Standard Materials Bodies and covers: copper-free aluminum.

Similar documents
O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

Lighting and Power Distribution Panelboards

EBMC Combination Line Starters and Enclosures

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Division 1 Explosionproof Panelboards

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Enclosures. See Section Typical Description

3. Coils shall be of molded construction

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

SECTION MOTOR CONTROL

Motor Starters Hazardous and Non-Hazardous

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Industrial Control & Circuit Breakers

PowerPact B. Molded case circuit breakers and switches from A

Hazardous Factory Sealed Control Devices

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Circuit Breakers Hazardous

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Hazardous Duty Applications

Enclosures. Section E

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

NMC Combination Line Starters and Enclosures

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

A302DN.40/.63A Thermal Current Motor Starter

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

MAGNETIC MOTOR STARTERS

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

ICG Switchgear Price List 2009

NEMA Contactors & Starters (Freedom)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Enclosed Molded Case Circuit Breakers

EIC combination motor starters

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

SECTION PANELBOARDS

T&B EX TM Motor control

Protection Equipment. 5/2 Introduction

Bussmann series Quik-Spec Power Module Switch elevator disconnect

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

X1PB: Explosionproof Panelboards

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

CIRCUIT BREAKER PANELBOARDS

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Enclosed Full-Voltage Starters

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Motor Starter Protectors

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Plug and Play Kit Installation and Wiring (Non-Combo and Combo)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

SIGNAL WORDS QUALIFIED PERSON

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

Protection Equipment

Dry-Type Transformers Mini-Power Centers

Motor Starter Protectors

Enclosed Full-Voltage Starters

Overload Relay Heater Tables

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Multi-Pak Group Control

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

ACE20 explosionproof variable frequency drives Utilizes Allen-Bradley PowerFlex 700 drives

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

C E R T I F I C A T E O F C O M P L I A N C E

Plugs and Receptacles: Hazardous Location

UMBW-UL489 and UL1077 Listed

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

ESW/PESW. Non-Combination Starters

WARREN COUNTY, N.Y. M/E REFERENCE

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Contactors & Starters Index

Control Circuit Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Transcription:

-26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and Non-Combination motor starters are used in areas where hazardous materials are handled or stored. These units provide disconnecting means, under voltage protection, circuit protection, and motor running protection. Features 65,000 AIC. Highest interrupt rated enclosure in the industry. Copper-free cast aluminum. Precision machined flame path between box and cover. Bolt on slotted mounting feet. Stainless steel block hinges. Stainless steel, captive Quad-Lead cover bolts (disengaged in 1-1/2 turns). External stainless steel breaker operating handle. Breaker and operator shafts are stainless steel. Ground lug package and installation instructions for termination of ground wire enclosed. Four point control terminal block, NEMA 1B w/wire markers. Breaker operators can be locked in the n or ff position (combination starters only). Four plugged 3/4 NPSM outlets drilled and tapped for control devices. Standard outlets top and bottom. Plugged 1/2 outlets top and bottom for breather/drain. Components are mounted on a galvanized steel removable pan. Enclosures are designed to accept Cutler-Hammer, or Square D motor starters/circuit breakers. For other manufacturers, consult factory. -ring Gasket insures watertight integrity. Standard Materials Bodies and covers: copper-free aluminum. Cover bolts: stainless steel -ring: neoprene Hinges: stainless steel. Standard Finish Corrosion resistant grey powder coat epoxy inside & out. ptions See page -46. Compliances: UL Standard 50, 698, 877, 1203. CSA Certified - Standard C22.2 No 30. NEMA 4, 4X, 7BCD, 9EFG. Cutler Hammer is a trademark of the Eaton Corporation. Square D is a trademark of Groupe Schneider. PAGE 26

