THERMOSCREENS AIR CURTAINS

Similar documents

MINIVEIL AIR CURTAINS

I.C.E. DIRECT FIRED MAKE-UP AIR UNITS

OIL BURNER NOZZLES

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir

IDENTIFICATION ACCESSORIES DESCRIPTION

Features: Available in horizontal and vertical units

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

COMFORT AIR CURTAIN. SensAir

ECCODUCT. In-Slab Duct Ventilation System ECCO is proud to be a member of: REV. W-4

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

NAILOR COMMERCIAL REGISTERS, GRILLES AND DIFFUSERS

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Multi directional heating. Air heaters Model NOZ

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

AIR CURTAINS AIR CHAMBER DESIGN

Catalog Air curtain NAC

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

AIR CURTAIN DESIGNER C RANGE Horizontal and Vertical

Ceiling swirl diffusers

VENTILATION PRODUCTS. For The Dairy Industry. (519)

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

Automatic Entrance Specialists

Ventilation grilles for installation into walls, sills or rectangular

ROL NOZZLE DUCT ROL-S ADJUSTMENT AND SILENCER UNIT

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

CornerAir. CornerAir. Active chilled beam

PVC Strip Door Curtains & Swing Doors

series Linear grilles

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

ACR RECESSED AIRCURTAIN ELECTRICALLY HEATED, AMBIENT & LPHW INSTALLATION AND OPERATING MANUAL

Ceiling swirl diffusers with perforated face plate

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Application Guidelines

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Ceiling swirl diffusers

Tourniket. The all round revolving door. Door Systems

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Air curtain.

Stannah Midilift SL/GL

1.1 VTS: Manufacturer No. 1 in the world constituents of success

ZOO FAN SDF Destratification Ceiling Mounted Fan

low profile duct system

Slot diffusers, Round duct diffusers. IMP Klima

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Square Mixed Flow Fans (MFQ)

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

MANUAL RECESSED AIR CURTAINS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

FANTECH

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

MOBILAIR M 13/M 15/M 17. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 0.75 to 1.60 m³/min (27 57 cfm) COMPRESSORS

DRUM JET DIFFUSERS. Available in Aluminium & Stainless Steel

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

Workshop Compressors PREMIUM Series.

INDUSTRIAL rolling doors and grilles

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Essentials encapsulated kw

CAL / CEL / CDL / CGL / CKL

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

AIR CURTAIN HX RECESSED RANGE

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

NEW Acoustic In-Line Fans (ACQ)

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

BERNER AIR CURTAINS. The Energy Saving DOORWAY SOLUTION for Comfort & Safety. MADE in USA For Over 60 Years

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Technical Information

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Compact Design BB101 & 93

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

SERIES H. Heavy Duty Adjustable Deflection Grilles

Axial fans. What s more, non-stock models are normally available within two weeks.

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

PREMIUM INVERTER DUCTED AIR CONDITIONING

SERIES H. Heavy Duty Adjustable Deflection Grilles

Short casing. Long casing (L version) Commercial premises

SILENT MV Ultra Quiet In-line Fans

The new 10.8 V Li-Ion machines: Power-Head- Technology.

A Smarter Breed. of Centrifugal Fans

Medium Pressure Centrifugal Fans

Sentry. Door Curtain. Energy efficient EC motors Cased and concealed models LPHW and electric heating Comprehensive range of controls

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Delta Secure Spiroll 40 High Speed Security Door. Product Data Sheet 4 / 7

Ventilation grilles for installation into walls, sills or rectangular

Rosemex Products 2009 HEATING UNIT HEATERS FOR STEAM OR HOT WATER

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

Vent-Axia Sabre Sickle Roof Fans (VSR)

LINEAR SLOT DIFFUSERS

INDUSTRIES INDUVENT. With the patented Teddington EVOLVENT Nozzle Technology.

