TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

Similar documents
TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES :

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES:

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY.

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

045 : 2000 CEB STANDARD

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-

43-SDMS-01 SPECIFICATIONS FOR

: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS :

66 kv SF6 CIRCUIT BREAKER (SPRING OPERATED)

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

شركة كهرباء محافظة القدس المساهمة المحدودة

Publication No.: PSG

Technical Specifications

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Technical Specification of 11KV 200Amp. (3-Pole/2-Pole) Air Break Switch Scope Description of the materials Standards Insulator make

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

026-2 : 1996 CEB STANDARD

Technical Specification

HARYANA VIDYUT PRASARAN NIGAM LTD.

TITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record

TECHNICAL SPECIFICATION

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

CP Automatic capacitor bank

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

TECHNICAL SPECIFICATIONS

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

GROUP-D. Capacitor Bank. Parameters:-

33KV INDOOR SWITCHGEAR

SECTION V, 3-PHASE, 630 AMPS MCCB & ENCLOSURE

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

TENDER NO. MGVCL / PP / D2 / 4017/Metal LTDB

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Section V DC Nickel Cadmium Alkaline BATTERY

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES

Dakshin Gujarat Vij Company Limited

TECHNICAL SPECIFICATION FOR SUPPLY OF LT DISTRIBUTION KIOSK FOR 250/315 KVA & 63/100 KVA RATING DISTRIBUTION TRANSFORMERS AGAINST TN-2077

TECHNICAL SPECIFICATION FOR 30 V, 100 AH STATIONARY BATTERIES AND BATTERY CHARGING EQUIPMENT. (SPECIFICATION NO. MSEB/Dist/IV/2004.

34-SDMS-02 SPECIFICATIONS FOR

TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Technical Specification of GECOL. Packaged Transformers

INTERPLANT STANDARD - STEEL INDUSTRY

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Outdoor vacuum breaker for railway applications - FSK II

Prüffeld der Schaltwerke

West Bengal State Electricity Distribution Co. Ltd.

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

SPECIFICATIONS FOR 220KV OUT DOOR CIRCUIT BREAKERS. The networks are mainly of outdoor type. The basic parameters are set out below:

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Transformer bushings, type GOH. Technical guide

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

7 The revised IS 8034:2002 and revised STI be implemented w.e.f. 1 Feb 2005.

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 240 Kvar

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

EMPAC Metal enclosed capacitor bank for wind applications

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

SPECIFICATIONS FOR 50 V, 600 AH LEAD ACID BATTERY

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

University of Houston Master Construction Specifications Insert Project Name

TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-AL 59 CONDUCTOR FOR 220 KV TRANSMISSION LINE

Step 1: Collection of required data

B kv Gas-insulated Substations

B kv T&D GAS INSULATED SWITCHGEAR

Independent Testing Laboratory for High Voltage Equipment

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD. ( A

Medium Voltage Metal-Enclosed Switches

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

/ I S S : / S T S I

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Technical Specification For Outdoor Substation Harmonic Filter Banks

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

RDSO/PE/SPEC/AC/ (Rev. 0 ) SPECIFICATION FOR VANE TYPE AIR FLOW RELAY FOR ROOF MOUNTED AC PACKAGE UNIT

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996

Transcription:

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE: This specification covers 11kV 50 Hz pole-mounted automatically switched capacitor installations comprising of (i) (ii) 11 kv automatic capacitor switches and 12.65kV capacitor banks of 660 KVAR rating 2.0 OPERATING / SERVICE CONDITIONS: The equipment/material offered shall be entirely satisfactory for operation under the conditions indicated below : - 2.1 SERVICE CONDITIONS: a) Maximum Ambient Temperature (Degree C) : 50 b) Minimum Ambient Temperature ( Degree C) : 3.5 c) Relative Humidity (%) : 10 to 100 d) Maximum annual rain fall (mm) : 1450 e) Maximum wind pressure ( Kg/ m Sq) : 150 f) Maximum Wind Velocity : 45 g) Isoceraunic level (days / year) : 50 h) Maximum altitude above mean sea level ( Meter ) : 1000 i) Seismic level (Horizontal acceleration) : 0.3g j) Moderately hot and humid tropical climate : conducive to rust and fungus growth 2.2. OPERATING CONDITIONS : a) Nominal system voltage : 11 kv b) Highest system voltage : 12 kv c) Normal frequency : 50 Hz 3.0 APPLICABLE STANDARDS: Unless otherwise stipulated in this specification, the capacitor switch shall comply with the latest version of IS : 9920 ( AC switches for voltage above 1000V). 4.0 CONTROL SUPPLY: The capacitor switch shall be self powered from 11 kv line i.e. no AC or DC Control supply shall be required to be provided by the utility for its operation. The source of control supply (auxiliary transformer, etc) should work satisfactorily with voltage fluctuation on the 11 kv line from +10% to -20%. 5.0 DESIGN & CONSTRUCTION REQUIREMENT: 5.1 The capacitor switches may be of either single phase or three phase construction as per the standard design of the manufacturer. Preferred Switching for single phase construction is as follows: - MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 2 OF 7