AEB Series: Catalog Numbering Logic -27 SAMPLE CATALG NUMBER Example: The part number below depicts an Appleton, Class I, Div. I, Groups B,C & D, NEMA Size 1, Bolted type, Combination Full Voltage Non-Reversing Motor Starter operating at 480VAC, Cutler-Hammer starter w/120vac control voltage, and a Cutler-Hammer 7A MCP. If a breaker is not required, omit last two characters. AE 1 B B 4 W 1 C 2 * Suffix for ther ptions/features (See Modifications on Page -46) Breaker Trip (MCP) 1=3A 4=30A 7=100A 0=400A 2=7A 5=50A 8=150A 3=15A 6=70A 9=250A Breaker Trip (Thermal Mag) A=15A F=40A M=90A S=200A X=400A B=20A G=50A N=100A T=225A C=25A H=60A P=125A U=250A D=30A J=70A Q=150A V=300A E=35A K=80A R=175A W=350A Breaker Manufacturer C=Cutler-Hammer S=Square D (Consult factory for other manufacturers) Control Voltage (120V coil standard) (1) 1=120V 4=480V 7=24VDC 2=240V 5=575V 8=48VDC 3=380V 6=600V Starter Manufacturer W=Cutler-Hammer (A200) S=Square D (8536) (Consult factory for other manufacturers) perating Voltage 1=120V 4=480V 7=24VDC 2=240V 5=575V 8=48VDC 3=380V 6=600V Starter Function A=FVNR (ATL) G=2S2W B=Comb. FVNR H=Comb. 2S2W C=FVR J=Contactor (3 pole) D=Comb. FVR K=Comb. Contactor (3 pole) E=2S1W M=Lighting Contactor (3-12 pole) F=Comb. 2S1W N=Comb. Lighting Contactor (3-12 pole) (Consult factory for enclosure layouts on starter functions C, D, E, F, G & H) Enclosure Type B Series NEMA Size (0, 1, 2, 3, 4 & 5) (For Size 6 consult factory) Series AE (1) 120V power must be provided from separate source, or by adding CPT option. Cutler Hammer is a trademark of the Eaton Corporation. Square D is a trademark of Groupe Schneider. PAGE 27

-28 Class I, Div. 1 and 2 AEB Series Motor Starter Enclosures: Non-Reversing Bolted Enclosure. Combination Full Voltage Non-Reversing Enclosure nly NEMA Catalog Approx. Standard Mtg. Hdw. Size Number Weight (lbs) Conduit Set Cat. No. 0 AE0BB 80 1-1/2 AMH7 1 AE1BB 80 1-1/2 AMH7 2 AE2BB 85 1-1/2 AMH7 3 AE3BB 140 2-1/2 AMH7 4 AE4BB 140 2-1/2 AMH7 5 AE5BB 500 4 AMH8 Full Voltage Non-Reversing Enclosure nly NEMA Catalog Approx. Standard Mtg. Hdw. Size Number Weight (lbs) Conduit Set Cat. No. 0 AE0BA 80 1-1/2 AMH7 1 AE1BA 80 1-1/2 AMH7 2 AE2BA 85 1-1/2 AMH7 3 AE3BA 140 2 AMH7 4 AE4BA 140 2-1/2 AMH7 5 AE5BA 500 4 AMH8 PAGE 28

Class I, Div. 1 and 2-29 AEB Series Full Voltage Motor Starters: 3 Phase, 60 Hertz, Non-Reversing (Across-the-Line), 120V Coil Cutler Hammer, Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 240 480 600 0 3 NA AE0BA2W1 80 1-1/2 AMH7 1 7-1/2 NA AE1BA2W1 80 1-1/2 AMH7 2 15 NA AE2BA2W1 85 1-1/2 AMH7 3 30 NA AE3BA2W1 140 2 AMH7 4 50 NA AE4BA2W1 140 2-1/2 AMH7 5 100 NA AE5BA2W1 500 4 AMH8 0 5 NA AE0BA4W1 80 1-1/2 AMH7 1 10 NA AE1BA4W1 80 1-1/2 AMH7 2 25 NA AE2BA4W1 85 1-1/2 AMH7 3 50 NA AE3BA4W1 140 2 AMH7 4 100 NA AE4BA4W1 140 2-1/2 AMH7 5 200 NA AE5BA4W1 500 4 AMH8 0 5 NA AE0BA6W1 125 1-1/2 AMH7 1 10 NA AE1BA6W1 125 1-1/2 AMH7 2 25 NA AE2BA6W1 130 1-1/2 AMH7 3 50 NA AE3BA6W1 195 2 AMH7 4 100 NA AE4BA6W1 195 2-1/2 AMH7 5 200 NA AE5BA6W1 500 4 AMH8 PAGE 29

