liquid rotor starters for slipring motors 550 to 20,000 kw EPM

Similar documents
A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

LIQUID STARTER FOR. FOR BALL & SAG MILLS from 1 000kW to kW

RVS-AX Instruction Manual

Series E4F E5F

Starting of Induction Motors

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

Permanent-magnet synchronous motors

Demag KB conical-rotor brake motors. Drives with unique principle

Modifiable TITAN Horizontal Motors Accessories and Modifications

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

Electric machine, permanent magnet internal

SINGLE PHASE TEFC CAGE MOTORS

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Secondary Resistance Controllers (SRC) for Wound Rotor Induction Motors

3 - Protection components Motor circuit-breakers

SOLSTART Instruction Manual

champion series motors

Faster project implementation. Earlier return on invest. SIMOTICS HV M shaft height 450 to 800: the modular motor concept up to 19 MW

Electric machine, permanent magnet internal

GENERAL SPECIFICATIONS

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

Comfort. Description. Applications

SIMOTICS Frei verwendbar / Siemens AG Alle Rechte vorbehalten.

Liquid ring vacuum pumps with magnetic coupling

High-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

Variable speed application guidelines

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Design specifications

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

MAGNETIC MOTOR STARTERS

Dewatering pumps for raw water pumping. / / grundfos DW RANGE

Product catalogue. Power Resistors. variable and fixed resistors wirewound resistor elements steel grid resistors. Power resistors

ADS7 AC Contactor Starters

VT Oil-Free Range Operators Handbook

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Essential equipment for all your requirements

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

OPERATION MANUAL MYCO SELF INDEXING UNIT. Clearstream Filters Inc. 57 Arnold Sayeau Dr. Delhi, ON, N4B 2W9 Tel Fax

Principles of iers (intelligent

IP66 GSW GEAR BOX MOTOR SERIES

Inverter control of low speed Linear Induction Motors

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

INTER PLANT STANDARD STEEL INDUSTRY

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

Design Standard. Purpose: Design Standard:

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

GENERAL. Typical applications are: SPECIFICATIONS. Nominal voltage (line to line) Nominal efficiency 96 % Pole pair number 6

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

GÝROL FLUID DRIVES GÝROL FLUID DRIVES SAVE ENERGY HOW GÝROL FLUID DRIVES WORK

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA

Series Motor Protection

INDEX NEMA PREMIUM EFFICIENCY

Energy-efficient Cast Iron Three Phase Induction Motors 50 Hz

Induction Motor Control

825-P Modular Protection System for motors Specification Guide

Energy Saving Three Phase Motors

The Reference in Silent Thrusters. Voith Rim-Drive Technology

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Integral Horsepower DC Motor & Generator Application Data CA608D

Pure sine wave charger inverter Product Manual

AC Synchronous Reluctance motors

Non-Standard Motors Overview. Low-Voltage. IEC Squirrel-Cage Motors Frame sizes 315 to 450 Power range 160 kw to 1250 kw

+7 /342/ Двигатели с фазным ротором (серии AML, AMK; 4-12 полюсов, до 8000 кв, HP) Телефон (многоканальный):

Intelligent Drivesystems, Worldwide Services MODULAR INDUSTRIAL GEAR UNITS

Dimensions WxHxD [mm] Weight [kg]

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

NEW NORDIC UNCONDITIONAL RELIABILITY AND PERFORMANCE LIFE BETTER MAKE

Permanent magnet brakes. Safety from the market leader. PM Line High Torque Line

Lower Operating Costs Higher Availability.

Crompton Greaves Limited

Product information. ECOSS Electronic compact starter for wound rotor drives

Standardmotoren Standard motors

voith.com The reference in silent thrusters Voith Rim-Drive technology in yachts

Oily Water Separators. globally focused on cleaner solutions

Lowara. 8 Submersible Electric Pumps. 6Z855, 6Z875 6Z895, 6Z8125 Series. 60 Hz

Open Chassis Star-Delta Starter User Guide

Asynchronous generators

Power Electronics. Motor brake relay GA 9031 ministop

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

PAC TRAINING PUMP MOTORS

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

POWER Wave XR Clean Sophisticated Reliable

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

GENERAL. Typical applications are: SPECIFICATIONS. Nominal voltage (line to line) Nominal efficiency 96% Pole pair number 6

6 Project Planning for Components on the Input Side

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

SSR Resistor. SSR Resistor. Resistor Rack. K Resistor HUBBELL. Table of Contents. Hubbell Industrial Controls, Inc.

