ECONOMY CYCLE. Rooftop Packaged Air Conditioners with Economy Cycle. Economy Cycle Rooftop Packaged Air Conditioners

Similar documents
PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Air Cooled Packaged Units

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

UMXCA/UMXCBA ECVA/ECVBA

D M S 760 C01 A A 1 1

Air Cooled Packaged Units Technical Data

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Improves fan ef ciency

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

Landmark Rooftop Packaged Units

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

CWP-CO / CWP-RC / CWP-HP 02 to 35

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Concealed Ducted Split Series R22

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

CHP

PCB COMMERCIAL SERIES

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Ducted Split System Air Conditioners

Ducted Split System Air Conditioners

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

AHN 064 to 304 EHN/CHN 064 to 304

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

technical catalogue tetris KW Chiller and heat pumps air/water

EVD-ice FOR PS SERIES

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Sapphire Horizontal Waterside Control Fan Coil Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DC INVERTER DUCTED AIR CONDITIONERS

Tons BTU/h S.E.E.R* E.E.R** HSPF

TRI-CAPACITY PACKAGE UNIT

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

Si Series Model CE Residential Geothermal Heat Pump

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

GUIDE SPECIFICATIONS. ES Series R-410A

PHR5. Product Specifications

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

SMT-150 Installer Manual

air handling units YAH

A Smarter Breed. of Centrifugal Fans

Air-Cooled Liquid Chiller with integrated hydraulic module

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

VARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls.

ZHA/ZHB SERIES WARNING

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

24% higher part-load efficiency saves running costs.

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

IDENTIFICATION ACCESSORIES DESCRIPTION

ROBICON W120 enclosed drive

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

Tecumseh Semi Hermetic Condensing Units

WATER SOURCE HEAT PUMPS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

V High Efficiency Series

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Prepared By : Checked By : Approved By : Page 1 out of 6

engineering guide Air-Cooled Self-Contained Units

ENR Incorporating

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Section 8. ThermaLoad - Intelligent Load Banks

S/T Ratio. Input BTU/h

DESCRIPTION FEATURES

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Optyma TM Slim Pack Just mount, braze and plug

High Static Fan Coil Units YDFC

Features: Available in horizontal and vertical units

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

INTELEPOWER CX COMMUNICATIONS SYSTEMS

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

N2AE - 50 Hz PRODUCT SPECIFICATIONS

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

Accessories. Series REC

Technical Sales Guide # 040 YDFC 0 1 Page 2

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Transcription:

Economy Cycle Quality Engineering Solutions ECONOMY CYCLE with Economy Cycle www.dunnair.com.au 1

Dunnair Quality Engineering Solutions Dunnair is now firmly positioned as a leading supplier to the air conditioning industry. The name Dunnair is synonymous with high quality products in the commercial air-conditioning industry. Beginning with Dunn Air Conditioning in 1961 and more recently, Dunnair International and Dunnair Australia, the company continues to be a leading importer and supplier of air-conditioning brands for the Australian market. In 1994, the company was bought by Multistack and renamed Dunnair International. In 4, Ernest Ugazio acquired the sales and subsequently state service department of Dunnair. This led to the company being divided into separate entities: Dunnair International and Dunnair Australia, the former focused on Multistack Chiller sales and spare parts; while the latter began design and development of a split ducted and rooftop packaged range that was manufactured in China. The Economy cycle rooftop packaged and split ducted units shown in this brochure are part of Dunnair s range of high quality units for every application. Dunnair has also become the first choice when individual engineering solutions are required. Fast-moving and responsive, Dunnair supplies made-to-measure HVAC solutions to a growing number of high profile developments across Australia. Dunnair research and development plus a strict quality control program have been fundamental to our growth, success and reputation. Dunnair units are manufactured in accordance with strict quality control standards and are MEPS rated and developed for Australian conditions. Range: Dunnair s two modern factories manufacture 16 separate product lines and some 600 different models. Dunnair can supply most products the HVAC industry requires. This new product line of economy cycle is proof that the company is working continuously to improve its product range and the efficiency of its products. Specialised Solutions: Dunnair will engineer and manufacture equipment to suit the application and building design. No challenge will go unaccepted. We will design and make special products as required for the building, mining, transport and maritime industry. We employ mechanical engineers in all sales offices in Australia. Their role is to supporting designers to achieve their goals. Our promise to the system designers is: Tell us what you need and we will work with you to deliver. With a head office in Melbourne, Dunnair has offices in New South Wales, Queensland, South Australia, Western Australia and Tasmania.Dunnair maintains a dedicated engineering and sales support staff waiting to assist you with technical and product information and provide valuable solutions for your project. Dunnair will design, build and deliver HVAC equipment to meet the most stringent specifications and difficult applications. Quality Engineering Solutions 2 www.dunnair.com.au