-30 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breakers: 3 Phase, 60 Hertz, Non-Reversing, 120V Coil Cutler Hammer, Bolted Enclosure Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 2 15 AE0BB2W1CA 125 1-1/2 AMH7 0 3 20 AE0BB2W1CB 125 1-1/2 AMH7 1 5 40 AE1BB2W1CF 125 1-1/2 AMH7 1 7-1/2 50 AE1BB2W1CG 125 1-1/2 AMH7 2 10 50 AE2BB2W1CG 130 1-1/2 AMH7 2 15 100 AE2BB2W1CL 130 1-1/2 AMH7 240 3 20 100 AE3BB2W1CL 195 2-1/2 AMH7 3 30 125 AE3BB2W1CM 195 2-1/2 AMH7 4 40 175 AE4BB2W1CR 195 2-1/2 AMH7 4 50 200 AE4BB2W1CS 195 2-1/2 AMH7 5 60 250 AE5BB2W1CU 500 4 AMH8 5 75 300 AE5BB2W1CV 500 4 AMH8 5 100 400 AE5BB2W1CX 500 4 AMH8 0 3 15 AE0BB4W1CA 125 1-1/2 AMH7 0 5 20 AE0BB4W1CB 125 1-1/2 AMH7 1 7-1/2 30 AE1BB4W1CD 125 1-1/2 AMH7 1 10 35 AE1BB4W1CE 125 1-1/2 AMH7 2 20 50 AE2BB4W1CG 130 1-1/2 AMH7 2 25 70 AE2BB4W1CJ 130 1-1/2 AMH7 480 3 50 100 AE3BB4W1CN 195 2-1/2 AMH7 3 60 125 AE3BB4W1CP 195 2-1/2 AMH7 4 75 150 AE4BB4W1CQ 195 2-1/2 AMH7 4 100 200 AE4BB4W1CS 195 2-1/2 AMH7 5 125 250 AE5BB4W1CU 500 4 AMH8 5 150 300 AE5BB4W1CV 500 4 AMH8 5 200 400 AE5BB4W1CX 500 4 AMH8 0 5 15 AE0BB6W1CA 125 1-1/2 AMH7 1 7-1/2 20 AE1BB6W1CB 125 1-1/2 AMH7 1 10 30 AE1BB6W1CD 125 1-1/2 AMH7 2 15 40 AE2BB6W1CF 130 1-1/2 AMH7 2 25 50 AE2BB6W1CG 130 1-1/2 AMH7 600 3 30 70 AE3BB6W1CJ 195 2-1/2 AMH7 3 50 100 AE3BB6W1CN 195 2-1/2 AMH7 4 75 125 AE4BB6W1CP 195 2-1/2 AMH7 4 100 150 AE4BB6W1CQ 195 2-1/2 AMH7 5 150 250 AE5BB6W1CU 500 4 AMH8 5 200 300 AE5BB6W1CV 500 4 AMH8 PAGE 30

Class I, Div. 1 and 2-31 AEB Series Combination Full Voltage Motor Starters With MCP: 3 Phase, 60 Hertz, Non-Reversing, 120V Coil Cutler Hammer, Bolted Enclosure Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 1 7 AE0BB2W1C2 125 1-1/2 AMH7 0 3 15 AE0BB2W1C3 125 1-1/2 AMH7 1 7 30 AE1BB2W1C4 125 1-1/2 AMH7 240 2 15 50 AE2BB2W1C5 130 1-1/2 AMH7 3 30 100 AE3BB2W1C7 195 2-1/2 AMH7 4 50 150 AE4BB2W1C8 195 2-1/2 AMH7 5 100 400 AE5BB2W1C0 500 4 AMH8 0 1 3 AE0BB4W1C1 125 1-1/2 AMH7 0 3 7 AE0BB4W1C2 125 1-1/2 AMH7 0 5 15 AE0BB4W1C3 125 1-1/2 AMH7 1 7 15 AE1BB4W1C3 125 1-1/2 AMH7 1 10 30 AE1BB4W1C4 130 1-1/2 AMH7 480 2 12 30 AE2BB4W1C4 130 1-1/2 AMH7 2 25 50 AE2BB4W1C5 130 1-1/2 AMH7 3 30 50 AE3BB4W1C5 195 2-1/2 AMH7 3 50 100 AE3BB4W1C7 195 2-1/2 AMH7 4 100 150 AE4BB4W1C8 195 2-1/2 AMH7 5 200 400 AE5BB4W1C0 500 4 AMH8 600 0 1 3 AE0BB6W1C1 125 1-1/2 AMH7 0 3 7 AE0BB6W1C2 125 1-1/2 AMH7 0 5 15 AE0BB6W1C3 125 1-1/2 AMH7 1 7 15 AE1BB6W1C3 125 1-1/2 AMH7 1 10 30 AE1BB6W1C4 125 1-1/2 AMH7 2 20 30 AE2BB6W1C4 130 1-1/2 AMH7 2 25 50 AE2BB6W1C5 130 1-1/2 AMH7 3 40 50 AE3BB6W1C5 195 2-1/2 AMH7 3 50 100 AE3BB6W1C7 195 2-1/2 AMH7 4 60 100 AE4BB6W1C7 195 2-1/2 AMH7 4 100 150 AE4BB6W1C8 195 2-1/2 AMH7 5 200 400 AE5BB6W1C0 500 4 AMH8 PAGE 31