In case of single phase construction the switching of capacitor shall be Preferably near voltage zero i.e. when system voltage and capacitor voltage is zero. 5.2 The capacitor switch shall be suitable for outdoor installation and shall have sealed weatherproof type construction. 5.3 The capacitor switch shall be provided with a mechanical indicator to show the contact position in the open/ closed position. Provision shall also be made for manual closing and opening. 5.4 The metallic enclosure of the capacitor switch shall be provided with two earthing terminals (marked with the earth symbol) 5.5 The bushing provided on the switch shall be of higher quality porcelain and shall have clamp type of terminals to directly receive aluminium conductor s upto 10mm dia in both horizontal and vertical directions. The terminal arrangement shall be such as to avoid bimetallic corrosion. 5.6 The switch should be provided with suitable structures for mounting the switch and control transformers on the double pole structures. 5.7 All nuts, bolts and mounting structures should be hot dip galvanized. 6.0 CONTROL PARAMETERS : 6.1 The control parameters for switching operation shall be the line current at the point of installation of the switch. The maximum value of the line current shall be 150A and accordingly, a current transformer of 150 /5A. Ratio shall be supplied alongwith the switch to monitor the line current in one of the phases for the purpose of control. The switch shall have adjustable current at which the capacitor bank shall be switched on or switched off. This adjustment shall be available in continuous variation or in steps not exceeding 5A each over a minimum range of 10-40 Amps. [line current]. The capacitor bank shall be switched off whenever the 11kV line voltage exceed (+) 10%. The measurement of line voltage should be done by the auxiliary transformer as per clause4. 7.0 MECHANICAL & ELECTRICAL ENDURANCE: a) Mechanical Endurance Test: The switch shall be capable of performing not less than 10,000 Mechanical operations. b) Electrical Endurance Test: The switch shall be capable of performing successful 10,000 electrical operations at 50 A capacitive current. In lieu of electrical endurance test of 10,000 electrical operations, tender should give performance guarantee for sixty months from date of dispatch which ever is earlier. 8.0 MARKING: The capacitor switch shall be provided with a name plate legibly and distinctly marked with the following: MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 3 OF 7

9.0 TESTS: a) Name of the manufacturer. b) Type, design and serial number. c) Rated voltage and current. d) Rated frequency e) Number of poles. f) Rated short time current (Symmetrical) g) Rated making current. h) Rated capacitive switching current. The switch shall be subjected to the following tests in accordance with the IS 9920 (Part IV) with the latest amendments. 9.1 TYPE TESTS: a) Test to verify the insulation level, including withstand tests at power frequency voltage on auxiliary equipment. b) Tests to prove that temperature rise of any part dose not exceed the specified values. c) Making and Breaking tests. d) Tests to prove the capability of the switch to carry the rated shirt-time current. e) Tests to prove satisfactory operation and mechanical / electrical endurance. 9.2 ROUTINE TESTS: a) Power frequency voltage dry test. b) Voltage tests for auxiliary circuits. c) Measurement of the resistance of main circuits. d) Tests to prove satisfactory operation. 10.0 TYPE TESTS REPORTS: The tenderer shall furnish detailed type test reports of the offered Automatic Capacitor Switches for the tests as per relevant IS mentioned in this specification. All these type tests shall be carried out at laboratories that are accredited by the National Accreditation Board of Testing and calibration Laboratories (NABL) of government of India. These tests should have been carried out with in 5 years prior to the date of opening of this tender. However, the tenderers who have supplied the automatic Capacitor Switches to this Distribution Co. / erstwhile Board against order from Purchaser of M.S.E.D.C.L. / erstwhile M.S.E.B. shall be exempted from submission of type test reports against this tender, provided offered Automatic Capacitor Switches are already fully type tested at Laboratories accredited by the National Accreditation Board of Testing and Calibration Laboratories (NABL) within five years prior to the date of opening of the tender and there is no change in the design of already type tested the Automatic Capacitor Switches and those offered against this tender. Such tenderers shall furnish an undertaking in the scheduled F enclosed herewith. The employer reserves the right to demand repetition of some or all the Type Tests. For this purpose, the tenderer shall quote unit rates for carrying out each Type Test. MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 4 OF 7

