MINIMIZE WORKFLOW INTERRUPTIONS

Similar documents
Consumables and Supplies Required for Repair

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

AVIO 200/500 ICP-OES CONSUMABLES AND SUPPLIES. Consumables and Supplies Reference Guide

HP 1946A LC/MSD Replacement Parts

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Application for Energy and Fuels

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

PHI 5000 VersaProbe III

Quick Reference Guide. Supplies for Waters HPLC Systems

PHI 5000 VersaProbe III

PHI Quantera II Consumable Parts List

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent

Chemical and Petrochemical Applications of Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

GLASS EXPANSION NEWSLETTER

Deep groove ball bearings L12DDU. Polyolefin is used for packaging food in supermarkets, replacing dioxin-generating vinyl chloride.

PHI 5000 VersaProbe II Consumable Parts List

How to Operate the Nu Plasma MC-ICP-MS. A quick guide

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

Application for Energy and Fuels

U-5000AT Ultrasonic Nebulizer Operator s Manual

Section Title Page. 1 INTRODUCTION Scope of this manual Applicability Parts list 1. 2 QDP AND iqdp40 PUMP ASSEMBLY 2

Liquid Chromatography Mass Spectrometry LCMS Consumables SSI-LCMS

MODEL GLC PARTS MANUAL REV.1.02A

PHI 5000 VersaProbe II Consumable Parts List

ABB life cycle services Uninterruptible power supplies

Recommended Spare Parts Lists

KH SWCNT. High Quality in Mass Quantity for Industrial Use

See Water Gauge/Liquid Level Catalog (PHBRWGA) for more detailed information about the products in this section.

High Performance Laser Consumables

Bellows Pumps. The Newest Technology in Piston Pumps

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Type 441 XXL 442 XXL. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Type 431, 433. Balanced bellows design. Type Cap H2. 18 Adjusting screw with bushing. 19 Lock nut. 16 Upper spring plate. 12 Spindle.

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN

Choose for Your Instrument

SJP Vertical Propeller Pumps

Self-priming pump «Wilo-Drain SP» Technical Presentation of the new pump Wilo-Drain SP 24/07/2013 Olivier Rieu

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Type 427, 429. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Agilent 1290 Infinity Autosampler

VM / VML COMPONENT PARTS CATALOGUE

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

Roll Length (Feet) 6300 Polyethylene Pipe

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Type 431, 433. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

EPOND SA CP 389 CH Vevey Switzerland.

Vessels and Distillation Equipment

Type 431, 433. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

AccuSputter AW 4450-Series Sputtering Deposition Systems

DONALDSON DELIVERS A single source for on-road engine filtration

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics

TOTAL CONTROL. Total Control Components Pool Chemistry Controller Salt Chlorine Generator Acid Feeder Relay Box (optional)

Xtreme NEW GENERATION XTREME FINISHES DESIGN ROBUSTNESS ADVANTAGES ERGONOMICS COMPROMISE TECHNOLOGY SOLUTIONS INNOVATION EVOLUTION WARRANTY QUALITY

Service Parts. John Deere 6068HFG08. Engine. Engine Models: Generator Models: 125/150REOZJ4 145/175REOZT4 TP /15

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C

Installing the Dionex ICS-1100/1600/2100 Auxiliary Valve

Water Purification Parts

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

Goulds Small Capacity Double Suction Pump

75L & 100L JACKETED ASSEMBLY INSTRUCTIONS FOR PROCESS REACTOR SYSTEMS N. Mill Road Vineland, NJ Phone: Fax:

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Stainless Steel. Tube, Pipe. Fittings

Delivering unsurpassed quality, design and value.

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Type. Type 457, , 458. Flanged Safety Relief Valves spring loaded

Tube Replacement (Silicone) TDF

Hydrosafe - Model HSFS

Replacement Parts & Accessories for ASE Systems

Maintenance Instructions

Type 455, 456. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. US Units

Fibertec 8000 Fully automated Crude and Detergent Fibre analysis

Plasma Cutting. Futuris Plasma torches and replacement parts are not genuine OEM products. Reference to OEM parts is for ease of use only.

