Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Similar documents
Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Digitrip Retrofit System for BBC LKD 8 Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

IL 33-DRC-1 Retrofit System for Westinghouse and Cutler-Hammer DS Power Circuit Breakers. Table of Contents

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Two-way cable interlock kit for Magnum fixed circuit breakers

Two-way cable interlock kit for Magnum drawout circuit breakers

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Instruction Booklet IB E. Contents

CM52 Network Protector with Arc Flash Reduction Module

Factory Authorized Mechanism Enhancement (FAME)

CCP2-FLR1-21_ flange-rod operating mechanism

O & M Manual for the EATON Generator Ready Loadcenter

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

3-way multi-family drawout cable interlock kit - type 32 - RF

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Advanced Test Equipment Rentals ATEC (2832)

38 kv Type VCPW-HD Simple Electrical Ground & Test Device (SEG&TD) lower terminal instruction booklet

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Effective November 2016 Supersedes September 1998 (S )

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

Magnum Breaker Remote Racking Device (MRR1000)

Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking)

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

Freedom FlashGard Aftermarket Kit Installation Manual

Flush Mount AIN ALPHA Meters. General. Hardware Kit

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Effective June 2016 New Issue

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

High-voltage primary bushings installation instructions

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

Effective March 2015 Supersedes S August 2012

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

I.L. 29C121A WARNING 1. INTRODUCTION. Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V)

! WARNING I.L D WARNING GENERAL INFORMATION

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

Cutler-Hammer. Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N) I.L.

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

Effective May 2017 Supersedes December 2004 (S )

50 / 75 / 150 DHP [Cable or Hard Bus Application] Ground and Test Device

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Installation Instructions For Motor Control Center (MCC) Units

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

Magnum breaker remote racking device (MRR1000)

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

SPX9000 FR10 FR12 Adjustable Frequency Drives

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Freedom egen System End-of- Line Functional Checklist

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

a WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.

Transcription:

Supersedes IL 33-GS8-2 Dated 10/00 (Manually Operated Only) Contents Description Page Introduction.............................. 3 Step 1:............................... 4 Step 2:............................... 4 Step 3:............................... 5 Step 4:............................... 6 Step 5:............................... 7 Step 6:............................... 7 Step 7:............................... 9 Step 8:............................... 11 Step 9:.............................. 12 Step 10:.............................. 13 Step 11:.............................. 15 Step 12:.............................. 16 Step 13:.............................. 16 Step 14:.............................. 17 Parts List.............................. 18

WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE SIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY FEATURES INTENDED TO PROVIDE SAFE AND PROPER OPERATING SEQUENCES. TO PROVIDE MAXIMUM PROTECTION FOR PERSONNEL ASSOCIATED WITH THE INSTALLATION, OPERATION, AND MAINTENANCE OF THESE BREAKERS, THE FOLLOWING PRACTICES MUST BE FOLLOWED. FAILURE TO FOLLOW THESE PRACTICES MAY RESULT IN DEATH, PERSONAL INJURY, OR PROPERTY DAMAGE. Safety Precautions Periodic testing of this device is required (see Step 12 Testing the Breaker for test procedures). Only qualified persons, as defined in the National Electric Code, who are familiar with the installation and maintenance of power circuit breakers and their associated switchgear assemblies should perform any work associated with these breakers. Completely read and understand all instructions before attempting any installation, operation, maintenance, or modification of these breakers. Always turn off and lock out the power source feeding the breaker prior to attempting any installation, maintenance, or modification of the breaker. Do not use the circuit breaker as the sole means for isolating a high voltage circuit. Follow all lockout and tagging rules of the National Electric Code and all other applicable codes, regulations, and work rules. Do not work on a closed breaker or a breaker with the closing springs charged. Trip (open) the breaker and be sure the stored energy springs are discharged before performing any work. The breaker may trip open or the charging springs may discharge, causing crushing or cutting injuries. For drawout breakers, trip (open), and then remove the breaker to a well-lit work area before beginning work. Do not perform any maintenance: including breaker charging, closing, tripping, or any other function which could cause significant movement of the breaker while it is on the extension rails. Doing so may cause the breaker to slip from the rails and fall, potentially causing severe personal injury to those in the vicinity. Do not leave the breaker in an intermediate position in the switchgear cell. Always leave it in the connected, disconnected, or (optional) test position. Failure to do so could lead to improper positioning of the breaker and flashover, causing death, serious personal injury, and / or property damage. Do not defeat any safety interlock. Such interlocks are intended to protect personnel and equipment from damage due to flashover and exposed contacts. Defeating an interlock could lead to death, severe personal injury, and / or property damage 2 eaton corporation www.eaton.com