-32 Class I, Div. 1 and 2 AEB Series Full Voltage Motor Starters: 3 Phase, 60 Hertz, Reversing, 120V Coil Cutler Hammer, Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 3 NA AE0BC2W1 115 1-1/2 AMH7 1 7-1/2 NA AE1BC2W1 115 1-1/2 AMH7 240 2 15 NA AE2BC2W1 125 1-1/2 AMH7 3 30 NA AE3BC2W1 300 2 AMH8 4 50 NA AE4BC2W1 300 2-1/2 AMH8 0 5 NA AE0BC4W1 115 1-1/2 AMH7 1 10 NA AE1BC4W1 115 1-1/2 AMH7 480 2 25 NA AE2BC4W1 125 1-1/2 AMH7 3 50 NA AE3BC4W1 300 2 AMH8 4 100 NA AE4BC4W1 300 2-1/2 AMH8 0 5 NA AE0BC6W1 115 1-1/2 AMH7 1 10 NA AE1BC6W1 115 1-1/2 AMH7 600 2 25 NA AE2BC6W1 125 1-1/2 AMH7 3 50 NA AE3BC6W1 300 2 AMH8 4 100 NA AE4BC6W1 300 2-1/2 AMH8 PAGE 32

Class I, Div. 1 and 2-33 AEB Series Combination Full Voltage Motor Starters with Thermal Magnetic Circuit Breaker: 3 Phase, 60 Hertz, Reversing, 120V Coil Cutler Hammer Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 2 15 AE0BD2W1CA 120 1-1/2 AMH7 0 3 20 AE0BD2W1CB 120 1-1/2 AMH7 1 5 35 AE1BD2W1CE 120 1-1/2 AMH7 1 7-1/2 50 AE1BD2W1CG 120 1-1/2 AMH7 240 2 10 50 AE2BD2W1CG 135 1-1/2 AMH7 2 15 100 AE2BD2W1CN 135 1-1/2 AMH7 3 20 100 AE3BD2W1CN 320 2-1/2 AMH8 3 30 125 AE3BD2W1CP 320 2-1/2 AMH8 4 50 200 AE4BD2W1CS 320 2-1/2 AMH8 0 3 15 AE0BD4W1CA 120 1-1/2 AMH7 0 5 20 AE0BD4W1CB 120 1-1/2 AMH7 1 7-1/2 30 AE1BD4W1CD 120 1-1/2 AMH7 1 10 35 AE1BD4W1CE 120 1-1/2 AMH7 2 20 50 AE2BD4W1CG 135 1-1/2 AMH7 480 2 25 70 AE2BD4W1CJ 135 1-1/2 AMH7 3 50 100 AE3BD4W1CN 320 2-1/2 AMH8 3 60 125 AE3BD4W1CP 320 2-1/2 AMH8 4 75 150 AE4BD4W1CQ 320 2-1/2 AMH8 4 100 200 AE4BD4W1CS 320 2-1/2 AMH8 0 5 15 AE0BD6W1CA 120 1-1/2 AMH7 1 7-1/2 20 AE1BD6W1CB 120 1-1/2 AMH7 1 10 30 AE1BD6W1CD 120 1-1/2 AMH7 2 15 40 AE2BD6W1CF 135 1-1/2 AMH7 600 2 25 50 AE2BD6W1CG 135 1-1/2 AMH7 3 30 70 AE3BD6W1CJ 320 2-1/2 AMH8 3 50 100 AE3BD6W1CN 320 2-1/2 AMH8 4 75 125 AE4BD6W1CP 320 2-1/2 AMH8 4 100 150 AE4BD6W1CQ 320 2-1/2 AMH8 PAGE 33

-34 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With MCP: 3 Phase, 60 Hertz, Reversing, 120V Coil Cutler Hammer Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 240 480 0 1 7 AE0BD2W1C2 120 1-1/2 AMH7 0 3 15 AE0BD2W1C3 120 1-1/2 AMH7 1 7 30 AE1BD2W1C4 120 1-1/2 AMH7 2 15 50 AE2BD2W1C5 135 1-1/2 AMH7 3 30 100 AE3BD2W1C7 320 2-1/2 AMH8 4 50 150 AE4BD2W1C8 320 2-1/2 AMH8 0 1 3 AE0BD4W1C1 120 1-1/2 AMH7 0 3 7 AE0BD4W1C2 120 1-1/2 AMH7 0 5 15 AE0BD4W1C3 120 1-1/2 AMH7 1 7 15 AE1BD4W1C3 120 1-1/2 AMH7 1 10 30 AE1BD4W1C4 135 1-1/2 AMH7 2 15 30 AE2BD4W1C4 135 1-1/2 AMH7 2 25 50 AE2BD4W1C5 135 1-1/2 AMH7 3 30 50 AE3BD4W1C5 320 2-1/2 AMH8 3 50 100 AE3BD4W1C7 320 2-1/2 AMH8 4 100 150 AE4BD4W1C8 320 2-1/2 AMH8 0 1 3 AE0BD6W1C1 120 1-1/2 AMH7 0 3 7 AE0BD6W1C2 120 1-1/2 AMH7 0 5 15 AE0BD6W1C3 120 1-1/2 AMH7 1 7 15 AE1BD6W1C3 120 1-1/2 AMH7 1 10 30 AE1BD6W1C4 120 1-1/2 AMH7 600 2 20 30 AE2BD6W1C4 135 1-1/2 AMH7 2 25 50 AE2BD6W1C5 135 1-1/2 AMH7 3 40 50 AE3BD6W1C5 320 2-1/2 AMH8 3 50 100 AE3BD6W1C7 320 2-1/2 AMH8 4 60 100 AE4BD6W1C7 320 2-1/2 AMH8 4 100 150 AE4BD6W1C8 320 2-1/2 AMH8 * Consult factory for size of enclosure. PAGE 34