Coflore. ACR Catalogue. AM Technology. Engineering Chemistry

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

PLUMBING WHOLESALE CATALOG

COMPACT WHEEL LOADERS before PIN BH - before PIN Parts Catalog Ingersoll HOME TRACTORS ATTACHMENTS INDEX ENGINES

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

MODELNO~. 1_2_ 7_F_T_2 _3_1_7-_1_2 PARTNO~. 4_2_6_21_8_7 DATE ~2~4_-0~8~-~20~O~1. T20000 Series REFERENCE ONLY GRP-T

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Type 459. Type 459. Available designs. Cap H2. with bushing 19. Lock nut. Bonnet. Outlet flange 2.4 Outlet adaptor 2.1. spacer.

Empire Abrasive Equipment Cartridge Filter Collector EM 2-2 and EM 2-4

The Next Generation. Formulatory Expertise & Comprehensive Technical Support

Section Top Cover Assembly

Carousel Model AGB Whirlpool Model AGB Whirlpool with Scale Model AGB Hydrosound Model AGB Hydrosound with Scale

ChemWell Replacement Parts & Accessories

PRESS P/N - P/N ECO SERIES

0 900 psi Pressure-Reducing Diaphragm Regulator

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Transcription:

MINIMIZE WORKFLOW INTERRUPTIONS Operating Supplies Kits for Agilent ICP-MS Reduce costs while ensuring long-term confidence in your results Your Agilent ICP-MS instrument was engineered and manufactured to deliver superb performance. Don t risk the quality and reliability of your results, as well as possible instrument downtime, by using non-agilent supplies. You ll find that using authentic Agilent ICP-MS operating supplies kits will enable you to: Maintain accurate analysis Save as much as 15% over the cost of purchasing supplies individually Keep your instruments running for up to 12 months (depending on use) without worrying about reordering supplies On the following pages you ll find a full portfolio of genuine Agilent ICP-MS operating supplies, listed by instrument. Identify the model you are using and make your selections. Increase flexibility with Agilent configurable operating supplies kits In addition to time and cost savings, you can configure the contents of these kits for your specific instrument configuration and application. That means you can select the type and quantity of sampling cones, skimmer cones, and other supplies you need. These flexible supplies kits are available for: Agilent 7700/7800/7900 Single-Quadrupole ICP-MS systems fitted with x-lens Agilent 8800/8900 Triple-Quadrupole ICP-QQQ systems Agilent 7700s/7900s and 8800/8900 semiconductor ICP-MS systems fitted with s-lens These are not just parts and supplies, they are essential components which guarantee the performance, reliability, and longevity of your instrument.