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

300 kw ~ 6,300 kw (400 HP ~ 8,500 HP) MEDIUM VOLTAGE VERTICAL MOTORS

Transcription:

liquid rotor starters for slipring motors 550 to 20,000 kw PM The PM starter is specifically designed for controlled starting and speed control of large slipring motors in arduous applications such as Ventilation Crushing Milling Conveyors Pumps... In a variety of industries such as mines, quarries, cement plants, water treatment and associated industries. They can also be used for applications such as car fragmentisers, plastic mixers and sugar cane knives. Smooth progressive acceleration Wide range of applications Rugged and reliable Customised for each application Reduced maintenance operating principle The PM rotor starter is normally used to control the starting of a slipring motor, and the starting current is generally limited to a maximum of 250% LC. Optimal starting torque for each application is normally selected by the choice of the initial value of resistance. The principle of the PM starter is that the resistance automatically varies during the starting period. This type of starter is designed to provide the optimum starting characteristic, which results in smooth progressive acceleration to full load speed. It can also be used for speed variation and torque control. Plug braking can also be implemented with this system. The variation in the resistance is achieved by displacement of the electrodes in the electrolyte. t the end of the acceleration, the electrodes are shorted out. 1

description PM starter n PM unit comprises : the electrolytic resistance contained within a tank complete with electrodes of a size rated for the specific kw rating. the MV enclosure housing the Shorting contactor. an LV enclosure which contains the control system. Tank... The tank is manufactured with heavy duty sheet steel 30/10 to 50/10 mm gauge, and is normally supplied complete with lifting eye bolts and dimensions are determined by the motor rating. (See characteristics). The tank is filled through a filling flap and emptied through valves situated at the base of the unit, which are normally locked in the closed position. Protection: IP54. gitator... The agitator is thermostatically controlled to ensure maximum thermal capacity. lectrolyte... Various concentrations of sodium carbonate are normally employed. lectrolyte level is monitored by a float switch and the temperature is controlled by thermostats. lectrode assemblies... set consists of three fixed and moving electrodes; polypropylene containers shroud the fixed electrodes to provide adequate isolation between phases. The cast alloy electrodes consist of concentric cylinders which merge with each other in the minimum resistance position. The fixed electrodes, located inside the insulating containers, are fed from an insulated copper bar. Since this bar does not pass through the tank wall, there is no danger of electrolyte leakage. The moving electrodes travel vertically inside the insulating container, guided by a nylon rod. The assembly is supported by two brass rods fixed to a transversal carrier which is common to all three electrodes and constitutes the neutral point. Current density is extremely low (typically 1 amp/cm2 ) resulting in extremely long electrode life. lectrode control system... Displacement of the electrodes is effected by a motor driven worm screw assembly. This is normally controlled by either a geared motor or a servomotor depending on the application. n inverter may also be used for certain applications. hand wheel is also provided for emergency operation. Starting times are adjustable from 10 to 150 seconds. Control and interlocking Limit switches are incorporated to control the geared motor, and to energise the Shorting contactor which shorts out the residual resistance at the end of the run up time. The geared motor is fitted with an overload relay, which is used to provide protection in case of the drive mechanism jamming. n electrical interlock prevents a restart before the electrodes return to the initial maximum resistance position. If a power failure occurs during starting, the electrodes return automatically to the start position when the supply is restored, so that a new start is possible. Control panels... The control gear is housed in two separate enclosures. The shorting contactor complete with the rotor terminations are housed in the MV enclosure. separate housing is provided for the LV controls. The MV enclosure is normally included with the starter, but for higher ratings, it may be supplied in a separate control panel. PM DUO starter or starting machines of large powers, or to reduce mechanical stress, it may sometimes be preferable to use two motors totalling the rated power rather than a single one. dual PM starter is then used, to ensure identical acceleration of both motors. The PM DUO comprises two resistances whose ohmic values are equalised between the two tanks. The electrode drive assemblies are mechanically coupled, so as to ensure complete synchronisation of the movement of the two electrode assemblies, which are driven by a common geared motor. The two resistances are finally shorted out by a single four or six pole shorting contactor, at the end of the runup period. Heat exchanger starter The starter is normally equipped with a heat exchanger for these applications. This can either be of the water cooled type, (adequate supplies of cooling water must be available on site), or an air blast cooler can be used. 2