Economy Cycle Economy Cycle Economy cycle systems are compulsory on larger commercial buildings depending on size and geographical location within Australia. Traditionally, economy cycle systems were designed as a part of rooftop ductwork. This was an expensive and time consuming practice. For over years Dunnair has been a leading innovator of new products and systems in the HVAC industry. The concept of the economy cycle system is not new but it took Dunnair s ingenuity to incorporate this function into one unit. This new range of rooftop packaged air conditioners has been operating in a considerable number of buildings across Australia since 9. These units have made life much easier for building designers, consultants, builders, air conditioning contractors, electricians and most importantly, end users. The obvious benefits are cost savings in both labour and materials. For example, the pairing of the Dunnair Economy Cycle range with the viking module thermostat makes electrical wiring less complicated thereby reducing control installation costs. The Dunnair Economy Cycle Rooftop Packaged range enables a better air conditioning system on all fronts with more fresh air, reduced running costs, less service and maintenance and a much more user friendly control interface. The importance and benefits of installing a self contained Dunnair economy cycle rooftop packaged air conditioner is self-evident when considering what this can deliver: More fresh air to the conditioned space providing a healthier environment. In ideal conditions a saving of up to 70% on running costs. Increased rates due to the carbon tax will be partially offset by using the economy cycle function. The ability to vary the amount of fresh air from 10% to % to achieve maximum benefit from the system. Initial investment will be offset by reduced energy bills over the long term. * Dunnair economy cycle rooftop packaged air conditioners are also designed in split ducted type. There are 47 models in total available in both rooftop packaged and split ducted type. The capacity range starting from 6kW through to kw will satisfy almost any system requirement. Dunnair recommends the economy cycle air conditioner for both domestic and commercial applications in all parts of south and south eastern Australia where in spring and autumn the internal temperature of a building can be maintained with a high proportion of fresh air. * Statement is made based on typical application of Dunnair Economy Cycle air conditioner. Split Ducted Systems available upon request 3

System Working Principle Normal Operation Fresh air motorised 1 Closed Return air motorised 2 Open Relief air motorised 3 Closed Supply air Fan Evaporator coil Condenser coil Supply air flow Return air flow Return air Motorised Damper 2 Axial condenser fans Condenser coil Relief air Motorised Damper 3 Fresh air motorised 1 complete with filter ROOF STRUCTURE Cushion Box Cushion Box nderflashing & enetration by Builder. verflashing by echanical Contractor. Typical) Filter Bank C/W Access Panel PLATFORM Supply Air Roof Top Packaged Unit Fixed to Diffuser Platform C/W Anti Vibration Mounts Supply A Diffuse Internal Insulation 4 www.dunnair.com.au Cushion Box CEILING

Supply Economy Cycle Economy Cycle Mode 1 Fresh air motorised 1 Open Return air motorised 2 Closed Reflief air motorised 3 Closed Economy Cycle Mode 2 Fresh air motorised 1 Open Return air motorised 2 Open Reflief air motorised 3 Open Supply air Fan Evaporator coil Supply air flow Condenser coil Return Return air flow Return air Motorised Damper 2 Axial condenser fans Condenser coil Relief air Motorised Damper 3 Return air Spill Fresh air flow Fresh air motorised 1 complete with filter Underflashing & Penetration by Builder. Overflashing by Mechanical Contractor. (Typical) Filter Bank C/W Access Panel PLATFORM Roof Top Packaged Unit Fixed to Platform C/W Anti Vibration Mounts Internal Insulation Cushion Box CEILING ir r Supply Air Diffuser Return Air Grill 5