Enjoy cost-effective and reliable supplies kits BASIC SUPPLIES KIT Part Number G3280-67003 For Agilent 7700/7900 and 8800 ICP-MS fitted with x-lens and Edwards E2M18 roughing pump using Inland 45 pump oil Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard, Tygon, 2-stop, blue/orange, 12/pk; PFA sample tubing, 0.5 mm id, 1.6 mm od, 5 m; graphite gasket for sampling cone, 3/pk; rough pump oil, Inland 45, 1 qt; and torch with 2.5 mm id injector. G3280-67221 For Agilent 7700/7800/7900 and 8800/8900 ICP-MS fitted with x-lens and roughing pump using AVF 60 SHCE pump oil Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard, Tygon, 2-stop, blue/orange, 12/pk; PFA sample tubing, 0.5 mm id, 1.6 mm od, 5 m; graphite gasket for sampling cone, 3/pk; rough pump oil, AVF 60 SHCE, 1 L; and torch with 2.5 mm id injector. COMPREHENSIVE OPERATING SUPPLIES KITS Part Number G3280-67085 For Agilent 7700e ICP-MS with Edwards E2M18 roughing pump using Inland 45 pump oil Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard, Tygon, 2-stop, blue/ orange, 2 x 12/pk; PFA sample tubes, 0.5 mm id, 1.6 mm od, 5 m; sample inlet tubing, 0.5 mm id for MicroMist nebulizer; online internal standard addition kit; drain tube assembly; spray chamber; spray chamber drain tubing; connector tube; nebulizer carrier gas connector; spray chamber clamps, 2/pk; carrier gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; plasma/auxiliary gas tubes with inner sleeve; gas line connector; RF coil; graphite gasket for sampling cone, 3/pk; 2 x Ni sampling cones; 2 x Ni skimmer cones; screw and spacer kit for x-lens 2/pk; screw and spacer O-ring; PTFE tubing for internal reaction gas line; Octopole assembly; polishing paper kit 5 sheets No. 400+1200; oil mist filter element; 2 packs rough pump oil, Inland 45, 1 quart. G3280-67004 For Agilent 7700x/e and 8800 ICP-MS fitted with x-lens and Edwards E2M18 roughing pump using Inland 45 pump oil Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard, Tygon, 2-stop, blue/ orange, 2 x 12/pk; PFA sample tubes, 0.5 mm id, 1.6 mm od, 5 m; sample inlet tubing, 0.5 mm id, for MicroMist nebulizer; online internal standard addition kit; drain tube assembly; spray chamber; spray chamber drain tubing; connector tube with dilution port; dilution gas connector; nebulizer carrier gas connector; dilution gas port plug; spray chamber clamps, 2/pk; carrier gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; plasma/auxiliary gas tubing with inner sleeve; gas line connector; RF coil; graphite gasket for sampling cone, 3/pk; 2 x Ni sampling cones; 2 x Ni skimmer cones; screw and spacer kit for x-lens; screw and spacer O-ring; PTFE tubing for internal reaction gas line; Octopole assembly; polishing paper kit 5 sheets No. 400+1200; oil mist filter element; 2 packs rough pump oil, Inland 45, 1 quart. 2

G3280-67007 For Agilent 7700s and 8800 semiconductor ICP-MS fitted with s-lens and Edwards E2M18 roughing pump using Inland 45 pump oil Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard, Tygon, 2-stop, blue/ orange, 2 x 12/pk; PFA sample tubes, 0.5 mm id, 1.6 mm od, 5 m; online internal standard addition kit; drain tube assembly; spray chamber; spray chamber drain tubing; connector tube with dilution port; dilution gas connector; nebulizer carrier gas connector; dilution gas port plug; spray chamber clamps, 2/pk; carrier gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; plasma/auxiliary gas tubes with inner sleeve; gas line connector; RF coil; graphite gasket for sampling cone, 3/pk; Pt sampling cone; Pt skimmer cone; screw and spacer kit for s-lens; screw and spacer O-ring; PTFE tubing for internal reaction gas line; Octopole assembly; polishing paper kit 5 sheets No. 400+1200; oil mist filter element; 2 packs rough pump oil, Inland 45, 1 quart. CONFIGURABLE OPERATING SUPPLIES KITS Configurable operating supplies kits for Agilent ICP-MS allow you to choose the skimmer and sampling cones, ion lenses, and roughing pump oil supplied with the kit to suit your application needs. Please follow the steps below to configure your kits. Part Number G3690A For Agilent 7700x/e and 8800 ICP-MS systems fitted with x-lens Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard Tygon, 2-stop, blue/ orange, 2 x 12/pk; PFA sample tubing, 0.5 mm id, 1.6 mm od, 5 m; sample inlet tubing, 0.5 mm id, for MicroMist nebulizer, 10/pk; online internal standard addition kit; drain tubing assembly; spray chamber; tubing for drainage, 4.0 mm id, 2.5 m; quartz connector tube with dilution port; gas connector for dilution gas port; nebulizer EzyLok gas connector; plug for dilution port, 4 mm; clamps for spray chamber, 2/pk; carrier/make-up/dilution gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; plasma/auxiliary gas tubing with inner sleeve; connectors for plasma/auxiliary gas; RF coil; graphite gasket for sampling cone, 3/pk; screw and spacer kit for x-lens; screw/spacer/o-ring for cell; PTFE tubing for reaction cell gas, Octopole assembly; polishing paper kit 5 sheets No. 400+1200. Step 1: Choose one of the options below to select your sampling cone. G3690A#100 G3690A#101 G3690A#102 Add Ni sampling cone for 7700/8800 (bundles p/n G3280-67040 with the kit) Add Ni plated sampling cone for 7700/8800 (bundles p/n G3280-67061 with the kit) Add Pt sampling cone for 7700/8800 (bundles p/n G3280-67036 with the kit) For samples containing >0.5% HCl, or for HMI operation with maximum aerosol dilution ratio Required when running HF or aqua regia digests Note: If you have selected a part from the pale green rows in Step 1, the part from the pale green row in Step 2 is the recommended option. Similarly, if you selected a part from the darker green row in Step 1, the part from the darker green row in Step 2 is the recommended option. Continued on next page > 3