Instruction Leaflet IL 33-GS8-3 Section 1: Introduction Eaton Digitrip Retrofit Kits are available in a number of configurations that provide a wide range of features. The Digitrip System starts with the 510 Basic Kit that offers true RMS sensing, overcurrent protection, and self-testing features. Advanced Digitrip Retrofit Kits feature zone interlocking, digital alphanumeric displays, remote alarm signals, PowerNet communications, energy monitoring capabilities, power factors, and harmonic content measurements. Table 1 provides a quick reference of the components supplied with each level of Retrofit Kit. Before beginning the Retrofit process, take a minute to review the information contained in Table 1. It is important that the Retrofitter understands which level of Retrofit Kit is to be installed and which components are included with the Kit. The instructions contained in this manual cover the installation of all levels of Retrofit Kit. If the Kit you are installing does not contain a certain component, skip the instructions for that component and proceed to the next. Throughout the Retrofit process, refer to the Torque Tables at the back of this manual for specific torque values. If you have any questions concerning the Retrofit Kit and / or the Retrofit process, contact Eaton at: 1-800-937-5487. Table 1. Available Retrofit Kits Components Trip Unit Rating Plug Auxiliary Current Transformer (CT) Module Auxiliary CT Harness Sensors Sensor Harness Direct Trip Actuator (DTA) Mounting Brackets and Hardware 510 Basic 510 with Zone Interlock 610 810 910 External Harness Plug 1 Connector Harness 2 Connector Harness 3 Connector Harness 4 Connector Harness Cell Harness Breaker Mounted Control Power Transformer (CPT Potential Transformer (PT) Module Auxiliary Switch eaton corporation www.eaton.com 3

Step 1: General Breaker Preparation Step 2: Removing the Original Components Before attempting to remove the Breaker from the Cell or perform any Retrofit Operation, be sure to read and understand the Safety Precautions section of this manual. In addition, be sure to read and understand the Instructions for the Application of Digitrip RMS Retrofit Kits on Power Circuit Breakers (Retrofit Application Data - Publication AD 33-855), supplied with the Digitrip Retrofit Kit. WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. SEVERE PERSONAL INJURY OR DEATH CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING. A. Trip the Breaker and remove it from the Cell. Move the Breaker to a clean, well-lit work bench. Follow the G.E.Instruction Manual, originally supplied with the Breaker, to perform the following procedures. A. Remove and scrap the original Trip Unit, associated wiring, and all mounting hardware. B. Remove and scrap the original Trip Actuator and associated wiring, but save the mounting hardware. C. Remove and scrap the original Arc Chute Retaining Bar and mounting hardware. D. Remove and scrap the original Padlock Mechanism and E-clip. E. Remove and save the original Copper Connectors and all mounting hardware. F. Remove and scrap the original Sensors and Sensor Harness. Note: It is the responsibility of the Retrofitter to insure that the Breaker and all original components are in good condition. Visually inspect all Breaker components for signs of damage or wear. If any signs of damage or wear are detected for components not included in the Retrofit Kit, secure the necessary replacement parts before beginning the Retrofit Process. The Force necessary to trip the Breaker should not exceed three (3) lbs. To begin the Retrofit Process, refer to the components list at the end of this manual. Lay out the components and hardware according to the steps outlined. The components and hardware will be used to complete each step in the Retrofit Process. 4 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 Step 3: Installing the Sensor Harness D. Connect the green ground wire from the Sensor Harness (with ring terminal) to the existing hole in the Aux. CT Module as shown, using the (1).190-32.375" screw, (1) lock washer, and (1) flat washer supplied. A. Remove the Glass Poly Insulation Plate covering the 7-Point Terminal Block on the Aux. CT Module. B. Attach the left and right Aux. CT Module Mounting Brackets to the sides of the Aux. CT Module, as shown, using the (4).190-32.375" flat head screws, (4) flat washers, (4) lock washers, and (4) 0.190-32 nuts supplied. Note that the Mounting Brackets extend beyond the edges of the Aux. CT Module. Note: The Glass Poly Insulation Plate that covers the 7-Point Terminal Block should not be reinstalled until the DTA Wires have been connected later in the Retrofit Process. E. Connect the ring terminals of the Sensor Harness to the Sensors. Refer to Section 12 of the Retrofit Applications Data, supplied with the Retrofit Kit, for detailed wiring specifications. C. Connect the Sensor Harness to the 7-Point Terminal Block. Refer to Section 12 of the Retrofit Application Data, supplied with the Retrofit Kit, for detailed Wiring Specifications. Depending on the Sensors supplied with the Retrofit Kit, the following conventions apply. Sensor Style No. 4A35743H01 4A35744H01 X1-X2 = 300A X1-X3 = 600A X1-X2 = 400A X1-X3 = 800A EATON CORPORATION www.eaton.com 5