Features PHSE 8-PHSE35 single stage PHE40-PHE two stage PHSE8-PHSE35 direct drive PHE40-PHE belt drive Automatic De-Ice Liquid accumulator Crankcase heater 24 volt control Galvanised steel panelling Durable powder coated cabinet (outdoor unit) External stainless steel fittings Easy access panels with turn lock handles, no screws 25mm insulation Coil corrosion protection High quality scroll compressors High/low pressure protection for compressor Time delay protection for compressor Limit start timer Quiet & efficient Individual defrost dual circuit units for two stage units Reverse phase protection Electric reheat high temperature protection (optional) Overload protection for both indoor and outdoor fan motor MEPS IV approved Manufactured for Australian Standards & Conditions High quality control procedures R410a refrigerant is used in our standard units. Units with R407c refrigerant are available on request. Optional Features As an active market player in the commercial air conditioning industry, we understand that every project is unique. Standard manufactured units may not meet the requirements of your system design. Dunnair always welcome enquiries for special custom made air conditioning equipment. Available options are listed below: Split ducted configuration also availbale Two stage availbale for 18-35kW units Fan upgrade (high external static pressure) Stainless steel drip tray Belt drive instead of direct drive fan All copper coils (copper fins) Stainless steel casing VSD on supply air fan Anti-corrosion marine grade black fin Hot gas bypass EC plug fan 2 speed condenser fan High static centrifugal condenser fan for plant room Stainless steel casing Other Customised options available, please contact with your local Dunnair Sale office 6 www.dunnair.com.au

PHSE8-PHE Economy Cycle DUCTED PACKAGED ROOFTOP AIR CONDITIONERS Nomenclature P H S E 25 - B b 2 - R R: R410A ; C: R407c 2: Serial No. b: 415V/3Ph/Hz d: 240V/1Ph/Hz B: 24V control system Nominal cool capacity(kw) E: Economy cycle S: Single System ; None: dual system H: Heat Pump P: Packaged unit Applications These units have been specifically developed for air conditioning in commercial premises, e.g. shopping malls, offices, banks, factories and restaurants. Refrigeration System All PHE units are factory charged with R410A refrigerant. Compressor Our high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. Safety Features 1. High and low pressure protection 2. Indoor and outdoor fan overload protection 3. Compressor delay timer 4. Circuit breakers 5. Time and temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle 6. Integrated fault run terminal 7. Crankcase heaters 7

Optional Controller Features Up to 4 stage compressor control. Integrated communications (Modbus & BACnet). Integrated Economy function. 365 day, 7 day or manual operation. Security PIN protected menus. Smart 2 wire sensors with multiple functions. - Averaging - After Hours run function - Force system Off - Force ventilation (fan only) mode Specifications Input Voltage Operating Temperature Operating RH Storage Temperature Size Optional RF & communicating sensors available. 2 programmable auxiliary inputs. 0-10V heating & cooling valve control. Occupancy Inputs with individual set point control. 24V or 240V AC powered. Volt free relay outputs - 240V 10A max. 24/240 VAC+ / -15%. /60 Htz 0-C (32 to 122F) 0-95% (non condensing) 0-65C (32 to F) 110 x 110 x 65mm 110 x 110 x 65mm with terminal covers fitted Control range Maximum Equipment Stages Anti-cycle timer After hours timer Memory type clock Backup battery life Holiday events LCD Relays 0-10V output Room & outside air sensor communicating sensor Optional RF sensor Communications 0-C 4 compressors (HC made = 2 heat 3 cool) Off, 2,3,4 or 5 minutes (installer adjustable) Off to 12 hours (installer adjustable) Non volatile 128k 12/24 hour 7 days with calendar Backup battery for clock (CR1220) 5 to 8 years 10 - (Perpetual and / or self expiring) 32 x132 graphical - led back light Fan 10A 240v Max - volt free All others 5A 240Vac Max - volt free 10mA max each 10K NTC type II (2 wire screened) 3 wire - 400m maximum with control function 10K NTC type II/ RH 10-98% RH 2% 2 X AAA batteries 10mth life 10K NTC type II Range - m open air (40M indoors typical) Frequency 433Mhz - 2 way with error checking Modbus RTU Baud rate 4.8 /9.6/ 19.2K BACnet MS-TP Baud rate 4.8 / 9.6 / 19.2K Address range 1-255 8 www.dunnair.com.au