Step 2: Choose one of the options below to select your skimmer cone. G3690A#200 G3690A#201 Add Ni skimmer cone for 7700/8800 (bundles p/n G3280-67041 with the kit) Add Pt skimmer cone for 7700/8800 (bundles p/n G3280-67060 with the kit), This option also requires the brass skimmer base (p/n G3280-60621 not included in kit) Required when running HF or aqua regia digests Step 3: Choose one of the options below to select the correct oil/filter element for the roughing pump. G3690A#300 G3690A#302 Adds 2 packs Inland 45 oil, 1 Quart, (p/n 6040-0834) and oil mist filter element (p/n 1535-4970) Adds 2 packs AVF 60 SHCE oil, 1 L, (p/n X3760-64004) and oil mist filter element (p/n 9499201) Suits Edwards E2M18 roughing pump Suits Agilent MS40+ roughing pump Once you have selected your preferred options, please contact your Agilent Representative or Agilent Authorized Distributor to place your order. Configurable kits cannot be ordered through the online store. 4

Part Number G1131A For Agilent 7900 ICP-MS systems fitted with x- or s-lens Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard Tygon, 2-stop, blue/orange, 2 x 12/pk; PFA sample tubing, 0.5 mm id, 1.6 mm od, 5 m; online internal standard addition kit; drain tubing assembly; spray chamber for UHMI; tubing for drainage, 4.0 mm id, 2.5 m; quartz connector tube, straight; gas connector for dilution gas port; dilution nozzle, UHMI; plug for dilution port, 4 mm; clamp, torch ball joint connector, 2/pk; carrier/ make-up dilution gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; low impurity gas tubing kit; connectors for plasma/auxiliary gas; work coil assembly; graphite gasket for sampling cone, 3/pk; screw/spacer/o-ring for cell; tubing for reaction cell gas; Octopole assembly; polishing paper kit 5 sheets No. 400+1200; exhaust filter for MS40+ roughing pump. Step 1: Choose your type of kit based on x- or s-lens G1131A#100 G1131A#101 Includes: UniFit sample connector, 0.5 mm id, 10/pk (G3266-80012); nebulizer EzyLok gas connector (G3266-80015): Screw and spacer kit for x-lens (G8400-67003) Includes: Carrier gas line connector Microflow nebulizer (G1833-65583); screw and spacer kit for s-lens, (G3280-67038) Mandatory option for a 7900 with x-lens. If you choose this option then options #200 or #201 and #300 are recommended. If running HF digests, options #202 and #302 are recommended Mandatory option for a 7900 with s-lens. If you select this option then options #202 and #303 are recommended. If running aggressive semiconductor samples, options #203 and #303 are recommended Note: If you have selected a part from the pale green row in Step 1, the parts from the pale green rows in Steps 2 and 3 are the recommended options. Similarly, if you selected a part from the darker green row in Step 1, the parts from the darker green rows in Steps 2 and 3 are the recommended options. Step 2: Choose one of the options below to select your sampling cone G1131A#200 G1131A#201 G1131A#202 G1131A#203 Add Ni sampling cone for 7900, (bundles p/n G3280-67040 with the kit) Add Ni plated sampling cone for 7900, (bundles p/n G3280-67061 with the kit) Add Pt sampling cone for 7900, (bundles p/n G3280-67036 with the kit) Add Pt sampling cone (18 mm insert) for 7900, (bundles p/n G3280-67056 with the kit) For samples containing >0.5% HCl, or for HMI operation with maximum aerosol dilution ratio Required when running HF digests or semiconductor samples Recommended for aqua regia digests Continued on next page > 5

