Ground Connectors All Copper Alloy Specification Grade

Similar documents
Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

Conduit Bushings for Rigid Metal Conduit and IMC

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Rigid Metal Conduit, IMC or EMT K-Clamps

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

General Cable Support Information

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

TYPE BLT DISCONNECT SWITCHES

CONTENTS ComboGear Updated 5/17/2016

SURFACE TRACK (120/250V) SPECIFICATIONS

Instruction Sheet for Powertite Plug, Connector and Receptacle

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

TA Ta VA CTRL-XFRMR

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb.

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

Henderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

SECTION PIPE HANGERS AND SUPPORTS

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

INTEGRID TRACK (120V) SPECIFICATIONS

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Use the following standards for system design and performance requirements.

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

MICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708

HANGERS, STRUT, AND FITTINGS SUBMITTAL

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

W-Series Junction Boxes

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

SAE FLANGES V C. Specialists in VESCOR. Hydraulic Reservoirs and Accessories

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Multi-Pak Group Control

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Junction Boxes Hazardous and Non-Hazardous

Force Control Switches

INSTALLATION MANUAL.

Product Comparisons. Door Closers. stanleysecurity.com

Ford Brass Saddles Style 101B and 202B

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Enclosed Cable System with Portable Lowering Tool for Drop Ceiling Mount * Manual System for Indoor and Outdoor Use.

Model Stroke, Two Handle Push Pull Control Head

KLIK LEDpod 40 Patented


AFL FLOODLIGHT SERIES

HARDWARE DURHAM BOLTS. EST. SHIPPING WEIGHT(lbs) UNIT CTN CTN CTN CTN CTN

The applicable material specifications for ductile iron and rubber gaskets apply:

Applications. Standard Materials

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

EPOXY POWDER COATED COPPER FREE ALUMINUM

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

KLIK LEDpod 50 Patented

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

NOT FOR CONSTRUCTION ACCESS DOOR IS SECURED USING 1/4-20 TORX T27 SECURITY SCREWS.13 [3] STEEL ACCESS DOOR ACCESS DOOR - SEE DETAIL B

The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM

Copper Bar... ASTM B187, B152 Silicon Bronze... ASTM F468, F467, F651

PDI PowerWave 2 Bus System

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

MAR031615A 1. PABD Installation & Maintenance. Guide *Parts will differ for high pressure valves.

KLIK LEDpod 40 Patented

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Spring-loaded cover seats against neoprene gasket.

Condulet Cast Device Boxes and Covers Application and Selection

Suggested Specifications

MOUNTING SYSTEMS SPECIFICATIONS

BRACKETS, MOUNTS & HARDWARE

Transcription:

Connectors For cable connection parallel or at right angles to pipe or rod. Features A high strength corrosion-resistant copper alloy ground connector connecting a ground wire either parallel or at right angles to a ground rod or pipe. A positive ground is assured by the clamping pressure that can be applied by the high strength silicon bronze U-bolt, nuts and lock washers. Type ABG connectors are suitable for direct burial. For ground pipe larger than 11 2 use Type CG Connector. UL Listed: E-24264 Nema: FB-1 Type ABG at Right Angles Conduit Type ABG Parallel Conduit Rod Size Driven (In.) AG/kcmil Pipe Size Min. Max. L U B 5/8 or3/4 3/8 8 4 33.3 (1.31) 54.1 (2.13) ABG-0304 5/8 or3/4 3/8 4 2/0 38.1 (1.50) 60.5 (2.38) ABG-0322 5/8 or3/4 3/8 2/0 250 47.8 (1.88) 66.8 (2.63) ABG-0325 1 1/2 or3/4 2/0 250 57.2 (2.25) 47.8 (1.88) 76.2 (3.00) ABG-0725-1 8 4 65.0 (2.56) 33.3 (1.31) 69.9 (2.75) ABG-1104-1 2/0 250 65.0 (2.56) 47.8 (1.88) 85.9 (3.38) ABG-1125-1-1/2 2/0 250 79.5 (3.13) 47.8 (1.88) 95.3 (3.75) ABG-1525 368