Specifications Economy Cycle Models PHSE8 PHE Model Total Cooling Capacity (Kw) Sensible Cooling Capacity (kw) Heating Capacity (Kw) Nominal Air Flow (L/s) Phase Nominal Max Current Noise Level (dba) Refrigerant Circuits Fan Drive PHSE8 8.0 7.2 7.9 472 1 15.9 66.8 1 Direct PHSE10 9.3 8.0 9.4 555 1 26.0 67.2 1 Direct PHSE12 11.5 9.7 11.7 695 3 11.0 69.7 1 Direct PHSE15 14.8 13.0 14.6 8 3 12.6 70.6 1 Direct PHSE18 17.1 14.4 17.5 0 3 14.6 70.4 1 Direct PHSE20 20.5 16.3 20.7 1110 3 17.4 73.5 1 Direct PHSE25 23.8 19.1 24.2 1390 3 22.4 74.9 1 Direct PHSE30 30.6 24.9 30.6 1800 3 27.0 74.7 1 Direct PHSE35 34.8 28.3 34.2 0 3 28.7 75.2 1 Direct PHE40 39.1 31.5 38.4 2 3 30.8 68.2 2 Belt PHE45 44.6 36.4 44.2 2700 3 37.2 70.3 2 Belt PHE 48.6 39.4 47.8 2800 3 41.2 71.3 2 Belt PHE56 55.1 44.5 55.6 0 3 47.7 72.3 2 Belt PHE66 65.5.9 60.7 30 3 54.5 71.2 2 Belt PHE73 72.8 59.3 66.6 3900 3 60.6 73.0 2 Belt PHE80 80.4 65.5 80.7 4 3 66.2 75.8 2 Belt PHE85 86.6 68.2 87.1 40 3 63.2 75.8 2 Belt PHE90 88.5 71.0 85.0 4800 3 74.4 73.6 2 Belt PHE95 95.8 72.3 96.2 5 3 74.4 76.0 2 Belt PHE 102.2 82.9 98.5 50 3 85.2 77.0 2 Belt PHE120 117.6 95.2 116.2 60 3 98.8 76.0 2 Belt PHE140 137.8 110.6 132.0 70 3 117.5 80.2 2 Belt PHE160 156.2 127.5 152.5 80 3 133.9 77.6 2 Belt PHE180 176.8 143.6 169.4 90 3 153.2 80.8 2 Belt PHE 201.8 164.3 196.2 100 3 163.7 83.2 2 Belt Cooling Capacity is based on 27 C DB, 19 C WB Entering Air Temperature & 35 C Ambient Temperature Heating Capacity is based on 21 C DB, Entering Air Temperature Sound Levels are from 1 metre of the outdoor unit 9