Step 3: Choose one of the options below to select your skimmer cone G1131A#300 G1131A#301 G1131A#302 G1131A#303 G1131A#304 Add Ni skimmer cone for 7900 with x-lens (bundles p/n G8400-67200 with the kit) Add Pt skimmer cone with Cu base and brass skimmer base for 7900 with x-lens (bundles p/n G8400-67201 and G8400-60625 with the kit) Add Pt skimmer cone with Ni base and brass skimmer base for 7900 with x-lens (bundles p/n G8400-67202 and G8400-60625 with the kit) Add Pt skimmer cone for 7900 with s-lens (bundles p/n G3280-67064 with the kit) Add Ni skimmer cone and stainless steel skimmer base for 7900 with s-lens (bundles p/n G3280-67066 and G8400-60627 with the kit) Recommended for the lowest LODs and for higher matrix samples (such as HF digested geological samples) Recommended for analysis of organic solvents Required when running HF digests or semiconductor samples Provides lowest cost interface for applications where lowest LODs are not required Step 4: Choose this option below to include oil for the roughing pump G1131A#402 Adds 2 packs AVF 60 SHCE oil, 1 L, (p/n X3760-64004) Suits Agilent MS40+ roughing pump Once you have selected your preferred options, please contact your Agilent Representative or Agilent Authorized Distributor to place your order. Configurable kits cannot be ordered through the online store. 6

Part Number M5141A For Agilent 7800 ICP-MS system fitted with x- lens Includes: peristaltic pump tubes for sample, Tygon, 3-stop, white/white, 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene, 3-stop, yellow/blue, 12/pk; peristaltic pump tubes for internal standard, Tygon, 2-stop, blue/ orange, 2 x 12/pk; PFA sample tubing, 0.5 mm id, 1.6 mm od, 5 m; UniFit sample connector, 0.5 mm id, 10/pk; online internal standard addition kit; drain tubing assembly; spray chamber; tubing for drainage, 4.0 mm id, 2.5 m; quartz connector tube with dilution port; gas connector for dilution gas port; nebulizer EzyLok gas connector; plug for dilution port, 4 mm; clamps for spray chamber, 2/pk; carrier/make-up dilution gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; low impurity gas tubing kit; connectors for plasma/auxiliary gas; work coil assembly; graphite gasket for sampling cone, 3/pk; screw and spacer kit for x-lens; screw/spacer/o-ring for cell; PTFE tubing for reaction cell gas; Octopole assembly; polishing paper kit 5 sheets No. 400+1200; exhaust filter cartridge; 2 packs rough pump oil, AVF 60 SHCE, 1 L. Step 1: Choose one of the options below to select your sampling cone M5141A#100 M5141A#101 M5141A#102 M5141A#103 Add Ni sampling cone for 7800, (bundles p/n G3280-67040 with the kit) Add Ni plated sampling cone for 7800, (bundles p/n G3280-67061 with the kit) Add Pt sampling cone for 7800, (bundles p/n G3280-67036 with the kit) Add Pt sampling cone (18 mm insert) for 7800, (bundles p/n G3280-67056 with the kit) For samples containing >0.5% HCl, or for HMI operation with maximum aerosol dilution ratio Required when running HF digests or semiconductor samples Recommended for aqua regia digests Note: If you have selected a part from the pale green rows in Step 1, the part from the pale green row in Step 2 is the recommended option. Similarly, if you selected a part from the darker green row in Step 1, the part from the darker green row in Step 2 is the recommended option. Step 2: Choose one of the options below to select your skimmer cone M5141A#200 M5141A#201 M5141A#202 Add Ni skimmer cone for 7800 (bundles p/n G3280-67041 with the kit) Add Pt skimmer cone and brass skimmer base for 7800 (bundles p/n G3280-67060 and G3280-60621 with the kit) Add Pt skimmer cone with Ni base and brass skimmer base for 7800 (bundles p/n G3280-67063 and G3280-60621 with the kit) Recommended for the lowest LODs and for higher matrix samples (such as HF digested geological samples) Recommended for analysis of organic solvents Once you have selected your preferred options, please contact your Agilent Representative or Agilent Authorized Distributor to place your order. Configurable kits cannot be ordered through the online store. 7