However, such unit rates will not be considered for evaluation of the offer. In case the unit fails in the type tests, the complete supply shall be rejected. The successful tenderer shall take approval / waiver of type tests from C.E. (Dist.) / C.E. (Infra.), M.S.E.D.C.L Prakashgad, Bandra, Mumbai, prior to commencement of supply. 11.0 Bill of Material enclosed along with the tender specification incorporating structure, Lightning Arresters, are only indicative and the scope of the supply is already mentioned in this specification. 12.0 The equipment offered by the manufacturer shall comply with the general safety regulations. 13.0 BILL OF MATERIAL: 1) Capacitor Switch -1no 2) 11KV CT for Switch if not built in -1no 3) Control Transformer -1no 4) Control Box for Capacitor Switch -1no 5) Control Cables - As required. 6) Structure for control transformer -1no 7) Structure for mounting of capacitor -1no Switch on double pole structure 14.0 PHYSICAL DOCUMENTS SUBMISSION: i) Test Certificate as per Clause NO.9.0 of technical specification in accordance to IS 9920:2002 Shall be submitted for approval of employer. ii) Performance guarantee certificate for Electrical Endurance Test. iii) Drawing and catalogues Tender must accompany relevant catalogues and sectional drawing showing necessary details of the equipment offered. One copy of the dimensional drawing and internal construction drawing shall be submitted with the tender. As per the conditions of the tender these drawing shall be of A-3 (420 x 297) size only. Iv) Past Experience in schedule L. MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 5 OF 7

GUARANTEED TECHNICAL PARTICULARS 1a ) Name of the manufacturer 1b ) Country of manufacture 1c ) Country of origin of Equipment 2a ) Manufacturer s type and description 2b ) Reference standard IS9920:2002 3a ) rating and characteristics 3a ) Rated Voltage in kv (12 ) 3b ) Rated Current in Amp (200) 3c ) Rated Frequency in HZ ( 50 ) 3d) Number of poles ( 3 ) 3e ) Rated Capacitive switching current in Amp ( 50 ) 3f ) Rated short time current ( 4.5kA for 1 sec ) 3g ) Raged making current ( 9kA) 3h) Rated Insulation level Impulse withstand voltage in kv ( 75 ) 3i ) Rated Insulation level 00 One minute power frequency withstand voltage ( 28kV for 1 min. ) 3j ) Dielectric properties of material used in construction 3k ) Vacuum pressure 3l ) Operating mechanism (Solenoid or. Motor charged spring) 3m) Rated voltage of operating device ( 1 KV ( +10%, 0 20%) 3 n) Range and stages of the capacitive current for switching on and of the capacitor 3 o) Mechanical Endurance (At least 10000 mechanical operations) 3 p) Inherent delay between two switching operations in minutes (At least 5 min.) 3q ) Electrical service life of the equipment ( more than 10,000 electrical operations) 3r) Periodicity of maintenance of the equipment 4 ) Construction features 4a ) Type of switch (Vacuum or SF6 gas filled breaker ) 4b ) General arrangement of capacitor switch 4c ) Operating Box for capacitor switch 4 d) Control Transformer 4e ) Connection diagram of capacitor switch operating box MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 6 OF 7

SCHEDULE L SCHEDULE OF TENDERER S EXPERIENCE Tenderer shall furnish here a list of similar orders executed under execution by him to whom a reference may be made by employer in case he considers such a reference necessary. ---------------------------------------------------------------------------------------------------------------- Sr. Name of the Value of Period of Name & address to No. client and order supply and whom reference Description Commissioning may be made Of items Ordered. ---------------------------------------------------------------------------------------------------------------- 1 2 3 4 5 ---------------------------------------------------------------------------------------------------------------- NAME OF FIRM NAME & SIGNATURE OF THE TENDERER DESIGNATION DATE MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 7 OF 7