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

Transcription:

INDEX c-range recessed... 12-4 surface mounted... 12-4 introduction... 12-2 Jet range... 12-6 -range recessed... 12-5 surface mounted... 12-5 selection guide... 12-3 technical data... 12-7 12-11 This section contains product and technical information only. For additional information and product pricing please contact your local ECCO Supply Sales Branch. ECCO is proud to be a member of: ASHAE American Society of Heating, efrigerating, and Air-Conditioning Engineers, Inc. www.ashrae.org HAI Heating, efrigeration and Air Conditioning Institute of Canada www.hrai.ca HADI Heating, Airconditioning & efrigeration Distributors International www.hardinet.org SMACNA Sheet Metal and Air Conditioning Contractors National Association www.smacna.org SPIDA Spiral Duct Manufacturers Association www.spida.org ECCO Supply www.eccosupply.ca 12-1

Effective: September 2010 introduction Pioneers of air curtains in North America, Thermoscreens are a market-leading manufacturer of high quality air curtain solutions with an established and well-respected reputation worldwide. Thermoscreens produce a comprehensive range of heated, ambient and cold store air curtains, both surface and recess mounted, for many applications including retail, commercial, public sector buildings, architectural, industrial, and refrigerated environments. Thermoscreens products are backed by their proven brand reputation, offering outstanding design, service, quality and reliability. This is evidenced by accreditation to the Quality Management Systems BS EN ISO9001:2008. Thermoscreens believe in sustainability and to this end adhere strictly to the Environmental Management Systems BS EN ISO14001:2004. Established Brand Advanced Engineering and Design Excellent Service Excellent Quality Outstanding eliability Availability Competitive Solutions WHY FIT AN AI CUTAIN? Comfort: Air curtains help promote the perfect environment, whether warm, cool or ambient. Open Door Policy: Air curtains promote open door trading in retail outlets and provide uninterrupted access for passing trade. Energy Saving: Air curtains over open doors promote significant energy savings. Protection: Air curtains help to ensure a clean and healthy environment. Health and Safety: In refrigeration applications, Thermoscreens cold store air curtains can significantly reduce the ingress of warm air when doors are required to be left open for access, helping to retain the refrigerated air inside. Ease of Installation: Air curtains are not only easy to install but also easy to maintain throughout their serviceable life. A simple and cost effective solution for a comfortable environment. Typically, warm air escapes and cold air enters. With an air curtain, warm air is retained and cold air entering is heated. The Perfect Environment All Prices F.O.B. Our Warehouse Subject to Change Without Notice All Taxes Extra 12-2 www.eccosupply.ca

selection guide To ensure maximum effectiveness and comfort, it is important to choose the correct air curtain. An air curtain with too little velocity will not be able to stop cold drafts from entering the building, while an air curtain that is too powerful and has been installed at the incorrect door height could be noisy and Surface Mounted uncomfortable. To select the appropriate air curtain, the following factors should be taken into account: Type of building and the interior design of the premises Type of air curtain required ecessed Surface mounted or recessed al, Water, or Ambient Voltage and power supply Installation height If an air curtain is to operate to maximum effectiveness, it is essential that the air curtain has sufficient air velocity to discharge over the whole height and width of the doorway. The width of the door opening The air curtain should be wider than the width of the door. Overlapping the full opening, the air curtain controls the ingress of air and Installation Height other pollutants, maintaining a comfortable environment. Characteristics of buildings (i.e. doorway locations, through drafts). Ensure the units are positioned as close to the door opening as possible and that there are no obstructions between the air curtain jet of air and the opening of the door. Selection Overview Models C ange ange recommended height Up to 3m surface mounted Up to 2.75m recessed Up to 4m surface mounted Up to 3.75m recessed heating mounting options electric water ambient surface recessed Jet ange Up to 2.3m Width of Door Opening suggested applications Entrance Small to medium sized buildings with a moderate pedestrian flow. estaurants, retail, and commercial buildings. Entrance Medium to large sized buildings with a high pedestrian flow. Applicable for industrial doors, airports, shopping centres, factories and warehouses Ideal for small openings, i.e. kiosks and drive-through windows note: This information should be used as a guideline only. If you require more technical information or would like to verify that the unit you have selected suits the application, please contact your local ECCO Supply Sales Branch. www.eccosupply.ca 12-3

