... Snap action: B... Snap Dependent (slow) action: D... Non-overlapping late make.64 Low Voltage Products & Systems 1SXU23C22 ABB Inc. -35-21 www.abb.us/lowvoltage

Assembled Plastic casing (NEMA1) & metal casing - (NEMA 4, 4X) Pre-wired, 3mm Movement to be detected: On end 3 Cam Trans. On end For Plastic Casing: Cable: 4 x.75 mm 2 / 4 x AWG 1 For Metal Casing: Cable: 5 x.75 mm 2 / 5 x AWG 1 Actuator Metal plunger Metal Roller plunger Metal plunger Metal plunger (with dust protection cup) with fixing nuts (N.C. contact with positive opening operation) Maximum actuation speed.5 m/s.1 m/s.5 m/s.5 m/s Min. force / torque: - actuation 15 N 1 N 15 N 15 N - positive opening operation 3 N 3 N 3 N 3 N Additional technical data Cable output left / right code... } Does not affect pricing. Cable output bottom code... 1 Plastic casing... P Metal casing... M Type to be completed with the above codes Snap action contacts Catalog number LS2 11B11- U 1 LS2 B11- U 1 LS2 16B11- U 1 LS2 21B11- U 1 List price (plastic/metal) $ 66 $ 66 $ 75 $ 1 $ 74 $ $ 7 $ 76 1. 1. 4. 5. mm 1.7 3.3 6..7 mm 1. 1. 4. 5. mm 1. 1. 4. Non-overlapping Catalog number LS2 11D11- U 1 LS2 D11- U 1 LS2 16D11- U 1 LS2 21D11- U 1 Slow action contacts List price (plastic/metal) 66 72 75 1 74 76 76 74 1. 3.4 5. mm Weight 2 (packing per unit) kg.1.13.1.14 3.3 5..7 mm 1. 3.4 5. mm 1. 3.4 5. mm 5. mm Closed contact / Open contact Dimensions (mm) 3 2 16 31.5 L133D 3 4 2 L1316D 4 O.2 Tightening torque of nuts : 5 N.m Distance between nuts : mm Nuts thickness : 3 mm L132D 11 2 6 L1D 21 L6D 3 7 L7D 3.5 2.5 LD Mx1 34 L133D 74 L134D 7 2.5 6.5 L147D L146D 1 Other cable lengths available. Replace last two digits 1 with: 2-2m, 5-5m, 1-1m. 2 add.5 kg with metal casing. Low Voltage Products & Systems Discount schedule RM [LI].65 ABB Inc. -35-21 www.abb.us/lowvoltage 1SXU23C22

Assembled Plastic casing (NEMA1) & metal casing - (NEMA 4, 4X) Pre-wired, 3mm Movement to be detected: 3 Cam Translation Movement Multidirectional For Plastic Casing: Cable: 4 x.75 mm 2 / 4 x AWG 1 For Metal Casing: Cable: 5 x.75 mm 2 / 5 x AWG 1 Actuator Metal Roller plunger ø14 plastic roller lever Adjustable ø1 Spring rod with fixing nuts plastic roller lever (N.C. contact with positive opening operation) Maximum actuation speed.1 m/s 1.5 m/s 1.5 m/s 1. m/s Min. force / torque: - actuation 1 N. N.m. N.m.1 N.m - positive opening operation 3 N.2 N.m.2 N.m Additional Technical Data Cable output left / right code... } Does not affect pricing. Cable output bottom code... 1 Plastic casing... P Metal casing... M Type to be completed with the above codes Snap action contacts Catalog number LS2 22B11- U 1 LS2 41B11- U 1 LS2 51B11- U 1 LS2 1B11- U 1 List price (plastic/metal) $ 7 $ 5 $ 6 $ 73 $ 7 $ 75 $ 74 $ 1.7 3.3 6..7 mm 14 26 5 74 14 26 5 74 5 14 Non-overlapping Catalog number LS2 22D11- U 1 LS2 41D11- U 1 LS2 51D11- U 1 - Slow action contacts List price (plastic/metal) 7 5 6 73 7 75 3.3 5..7 mm Weight 2 (packing per unit) kg.145.175.1.1 27 45 74 27 45 74 - Closed contact / Open contact Dimensions (mm) 3 4 4 2 31.5 3 2 L1316D O.2 L132D 16 L133D Tightening torque of nuts : 5 N.m Distance between nuts : mm Nuts thickness : 3 mm 35. Mx1 44. 1.4 L135D 4. 3.5 L136D 52 3 O 14 1 27 L13D 2 66.5 24 L131D 2.5 4...11 3 O 1 1 1...1...15 L1313D 66.5 34.4 36.1 3. 6.5 L1314D 141.5 7 L1323D 11.5 L1324D 1 Other cable lengths available. Replace last two digits 1 with: 2-2m, 5-5m, 1-1m. 2 add.5 kg with metal casing..66 Discount schedule RM [LI] Low Voltage Products & Systems 1SXU23C22 ABB Inc. -35-21 www.abb.us/lowvoltage