Dimensions Models PHSE8 PHE Overall size (mm) Spigot Sizes (mm) Damper Sizes (mm) Model Width Depth Height Weight (kg) Return Air spigot (WxH) Supply Air spigot (WxH) Fresh Air Damper (WxH) Return Air Damper (WxH) Relief Air Damper (WxH) Number of axial condenser fans PHSE8 10 1704 800 268 320x6 270x180 x0 x0 x0 1 PHSE10 10 1704 800 268 320x6 270x180 x0 x0 x0 1 PHSE12 10 1704 865 320x6 x221 x0 x0 x0 1 PHSE15 1290 0 865 332 400x700 282x237 320x600 320x600 320x600 1 PHSE18 1290 0 865 340 400x700 363x275 320x600 320x600 320x600 1 PHSE20 1400 0 8 448 760x400 325x338 320x600 320x600 320x600 1 PHSE25 1600 2 1020 520 600x700 325x331 400x600 400x600 400x600 1 PHSE30 1800 23 1010 618 700x800 455x331 400x800 400x800 400x800 2 PHSE35 1800 23 1010 625 700x800 455x331 400x800 400x800 400x800 2 PHE40 18 24 1345 670 7x1 7x7 400x0 0x800 400x0 2 PHE45 18 2660 1345 680 7x1 7x7 400x0 0x800 400x0 2 PHE 1900 3010 14 810 7x1 7x7 400x1 400x1 0x0 4 PHE56 1900 3010 14 825 7x1 7x7 400x1 400x1 0x0 4 PHE66 2 3320 15 915 875x1400 569x569 0x1 600x1 0x1 4 PHE73 2130 3320 15 940 875x1400 569x596 0x1 600x1 0x1 4 PHE80 2130 3320 15 990 875x1400 571x496 0x1 600x1 0x1 4 PHE85 2130 3420 15 990 875x1400 569x569 0x1 600x1 0x1 4 PHE90 2130 3400 18 1060 800x1695 638x638 0x0 600x1 0x0 4 PHE95 2130 3400 18 1060 800x1695 638x638 0x0 600x1 0x0 4 PHE 2130 3710 18 1 800x1695 638x638 600x0 600x0 600x0 4 PHE120 2130 4010 19 1240 800x1695 638x638 700x1600 700x1600 700x1600 4 PHE140 20 5700 19 2140 1800x17 715x715 800x16 0x0 800x16 4 PHE160 20 5800 0 2180 1800x17 800x800 900x16 0x0 900x16 4 PHE180 2 6 23 2480 1900x2 900x900 900x1800 10x18 900x1800 4 PHE 2 6 23 2520 1900x2 900x900 900x1800 10x18 900x1800 4 10 www.dunnair.com.au

Diagrams Models PHSE8 PHE120 Depth Economy Cycle Width RETURN AIR SUPPLY AIR Height SIDE ELEVATION SUPPLY & RETURN VIEW SUPPLY AIR PLAN VIEW RETURN AIR Relief Air FRESH AIR Models PHE140 PHE Depth SUPPLY AIR Access Panel Access Panel Height FRESH AIR SIDE ELEVATION Width SUPPLY & RETURN VIEW RETURN AIR PLAN VIEW Relief Air 11

Fan Curves Air Handling Performance PHSE8 PHSE10 400 440 480 520 560 480 520 560 600 640 PHSE12 PHSE15 0 600 700 800 900 630 730 830 930 1030 PHSE18 PHSE20 800 900 0 1 1 710 910 1110 1310 1510 12 www.dunnair.com.au

Fan Curves Economy Cycle Air Handling Performance PHSE25 PHSE30 990 1190 1390 1590 1790 1400 1600 1800 0 2 PHSE35 PHE40 400 3 2.2 kw Motor Limit 1600 1800 0 2 2400 1600 1800 0 2 2400 2600 2800 PHE45 400 3 2.2 kw Motor Limit PHE 400 3 3.0kW Motor Limit 2 2 0 2700 2900 3 3 2 2400 2600 2800 0 3 3400 13

Fan Curves Air Handling Performance PHE56 400 3 3.0kW Motor Limit 2400 2600 2800 0 3 3400 3600 PHE66 400 3 3.0kW Motor Limit 2800 0 3 3400 3600 3800 4000 4 4400 PHE73 400 3 4.0kW Motor Limit PHE80 400 3 5.5kW Motor Limit 3 30 3700 3900 4 4 40 4700 30 3700 3900 4 4 40 4700 4900 5 PHE85 400 3 3700 3900 4 4 40 4700 4900 5 5 5.5 kw Motor Limit PHE90 400 3 3800 4000 4 4400 4600 4800 00 5 5400 5600 5800 5.5kW Motor Limit 14 www.dunnair.com.au