c-range surface mounted All electrically heated units have a selection of two fan speeds and two heat control stages. Ambient and water units have a selection of three fan speeds. Colour: All models are finished in an off-white colour (AL 9010). Finish: AL 9010 casings are manufactured from pre-finished sheet steel. For other AL colours casing is manufactured from powder coated sheet steel. Installation: All units come with a set of standard mounting brackets, which simplifies installation. Certain situations might require special hardware or preparation to mount the brackets on to. Delivery and service: All models are stocked and serviced locally. The Compact design makes this unit ideal for commercial buildings, department stores and restaurants. 3.0 0 C1000 C1500 C2000 0.8-1.0 1.0-1.5 1.5-2.0 Door Width (m) Note: For Technical Data see end of section. c-range recessed All electrically heated units have a selection of two fan speeds and two heat control stages. Ambient and water units have a selection of three fan speeds. Grille supplied as standard AL 9010 Installation: All units come with a set of standard mounting brackets, which simplifies installation. Certain situations might require special hardware or preparation to mount the brackets on to. The Compact design makes this unit ideal for commercial buildings, department stores and restaurants. 2.75 0 C1000 C1500 C2000 0.8-1.0 1.0-1.5 1.5-2.0 Door Width (m) Note: For Technical Data see end of section. 12-4 www.eccosupply.ca

-range surface mounted All electrically heated units have a selection of two fan speeds and two heat control stages. Ambient and water units have a selection of three fan speeds. Colour: All models are finished in an off-white colour (AL 9010). Finish: AL 9010 casings are manufactured from pre-finished sheet steel. For other AL colours casing is manufactured from powder coated sheet steel. Installation: All units come with a set of standard mounting brackets, which simplifies installation. Certain situations might require special hardware or preparation to mount the brackets on to. Perfect for airports, commercial buildings, civic buildings, department stores, factories and warehouses, food processing plants, high street shops with large openings, shopping malls. 4.0 0 1000 1500 2000 0.8-1.0 1.0-1.5 1.5-2.0 Door Width (m) Note: For Technical Data see end of section. -range recessed All electrically heated units have a selection of two fan speeds and two heat control stages. Ambient and water units have a selection of three fan speeds. Finish: Grilles are supplied as standard anodised aluminium. Grilles can be sprayed to any AL/BS colour. Installation: All units come with a set of standard mounting brackets, which simplifies installation. Certain situations might require special hardware or preparation to mount the brackets on to. Very powerful unit. Perfect for airports, commercial buildings, civic buildings, department stores, factories and warehouses, food processing plants, high street shops with large openings, shopping malls. 3.75 0 1000 1500 2000 0.8-1.0 1.0-1.5 1.5-2.0 Door Width (m) Note: For Technical Data see end of section. www.eccosupply.ca 12-5

Jet range Suitable for drive-thru windows Available in two sizes Available colour Al 9010 (off white) Curved styling Bracket mounting enables angular adjustment of heat flow low noise levels Three settings: fan only, half heat and full heat Built in ergonomically designed integral control switches Note: For Technical Data see end of section. 12-6 www.eccosupply.ca

technical data c-range surface mounted C ange Surface Mounted 600 volt Models dimensions Supply # Heat loading Max. Max. Air Weight **db(a) Metric (l x d x W) Motors Output per (A) velocity volume (kg)/ @3m Imperial (mm)/(in) @HP (kw)/(btu/hr) current (m/s)/ (m 3 /h)/ (lbs) draw (ft/min) (ft 3 /min) C1000E NT 1137 x 275 x 198 600v~3P&N, 60Hz 1@1/8 4.5/9 *9.3 9.0 1250 22 55 45 x 11 x 8 15,370/30,735 1770 740 48 C1500E NT 1669 x 275 x 198 600v~3P&N, 60Hz 1@1/8 6/12 *12.8 9.0 1800 30 55 66 x 11 x 8 20,490/40,980 1770 1060 66 C2000E NT 2200 x 275 x 198 600v~3P&N, 60Hz 2@1/8 9/18 *18.6 9.0 2500 41 56 87 x 11 x 8 30,735/61,470 1770 1470 91 C ange Surface Mounted 120-208 volt Ambient C1000A NT 1137 x 275 x 198 120v~1P&N, 60Hz 1@1/8 1.2 9.0 1250 15 55 45 x 11 x 8 1770 740 35 C1500A NT 1669 x 275 x 198 120v~1P&N, 60Hz 1@1/8 1.9 9.0 1800 21 55 66 x 11 x 8 1770 1060 46 C2000A NT 2200 x 275 x 198 120v~1P&N, 60Hz 2@1/8 2.4 9.0 2500 31 56 87 x 11 x 8 1770 1470 68 C1000E NT 1137 x 275 x 198 208v~3P&N, 60Hz 1@1/8 4.5/9 *27.0 9.0 1250 18 55 45 x 11 x 8 15,370/30,735 1770 740 39 C1500E NT 1669 x 275 x 198 208v~3P&N, 60Hz 1@1/8 6/12 *36.0 9.0 1800 26 55 66 x 11 x 8 20,490/40,980 1770 1060 57 C2000E NT 2200 x 275 x 198 208v~3P&N, 60Hz 2@1/8 9/18 *54.0 9.0 2500 37 56 87 x 11 x 8 30,735/61,470 1770 1470 82 lphw C1000W NT 1137 x 275 x 198 120v~1PN&E,60Hz 1@1/8 6 1.2 8.5 1180 16 55 45 x 11 x 8 20,490 1670 700 35 C1500W NT 1669 x 275 x 198 120v~1PN&E,60Hz 1@1/8 9 1.9 8.5 1700 23 55 66 x 11 x 8 30,735 1670 1000 51 C2000W NT 2200 x 275 x 198 120v~1PN&E,60Hz 2@1/8 12 2.4 8.5 2360 33 56 87 x 11 x 8 40,980 1670 1400 73 ** Sound pressure levels (dba) at 3m, as given in the brochure, are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several db higher if the mounting height is reduced, if the room is more live (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. Noise levels will also increase if more than one air curtain is installed at the same doorway (e.g. + 3dBA for 2 equal point sources: direct field). www.eccosupply.ca 12-7

