DP140e. Installation & Operations Manual

Similar documents
Installation and Operations Manual

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Back-UPS BX550CI-CN

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Back-UPS CS Back-UPS CS 350

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

BULL POWER Line Conditioner Regulating Power Bar

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

CTFRP Series Power Supplies

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Installation and Operation Manual Back-UPS BR1000-CH

ADI-125/750 ADI-125/1500 ADI-125/2500

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Getting Started With Your System

Innovative Circuit Technology Ltd.

OWNERS MANUAL JANUARY 2007 ISO

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

Uninterruptible Power System

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

The Power of Reliability INSTRUCTION MANUAL

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

DC to AC Power Inverters

DC to AC Power Inverters

3000VA 120/208/230VAC

ST Charger. Industrial Battery Charger

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual

BR62 Battery Rack Installation, Operation, & Maintenance Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Application Engineering

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Uninterruptible Power System

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Uninterruptible Power System

NetSure. 211 Series DC Power System

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

BRAVO Inverter/Battery Charger. Table of Contents

OWNERS MANUAL JANUARY 2007 ISO

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

MIL-24/2600Q MIL-24/3200DQ

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

High Frequency SineWave Guardian TM

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

Application Engineering

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Digital/Analog Amplifiers Installation Instructions

MM-AVR UPS Series User s Manual

E-Series and EF-Series Systems

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

V1606 3U RACK ENCLOSURE

PS24/AC Volt AC 16 Amp

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

UTILITY INPUT MAINS OUTLET

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

OutdoorXUPS-600AHV-8364

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

ALLIANCE SERIES OWNER'S MANUAL

CLEAN POWER TM CPS Series Operator s Manual

LED Pinspot 2. Snapshot. User Manual

Airpax Dimensions, Inc.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

LED Pinspot 2. Snapshot. User Manual

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

TOTAL POWER MODULE (TPM) HIGH FREQUENCY FLOAT CHARGER / BATTERY ELIMINATOR WITH UNIVERSAL INPUT USED WITH A TOTAL POWER CAGE (TPC)

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

SAFETY WARNINGS AND GUIDELINES

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Snapshot. User Manual BOB LED

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Operation and Maintenance

1 AMP CURRENT SOURCE

Foreword

Power Distribution Units AP9560 & AP9561

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

WARNINGS, CAUTIONS AND NOTES

Transcription:

Installation & Operations Manual DP140e System Engineering International SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, MD 21704 Phone 301-694-9601 / 800-765-4SEI Fax 301-694-9608 Web http//www.seipower.com 19-058-000 Rev A

TABLE OF CONTENTS Table of Contents...... 1 Table of Illustrations...... 1 Description...... 2 Technical Specifications...... 3 Safety Information...... 4 Installation Instructions...... 4 Start Up and Checkout...... 6 Repair and Maintenance...... 6 Troubleshooting......... 7 TABLE OF ILLUSTRATIONS DP140e........ Figure 1.1...... 2 DP140e Models......... Appendix A....... 8,9 DP140e Distribution Configurations.. Appendix B..... 10 Wiring Configurations...... Appendix C..... 12 Connector Wiring......... Appendix D..... 13 1

DESCRIPTION 1.1 The DP140e Power Supply has been designed to service a wide range of customer premises equipment requiring 48vdc. The unit provides 250 watts of rectifier power and distribution to 24 terminals. The DP140e is capable of being mounted on a wall, 19 inch rack, 23 inch rack and 25 inch rack. The DP140e has two physical configurations, a 14 inch chassis with an internal 8 amp hour backup battery and a 7 inch chassis with no internal battery. Additional external battery packs may be added to provide up to 8 hours or more of hold over time. Additional features include a Low Voltage Disconnect, LVD, to protect the backup batteries from deep discharge, manual and automatic internal battery test, front panel status indicators for battery charge and test status and remote alarm contacts for AC failure and battery test failure. Model DP140e Figure 1.1 2

TECHNICAL SPECIFICATIONS Electrical Specifications Input Voltage 120 VAC +10%/-15% Frequency 45-66 Hz Power 320 watts max Output Voltage 42-55 Vdc Current 4.5 amps dc max LVD cut-off 42.0V Mechanical Dimensions DP140e Width Depth Height DP140e-8 Width Depth Height 19.00 in. 5.00 in. 7.00 in. 19.00 in. 5.00 in. 14.00 in. Environmental Temperature Operating Storage 0 C to +40 C -10 C to +50 C Humidity Thermal 0 to 95% non condensing 190 BTU/hr max LED Indicators Battery Charge Status: Constant Green Fully Charged Flashing Green Charging Constant Red On Battery Fast Flash Red- Adjust Supply User Interface Manual Battery Test Switch -Push to Test NOTE: The Manual Battery Test switch is disabled when the battery is charging. Also, to prevent unnecessary battery discharge, the Manual Battery Test is disabled for 5 minutes 3