Class I, Div. 1 and 2-35 AEB Series Full Voltage Motor Starters: Two Speed Single Winding, 5 Pole-3 Pole, 3 Phase, 60 Hertz, 120V Coil, Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 3 NA AE0BE2W1 85 1-1/2 AMH7 1 7-1/2 NA AE1BE2W1 85 1-1/2 AMH7 240 2 15 NA AE2BE2W1 190 1-1/2 AMH7 3 30 NA AE3BE2W1 540 2 AMH8 4 50 NA AE4BE2W1 540 2-1/2 AMH8 0 5 NA AE0BE4W1 85 1-1/2 AMH7 1 10 NA AE1BE4W1 85 1-1/2 AMH7 480 2 25 NA AE2BE4W1 190 1-1/2 AMH7 3 50 NA AE3BE4W1 540 2 AMH8 4 100 NA AE4BE4W1 540 2-1/2 AMH8 0 5 NA AE0BE6W1 85 1-1/2 AMH7 1 10 NA AE1BE6W1 85 1-1/2 AMH7 600 2 25 NA AE2BE6W1 190 1-1/2 AMH7 3 50 NA AE3BE6W1 540 2 AMH8 4 100 NA AE4BE6W1 540 2-1/2 AMH8 PAGE 35

-36 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breaker: Two Speed Single Winding, 5 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 3 20 AE0BF2W1CB 130 1-1/2 AMH7 1 7-1/2 50 AE1BF2W1CG 130 1-1/2 AMH7 240 2 15 100 AE2BF2W1CN 195 1-1/2 AMH7 3 30 125 AE3BF2W1CP 545 2-1/2 AMH8 4 50 200 AE4BF2W1CS 545 2-1/2 AMH8 0 5 20 AE0BF4W1CB 130 1-1/2 AMH7 1 10 40 AE1BF4W1CF 130 1-1/2 AMH7 480 2 25 70 AE2BF4W1CJ 195 1-1/2 AMH7 3 50 100 AE3BF4W1CN 545 2-1/2 AMH8 4 100 200 AE3BF4W1CS 545 2-1/2 AMH8 0 5 20 AE0BF6W1CB 130 1-1/2 AMH7 1 10 30 AE1BF6W1CD 130 1-1/2 AMH7 600 2 25 50 AE2BF6W1CG 195 1-1/2 AMH7 3 50 100 AE3BF6W1CN 545 2-1/2 AMH8 4 100 150 AE3BF6W1CQ 545 2-1/2 AMH8 PAGE 36

Class I, Div. 1 and 2-37 AEB Series Combination Full Voltage Motor Starters With MCP: Two Speed Single Winding, 5 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 240 480 0 1 7 AE0BF2W1C2 130 1-1/2 AMH7 0 3 15 AE0BF2W1C3 130 1-1/2 AMH7 1 7-1/2 30 AE1BF2W1C4 130 1-1/2 AMH7 2 15 50 AE2BF2W1C5 195 1-1/2 AMH7 3 30 100 AE3BF2W1C7 545 2-1/2 AMH8 4 50 150 AE4BF2W1C8 545 2-1/2 AMH8 0 1 3 AE0BF4W1C1 130 1-1/2 AMH7 0 3 7 AE0BF4W1C2 130 1-1/2 AMH7 0 5 15 AE0BF4W1C3 125 1-1/2 AMH7 1 7-1/2 15 AE1BF4W1C3 125 1-1/2 AMH7 1 10 30 AE1BF4W1C4 130 1-1/2 AMH7 2 15 30 AE2BF4W1C4 195 1-1/2 AMH7 2 25 50 AE2BF4W1C5 195 1-1/2 AMH7 3 30 50 AE3BF4W1C5 545 2-1/2 AMH8 3 50 100 AE3BF4W1C7 545 2-1/2 AMH8 4 100 150 AE4BF4W1C8 545 2 1/2 AMH8 0 1 3 AE0BF6W1C1 130 1-1/2 AMH7 0 3 7 AE0BF6W1C2 130 1-1/2 AMH7 0 5 15 AE0BF6W1C3 130 1-1/2 AMH7 1 7-1/2 15 AE1BF6W1C3 130 1-1/2 AMH7 1 10 30 AE1BF6W1C4 130 1-1/2 AMH7 600 2 20 30 AE2BF6W1C4 195 1-1/2 AMH7 2 25 50 AE2BF6W1C5 195 1-1/2 AMH7 3 40 50 AE3BF6W1C5 545 2-1/2 AMH8 3 50 100 AE3BF6W1C7 545 2-1/2 AMH8 4 60 100 AE4BF6W1C7 545 2-1/2 AMH8 4 100 150 AE4BF6W1C8 545 2-1/2 AMH8 PAGE 37