technical data (cont d) c-range recessed C ange ecessed 600 volt Models dimensions grille Size Supply # Heat loading Max. Max. Air Weight **db(a) Metric (l x d x W) inc. Flange Motors Output per (A) velocity volume (kg)/ @3m Imperial (mm)/(in) (mm)/(in) @HP (kw)/(btu/hr) Current (m/s)/ (m 3 /h)/ (lbs) draw (ft/min) (ft 3 /min) C1000E 1200 x 347 x 205 1209 x 353 600v~3P&N 1@1/8 4.5/9 9.3 9.0 1190 20 55 47 x 13 x 8 47.6 x 13.9 15,370/30,735 1770 700 44 C1500E 1600 x 347 x 205 1609 x 353 600v~3P&N 1@1/8 6/12 12.8 9.0 1730 27 55 63 x 14 x 8 63.4 x 13.9 20,490/40,980 1770 1020 60 C2000E 2100 x 347 x 205 2120 x 353 600v~3P&N 2@1/8 9/18 18.6 9.0 2380 37 56 83 x 14 x 8 83.5 x 13.9 30,735/61,470 1770 1400 82 C ange ecessed 120-208 volt Ambient C1000A 1200 x 347 x 205 1209 x 353 120v~1PN&E, 60Hz 1@1/8 1.2 9.0 1250 19 55 47 x 13 x 8 47.6 x 13.9 1770 740 42 C1500A 1600 x 347 x 205 1609 x 353 120v~1PN&E, 60Hz 1@1/8 1.9 9.0 1800 25 55 63 x 14 x 8 63.4 x 13.9 1770 1060 55 C2000A 2100 x 347 x 205 2120 x 353 120v~1PN&E, 60Hz 2@1/8 2.4 9.0 2500 35 56 83 x 14 x 8 83.5 x 13.9 1770 1470 77 C1000E 1200 x 347 x 205 1209 x 353 208v~3PN&E, 60Hz 1@1/8 4.5/9 *27 9.0 1250 20 55 47 x 13 x 8 47.6 x 13.9 15,370/30,735 1770 740 44 C1500E 1600 x 347 x 205 1609 x 353 208v~3PN&E, 60Hz 1@1/8 6/12 *36 9.0 1800 27 55 63 x 14 x 8 63.4 x 13.9 20,490/40,980 1770 1060 60 C2000E 2100 x 347 x 205 2120 x 353 208v~3PN&E, 60Hz 2@1/8 9/18 *54 9.0 2500 37 56 83 x 14 x 8 83.5 x 13.9 30,735/61,470 1770 1470 82 lphw C1000W 1200 x 347 x 205 1209 x 353 120v~1PN&E, 60Hz 1@1/8 6 1.2 8.5 1180 22 55 47 x 13 x 8 47.6 x 13.9 20,490 1670 700 49 C1500W 1600 x 347 x 205 1609 x 353 120v~1PN&E, 60Hz 1@1/8 9 1.9 8.5 1700 30 55 63 x 14 x 8 63.4 x 13.9 30,735 1670 1000 66 C2000W 2100 x 347 x 205 2120 x 353 120v~1PN&E, 60Hz 2@1/8 12 2.4 8.5 2360 41 56 83 x 14 x 8 83.5 x 13.9 40,980 1670 1400 90 ** Sound pressure levels (dba) at 3m, as given in the brochure, are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several db higher if the mounting height is reduced, if the room is more live (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. Noise levels will also increase if more than one air curtain is installed at the same doorway (e.g. + 3dBA for 2 equal point sources: direct field). 12-8 www.eccosupply.ca