For Kits Supplied with a PT Module Only. Refer to Section 7-3, Power Flow Convention, of the Retrofit Application Data, supplied with the Retrofit Kit, for additional wiring information and to verify the Phase Convention used on this Breaker Application. C. Install a Sensor Insulator over each Breaker Stab, completely covering the Sensor. D. Reinstall the Copper Connectors removed in Step 2-E and secure using the original mounting hardware. Step 4: Installing the Sensors and Aux. CT Module A. Tilt the Breaker towards the back until it rests on the bottom Finger Clusters. This will provide access to the bottom of the Breaker. B. With the Aux. CT Module resting on the work surface, slide the Sensors onto the Breaker Stabs. The Sensor Terminals must face the bottom of the Breaker. For Kits Supplied with a PT Module Only. Do not tighten the pinch bolts that secure the Copper Connectors to the Breaker Stabs. They will be used later in the Retrofit Process to connect the PT Wires to the Copper Connectors. E. Mount the Aux. CT Module to the Breaker Back Plate using the (2).500-13 1.25" bolts, (4) flat washers, (2) lock washers, and (2).500-13 nuts supplied. 6 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 Step 5: Installing the Padlock Mechanism Step 6: Installing the DTA Assembly A. Slide the Padlock Mechanism Shaft, with the spring installed, into the original Padlock Guides, as shown. B. Compress the spring and snap the supplied E-clip into the notch on the Padlock Mechanism Shaft, then release the pressure on the spring. A. Drill and tap the two existing holes on the top of the right center Breaker Frame to accept 0.138-32 screws. B. For Kits Supplied with a Breaker Mounted CPT Only. Using Drilling Plan A, drill one (1) 0.219" diameter hole in the right Breaker Shelf. NOTE: Cover the area below the Breaker Shelf to keep metal from falling into the lower Breaker Components. Drilling Plan A Front of Breaker (As Viewed from Bottom) Existing Hole 2.37".75".59" Drill.201" Dia. (1) EATON CORPORATION www.eaton.com 7

C. Align then insert the stud on the bottom of the DTA into the existing hole in the right Breaker Shelf. E. Apply Loc-Tite 242 to the threads then secure the top of the DTA to the holes drilled and tapped in Step 6-A using the (2).138-32.375" screws, (2) lock washers, and (2) flat washers supplied. F. Apply Loc-Tite 242 to the threads then secure the DTA bottom stud using the (1) flat washer, (1) lock washer, and (1) 0.190-32 nut supplied. D. Align the top DTA mounting holes with the holes tapped in the Step 6-A. Note that slight resistance will be felt as the DTA contacts the reset pin. G. Route the DTA wires along the right side of the Breaker to the 7-Point Terminal Block mounted to the Aux. CT Module. Route them so that they are clear of all moving parts within the Breaker. Connect the + DTA Wire to the OP Terminal and the unmarked wire to the ON terminal. H. Use the nylon wire ties supplied to dress the DTA Wires to keep them away from any moving parts within the Breaker. I. Reinstall the Glass-Poly Insulation Plate over the 7-Point Terminal Block removed in Step 3-A using the original hardware. 8 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 For Kits Supplied with a Breaker Mounted CPT Only. Step 7: Installing the Breaker Mounted CPT A. Mount the CPT Mounting Bracket to the Breaker Shelf using the hole drilled in Step 6-B and the existing hole. Secure the Mounting Bracket to the Breaker Shelf, as shown, using the (2).190-32.500" screws, (4) flat washers, (2) lock washers, and (2) nuts supplied. D. Attach the HV Wires to the CPT terminals to achieve the required voltage. (See the following Table.) Standard CPT (Style #9A10037G01 & G02) Voltage Required CPT Terminals Used 480 Volt Circuit H1 & H4 240 Volt Circuit H2 & H4 208 Volt Circuit H3 & H4 Special Order 575 Volt CPT (Style #9A10037G03 & G04) Voltage Required CPT Terminals Used 575 Volt Circuit H1 & H4 460 Volt Circuit H2 & H4 230 Volt Circuit H3 & H4 E. Route the HV Line Side Wires up through the Breaker along the inside of the right Breaker Frame, through the wire clamp, and towards the appropriate Breaker Stabs. B. Secure the CPT to the CPT Mounting Bracket, as shown, using the (4).190-32.500" screws, (4) lock washers, (8) flat washers, and (4) nuts supplied. NOTE: The power convention of the Circuit Breakers is normally Top to Bottom, meaning the Top Breaker Stabs are on the Line Side of the Breaker and the Bottom Breaker Stabs are on the Load Side. C. Strip 0.250" of insulation and attach a 0.138" ring terminal to each wire of the CPT Harness. Connect the wires to the X1 and X2 terminals of the CPT. EATON CORPORATION www.eaton.com 9