-38 Class I, Div. 1 and 2 AEB Series Full Voltage Motor Starters: Two Speed Two Winding, 3 Pole-3 Pole, 3 Phase, 60 Hertz, 120V Coil, Cutler Hammer. Line NEMA Max Catalog Approx. Standard Mtg Hdw. Voltage Size HP Number Weight (lbs) Conduit Set Cat. No. 0 3 AE0BG2W1 85 1-1/2 AMH7 1 7-1/2 AE1BG2W1 85 1-1/2 AMH7 240 2 15 AE2BG2W1 190 1-1/2 AMH7 3 30 AE3BG2W1 540 2 AMH8 4 50 AE4BG2W1 540 2-1/2 AMH8 0 5 AE0BG4W1 85 1-1/2 AMH7 1 10 AE1BG4W1 85 1-1/2 AMH7 480 2 25 AE2BG4W1 190 1-1/2 AMH7 3 50 AE3BG4W1 540 2 AMH8 4 100 AE4BG4W1 540 2-1/2 AMH8 0 5 AE0BG6W1 85 1-1/2 AMH7 1 10 AE1BG6W1 85 1-1/2 AMH7 600 2 25 AE2BG6W1 190 1-1/2 AMH7 3 50 AE3BG6W1 540 2 AMH8 4 100 AE4BG6W1 540 2-1/2 AMH8 PAGE 38

Class I, Div. 1 and 2-39 AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breakers: Two Speed Two Winding, 3 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 3 20 AE0BH2W1CB 130 1-1/2 AMH7 1 7-1/2 50 AE1BH2W1CG 130 1-1/2 AMH7 240 2 15 100 AE2BH2W1CN 195 1-1/2 AMH7 3 30 125 AE3BH2W1CP 545 2-1/2 AMH8 4 50 200 AE4BH2W1CS 545 2-1/2 AMH8 0 5 20 AE0BH4W1CB 130 1-1/2 AMH7 1 10 40 AE1BH4W1CF 130 1-1/2 AMH7 480 2 25 70 AE2BH4W1CJ 195 1-1/2 AMH7 3 50 100 AE3BH4W1CN 545 2-1/2 AMH8 4 100 200 AE3BH4W1CS 545 2-1/2 AMH8 0 5 20 AE0BH6W1CB 130 1-1/2 AMH7 1 10 30 AE1BH6W1CD 130 1-1/2 AMH7 600 2 25 50 AE2BH6W1CG 195 1-1/2 AMH7 3 50 100 AE3BH6W1CN 545 2-1/2 AMH8 4 100 150 AE3BH6W1CQ 545 2-1/2 AMH8 PAGE 39

-40 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With MCP: Two Speed Two Winding, 3 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 240 480 0 1 7 AE0BH2W1C2 130 1-1/2 AMH7 0 3 15 AE0BH2W1C3 130 1-1/2 AMH7 1 7-1/2 30 AE1BH2W1C4 130 1-1/2 AMH7 2 15 50 AE2BH2W1C5 195 1-1/2 AMH7 3 30 100 AE3BH2W1C7 545 2-1/2 AMH8 4 50 150 AE4BH2W1C8 545 2-1/2 AMH8 0 1 3 AE0BH4W1C1 130 1-1/2 AMH7 0 3 7 AE0BH4W1C2 130 1-1/2 AMH7 0 5 15 AE0BH4W1C3 125 1-1/2 AMH7 1 7-1/2 15 AE1BH4W1C3 125 1-1/2 AMH7 1 10 30 AE1BH4W1C4 130 1-1/2 AMH7 2 15 30 AE2BH4W1C4 195 1-1/2 AMH7 2 25 50 AE2BH4W1C5 195 1-1/2 AMH7 3 30 50 AE3BH4W1C5 545 2-1/2 AMH8 3 50 100 AE3BH4W1C7 545 2-1/2 AMH8 4 100 150 AE4BH4W1C8 545 2-1/2 AMH8 0 1 3 AE0BH6W1C1 130 1-1/2 AMH7 0 3 7 AE0BH6W1C2 130 1-1/2 AMH7 0 5 15 AE0BH6W1C3 130 1-1/2 AMH7 1 7-1/2 15 AE1BH6W1C3 130 1-1/2 AMH7 1 10 30 AE1BH6W1C4 130 1-1/2 AMH7 600 2 20 30 AE2BH6W1C4 195 1-1/2 AMH7 2 25 50 AE2BH6W1C5 195 1-1/2 AMH7 3 40 50 AE3BH6W1C5 545 2-1/2 AMH8 3 50 100 AE3BH6W1C7 545 2-1/2 AMH8 4 60 100 AE4BH6W1C7 545 2-1/2 AMH8 4 100 150 AE4BH6W1C8 545 2-1/2 AMH8 PAGE 40

