BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Similar documents
201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

MODEL 233P/111P/233P-1.5

INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Surface mounting, flush mounting, and DIN track mounting

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Industrial Power Supplies

Three-Phase Soft Starters

Single & Three-Phase Soft Starters

Part # Features & Applications Specifications Cross Reference

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Dimensions WxHxD [mm] Weight [kg]

Solid State Relays contactor with Integrated Fuse Type RGC1F

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter

Sola/Hevi-Duty S3K Series Mini-Tower UPS

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

Application Engineering

Model Number Structure

SOLSTART Instruction Manual

P445 Series Electronic Lube Oil Control

Sola 3000 Guide Specifications

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

RVS-AX Instruction Manual

MODEL 422 Submersible Pump Controller

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

XM1 - Motor protection relay

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures


Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

INSTALLATION INSTRUCTIONS

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

SECTION DC POWER SUPPLY/BATTERY CHARGER

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

SECTION MOTOR CONTROL

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

PATTERSON PUMP COMPANY

Power Supplies. SDN-C Compact DIN Rail Series

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

Operations Manual. Zero Speed Switch Sensor Model ZS09P

MCD 200 Series Soft Starters

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Liebert PowerSure PSI UPS

MATRIX LLC LEVEL CONTROL PANEL

3 Uninterruptible Power Systems

Application Engineering

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

A419ABG-3C Electronic Temperature Control

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Softstarters. Softstarters Power electronic brakes Type PEB

Selection Guide Motor Control Device Solutions

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

LH4 Modular Soft Start

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Solid State Relays, 3-phase

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Electronic timers CT-E range Selection and ordering details

Electromagnetic Industries LLP

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

SECTION MOTOR CONTROLLERS

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

C B. Operating up to 5000m altitude 5 year product warranty Models

Model 550 Series Vibration Switches

1.1 Caution Statements

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

» BEDIA Level monitoring sensors with approvals of the classification societys

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Installation and Operating Instructions

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

R & D SPECIALTIES ROTROL I USER'S MANUAL

Easy Multifunctional Safe

Electropneumatic Timing Relays Series 7000 Industrial

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Transcription:

INSTALLATION INSTRUCTIONS FOR SYMCOM S MOTORSAVER MODEL 460 BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! The Model 460 MotorSaver is an auto ranging voltage monitor designed to protect three-phase motors regardless of size. The MotorSaver is used on 190-480 VAC, 50 to 60 Hz motors to protect from damage caused by single phasing, low voltage, high voltage, phase reversal, and voltage unbalance. CONNECTIONS 1. Mount the MotorSaver in a convenient location in or near the motor control panel. If the location is wet or dusty, the MotorSaver should be mounted in a NEMA 4 or 12 enclosure. The MotorSaver can be mounted to a back panel using two #6 or #8 x 5/8 screws or can be snapped onto a DIN rail. 2. Connect L1, L2 and L3 on the MotorSaver s terminal strip to the LINE SIDE of the motor starter. (See Figure No. 1). 3. Connect the output relay to the circuitry to be controlled. For motor control, connect the normally open contact in series with the magnetic coil of the motor starter as shown in Figure No. 1. For alarm operation, connect the normally closed contact in series with the control circuit as shown in Figure No. 2. 222 Disk Drive, Rapid City, SD 57701 (800) 843-8848 www.symcom.com 2880 North Plaza Drive, Rapid City, SD 57702 (800) 843-8848

3-Phase Voltage CONTROL VOLTAGE 24-240 VAC FIGURE NO. 1: CONTROL WIRING DIAGRAM 3-Phase Voltage CONTROL VOLTAGE 24-240 VAC LIGHT FIGURE NO. 2: ALARM WIRING DIAGRAM 08/13/03-2-

SETTINGS 1. Line voltage adjustment: Rotate the VOLTAGE ADJ. (VAC) to the nominal three-phase line voltage feeding the motor 208 220 416 440 to be protected. 200 230 400 460 2. Restart delay adjustment: Rotate the 190 240 380 480 RESTART (SEC) adjustment to the desired position. The restart delay is the time between MotorSaver seeing MODEL 460 acceptable voltage and the MotorSaver closing its output contacts. For compressor applications, the restart delay should be set for the approximate time it takes for the head pressure to bleed off of the compressor. For other applications, the restart delay is typically set between 2 and 10 seconds. 3. Trip delay adjustment: Rotate the TRIP DELAY (SEC) adjustment to the desired setting. This adjustment does not affect the trip delay on phasing faults. Typically, the trip delay adjustment is set between 1 and 5 seconds. In areas where voltage fl uctuations are frequent, the trip delay adjustment may be set greater than 10 seconds. 4. Voltage unbalance adjustment: Rotate the UNBALANCE TRIP (NEMA%) adjustment to the desired unbalance trip level. The NEMA MG1 standard does not recommend operating a motor above 1% voltage unbalance without derating the motor. The NEMA MG1 standard also recommends against operating a motor above a 5% voltage unbalance under any circumstances. SymCom recommends consulting the motor manufacturer for specifi c tolerances. Percent Unbalance = Maximum Deviation from the Average Average x 100 Example: The measured line-to-line voltages are 203, 210, and 212. 203 + 210 + 212 Average = = 208.3 3 The maximum deviation from the average is the largest difference between the average voltage (208.3) and any one voltage reading. 208.3-203 = 5.3 210-208.3 = 1.7 212-208.3 = 3.7 The maximum deviation from the average is 5.3. 5.3 208.3 x 100 = 2.5% Unbalance -3-08/13/03

