Underground Storage Tank. City of Burbank UST Owners & Operators

Similar documents
Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

Overview of an Underground Storage Tank Inspection

Compliance Strategies and Benefits

Underground Storage Tank Certification Examinations. Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

401 KAR 42:020. UST systems: design, construction, installation, and registration.

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Massachusetts Department of Environmental Protection Underground Storage Tank Program

(Please type or use black ink)

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

New UST Regulations. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most.

Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

2018 CUPA Conference. February 7, Presented by a panel of CUPA and CalEPA representatives

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

RHODE ISLAND New England Storage Tanks Conference Westborough, MA. Joe Cunningham Jillian Thompson

Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015

Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

Underground Oil Storage Tanks Annual Inspection Report

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

Mark S. Morgan, Regulatory Counsel

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

South Tacoma Groundwater Protection District Spill Prevention and Response Plan

EPA UST Regulations Update May 22, 2018

NCDEQ Underground Storage Tank Section

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY STATISTICAL INVENTORY RECONCILIATION (SIR) GUIDANCE DOCUMENT

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

Testing Requirements for UST s and AST s. By Mark Lindsey June 27 th, 2013

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

BUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION

NYSDEC CBS Compliance Requirements

New Tank Installations. Peter Rollo

Preventing Leaks and Spills at Service Stations. A Guide for Facilities

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST

UST Compliance Assistance Handbook

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

SPCC Marina Inspection Update Oklahoma Marina Association Inspector Tom McKay

State Water Resources Control Board

UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS

UNDERGROUND STORAGE TANK (UST) INSTALLATION & MAINTENANCE

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF UST S AN OVERVIEW OF UNDERGROUND STORAGE TANK REQUIREMENTS

1) Activity Description: Management of Petroleum Storage Tanks and Containers

To facilitate the extension of departmental services through third party testing organizations as provided for by CRS (b)

ES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number

Sunoco, Inc Market Street LL Philadelphia, PA June 29, 2006

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems

NYS DEPARTMENT OF ENVIRONMENTAL CONSERVATION CLASS C OPERATOR TRAINING

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.

UST Compliance Review

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION

Monthly Walkthrough Inspections

UST General Requirements Inspection Checklist

NYSDEC PBS REGULATIONS Heating Oil Tanks

Environmental Regulations and Codes For Underground Tank Storage of Flammable & Combustible Liquids

Syracuse University Petroleum Bulk Storage Tank Program Manual

ANNUAL UST SYSTEM INSPECTION CHECKLIST

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

Test Date: 3/30/2018 Order Number: Dear Regulator, Enclosed are the results of recent testing performed at the following facility:

TITLE 165. CORPORATION COMMISSION CHAPTER 25. UNDERGROUND STORAGE TANKS RM PROPOSED RULES NOVEMBER 30, 2015

New UST Installation Inspection Checklist

TITLE 165. CORPORATION COMMISSION CHAPTER 25. UNDERGROUND STORAGE TANKS EFFECTIVE September 11, 2017

Petroleum Storage Tank Release Detection and Inventory Control

These regulations are created pursuant to and of the Colorado Revised Statutes.

Management of Underground Storage Tanks

P.O. Box 435 Saratoga Springs, NY 12866

Pennsylvania DEP: Maintaining UST Compliance and Regulation Updates. NISTM 8 th Annual Pennsylvania Storage Tank Conference May 18, 2017

New Regs Get Ready for Containment Testing if You Haven t Done So Already!

PURPOSE RESPONSIBILITY

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

Date. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4

Questions And Answers About The 2015 Underground Storage Tank Regulation As Of May 2017

Petroleum Storage Program

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

ORDINANCE NO

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

ELD ELECTRONIC LOGGING DEVICES SUMMARY OF REGULATORY MANDATE RULE. Rev 1/27/17

Notification for Underground Storage Tanks

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

Business and Noninstructional Operations

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

CITY OF SACRAMENTO CALIFORNIA. May 28, 2002

John Benson David Hanny Barton & Loguidice, P.C.

Regulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities

Semiannual Report Of UST Performance Measures End Of Fiscal Year 2018 (October 1, 2017 September 30, 2018)

HS23PG_Commercial Motor Vehicle Program

IGNITION INTERLOCK SERVICE CENTER RENEWAL LICENSE

Cannabis Cultivation Update. Richard Parrott, Director CalCannabis Cultivation Licensing Division California Department of Food and Agriculture

2018 UST Regulation Revision Comment Worksheet

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY. Policy Subject: Number Page OVERNIGHT RETENTION OF COUNTY VEHICLES D-10 1 of 5

Transcription:

Underground Storage Tank City of Burbank UST Owners & Operators Created by: Kern County Environmental Health CUPA, Edited by: Burbank Fire Department for the Burbank Fire Department s use

Burbank Fire Department Phone: (818) 238-3473 Email: BurbankCERS@burbankca.gov

Table of Contents Definitions of Levels of Responsibilities Owner/Operator Responsibilities Designated Operator Responsibilities Designated Operator Binder Facility Information Form Tank Information Form Monitoring Procedure Plan Emergency Response Plan Certificate of Financial Responsibility Hazardous Materials Business Plan Training UST Monitoring Site Plan Owner/Operator Agreement Required Testing and their frequencies Daily Logs Record Retention - CERS - Minor, Class II, Class I Violations; Red Tag - Enforcement Process - Questions & Answers

Mandate In 1999, the Legislature Required SWRCB to Adopt Regulations Requiring Training For: Owners and Operators Service Technicians Installers and Inspectors...meet minimum industry-established training standards Health and Safety Code, Chapter 6.7,Section 25284.1(a)(4)(A)(i)

Levels of Responsibilities Defined UST Owner or Operator Holds the UST operating permit, and is legally responsible for the UST system Designated UST Operator Has knowledge of UST laws, regulations, and management practices, and has obtained ICC certification Facility Employee Works with the UST system on a routine basis, and is trained by UST Designated Operator

Responsibilities of an Owner / Operator All UST Owners & Operators must: Be registered with the appropriate regulatory authority (CERS), and meet leak detection requirements. In addition owners and operators must: Meet Financial Responsibility requirements Perform a site check and corrective action in response to leaks, spills and overfills Follow regulatory rules during installation of new tanks and closure of existing tanks Maintain records as required Have periodic checks performed on corrosion protection and leak detection systems put forth by the state and local authorities that implement the UST program

Responsibilities of an Owner / Operator Statement of Compliance California Code of Regulations, Title 23, Section 2715(a) Owner understands, and is in compliance with, all applicable UST requirements Designated UST Operator name and contact information are to be uploaded into CERS whenever there is a change of Owner or Designated Operator

Regulatory Definition: Designated UST Operator Designated UST Operator: One or more individuals designated by the owner to have responsibility for training facility employees and conducting monthly visual inspections at an UST facility. A Designated UST Operator is not considered the Operator, although the same individual may hold both positions. California Code of Regulations, Title 23, Section 2611

Requirements of a D.O. Effective January 1, 2005 Possess a current California UST System Operator certification issued by the International Code Council (ICC) Certification must be renewed every 2 years Perform monthly visual inspections for each facility and maintain a log Provide on-the-job training for facility employee(s) and re-train every 12 months New employees must receive training within 30 days of hire

Monthly Visual Inspection Review alarm history for previous month, and check that each alarm was responded to appropriately Inspect spill containers and under dispenser containment for water, debris, and hazardous substances (fuel) Check that monitoring equipment in under dispenser containment is located in the upright position at the lowest point to detect a leak Check sumps if in alarm

Monthly Visual Inspection Inspection of tank-top sumps is required ONLY when there has been an alarm in that sump within the last month, and there is no record of a service visit If sump inspection is required, check for: water, debris, hazardous substance (fuel) in the sump monitoring equipment in the upright position at the lowest point

Monthly Visual Inspection Check that all required testing and maintenance for the UST has been completed Examples include annual monitoring system certification, tightness testing, secondary containment testing (SB 989), ELD, cathodic protection testing, monthly ATG test required for single walled tanks to detect a 0.2 gph leak rate, single wall tank interior lining, line leak detector test, etc. Verify that facility employees have been trained as required

Recording the Monthly Inspection Inspection results must be recorded, and a copy given to the UST Owner The UST owner must maintain monthly inspection records for at least 12 months The Designated Operator must notify the Owner/Operator of any conditions that require follow-up action It is the OWNER/OPERATOR s responsibility to make any repairs, clean-ups, or schedule testings.