The Line Side High Voltage Fused Wires (HV Wires) from the CPT MUST BE ATTACHED to the Line Side of the Breaker. If it is determined that the power flow for the Breaker application is opposite the normal convention, the HV Wires must be attached to the Bottom Breaker Stabs. In the case of the Line Side being the Bottom Breaker Stabs, the pinch bolts that secure the Copper Connectors can be used for HV Wire attachment. NOTE: If the Breaker is equipped with fuses on the Line Side of the Breaker, the hardware securing the fuses can be used to connect the HV Wires. In this case skip to Step 7-H. F. Using a 11/64" (0.172") drill bit, drill and tap the Phase 1 & 2, or 2 & 3 Breaker Stabs to accept a.190-32.375" screw. G. For Connection to the Breaker Stabs Only. Cut the Line Side HV Wires to an appropriate length for connection to the correct Breaker Stabs. Strip 0.250 from each Line Side HV Wire and attach a 0.190" ring terminal to each. Connect the Line Side HV Wires to the appropriate Breaker Stabs using the (2).190-32.375" screws, (2) lock washers, and (2) flat washers supplied. H. For Connection to the Fuse Mountings. Cut the Line Side HV Wires to an appropriate length for connection to the correct Fuse mountings. Strip 0.250" from each Line Side HV Wire and attach an appropriate size ring terminal to each. Connect the Line Side HV Wires to the correct Fuse mountings using the original hardware. I. Attach the appropriate label for the Breaker to the Breaker Cover in a clearly visible position. NOTE: It may be necessary to remove a Finger Cluster and Breaker Stab to allow the Phase 2 Breaker Stab to be drilled. WARNING THIS BREAKER CONTAINS A 50VA CONTROL POWER TRANSFORMER FOR TRIP UNIT DISPLAY. IF BREAKER IS USED ON A LINE VOLTAGE OTHER THAN SHOWN. THE CPT TAPS MUST BE CHANGED BEFORE ENERGIZING. FAILURE TO DO SO WILL RESULT IN DAMAGE TO THE TRIP UNIT AND / OR CONTROL POWER TRANSFORMER 208V CONTROL POWER TRANSF. TAPS H1 H4=480V H2 H4=240V H3 H4=208V NP# 9A10039H04 WARNING THIS BREAKER CONTAINS A 50VA CONTROL POWER TRANSFORMER FOR TRIP UNIT DISPLAY. IF BREAKER IS USED ON A LINE VOLTAGE OTHER THAN SHOWN. THE CPT TAPS MUST BE CHANGED BEFORE ENERGIZING. FAILURE TO DO SO WILL RESULT IN DAMAGE TO THE TRIP UNIT AND / OR CONTROL POWER TRANSFORMER 240V CONTROL POWER TRANSF. TAPS H1 H4=480V H2 H4=240V H3 H4=208V NP# 9A10039H03 NOTE: The Line Side High Voltage Fused Wires (HV Wires) are longer than necessary and are cut during the following steps. Before cutting the wires, be sure that sufficient length is left so that the HV Wire Fuses are accessible and that the connections can be made to the correct Breaker Stabs. WARNING THIS BREAKER CONTAINS A 50VA CONTROL POWER TRANSFORMER FOR TRIP UNIT DISPLAY. IF BREAKER IS USED ON A LINE VOLTAGE OTHER THAN SHOWN. THE CPT TAPS MUST BE CHANGED BEFORE ENERGIZING. FAILURE TO DO SO WILL RESULT IN DAMAGE TO THE TRIP UNIT AND / OR CONTROL POWER TRANSFORMER 480V CONTROL POWER TRANSF. TAPS H1 H4=480V H2 H4=240V H3 H4=208V NP# 9A10039H02 WARNING THIS BREAKER CONTAINS A 50VA CONTROL POWER TRANSFORMER FOR TRIP UNIT DISPLAY. IF BREAKER IS USED ON A LINE VOLTAGE OTHER THAN SHOWN. THE CPT TAPS MUST BE CHANGED BEFORE ENERGIZING. FAILURE TO DO SO WILL RESULT IN DAMAGE TO THE TRIP UNIT AND / OR CONTROL POWER TRANSFORMER 575V CONTROL POWER TRANSF. TAPS H1 H4=575V NP# 9A10039H01 10 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 For Kits Supplied with an Aux. Switch Only. Step 8: Installing the Aux. Switch B. Using diagonals, cut 2.50" off the Microswitch Arm. Slightly bend the Microswitch Arm to ride properly on the Breaker Cross Bar. C. Mount the Microswitch to the Aux. Switch Mounting Bracket, as shown, using the (2).138-32 1.00" screws, (4) flat washers, (2) lock washers, and (2) 0.138-32 nuts supplied. A. Using Drilling Plan B, drill two (2) 0.219" diameter holes in the top of the left Breaker Frame. Drilling Plan B Drill.219" Dia. (2) D. Mount the Auxiliary Switch Assembly to the left Breaker Frame using the holes drilled in Step 7-A and the (2).190-32.375" screws, (2) lock washers, and (2) flat washers. 1.38".31".38" Left Side of Breaker EATON CORPORATION www.eaton.com 11