technical data (cont d) -range surface mounted ange Surface Mounted 600 volt Models dimensions Supply # Heat loading Max. Max. Air Weight **db(a) Metric (l x d x W) Motors Output per (A) velocity volume (kg)/ @3m Imperial (mm)/(in) @HP (kw)/(btu/hr) current (m/s)/ (m 3 /h)/ (lbs) draw (ft/min) (ft 3 /min) PHv1000E NT 1196 x 377 x 255 600v~3P&N, 60Hz 1@1/4 6/12 *12.7 11.5 2880 31 59 47 x 15 x 10 20,490/40,980 2260 1700 68 PHv1500E NT 1746 x 377 x 255 600v~3P&N, 60Hz 1@1/3 9/18 *19.5 11.5 4020 48 60 69 x 15 x 10 30,735/61,470 2260 2370 106 PHv2000E NT 2296 x 377 x 255 600v~3P&N, 60Hz 2@1/4 12/24 *25.4 11.5 5760 64 61 90 x 15 x 10 40,980/81,970 2260 3390 140 ange Surface Mounted 120-208 volt Ambient PHv1000A NT 1196 x 377 x 255 120v~1P&N, 60Hz 1@1/3 3.0 12 2880 29 59 47 x 15 x 10 2360 1700 64 PHv1500A NT 1746 x 377 x 255 120v~1P&N, 60Hz 1@1/3 4.0 12 4020 43 60 69 x 15 x 10 2360 2370 95 PHv2000A NT 2296 x 377 x 255 120v~1P&N, 60Hz 2@1/3 6.0 12 5760 58 61 90 x 15 x 10 2360 3390 128 PHv1000E NT 1196 x 377 x 255 208v~3P&N, 60Hz 1@1/3 5.5/11 *33 12 2880 32 59 47 x 15 x 10 18,750/37,570 2360 1700 71 PHv1500E NT 1746 x 377 x 255 208v~3P&N, 60Hz 1@1/3 9/18 *54 12 4020 45 60 69 x 15 x 10 30,735/61,470 2360 2370 99 PHv2000E NT 2296 x 377 x 255 208v~3P&N, 60Hz 2@1/3 11/22 *66 12 5760 62 61 90 x 15 x 10 37,570/75,130 2360 3390 137 lphw PHv1000W NT 1196 x 377 x 255 120v~1PN&E, 60Hz 1@1/3 12 3.0 11 2630 32 59 47 x 15 x 10 40,980 2170 1550 70 PHv1500W NT 1746 x 377 x 255 120v~1PN&E, 60Hz 1@1/3 18 4.0 11 3670 50 60 69 x 15 x 10 61,470 2170 2160 110 PHv2000W NT 2296 x 377 x 255 120v~1PN&E, 60Hz 2@1/3 24 6.0 11 5260 66 61 90 x 15 x 10 81,970 2170 3095 145 ** Sound pressure levels (dba) at 3m, as given in the brochure, are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several db higher if the mounting height is reduced, if the room is more live (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. Noise levels will also increase if more than one air curtain is installed at the same doorway (e.g. + 3dBA for 2 equal point sources: direct field). www.eccosupply.ca 12-9