POWER-UP Turn on the 3 power to the motor. The MotorSaver s green RUN light will blink during the RESTART delay. After the RESTART delay, the MotorSaver r will energize its output contacts and the green RUN light will illuminate. If the contacts do not energize and the RUN light does not illuminate, see the TROUBLESHOOTING section. DIAGNOSTIC INDICATOR LIGHTS RUN RESTART DELAY REVERSE PHASE RED UNBALANCE / SINGLE PHASE HIGH / LOW VOLTAGE CONGRATULATIONS!! YOU HAVE JUST INSTALLED THE FINEST MOTOR PROTECTION AVAILABLE!! 08/13/03-4-

TROUBLESHOOTING SYMPTOM No lights are on. The unit seems completely dead. Red light is blinking (on initial power up). Red light is blinking (after the motor has been previously running). Red light is blinking in this pattern. Red light is on steady. Green light blinks and motor is not running. Green light is on steady, but motor does not start. LIGHT PATTERN N / A RED RED SOLUTION Measure the three line-to-line voltages. If any of the voltages are below 150 VAC, the MotorSaver does not have enough power to operate its internal electronics. This may occur on a single-phased system. If the voltages are correct, call SymCom at 1-800-843-8848 or 1-605-348-5580. Turn off the three-phase power. Swap any two leads powering the MotorSaver (L1, L2, or L3). There is a 50-50 chance of connecting L1, L2, and L3 correctly the fi rst time. Re-apply the three-phase power. The incoming lines have been reverse phased. The MotorSaver is preventing the motor from running backwards. Correct the phase sequence. The voltage is unbalanced or single-phased. Measure the incoming line voltages and calculate the % unbalance. If the voltage unbalance does not exceed the % unbalance reset value, call SymCom at 1-800-843-8848 or 1-605-348-5580. The voltage is out of tolerance. Measure the three line-to-line voltages. Calculate the average of the three voltages. If the average is 7% above or below the nominal voltage as selected by the LINE VOLTAGE ADJUST, the MotorSaver is functioning properly. If the voltage is within ±7% of the selected line voltage, call SymCom at 1-800-843-8848 or 1-605-348-5580. The MotorSaver is in restart delay. The MotorSaver is in run mode. Ensure other control devices are allowing the motor to start. Check control circuit for loose wires or malfunctioning switches. Any questions or comments call SymCom at 1-800-843-8848 or 1-605-348-5580 -5-08/13/03

SPECIFICATIONS 3 - Phase Line Voltage 190-480 VAC Frequency Low Voltage (% of setpoint) 50* - 60 Hz Trip 90% ± 1% Reset 93% ± 1% High Voltage (% of setpoint) Trip 110% ±1% Reset 107% ±1% Voltage Unbalance (NEMA) Trip Reset Trip Delay Time Low, High, and Unbalanced Voltage Single-phasing faults (>25% UB) Restart Delay Time After a fault or complete power loss Output Contact Rating - SPDT Pilot Duty General Purpose Power Consumption Weight Enclosure Terminal Torque Wire AWG Safety Marks 2-8% Adjustable Trip Setting minus 1% (5-8%) Trip Setting minus 0.5% (2-4%) 1-30 Seconds Adjustable 1 Second Fixed 1-500 Seconds Adjustable 480 VA @ 240 VAC 10 A @ 240 VAC 6 Watts (maximum) 14 oz Polycarbonate 6 Inch-Pounds Max. 12-20 AWG UL UL508 (File # E68520) CE IEC 60947-6-2 Standards Passed Electrostatic Discharge (ESD) Radio Frequency Immunity, Radiated Fast Transient Burst IEC 1000-4-2, Level 3, 6 kv contact, 8 kv air 159 MHz, 10 V/m *NOTE: 50 Hz will increase all delay timers by 20% 08/13/03-6- IEC 1000-4-4, Level 3, 3.5 kv input power and controls

Surge IEC ANSI / IEEE Hi-potential Test Environmental Temperature Range Class of Protection IEC 1000-4-5, Level 3, 4kv line-to-line; Level 4, 4kv line-to-ground C62.41 Surge and Ring Wave Compliance to a level of 6kv line-to-line Meets UL508 (2 x rated V +1000V for 1 minute) Ambient Operating: -20-70 C (-4-158 F) Ambient Storage: -40-80 C (-40-176 F) IP20, NEMA 1 (Finger Safe) Relative Humidity 10-95%, non-condensing per IEC 68-2-3 DIMENSIONS 2.350 SymCom warrants its microcontroller based products against defects in material or workmanship for a period of fi ve (5) years* from the date of manufacture. All other products manufactured by SymCom shall be warranted against defects in material and workmanship for a period of two (2) years from the date of manufacture. For complete information on warranty, liability, terms, and conditions, please refer to the SymCom Terms and Conditions of Sale document. -7-08/13/03

Visit our website at www.symcominc.com for our complete catalog and new product listings! 2880 North Plaza Drive, Rapid City, SD 57702 Phone: (800) 843-8848 or (605) 348-5580 FAX: (605) 348-5685