For Kits supplied with a PT Module Only. Step 9: Installing the PT Module C. Mount the PT Module to the PT Module Z Mounting Bracket, as shown, using the (2).138-32.375" screws, (2) flat washers, (2) lock washers, and (2) nuts supplied. The Glass Poly Insulation Barrier must be positioned between the PT Module and the PT Module Z Mounting Bracket. A. Using Drilling Plan C, drill one 0.203" diameter hole in the right side of the rear Breaker Frame. Drilling Plan C 1.06".56" Drill.203" Dia. (1) D. Align the PT Module Assembly with the hole drilled in Step 8-A and the existing hole. Note that the PT Module Z Mounting Bracket is positioned inside the rear Breaker Frame. Mount the PT Module Assembly to the rear Breaker Frame using the (2).190-32.375" screws, (4) flat washers, and (2) lock washers supplied. Right Side of Breaker B. Remove and save the hardware securing the PT Module Connector Bracket and Guard to the mounting bracket. Remove the hardware securing the mounting bracket to the side of the PT Module. Discard the mounting bracket and hardware. Secure the Connector Mounting Bracket and Guard to the side of the PT Module, as shown, using the original hardware. 12 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 For Kits Supplied with a Breaker Mounted CPT Only. Secure the HV Wires to the Breaker using the wire clamp supplied and the top screw, lock washer, and flat washer mounting the PT Module assembly to the right rear Breaker Frame. Step 10: Installing the Trip Unit E. Route the PT Wires down along the rear Breaker Frame to the Copper Connectors. Route them so that they are clear of all moving parts within the Breaker. The PT Wires are marked for connection to Phases 1, 2, and 3 with corresponding numbers. NOTE: Before cutting the PT Wires, verify the Phase Convention used on the Breaker Application. A. Align the Arc Chute Retaining Bar with the existing studs, as shown. Route the PT Wires to a position suitable for attachment to the Copper Connectors. Move the PT Wire markers to a position where they will still be attached to the wires after cutting. Cut the wires to length, strip each wire 0.250", and install a 0.250" ring terminal on each wire. Connect the PT Wires to the pinch bolts on the Copper Connectors. B. Align the Glass Poly Insulation Barrier with the existing studs then place it against the Arc Chute Retaining Bar. Secure the Insulation Barrier and the Arc Chute Retaining Bar, using the (2) flat washers, (2) lock washers, and (2) 0.250-20 nuts supplied. Note that the two (2) small holes on the Insulation Barrier must align with the holes in the Arc Chute Retaining Bar. Use the nylon wire ties supplied to dress all wires to keep them away from any moving parts within the Breaker. EATON CORPORATION www.eaton.com 13