Assembled Plastic casing (NEMA1) & metal casing - (NEMA 4, 4X) Pre-wired, 35mm Movement to be detected: On end 3 Cam Trans. On end For Plastic Casing: Cable: 4 x.75 mm 2 / 4 x AWG 1 For Metal Casing: Cable: 5 x.75 mm 2 / 5 x AWG 1 Actuator Metal plunger Metal Roller plunger Metal plunger Metal plunger (with dust protection cup) with fixing nuts (N.C. contact with positive opening operation) Maximum actuation speed.5 m/s.1 m/s.5 m/s.5 m/s Min. force / torque: - actuation 15 N 1 N 15 N 15 N - positive opening operation 3 N 3 N 3 N 3 N Additional Technical Data Cable output left / right code... 5 } Does not affect pricing. Cable output bottom code... 6 Plastic casing... P Metal casing... M Type to be completed with the above codes Snap action contacts Catalog number LS2 11B11- U 1 LS2 B11- U 1 LS2 16B11- U 1 LS2 21B11- U 1 List price (plastic/metal) $ 77 $ 3 $ 6 $ 2 $ 5 $ 1 $ 1 $ 7 1. 1. 4. 5. mm 1.7 3.3 6..7 mm 1. 1. 4. 5. mm 1. 1. 4. Non-overlapping Catalog number LS2 11D11- U 1 LS2 D11- U 1 LS2 16D11- U 1 LS2 21D11- U 1 Slow action contacts List price (plastic/metal) 77 3 6 2 5 1 7 1 1. 3.4 5. mm Weight 2 (packing per unit) kg.1.13.1.14 3.3 5..7 mm 1. 3.4 5. mm 1. 3.4 5. mm 5. mm Closed contact / Open contact Dimensions (mm) 35 4 3 O.2 35 3 4 L1371D 16 Tightening torque of nuts : 5 N.m Distance between nuts : mm Nuts thickness : 3 mm L1372D 3.5 7 Mx1 11 L1334D 2 6 L1335D 21 L1336D 3 7 L1337D 2.5 L145D 2.5 6.5 L144D L1342D 34 74 L1343D O.2 L136D 1 Other cable lengths available. Replace last two digits 1 with: 2-2m, 5-5m, 1-1m. 2 add.5 kg with metal casing. Low Voltage Products & Systems Discount schedule RM [LI].67 ABB Inc. -35-21 www.abb.us/lowvoltage 1SXU23C22

Assembled Plastic casing (NEMA1) & metal casing - (NEMA 4, 4X) Pre-wired, 35mm Movement to be detected: 3 Cam Translation Multidirectional For Plastic Casing: Cable: 4 x.75 mm 2 / 4 x AWG 1 For Metal Casing: Cable: 5 x.75 mm 2 / 5 x AWG 1 Actuator Metal Roller plunger ø14 plastic roller lever Adjustable ø1 Spring rod with fixing nuts plastic roller lever (N.C. contact with positive opening operation) - Maximum actuation speed.1 m/s 1.5 m/s 1.5 m/s 1. m/s Min. force / torque: - actuation 1 N. N.m. N.m.1 N.m - positive opening operation 3 N.2 N.m.2 N.m - Additional Technical Data Cable output left / right code... 5 } Does not affect pricing. Cable output bottom code... 6 Plastic casing... P Metal casing... M Type to be completed with the above codes Snap action contacts Catalog number LS2 22B11- U 1 LS2 41B11- U 1 LS2 51B11- U 1 LS2 1B11- U 1 List price (plastic/metal) $ $ 6 $ 7 $ 4 $ 1 $ 6 $ 5 $ 1 1.7 3.3 6..7 mm 14 26 5 74 14 26 5 74 5 14 Non-overlapping Catalog number LS2 22D11- U 1 LS2 41D11- U 1 LS2 51D11- U 1 - Slow action contacts List price (plastic/metal) 6 7 4 1 6 3.3 5..7 mm Weight 2 (packing per unit) kg.2.2.23.235 27 45 74 27 45 74 - Dimensions (mm) Closed contact / Open contact- 35 3 4 35 3 O.2 L1371D 16 L1372D Tightening torque of nuts : 5 N.m Distance between nuts : mm Nuts thickness : 3 mm 35. Mx1 1.4 44. 3.5 52 3 O 14 27 24 4...11 3 O 1 1...1 66.5 34.4 6.5 141.5 7 11.5 4 L1344D 4. L1345D 1 L134D 2 66.5 L13D 2.5 1 L1352D 36.1 3. L1353D L1362D L1363D O.2 L136D 1 Other cable lengths available. Replace last two digits 1 with: 2-2m, 5-5m, 1-1m. 2 add.5 kg with metal casing..6 Discount schedule RM [LI] Low Voltage Products & Systems 1SXU23C22 ABB Inc. -35-21 www.abb.us/lowvoltage