technical data (cont d) -range recessed ange ecessed 600 volt Models dimensions Supply # Heat loading Max. Max. Air Weight **db(a) Metric (l x d x W) Motors Output per (A) velocity volume (kg)/ @3m Imperial (mm)/(in) @HP (kw)/(btu/hr) current (m/s)/ (m 3 /h)/ (lbs) draw (ft/min) (ft 3 /min) PHv1000E 1150 x 436 x 296 600v~3P&N, 60Hz 1@1/4 6/12 *12.7 11 2750 42 59 45 x 17 x 12 20,490/40,980 2170 1620 93 PHv1500E 1650 x 436 x 296 600v~3P&N, 60Hz 1@1/3 9/18 *19.5 11 3840 57 60 65 x 17 x 12 30,735/61,470 2170 2260 126 PHv2000E 2240 x 436 x 296 600v~3P&N, 60Hz 2@1/4 12/24 *25.4 11 5500 76 61 88 x 17 x 12 40,980/81,970 2170 3240 168 ange ecessed 120-208 volt Ambient PHv1000A 1150 x 436 x 296 120v~1P&N, 60Hz 1@1/3 3.0 11 2750 38 59 45 x 17 x 12 2170 1620 84 PHv1500A 1650 x 436 x 296 120v~1P&N, 60Hz 1@1/3 4.0 11 3840 51 60 65 x 17 x 12 2170 2260 112 PHv2000A 2240 x 436 x 296 120v~1P&N, 60Hz 2@1/3 6.0 11 5500 68 61 88 x 17 x 12 2170 3240 150 PHv1000E 1150 x 436 x 296 208v~3P&N, 60Hz 1@1/3 5.5/11 *33 11 2750 42 59 45 x 17 x 12 18,750/37,570 2170 1620 93 PHv1500E 1650 x 436 x 296 208v~3P&N, 60Hz 1@1/3 9/18 *54 11 3840 57 60 65 x 17 x 12 30,735/61,470 2170 2260 126 PHv2000E 2240 x 436 x 296 208v~3P&N, 60Hz 2@1/3 11/22 *66 11 5500 76 61 88 x 17 x 12 37,570/75,130 2170 3240 168 lphw PHv1000W 1150 x 436 x 296 120v~1PN&E, 60Hz 1@1/3 12 3.0 11 2630 32 59 45 x 17 x 12 40,980 2170 1550 70 PHv1500W 1650 x 436 x 296 120v~1PN&E, 60Hz 1@1/3 18 4.0 11 3670 50 60 65 x 17 x 12 61,470 2170 2160 110 PHv2000W 2240 x 436 x 296 120v~1PN&E, 60Hz 2@1/3 24 6.0 11 5260 66 61 88 x 17 x 12 81,970 2170 3095 145 ** Sound pressure levels (dba) at 3m, as given in the brochure, are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several db higher if the mounting height is reduced, if the room is more live (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. Noise levels will also increase if more than one air curtain is installed at the same doorway (e.g. + 3dBA for 2 equal point sources: direct field). 12-10 www.eccosupply.ca

technical data (cont d) jet range Jet ange Models dimensions Supply Heat Output Amp draw Max. Max. Air Weight **db(a) (l x d x W) (kw) velocity volume (kg) @3m (mm) (m/s) (m 3 /h) JET 3 600 x 120 x 201 208v~1Ph, 60Hz 1.13-2.25 12 6.0 200 4.5 46.5 JET 6 800 x 120 x 201 208v~1Ph, 60Hz 2.46-4.91 25 8.0 370 5.5 56.0 Jet ange GA Drawing al Supply unit Model A B Jet 3 600 425 Jet 6 800 625 al Supply unit Wall or ceiling mounting options Figure 1: Mounting Bracket Alignment Mounting Bracket Access for Screwdriver through end cap Internal Hanging Bracket Serrated Washer Figure 2: Cross section view & mounting bracket Typical Installation - Wall Mounting 1. Use mounting bracket as template and mark two fixing holes on wall or ceiling. 2. Drill mounting holes and secure bracket into position. 3. Hang the unit and secure fastening hardware. 4. Open power connection plate. 5. Connect electrical supply. 6. Close power connection plate and secure cable gland. A combination of units joined end to end will provide coverage on greater spans. ** Sound pressure levels (dba) at 3m, as given in the brochure, are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several db higher if the mounting height is reduced, if the room is more live (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. Noise levels will also increase if more than one air curtain is installed at the same doorway (e.g. + 3dBA for 2 equal point sources: direct field). www.eccosupply.ca 12-11