C. Mount the Left and Right Trip Unit Mounting Brackets to the Glass Poly Barrier, as shown, using the (4).190-32.500" screws, (4) lock washers, and (4) flat washers supplied. E. Mount the Trip Unit Support Clips to the right and left Trip Unit Mounting Brackets, as shown, using the (4).138-32.375" screws, (8) flat washers, (4) lock washers, and (4) nuts supplied. Note that the Support Clips engage the slots on both sides of the Trip Unit. D. Mount the Trip Unit to the Trip Unit Mounting Brackets, as shown, using the (2) brass spacers, (2).190-32 4.00" screws, (2) lock washers, and (2) flat washers. Note: The 4" screws are inserted from the top of the Trip Unit and the Spacers are inserted between the bottom of the Trip Unit and the Mounting Brackets. F. Remove the Trip Unit Cover and install the Rating Plug. Replace the cover. G. For Kits supplied with a PT Module Only. Install the supplied PT Module Warning Label to the upper right corner of the Glass Poly Insulation Barrier. 14 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 Step 11: Final Connection of the Harnesses and Wiring C. Insert the large plug on the Aux. CT Harness into its receptacle on the Aux. CT Module. Route the Aux. CT Harness up thorugh the Breaker to the right side of the Trip Unit. Route the harness so that it is clear of all moving parts within the Breaker. Connect the other end of the Aux. CT Harness to the male connector on the External Harness. D. For Kits Supplied with a PT Module Only. Connect the plug from the PT Module to the corresponding plug on the External Harness. E. For Kits Supplied with an Aux. Switch Only. Route the two (2) wires with ring terminals from the External Harness to the Aux. Switch. Connect one (1) wire to the normally open terminal and the other wire to the common terminal. A. Connect the External Harness to the Trip Unit. NOTE: For 510 Basic Kits, the External Harness is the plug pictured above. It is to be plugged into the right side of the Trip Unit. F. For Kits Supplied with a Breaker Mounted CPT Only. Remove the External harness plug installed in the Trip Unit. Route the CPT Harness up from the CPT to the Trip Unit. Connect the black plug of the CPT Harness into the same receptacle in the Trip Unit. Reinsert the External Harness plug just removed into the female receptacle on the CPT Harness. G. Use the nylon wire ties provided to dress all wires and harnesses to keep them away from any moving parts within the Breaker. B. Secure the External Harness to the holes in the Insulation Barrier and Arc Chute Retaining Bar using the (2) nylon wire clamps, (2).138.380" thread cutting screws, (2) lock washers, and (2) flat washers supplied. EATON CORPORATION www.eaton.com 15

Step 12: Testing the Breaker A. Measure the force necessary to trip the Breaker at the point where the DTA flange nut contacts the Trip Finger. The force necessary to trip the Breaker MUST NOT EXCEED 3 lbs. B. The Retrofit must be tested using primary injection. Refer to Section 8 of the Instructions for the Application of Digitrip RMS Retrofit Kits on Power Circuit Breakers (Publication AD 33-855), supplied with the Retrofit kit, for detailed testing procedures and specifications. For test information specific to the Trip Unit, refer to the IL publication supplied with the Retrofit kit (see the Pick List for the IL number). C. While Section 8 of the Instructions for the Application of Digitrip RMS Retrofit Kits on Power Circuit Breakers provides the information necessary for testing the Breaker, please keep the following notes in mind when reviewing other sections of the publication. CAUTION: When all testing is complete, the Trip Unit must be reset. Failure to do so may cause the Battery in the Rating Plug to run down. Notes: 1. Publication AD 33-855-1 was created specifically for the hundred series (500, 600, 700, etc.) Retrofit Kts. Therefore certain sections and figures do not apply to the ten series (510, 610, 810, etc.) Retrofit Kits. Specifically, these are Sections 13 and 14, as well as Figures 3-2, 3-3, and 3-4. 2. For All Kits Other Than 510 Basic. If testing the Breaker with Short Delay or Ground Fault functions, be sure to either plug in the Cell Harness Assembly or use the Zone Interlock Shorting Plug. Failure to do so may result in shorter than expected trip times. 3. For 810 and 910 Kits Only. Without any power applied to the system (neither the 120 volt power supply nor the Aux. Power Module connected), plug the External Harness into the Cell Harness and check the impedance between COM 1 and COM 2. The impedance should be between one (1) and three (3) ohms. If the impedance is not within this range, trace the wiring and examine each connection to assure its integrity. Confirm that the IMPACC communication wiring is correct by following the procedures detailed in Section 7.4 of the Instructions for the Application of Digitrip RMS Retrofit Kits on Power Circuit Breakers. Note that for 810 and 910 Kits, the impedance between COM 1 and COM 2 should be between one (1) and three (3) ohms. When testing is complete, disconnect the External Harness from the Cell Harness. Final External Harness connection will be performed in Step 13. For Kits Supplied with a Cell Harness Only. Step 13: Mounting the Cell Harness A. The Cell Harness is to be mounted in the Breaker Cell. The connector end is to be mounted on the right front side of the Cell, in a location suitable for connection with the External Harness. The Terminal Blocks can be mounted anywhere space is available in the Cell as long as connection to the External Harness can be made. B. Route the Cell Harness wiring to keep it away from any moveable parts within the Cell Housing. 16 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 Step 14: Installing the Retrofitted Breaker in the Cell WARNING Do not leave the Breaker in an intermediate position in the Switchgear Cell. Always leave it in the CONNECTED, DISCONNECTED, or (Optional) TEST position. Failure to do so could lead to improper positioning of the Breaker and flashover, causing death, serious personal injury, and / or property damage. NOTE: It is the responsibility of the Retrofitter to insure proper Breaker / Cell fit. When racking the Breaker into the Connected position, the Retrofitter MUST FOLLOW BOTH the manufacturer s instructions and the customer s safety standards and procedures for racking a Breaker into the Connected position. A. With the Breaker in the Open position and the springs discharged, slowly rack the Breaker into the Connected position, making sure there is no interference or binding. The Breaker should rack smoothly and without mechanical interference between any Breaker and Cell parts. The Retrofitter will feel some resistance when the primary fingers connect onto the stabs of the Cell. This is normal. However, if any unusual resistance is detected that could be abnormal interference between the Breaker and Cell parts, stop immediately and move the Breaker out of the Connected position. Examine what is causing the interference and correct the situation. EATON CORPORATION www.eaton.com 17