Part Number G1091A For 8900 ICP-MS systems fitted with x- or s-lens Includes: peristaltic pump tubes for sample, Tygon 3-stop white/white 2 x 12/pk; peristaltic pump tubes for waste, Ismaprene 3-stop yellow/blue 12/pk; peristaltic pump tubes for internal standard, Tygon 2-stop blue/ orange flared 2 x 12/pk; PFA sample tubes, 0.5 mm id, 1.6 mm od, 5 m length; on-line internal standard addition kit; drain tube assembly; tubing for spray chamber drain (4.0 mm id, 2.5 m); clamp, torch ball joint connector, 2/ pk; carrier/make-up/dilution gas tubing; torch with 2.5 mm id injector; long-life Pt shield plate; quartz bonnet for shield torch; plasma/auxiliary low impurity gas tubing kit with inner sleeves; connectors for plasma and auxiliary gas; work coil assembly; graphite gasket for sampling cone, 3/pk; tubing for reaction cell gas; Polishing paper kit, 5 sheets No. 400 + 1200; exhaust filter for MS 40+ roughing pump; 2 packs AVF 60 SHCE oil, 1 L bottle Step 1: Choose at least one of the following options to select the sample cone supplied G1091A#100 G1091A#101 G1091A#102 G1091A#103 Add Ni sampling cone for 8900 (bundles p/n G3280-67040 with the kit) Add Ni plated sampling cone for 8900 (bundles p/n G3280-67061 with the kit) Add Pt sampling cone for 8900 (bundles p/n G3280-67036 with the kit) Add Pt sampling cone (18 mm insert) for 8900 (bundles p/n G3280-67056 with the kit) For samples containing >0.5% HCl, or for (U)HMI operation with maximum aerosol dilution ratio Required when running HF digests or semiconductor samples Recommended for aqua regia digests Note: If you have selected a part from the pale green rows in Step 1, the parts from the pale green rows in Steps 2-4 are the recommended options. Similarly, if you selected a part from the darker green row in Step 1, the parts from the darker green rows in Step 2-4 are the recommended options. Step 2: Choose at least one of the following options to select the skimmer cone supplied G1091A#200 G1091A#201 G1091A#202 Add Ni skimmer cone for 8900 with x-lens (bundles p/n G8400-67200 with the kit) Add Pt skimmer cone with Cu base for 8900 with x-lens (bundles p/n G8400-67201 + G3666-60311 with the kit) Add Pt skimmer cone with Ni base for 8900 with x-lens (bundles p/n G8400-67202 + G3666-60311 with the kit) Recommended for the lowest LODs and for higher matrix samples (such as HF digested geological samples) Recommended for analysis of organic solvents 8 Continued on next page >