Technical data Plastic & metal casing 3mm & 35mm General Technical Data Plastic Casing Metal Casing Standards IEC 647-1, IEC 647-5-1, EN 647-1, EN 647-5-1, UL 5 and CSA C22-2 n 14 Certifications - Approvals UL - CSA (only with UL62-151 cable) Air temperature near the device during operation C... + 7... + 7 for storage C 4... + 7 4... + 7 Climatic withstand According to IEC 6-2-3 and salty mist according to IEC 6-2-11 Mounting positions All positions are authorized Shock withstand (according to IEC 6-2-27 and EN 66-2-27) g* (1/2 sinusoidal shock for 11 ms) no change in contact position Resistance to vibrations (acc. to IEC 6-2-6 and EN 66-2-6) g** (1... 5 Hz) no change in position of contacts greater than 1 µs Protection against electrical shocks (acc. to IEC 536) Class II Class I Degree of protection (according to IEC 52 and EN 652) IP67 Degree of protection (according to UL 5 and NEMA) Type 1 Enclosure (indoor use) Type 4-4x - 6 Enclosure (Outdoor use) Consistency (measured over 1 million operations).1 mm (upon closing point) Electrical Data Rated insulation voltage U i according to IEC 647-1 and EN 647-1 V 4 (degree of pollution 3) according to UL 5, CSA C22-2 n 14 V 3 Rated impulse withstand voltage U imp kv 4 (according to IEC 647-1 and EN 647-1) Conventional enclosed thermal current I the A 5 (according to IEC 647-5-1 and EN 647-5-1 ) θ < 4 C Short-circuit protection gg type fuses A 6 Rated operational current I e / AC-15 acc. to IEC 647-5-1 24 V - 5/6 Hz A 5. V - 5/6 Hz A 3. 24 V - 5/6 Hz A 1.5 acc. to UL 5, CSA C22 n 14 B 3 I e / DC-13 acc. to IEC 647-5-1 24 V - d.c. A 1.1 1 V - d.c. A.22 V - d.c. A.1 acc. to UL 5, CSA C22 n 14 R 3 Positivity Contacts with positive opening operation as per IEC 647-5-1 chapter 3 and EN 647-5-1 Resistance between contacts mω Pre-wired connection mm 2 / AWG 4 x.75 mm 2 / 4 x AWG 1 5 x.75 mm 2 / 5 x AWG 1 Type of cable UL 62-151 (PVC) Black - Ø ext. 7.2 +.2 Black - Ø ext..2 +.2 IEC 2/22 II (PVC) (no flame propagation) Black - Ø ext. 7.2 +.2 Grey - Ø ext..2 +.2 Terminal marking According to EN 513 Mechanical durability 1 Millions of operations Electrical durability (according to IEC 647-5-1 appendix C) Utilization categories AC-15 and DC-13 (See curves and values below) max. switching frequency Cycles/h 36 load factor.5 * Shock: g for LS2P/M..,... LS26P/M.. with D11 contact block 5g for LS2P/M..,... LS26P/M.. with B11 contact block **Vibrations: except for LS2P/M3... LS26P/M3 : 15 g Electrical durability for AC-15 utilization category Electrical durability for DC-13 utilization category Snap action Slow action Snap action Slow action Millions of operating cycles 5 3 2 1.5.3.2 23-24 13 4-24 I the Millions of operating cycles 5 3 2 1.5.3.2 23 11-24 - 4 I the Power breaking for a durability of 5 million operating cycles Voltage 24 V 5.7 W 7.2 W Voltage 4 V 4.1 W 5.4 W Voltage 11 V 2.2 W 3.6 W.1.2.3.5 1 2 3 5 1 Current (A).1 1 2 3 5 1 Current (A) Low Voltage Products & Systems.6 ABB Inc. -35-21 www.abb.us/lowvoltage 1SXU23C22