Binder Recommendations Maintain all records onsite

CERS California Environmental Reporting System A statewide, web-based system www.cers.calepa.ca.gov Supports businesses and Unified Program Agencies with electronically reporting, collecting, and managing hazardous materials-related data Mandated by the California Health and Safety Code and AB 2286

CERS CERS Reporting Requirements HMIS Must be verified and resubmitted annually

CERS Forms Located at Burbank Fire Department Website Monitoring Plan (Instructions) (Form) Monitoring Site Map Certificate of Financial Responsibility (Instructions) (Form) UST Response Plan Owner Statement of Designated UST Operator Letter from Chief Financial Officer (Instructions) (Form) UST Owner Operator Agreement (Instructions) (Form)

Training to Include Emergency Procedures as indicated in Emergency Response Plan Employee s responsibilities regarding spill/overfill response and notification Emergency shut-off locations and procedures Employee s responsibilities regarding monitoring equipment and alarm response according to best management practices

UST Monitoring Site Plan Must include and depict: USTs Piping Line leak detectors Sensors (annular space, sumps, UDCs, etc.) Tank level monitors Monitors Dispensers Spill containers Emergency shut-off

Good UST Site Plan

Bad UST Site Plan

Testing Frequencies Annual Monitoring Certification Annually Secondary containment testing (SB989) 6 months after initial installation and every 3 yrs afterwards. Line test single wall vs. double wall Tank Integrity test Single wall tank lining integrity test 10 years and then every 5 years Cathodic protection system testing 3 years + 60 day logs Enhanced Leak Detection

Alarm/repair log If alarm recorded on Daily inspection log, it must be recorded on here as well Inventory warnings are not required to be recorded Be sure to note the response to alarm or repair

Record Retention Monitor Certifications & SB989 tests 3 years Monthly D.O. reports 12 months Cathodic protection tests 6 ½ years Modifications and/or repairs Life Training Documentation 1-2 years

Violation Classification Minor Class II Class I

Minor Violations Health and Safety Code, Section 25404 Examples of Minor Violations: Failure to update or submit complete tank and facility forms No maintenance and monitoring records on site Training records not onsite

Class II Violations Health and Safety Code, Section 25117.6 Examples of Class II Violations: Failure to document a recordable release Mechanical monitoring device within the UST system is not operational A device to remove liquid from the spill bucket is not available/functional Timely repairs were not made following a failed secondary containment test Owner/Operator did not designate an ICC certified Designated Operator Owner/Operator does not have monthly inspection records

Class I Violations Health and Safety Code, Section 25117.6 Examples of Class I Violations: Tampering with monitoring equipment Failure to repair non-functional monitoring equipment Failure to report an unauthorized release. Failure to repair secondary containment Failure to complete/pass secondary containment testing Failure to properly close a UST Failure to complete Annual Monitoring Certification

Red Tag Authority CCR Title 23, Division 3, Chapter 16, Underground Tank Regulations Article 10.5 Upon the discovery of a significant violation that poses an imminent threat to human health, safety, or the environment, immediately affix a red tag to the fill pipe to provide notice that the delivery of petroleum into the UST system is prohibited

What s wrong with these?

??? Sensor in wrong location and not picking up leak

??? Liquid in sump

??? Sensor is mounted wrong and wrong position

??? Penetrations are possible leak locations

??? Raised sensor, should be lowered

??? Sensor in wrong location and not properly mounted

ENFORCEMENT PROCESS Violations noted during Routine Inspection Notice of Violation (NOV) and letter to correct Referral to City Attorney