G1091A#203 G1091A#204 G1091A#205 Add Ni skimmer cone for 8900 with s-lens (bundles p/n G3666-67421 with the kit) Add Pt skimmer cone with Cu base for 8900 with s-lens (bundles p/n G3666-67401 with the kit) Add Pt skimmer cone with Ni base for 8900 with s-lens (bundles p/n G3666-67411 with the kit) Provides lowest cost interface for applications where lowest LODs are not required Recommended for the lowest LODs when running semiconductor samples. Recommended for analysis of organic solvents Step 3: Choose the correct one of the following options to select the sample and gas connectors and screw/spacer kit supplied for the type of lens configuration G1091A#300 G1091A#301 Includes: Unifit sample connector (p/n G3266-80012); gas connector for nebulizer (p/n G3266-80017); screw and spacer kit (p/n G8400-67003); spray chamber with UHMI (p/n G8400-67150); dilution nozzle, UHMI (p/n G8400-67026); gas connector, dilution gas port (p/n 0100 2703); blank plug for dilution port, PTFE (p/n G3666-20391) Includes: carrier gas line connector (p/n G1833-65583); screw and spacer kit (p/n G3666-67038); spray chamber (without UHMI) (p/n G3280-80008) Mandatory option for 8900 with x-lens configured for standard or advanced application Mandatory option for 8900 with s-lens configured for semiconductor applications Step 4: Choose the correct one of the following options to select the octopole assembly for the instrument configuration G1091A#401 G1091A#400 Includes: Octopole assembly without axial accelerator for 8900 (p/n G3666-67046); screw/ spacer/o-ring for 8900 for cell without axial accelerator (p/n G3666-67044); quartz connector tube straight (p/n G3270-80025) Includes: Octopole assembly with axial accelerator for 8900 (p/n G3666-67045); screw/spacer/oring for 8900 for cell with axial accelerator (p/n G3666-67049); quartz connector tube, dilution, HMI kit (p/n G3270-80024); plug for dilution port (p/n G3280-20576); gas connector for dilution gas port (p/n 0100 2583) Mandatory option for 8900 with standard configuration (with ORS without axial acceleration) Mandatory option for 8900 configured for advanced or semiconductor application (with ORS with axial acceleration) Once you have selected your preferred options, please contact your Agilent Representative or Agilent Authorized Distributor to place your order. Configurable kits cannot be ordered through the online store. 9

Agilent Atomic Spectroscopy Portfolio: Leading the way in atomic spectroscopy innovation Agilent has changed the atomic spectroscopy landscape. Remarkable innovations like the ICP-QQQ, 5110 SVDV ICP-OES, and MP-AES have added even more application opportunities to those already offered by Agilent ICP-MS, and AA instrument solutions. Find out how Agilent s Atomic Spectroscopy Solutions can deliver more possibilities for your lab. Learn more: www.agilent.com/chem/atomic Trust Agilent to keep your lab running at peak productivity Agilent s Advantage Service protects your investment in Agilent instruments and connects you with our global network of experienced professionals who can help you get the highest performance from every system in your lab. Count on us for the services you need at every stage of your instrument s life from installation and upgrade to operation, maintenance, and repair. For customers who require full system validation, Agilent offers complete qualification services for most Atomic Spectroscopy instruments. What s more, if your Agilent instrument ever requires service while covered by an Agilent service agreement, we guarantee repair or we will replace your instrument for free. No other manufacturer or service provider offers this level of commitment. Count on genuine Agilent Operating Supplies Kits for Agilent ICP-MS Learn more, visit www.agilent.com/chem/atomic Or find your local Agilent Representative or Agilent Authorized Distributor at www.agilent.com/chem/contactus Agilent products are for research use only. Not for use in diagnostic procedures. Information, descriptions and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2017 Printed in the USA, 19 May, 2017 5991-5006EN