Connectors For cable connection either parallel or at right angle to pipe. A high strength corrosion-resistant copper alloy ground connector having a reversible contact plate which permits the ground wire to be connected either at right angles or parallel to a ground pipe. The fitting is designed so that the saddle can be installed before the ground connection is made. High strength silicon bronze hardware permits high clamping pressures to be applied. For ground pipe smaller than 2 use Type ABG. Type CG connectors are suitable for direct burial and wet locations. UL Listed: E-24264 CSA Certified: 057250 Fed. Spec: -F-406E AG/kcmil Type CG Pipe L Type CG Pipe Size (Inches) Min. Max. L U B 2 8 4 92.20 (3.63) 22.35 (0.88) 95.25 (3.75) 9.65 CG-2004 2 4 2/0 92.20 (3.63) 30.23 (1.19) 101.60 (4.00) 9.65 CG-2022 2 2/0 250 92.20 (3.63) 36.58 (1.44) 104.90 (4.13) 9.65 CG-2025 2 300 500 98.55 (3.88) 47.75 (1.88) 114.30 (4.50) 11.18 (0.44) CG-2050 2-1/2 8 4 104.90 (4.13) 22.35 (0.88) 107.95 (4.25) 9.65 CG-2604 2-1/2 4 2/0 104.90 (4.13) 30.23 (1.19) 114.30 (4.50) 9.65 CG-2622 2-1/2 2/0 250 104.90 (4.13) 36.58 (1.44) 120.65 (4.75) 9.65 CG-2625 2-1/2 300 500 111.25 (4.38) 47.75 (1.88) 127.00 (5.00) 11.18 (0.44) CG-2650 3 8 4 120.65 (4.75) 22.35 (0.88) 122.17 (4.81) 9.65 CG-3104 3 4 2/0 120.65 (4.75) 30.23 (1.19) 130.30 (5.13) 9.65 CG-3122 3 2/0 250 120.65 (4.75) 36.58 (1.44) 136.65 (5.38) 9.65 CG-3125 3 300 500 133.35 (5.25) 47.75 (1.88) 146.05 (5.75) 12.70 (0.50) CG-3150 3 550 750 CG-3175 3-1/2 8 4 133.35 (5.25) 22.35 (0.88) 133.35 (5.25) 9.65 CG-3604 3-1/2 4 2/0 133.35 (5.25) 30.23 (1.19) 143.00 (5.63) 9.65 CG-3622 3-1/2 2/0 250 133.35 (5.25) 36.58 (1.44) 149.35 (5.88) 9.65 CG-3625 3-1/2 300 500 146.05 (5.75) 47.75 (1.88) 155.70 (6.13) 12.70 (0.50) CG-3650 3-1/2 550 750 CG-3675 4 8 4 146.05 (5.75) 22.35 (0.88) 146.05 (5.75) 9.65 CG-4104 4 4 2/0 146.05 (5.75) 30.23 (1.19) 155.70 (6.13) 9.65 CG-4122 4 2/0 250 146.05 (5.75) 36.58 (1.44) 155.70 (6.13) 9.65 CG-4125 4 300 500 158.75 (6.25) 47.75 (1.88) 168.40 (6.63) 12.70 (0.50) CG-4150 4 550 750 CG-4175 5 4 2/0 174.75 (6.88) 30.23 (1.19) 181.10 (7.13) 9.65 CG-5122 5 2/0 250 174.75 (6.88) 36.58 (1.44) 187.45 (7.38) 9.65 CG-5125 5 300 500 184.15 (7.25) 47.75 (1.88) 196.85 (7.75) 12.70 (0.50) CG-5150 5 550 750 CG-5175 6 4 2/0 203.20 (8.00) 30.23 (1.19) 209.55 (8.25) 9.65 CG-6122 6 2/0 250 203.20 (8.00) 36.58 (1.44) 215.90 (8.50) 9.65 CG-6125 6 300 500 212.85 (8.38) 47.75 (1.88) 225.55 (8.88) 12.70 (0.50) CG-6150 6 550 750 212.85 (8.38) 60.45 (2.38) 238.25 (9.38) 12.70 (0.50) CG-6175 6 800 1000 212.85 (8.38) 60.45 (2.38) 238.25 (9.38) 12.70 (0.50) CG-6192 8 2/0 250 254.00 (10.00) 36.58 (1.44) 266.70 (10.50) 9.65 CG-8125 8 300 500 263.65 (10.38) 47.75 (1.88) 276.35 (10.88) 12.70 (0.50) CG-8150 8 550 750 CG-8175 8 800 1000 CG-8192 Top View B U COMMERCIAL AND INDUSTRIAL FITTINGS: GROUNDING FITTINGS/SOLDERLESS CONNECTORS 369

Connectors CEC: This ground connector is used for grounding H column fence posts. Its design eliminates the need for drilling the post. To attach, loosen the nut sufficiently to allow the end of the J bolt to slip over the flange, assemble the cable into the fitting and then tighten. Standard Materials Current carrying parts - cast copper alloy Standard Finishes J bolt, nut and washer - hot hip galvanized steel CEC Certifications and Compliances Type TG I-Beam Min. Solid "H" Column Fence Post Max. Str. Min. Max. L B 4 4/0 1.31 1.95 104.9 (4.13) 25.4 (1.00) 9.65 TG-24 370

Connectors Rated for Ordinary Locations An economical ground connector for connecting a ground wire to any flat surface. Copper alloy body and silicon bronze bolt, nut and lock washer combine strength and corrosion-resistance to insure a positive ground connection. HEX-CUP construction of the fitting simplifies installation by requiring only a single wrench for tightening. Type KGM One-Piece Design COMMERCIAL AND INDUSTRIAL FITTINGS: GROUNDING FITTINGS/SOLDERLESS CONNECTORS AG/kcmil Min. Max.. L H B 8 4 4 2/0 2/0 250 300 500 550 750 800 1000 41.4 (1.63) 60.5 (2.38) 85.9 (3.38) 31.8 (1.25) 38.1 (1.50) 41.4 (1.63) 46.0 (1.81) 58.7 (2.31) 66.8 (2.63) 11.2 (0.44) 12.7 (0.50) KGM-04 KGM-22 KGM-25 KGM-50 KGM-75 KGM-92 371

Connectors For connecting two parallel cables of the same or varying sizes to any flat surface. Installation of connectors is simplified by HEX-CUP construction. s are gripped by the interlocking clamp, used throughout the line of ground devices. Copper alloy body and silicon bronze bolts, nuts and lock washers make a completely corrosion resistant fitting and permit high pressure to be applied - insuring a positive ground connection. Suitable for direct burial NOTE: Bolts furnished will fasten connector to plate 1/4 thick. Longer bolts will be furnished when necessary if plate thickness is specified. Contact your local representative. Type LG One Bolt H L B C AG/kcmil L Min. Max. L H B 8 4 4 2/0 2/0 250 300 500 550 750 800 1000 54.1 (2.13) 88.9 (3.50) 98.6 (3.88) 31.8 (1.25) 38.1 (1.50) 57.2 (2.25) 52.3 (2.06) 65.0 (2.56) 79.5 (3.13) 11.2 (0.44) 12.7 (0.50) B LG-04 LG-22 LG-25 LG-50 LG-75 LG-92 372