Digitrip Retrofit Kit Installation Components for the General Electric AKRU Series Breaker Step Description Style No. Qty. Comment Step 3 Aux. CT Module 6503C59G 1 Aux. CT Module Assembly Parts 4A35748G04 1 Aux. CT Module Mounting Bracket L. H. 1 Aux. CT Module Mounting Bracket R. H. 1.190-32.375 Screw Flat Head 4.190 Lock Washer Stl. 4.190 Flat Washer Stl. 4.190-32 Nut Hex Stl. 4 Sensor Harness Parts 4A35748G05 1 Sensor Harness 1 Sensor Insulator 3.190-32.375 Screw Fil. 1.190 Flat Washer Stl. 1.190 Lock Washer Stl. 1 Wire Tie Nylon 8 Step 4 Sensor 3 See Pick List Sensor Insulator (From Step 3) 3 Aux. CT Module Mounting Parts 4A35748G06 1.500-13 1.25 Lng. Hex Bolt 2.500 Flat Washer Stl. 4.500 Lock Washer Stl. 2.500-13 Nut Hex Stl. 2 Step 5 Padlock Parts 4A35748G07 1 Padlock Mechanism 1.375 E-clip 1 Step 6 DTA Assembly and Mounting Parts 4A35748G35 1.138-32.375 Screw Lng. Fil. 2.138 Flat Washer Stl. 2.138 Lock Washer Stl. 2.190 Flat Washer Stl. 1.190 Lock Washer Stl. 1.190-32 Nut Hex Stl. 1 Loc-Tite 242 1 Step 7 Breaker Mounted CPT Kit 8259A91G05 1 CPT Only Ring Terminals (.138,.190,.250,.312,.375,.500) 2 Each Size CPT Mounting Parts 4A35748G20 1 CPT Mounting Bracket 1.190-32.500 Lng. Screw Pan Head 6.190-32.375 Lng. Screw Fil. 2 CPT Only.190 Lock Washer Stl. 8.190 Flat Washer Stl. 14.190-32 Nut Hex Stl. 6 Wire Clamp Nylon 1 18 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 Digitrip Retrofit Kit Installation Components for the General Electric AKRU Series Breaker (Continued) Step Description Style No. Qty. Comment Step 8 Aux. Switch Kit 4A35748G02 1 Microswitch 1 Aux. Switch Mounting Bracket 1.138-32 1.00 Lng. Screw Fil. 2.138 Flat Washer Stl. 4 Comm. Only.138 Lock Washer Stl. 2.138-32 Nut Hex Stl. 2.190-32.375 Lng. Screw Fil. 2.190 Flat Washer Stl. 2.190 Lock Washer Stl. 2 Step 9 PT Module Kit 6502C82G01 1.138-32.375 Lng. Screw Fil. 2.138 Flat Washer Stl. 4.138 Lock Washer Stl. 2.138-32 Nut Hex Stl. 2 Comm. Only Ring Terminals (.190,.250,.312,.375,.500) 3 Each Size PT Module Mounting Parts 4A35748G08 1 PT Module Mounting Bracket 1 Glass Poly Insulation Plate 1.190-32.375 Lng. Screw Fil. 2.190 Flat Washer Stl. 4.190 Lock Washer Stl. 2 Comm. Only PT Extension Harness 1 Warning Nameplate 1 Step 10 RMS/R Trip Unit 1 See Pick List Rating Plug 1 See Pick List Trip Unit Mounting Parts 4A35748G09 1 Support Clip L. H. 1 Support Clip R. H. 1 Glass Poly Insulation Plate 1.190-32 4.00 Lng. Screw Fil. 2.190 Flat Washer Stl. 2.190 Lock Washer Stl. 2 Spacer Brass 2.138-32.375 Lng. Screw Fil. 4.138 Flat Washer Stl. 8.138 Lock Washer Stl. 4.138-32 Nut Hex Stl. 4 Digitrip Nameplate 1 Arc Chute Retainer Parts 4A35748G10 1 Arc Chute Retainer Bar 1 Trip Unit Mounting Bracket L. H. 1 Trip Unit Mounting Bracket R. H. 1 EATON CORPORATION www.eaton.com 19