specifications range of models are used for the control of various motor ratings for single and dual PM drives. The adjoining table provides a guide to rating the various models of PM starters. Many factors, such as the run up time, starts per hour, starting torque, operating temperature and a range of other factors effect the selection of the starter. PM starters equipped with heat exchangers may be used with motors whose powers exceed those shown on the table. These are determined by the size of the heat exchanger. Maximum rotor voltage between sliprings: 3 500 V. Standard starting times : 20, 30, 40, 60, 80 and 130 seconds. These are preset during manufacture. The electrolyte level is monitored by a magnetic float switch. The temperature of the electrolyte is controlled by thermostats. The electrolyte is cooled by natural con S t a rter type PM1 PM 2 PM 3/1 PM 3/2 PM 4/1 PM 4/2 PM 1 DUO PM 2 DUO PM 3/1 DUO PM 3/2 DUO PM 4/1 DUO PM 4/2 DUO (1) Maximum rating for 1 start/hour or three consecutive starts from cold. TS: starting torque LT: full load torque. Max motor rating (1) T S / LT = 0.7 T S / LT = 1 T S / LT = 1.4 T S / LT = 2 1 kw 2 kw 5 200 kw 6 400 kw 7 kw 13 000 kw 2 X 1 kw 2 X 2 kw 2 X 5 200 kw 2 X 6 400 kw 2 X 7 kw vection and forced circulation. ecause the current density is low (in the order of 1 /cm2 ), the electrode life is extremely long. 1 100 kw 1 kw 3 700 kw 4 500 kw 5 500 kw 9 100 kw 2 X 1 100 kw 2 X 1 kw 2 X 3 700 kw 2 X 4 500 kw 2 X 5 500 kw 2 X 9 100 kw 790 kw 1 300 kw 2 kw 3 200 kw 3 900 kw 6 500 kw 2 X 790 kw 2 X 1 300 kw 2 X 2 kw 2 X 3 200 kw 2 X 3 900 kw 2 X 6 500 kw 550 kw 900 kw 1 850 kw 2 250 kw 2 750 kw 4 550 kw 2 X 550 kw 2 X 900 kw 2 X 1 850 kw 2 X 2 250 kw 2 X 2 750 kw 2 X 4 550 kw Maintenance... Check electrolyte level and top up with drinking water once a year. The electrode worm screw should also be greased at this time options ntifreeze heater... This comprises an immersion heater with thermostat and control gear. Inverter... The electrode drive motor can have a variation in acceleration between 10 and 150 seconds. dimensions weight PM 1 to 4 Model C G PM 1 PM 2 PM 3 PM 4 1 700 2 120 2 510 2 950 1 230 1 360 1 660 1 860 856 950 1 190 1 410 1 620 2 060 2 440 2 850 720 850 1 230 1 550 3 000 5 000 3

PM 1 and 2 DUO PM 3 and 4 DUO M o d e l C G PM 1 DUO PM 2 DUO PM 3 DUO PM 4 DUO 2 760 2 945 3 580 4 020 1 520 2 030 2 560 2 950 990 1 015 2 140 2 325 2 460 2 850 1 2 450 2 X 2 X 2 3 000 X 2 45 000 X 2 4

PM 1 to 4 with exchanger M o d e l C max. D PM 1 PM 2 PM 3 PM 4 2 410 2 840 3 270 1 640 1 735 2 025 2 245 856 950 1 190 1 410 1 920 2 350 2 770 3 180 870 1 480 1 3 000 5 000 ordering instructions The following information is necessary so that we may provide an PM starter customised to your application. General operating conditions... ambient temperature maximum and minimum temperatures relative humidity height above sea level location or the motor(s)... power speed (rpm) stator voltage rotor voltage rotor current starting torque or the driven machine... type coupling method speed (rpm) moment of inertia number of consecutive starts setting up and installation requirements or the starter control gear... protection IP 54 or 55 supply voltage for geared motor etc. control voltage or starter with heat exchanger... temperature of cooling water percentage slip for permanent slip speed variation and duty cycle Options... speed control for electrode drive special paint cable entries antifreeze control anticondensation heaters OIP maintenance The PM starter is robust and easy to operate and is designed to provide a long and trouble free life, even in the most arduous of environments. OIP provides a complete dossier for each project, which includes complete data for identifying the electrolyte, the geared motor, the control gear, the shorting contactor and all other ancillary equipment which will allow you to easily identify a component. OIP will respond quickly to meet your requirements In practice, each starter is fitted with a rating plate which is unique to each PM starter. It is only necessary to provide us with the serial number for your PM starter and OIP can quickly respond to all your queries. ll our documentation is archived for 40 years and our technicians are always available to provide worldwide assistance. Specifications above are subject to modifications without prior notice..p. 182 91006 VRY Cedex Tel. 33 1 69 36 50 60 ax 33 1 60 77 82 97 mail: export@aoip.com 5 I0