Class I, Div. 1 and 2-41 AEB Series Combination Lighting Contactor With Thermal Magnetic Breaker: 3 Pole, 60 Hertz 120V Coil Cutler Hammer Line Enclosure Contactor Breaker Catalog Approx. Standard Mtg Hdw. Voltage Size Amps Amps Number Weight (lbs) Conduit (In.) Set Cat. No. 1 30 40 AE1BN1W1CF 125 1-1/2 AMH7 2 60 70 AE2BN1W1CJ 130 1-1/2 AMH7 120 3 100 125 AE3BN1W1CP 195 2-1/2 AMH7 4 200 225 AE4BN1W1CT 195 2-1/2 AMH7 5 400 450 AE5BN1W1CZ 560 4 AMH8 1 30 40 AE1BN2W1CF 125 1-1/2 AMH7 2 60 70 AE2BN2W1CJ 130 1-1/2 AMH7 240 3 100 125 AE3BN2W1CP 195 2-1/2 AMH7 4 200 225 AE4BN2W1CT 195 2-1/2 AMH7 5 400 450 AE5BN2W1CZ 560 4 AMH8 1 30 40 AE1BN4W1CF 125 1-1/2 AMH7 2 60 70 AE2BN4W1CJ 130 1-1/2 AMH7 480 3 100 125 AE3BN4W1CP 195 2-1/2 AMH7 4 200 225 AE4BN4W1CT 195 2-1/2 AMH7 5 400 450 AE5BN4W1CZ 560 4 AMH8 1 30 40 AE1BN6W1CF 125 1-1/2 AMH7 2 60 70 AE2BN6W1CJ 130 1-1/2 AMH7 600 3 100 125 AE3BN6W1CP 195 2-1/2 AMH7 4 200 225 AE4BN6W1CT 195 2-1/2 AMH7 5 400 450 AE5BN6W1CZ 560 4 AMH8 PAGE 41

-42 Class I, Div. 1 and 2 AEB Series Lighting Contactor: 3 Pole, 60 Hertz 120V Coil Cutler Hammer Line Enclosure Contactor Catalog Approx. Standard Mtg Hdw. Voltage Size Amps Number Weight (lbs) Conduit (In.) Set Cat. No. 1 30 AE1BM1W1 125 1-1/2 AMH7 2 60 AE2BM1W1 130 1-1/2 AMH7 120 3 100 AE3BM1W1 195 2 AMH7 4 200 AE4BM1W1 195 2-1/2 AMH7 5 400 AE5BM1W1 560 4 AMH8 1 30 AE1BM2W1 125 1-1/2 AMH7 2 60 AE2BM2W1 130 1-1/2 AMH7 240 3 100 AE3BM2W1 195 2 AMH7 4 200 AE4BM2W1 195 2-1/2 AMH7 5 400 AE5BM2W1 560 4 AMH8 1 30 AE1BM4W1 125 1-1/2 AMH7 2 60 AE2BM4W1 130 1-1/2 AMH7 480 3 100 AE3BM4W1 195 2 AMH7 4 200 AE4BM4W1 195 2-1/2 AMH7 5 400 AE5BM4W1 560 4 AMH8 1 30 AE1BM6W1 125 1-1/2 AMH7 2 60 AE2BM6W1 130 1-1/2 AMH7 600 3 100 AE3BM6W1 195 2 AMH7 4 200 AE4BM6W1 195 2-1/2 AMH7 5 400 AE5BM6W1 560 4 AMH8 PAGE 42

BASEPLATE -43 AEB Series Dimensions: Combination Full Voltage Motor Starter Enclosures BASEPLATE Enclosure Layout for Size 0, 1 & 2 TP VIEW BASEPLATE TP VIEW Cover bolt size: Mounting bolt size: 1/2-13 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 3 & 4 LEFT SIDE VIEW TP VIEW 1/2" NPT FR BREATHER DRAIN TP VIEW LEF LEFT SIDE VIEW BTTM VIEW TESER Cover bolt size: Mounting bolt size: 1/2-13 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 5 T TESER 1/2" NPT FR BREATHER DRAIN TP VIEW LEFT SIDE VIEW BTTM VIEW TESER 1/2" NPT FR BREATHER DRAIN TP VIEW Cover bolt size: Mounting bolt size: BTTM VIEW 5/8-11 5/8-11 PAGE 43 Note: Dimensions (in inches) are nominal.