Technical data Plastic & metal casing 3mm & 35mm General Technical Data Plastic Casing Metal Casing Standards IEC 647-1, IEC 647-5-1, EN 647-1, EN 647-5-1, UL 5 and CSA C22-2 n 14 Certifications - Approvals UL - CSA - CCC Air temperature near the device during operation C... + 7... + 7 for storage C 3... + 3... + Climatic withstand According to IEC 6-2-3 and salty mist according to IEC 6-2-11 Mounting positions All positions are authorized Shock withstand (according to IEC 6-2-27 and EN 66-2-27) g 5g* (1/2 sinusoidal shock for 11 ms) no change in contact position Resistance to vibrations (acc. to IEC 6-2-6 and EN 66-2-6) g g (1... 5 Hz) no change in position of contacts greater than 1 µs Protection against electrical shocks (acc. to IEC 536) Class II Class I Degree of protection (according to IEC 52 and EN 652) IP65 IP66 ** Consistency (measured over 1 million operations).1 mm (upon closing point).1 mm (upon closing point) Electrical Data Rated insulation voltage U i according to IEC 647-1 and EN 647-1 V 5 (degree of pollution 3) 4 (LS3..M.. & LS7..M..), 5 (LS4xM..) - (degree of pollution 3) according to UL 5, CSA C22-2 n 14 V 6 3 (LS3..M.. & LS7..M..), 6 (LS4..M..) Rated impulse withstand voltage U imp kv 6 (according to IEC 647-1 and EN 647-1) Conventional enclosed thermal current I the A 1 (according to IEC 647-5-1 and EN 647-5-1 ) θ < 4 C Short-circuit protection gg type fuses A 1 Rated operational current I e / AC-15 acc. to IEC 647-5-1 24 V - 5/6 Hz A 1 13 V - 5/6 Hz A 23 V - 5/6 Hz A 3.1 24 V - 5/6 Hz A 3 4 V - 5/6 Hz A 1. acc. to UL 5, CSA C22 n 14 A 6 A 3 (LS3..M.. & LS7..M..), A 6 (LS4..M..) I e / DC-13 acc. to IEC 647-5-1 24 V - d.c. A 2. 11 V - d.c. A.6 V - d.c. A.27 acc. to UL 5, CSA C22 n 14 Q 6 Q 3 (LS3..M.. & LS7..M..), Q 6 (LS4..M..) Positivity Contacts with positive opening operation as per IEC 647-5-1 chapter 3 and EN 647-5-1 Resistance between contacts mω Mechanical durability Millions 15 3x 1... ; 3...3 15 3x 11... ; 31...3 of 1 LS P 13 ; 41...46 ; 51...55 ; 61...7 1 LS M 13 ; 41...46 ; 51...55 ; 61...7 } } { { operations > 5 7x 14 ; 1...2 ; > 5 7x 14 ; 1...2 ; Millions 15 11 ; ; 31...33 3 11...13 ; 21...23 ; 31...33 of 1 LS 4x P 13 ; 41...44 ; 51...55 ; 61...74 LS 4x M 41...44 ; 51...55 ; 61...74 operations > 5 14 ; 1 ; 34...36 ; 1...3 1 1...3 Electrical durability (according to IEC 647-5-1 appendix C) Utilization categories AC-15 and DC-13 (see curves and values below) max. switching frequency Cycles/h 36 load factor.5 Connecting data of contact blocks Connecting terminals M3.5 (+, ) pozidriv 2 screw with cable clamp Connecting capacity 1 or 2 x mm 2 / AWG.5 mm 2 / AWG 2 to 2.5 mm 2 / AWG 14 Terminal marking According to EN 513 * Except for LS3..M42, M52 and M55 - LS3..P42, P52 and P55 - LS7..M42, M52 and M55 - LS7..P42, P52 and P55: g ** Except for LS3..M52, M55, M73, M74 and M2 - LS7..M52, M55, M73, M74 and M2 - LS4..M54, M72, M2 and M3 : the degree of protection is IP65. Electrical durability for AC-15 utilization category Electrical durability for DC-13 utilization category Snap action Slow action Snap action Slow action } } { { Millions of operating cycles 5 3 2 1.5.3.2 23-24 4 13 4-24 Millions of operating cycles 5 3 2 1.5.3.2 23 13 4-24 Power breaking for a durability of 5 million operating cycles Voltage 24 V.5 W W Voltage 4 V 6. W W Voltage 11 V 3.6 W 6 W.1.2.3.5 1 2 3 5 1 Current (A).1 1 2 3 5 1 Current (A).7 Low Voltage Products & Systems 1SXU23C22 ABB Inc. -35-21 www.abb.us/lowvoltage