Battery Test Status: Constant Green Battery Good Fast Flash Red Wait, Then Test Slow Flash Red Replace Battery following a Battery Test. In both cases, the Wait, Then Test indication is displayed. SAFETY INFORMATION Always insure that the person assigned to the job can perform the job safely. Always lift all equipment properly. Always disconnect commercial power and remove the battery fuse before working on the unit. Always replace the batteries with batteries of the same type and style. DO NOT work on this equipment during an electrical storm. DO NOT work in locations where there is condensing moisture or standing water. INSTALLATION INSTRUCTIONS GENERAL The installation section of this manual will provide all of the information required for room requirements, proper inspection, and installation; as well as instructions on checking and bringing the DP140e on line for use. Inspection The equipment has been fully tested and inspected prior to shipment. Although the unit has been packed in accordance with good commercial practices, this does not preclude damage in transit. The following actions should be taken on receipt of the equipment: Visually inspect the packaging container for damage. If damaged, request that the carrier inspect the shipment. Unpack and remove the unit from the packaging. Inspect the unit for visible damage. If a claim for damages is to be made, it should be filed promptly with the transportation company. In addition, notify SEI within two days of delivery. SEI will advise the customer 4

of any further procedures that may be required, including an RMA number in the event that the unit has to be returned to the factory for repair. Make sure the following items are included inside the package: One DP140e Power Supply Unit. One AC Power Cord. One warranty card. One Installation and Operations Manual. Mounting Instruction. Location Requirements Electrical Requirements The DP140e requires 120 VAC, 60hz commercial power for operation. If 230 VAC operation is required, please notify the factory. The DP140e should not be placed on a circuit with other equipment. A separate circuit should be run to the closet for powering the DP140e. Each unit requires a separate NEMA 5-15R receptacle. A standard 7 foot 6 inch power cord with a molded NEMA 5-15 plug is supplied with each unit. Environmental Requirements A clean dry location should be picked for installing this unit. Mounting Instructions When mounting, keep in mind the DP140e weighs 19 lbs., and the DP140e-8 weighs 32lbs. The DP140e is designed to mount to a wall, a 19 inch rack, a 23 inch rack and a 25 inch rack. For wall mounting, it is recommended to use a 3/4 inch plywood backboard. Whether the unit is to be wall or rack mounted, it should be mounted vertically. It is important that the power supply be given adequate ventilation above, below and on both sides of the unit. The DP140e comes standard for wall mount or 19 in rack mount. Optional mounts for 23 and 25 in racks are available. 5

START UP AND CHECKOUT Power On Checkout. Once the unit is properly mounted, you may begin the checkout procedure. First, insure that all the equipment to be powered by the unit is installed. Install the battery fuse, located on the right side of the unit just below the distribution panel. Attach the supplied AC power cord to the left side of the DP140e. Plug the DP140e power cord into the AC commercial power outlet made available for this purpose. The Battery Charge Status Indicator will be either solid green or flashing green and the battery test indicator should be solid green. Connect the equipment to the distribution connector for power output on the right side of the unit. You should have power indicator on the equipment you connected to the power supply. Your DP140e supply should now be functioning properly in addition to the equipment you have connected. Battery Test: When the battery is fully charged (Battery Charge Status LED constant green), press the Manual Battery Test switch. Wait five seconds then verify that the Battery Test Status LED is green. (The Manual Battery Test is only available when the Power Unit is has completed charging the battery pack). Repair and Maintenance REPAIR AND MAINTENANCE The DP140e power supply has been designed to operate unattended and with low maintenance overhead for extended periods of time. However, the rectifier output voltage should be check on an annual basis and adjusted if outside of the recommend range of 54.4 to 55.5V Tools and Test Equipment 6

No special tools other than those normally contained in an electronic technicians toolkit are required to service the DP140e. To check the system voltage and reset as necessary, it is recommended that a quality digital voltmeter be used. Adjustments The rectifier used in the DP140e may require adjustment of the output voltage. Care should be used if this adjustment is made. Connect the digital voltmeter to the external battery connector and adjust the rectifier for a voltage of 54.6 Vdc on the external battery connector. Troubleshooting TROUBLESHOOTING The attached guide is intended to provide help with any problems you may run into. Please note that this is not a complete list of problems. Question - We have just completed installation of the system and we have no front panel indicator. Answer - You will need to check the following: Check the power cord on the left side of the unit. Check the power cord at the commercial wall outlet. Check the circuit breaker in the power distribution panel. Using a voltmeter, check the AC voltage at the wall outlet. This voltage should be between 92 and 132 volts AC. Question - We have just completed installation of the system and we have a power problem. There are no indicators on the equipment connected to the power supply. Answer - There are several things which need to be checked. First, are the front panel indicators on the power supply on? If not go to 7.1.2. At the distribution module, disconnect the cable. Using a voltmeter, check the output connector. If your voltage is 54 volts or more the power supply is okay. 7

Plug the cable back into the power supply. Disconnect the cable from the load unit. Measure the voltage at the cable connector. Is it the right polarity and voltage? If you have a specific question not addressed in this manual, please call 1-800-765-4SEI and ask for technical support. 8

Constant Green : Fully Charged Flashing Green : Charging Constant Red : On Battery Fast Flash Red: Adjust Supply Battery Charge Status Battery Charge Status Push to Test Battery Constant Green : Battery Good Fast Fast Red: Wait, Then Test Slow Flash Red: Replace Battery Fast Flash Red: Adjust Supply DP140e Constant Green : Fully Charged Flashing Green : Charging Constant Red : On Battery Fast Flash Red: Adjust Supply Battery Charge Status Battery Charge Status Push to Test Battery Constant Green : Battery Good Fast Fast Red: Wait, Then Test Slow Flash Red: Replace Battery Fast Flash Red: Adjust Supply DP140e 9

10

11

Power Connections NT1 1-6 Premsis Connections Terminals 1-12 Power Connections NT1 7-12 TYPICAL WIRING USING DP SERIES Cabling A NT1B-310 Card Cage Cable AC- SEI DP Series Power U Interface from Service NT1 To 66/110 Cabling A NT1M-210 To 66/110 SEI DP Series Power U Interface from Service Central Office Connections Lines 1-12 Cabling A NT1-200 Card U Interface from Service DC SEI DP Series Power Power S/T To Phones 66/110 Power Appendix C 12

13

14