-44 AEB Series Dimensions: Full Voltage Motor Starter Enclosures Enclosure Layout for Size 0, 1 & 2 Cover bolt size: 1/2-13 Mounting bolt size: 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 3 Cover bolt size: 1/2-13 Mounting bolt size: 1/2-13 Note: Dimensions (in inches) are nominal. PAGE 44

AEB Series Dimensions: Full Voltage Motor Starter Enclosures -45 Enclosure Layout for Size 4 Cover bolt size: 1/2-13 Mounting bolt size: 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 5 Cover bolt size: 5/8-11 Mounting bolt size: 5/8-11 Note: Dimensions (in inches) are nominal. PAGE 45

-46 Threaded and AEB Series Motor Starters: Modifications perators (1) Suffix Cat. No Factory Field Description Installed Installed Start/Stop Dual Pushbutton S3X AEPDGRE Stop Pushbutton S2X AEPRC Start Pushbutton S1X AEPGA Stop, Lighted PB, Red 120V LP5X AEPTRE Start, Lighted PB, Green 120V LP4X AEPTGE 3 Position Selector Switch A3X AESS31MN Specify Legend 2 Position Selector Switch A2X AESS22ML Specify Legend Red Pilot Light, 120V L5 AEPL1R Green Pilot Light, 120V L4 AEPL1G Red Pilot Light, 240V L52 AEPL2R Green Pilot Light, 240V L42 AEPL2G Red Pilot Light, 480V L54 AEPL4R Green Pilot Light, 480V L44 AEPL4G (1) Add L to part no. for Size 5 starters. NEMA 4X Breather/Drain Fittings Suffix Cat. No Factory Field Description Installed Installed Drain Fitting DN DRNB4X Breather Fitting BR BRTB4X (Drilled & tapped installation included.) Control Power ptions (2) (3) Suffix Cat. No Factory Field Description Installed Installed Fused CPT, 50va T1 AFCPT050 Fused CPT, 100va T2 AFCPT100 Fused CPT, 200va T3 AFCPT200 Fused CPT, 250va T4 AFCPT250 Fused CPT, 50va T5 AFCPT050R w/interposing Relay Fused CPT, 150va T6 AFCPT150 Fused CPT, 300va T7 AFCPT300 Fused CPT, 500va T8 AFCPT500 Fused CPT, 750va T9 AFCPT750 NTE: CPT includes primary and secondary fuses Additional ptions Description Suffix Cat. No Factory Field Installed Installed Engraved Nameplate, NP N/A Black letters on White surface, 2 x 4, 1/8 Letters, 3 Lines Max. Specify Legend verload Heater Provide FLA at the time of order. 40W Enclosure 120V -120V AFA4327X11 Space Heaters 240V -240V AFA4327X12 480V -480V AFA4327X13 Control Term. Blocks 8 point 8K N/A 20A, 600V 12 point 12K N/A NEMA 1B w/wire markers (Above 12 points consult factory) Auxiliary Contacts Cutler-Hammer Starter Aux. Contacts Suffix Cat. No Factory Field Description Installed Installed Size 0-4* 1N/1NC X11C AJ-11 2N/2NC X22C AJ-11 (2 ea.) Size 5** 1N/1NC X511C A3463D94G18 2N/2NC X522C A3463D94G18 (2ea.) Square D Starter Aux. Contacts Description Suffix Cat. No Factory Field Installed Installed Size 0-5 1N/1NC X11S A999SX8 2N/2NC X22S A999SX8 (2 ea.) * 8 Aux. Contacts Max. includes one seal-in and seven added. ** 4 Aux. Contacts Max. includes one seal-in and three added. Size 0-1 includes one seal-in and four added. Size 2-5 includes one seal-in and three added. Interrupt Ratings 14k AIC standard. Consult factory for higher interrupt capacities. Separate Control Fused Circuit S-120V N/A Specify Starter Coil Voltage S-240V N/A S-480V N/A (2) Size 1 & 2 150VA Max. Size 3 & 4 300VA Max. (3) Consult factory for other voltages. Cutler-Hammer is a trademark of the Eaton Corporation. Square D is a trademark of Groupe Schneider. PAGE 46

AEB Series Typical Wiring Diagram for Motor Starter Enclosures -47 Typical Wiring Diagram for Size 0-4 Typical Wiring Diagram for Size 5 PAGE 47