Digitrip Retrofit Kit Installation Components for the General Electric AKRU Series Breaker (Continued) Step Description Style No. Qty. Comment Step 10.250 Flat Washer Stl. 2 (Cont.).250 Lock Washer Stl. 2.250-20 Nut Hex Stl. 2.190-32.500 Lng. Screw Fil. 4.190 Flat Washer Stl. 4.190 Lock Washer Stl. 4 Step 11 External Harness 6502C83G 1 Aux. CT Extension Harness 6502C84G02 1 PT Extension Harness (From Step 8) 1 Comm. Only External Harness Parts 4A35748G11 1.138-32.375 Lng. Screw T.C. 2.138 Flat Washer Stl. 2.138 Lock Washer Stl. 2 Wire Clamps Nylon 2 Wire Clamps Nylon 2 Wire Ties Nylon 10 Step 13 Cell Harness 6503C57G 1 Except 510 Basic Note: Due to the wide vintage of Breakers and the multiple functions of the Retrofit Components, some excess hardware may be left when the Retrofit is complete. 20 EATON CORPORATION www.eaton.com

Instruction Leaflet IL 33-GS8-3 C B A D E F G H I L K J A. Sensors B. Trip Unit C. Aux. CT Module D. Direct Trip Actuator (DTA) E. Aux. Switch M F. Rating Plug G. External Harness H. Aux. CT Harness I. Aux. CPT Module J Cell Terminal Block Assembly K. PT Extension Harness L. PT Module M. Sensor Harness EATON CORPORATION www.eaton.com 21

Table 2. Torque Values for General Mounting and Screw Size Conversion Decimal Size (in) Standard Size Torque (in-lbs) Torque (ft-lbs).112 4.40 10 0.8.138 6.32 18 1.5.164 8.32 36 3.0.190 10.32 46 3.8.250 1/4-20 100 8.3.312 5/16-18 206 17.2.375 3/8-16 356 29.7.438 7/16-14 572 47.7.500 1/2-13 856 71.3 Table 3. Torque Values for Copper BUS Connectors Decimal Size (in) Standard Size Torque (in-lbs) Torque (ft-lbs).250 1/4-20 60 5.312 5/16-18 144 12.375 3/8-16 240 20.500 1/2-13 600 50 22 eaton corporation www.eaton.com

Instruction Leaflet IL 33-GS8-3 Notes: eaton corporation www.eaton.com 23

The instructions for installation, testing, maintenance, or repair herein are provided for the use of the product in general commercial applications and may not be appropriate for use in nuclear applications. Additional instructions may be available upon specific request to replace, amend, or supplement these instructions to qualify them for use with the product in safety-related applications in a nuclear facility. The information, recommendations, descriptions, and safety notations in this document are based on Eaton s experience and judgment with respect to Retrofitting of Power Breakers. This instructional literature is published solely for information purposes and should not be considered all-inclusive. If further information is required, you should consult an authorized Eaton sales representative. The sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between the parties. This literature is not intended to and does not enlarge or add to any such contract. The sole source governing the rights and remedies of any purchaser of this equipment is the contract between the purchaser and Eaton. NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OR WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING THE INFORMATION, RECOMMENDATIONS, AND DESCRIPTIONS CONTAINED HEREIN. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and description contained herein. Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. IL 33-GS8-3 / TBG000380 Part No. IL33-GS8H03 July 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.