Fan Curves Air Handling Performance Economy Cycle PH95 400 3 7.5kW Motor Limit 4 4400 4600 4800 00 5 5400 5600 5800 6000 6 PH 400 3 7.5kW Motor Limit 4400 4675 49 5225 50 5775 60 6325 6600 PH120 400 3 5 5325 58 6175 60 6825 7 74755 7800 7.5kW Motor Limit PH140 400 3 30 40 50 60 70 80 90 100 10 11kW Motor Limit PH160 PH180 0 400 3 40 50 60 70 80 90 100 10 10 11kW Motor Limit 400 3 50 60 70 80 90 100 10 10 130 11kW Motor Limit PH 400 3 15kW Motor Limit 60 70 80 90 100 10 10 130 140 15

Sound Pressure Curves PHSE8 A Class: 66.8dB* Frequency (Hz) Decibel (db) 64 79.3 125 75.0 69.0 0 64.0 0 62.2 0 57.6 4000 51.0 8000 43.6 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHSE10 A Class: 67.2dB* Frequency (Hz) Decibel (db) 64 76.5 125 72.3 69.6 0 66.1 0 62.6 0 53.1 4000 48.6 8000 41.8 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHSE12 A Class: 69.7dB* Frequency (Hz) Decibel (db) 64 76.8 125 71.5 69.8 0 70.5 0 70.6 0 64.8 4000 58.0 8000 49.3 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 16 www.dunnair.com.au

Sound Pressure Curves Economy Cycle PHSE15 A Class: 70.6dB* Frequency (Hz) Decibel (db) 64 76.5 125 72.9 68.9 0 67.0 0 66.7 0 60.9 4000 55.3 8000 48.0 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHSE18 A Class: 70.4dB* Frequency (Hz) Decibel (db) 64 77.3 125 72.1 69.0 0 66.2 0 65.9 0 61.1 4000 55.5 8000 47.2 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHSE20 A Class: 73.5dB* Frequency (Hz) Decibel (db) 64 77.3 125 74.0 72.8 0 73.1 0 72.5 0 69.3 4000 59.2 8000 49.3 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 17

Sound Pressure Curves PHSE25 A Class: 74.9dB* Frequency (Hz) Decibel (db) 64 78.1 125 74.0 73.8 0 73.1 0 71.5 0 69.3 4000 58.7 8000 51.9 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHSE30 A Class: 74.7dB* Frequency (Hz) Decibel (db) 64 77.2 125 71.8 71.5 0 72.4 0 71.0 0 65.6 4000 59.7 8000 49.8 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHSE35 A Class: 75.2dB* Frequency (Hz) Decibel (db) 64 79.5 125 77.2 76.1 0 72.6 0 70.8 0 64.8 4000 58.3 8000 52.9 10dB 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 18 www.dunnair.com.au

Sound Pressure Curves Economy Cycle PHE40 A Class: 68.2dB* Frequency (Hz) Decibel (db) 90dB 64 42 125 58 56 0 61 0 64 0 62 4000 60 8000 54 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE45 Frequency (Hz) A Class: 70.3dB* Decibel (db) 64 43 90dB 125 58 57 0 63 0 66 0 64 4000 62 8000 56 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE Frequency (Hz) A Class: 71.3dB* Decibel (db) 64 44 90dB 125 59 58 0 64 0 67 0 65 4000 63 8000 57 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 19

Sound Pressure Curves PHE56 Frequency (Hz) A Class: 72.3dB* Decibel (db) 64 44 125 59 90dB 58 0 65 0 68 0 66 4000 64 8000 58 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE66 Frequency (Hz) A Class: 71.2dB* Decibel (db) 64 45 125 56 59 90dB 0 68 0 65 0 65 4000 63 8000 56 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE73 Frequency (Hz) A Class: 73.0dB* Decibel (db) 64 46 125 57 90dB 60 0 69 0 67 0 67 4000 65 8000 58 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 20 www.dunnair.com.au

Sound Pressure Curves Economy Cycle PHE80 Frequency (Hz) A Class: 75.8dB* Decibel (db) 64 47 125 59 90dB 62 0 71 0 70 0 70 4000 68 8000 61 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE85 Frequency (Hz) A Class: 75.8dB* Decibel (db) 64 48 125 60 90dB 63 0 72 0 71 0 72 4000 69 8000 62 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE90 Frequency (Hz) A Class: 73.6dB* Decibel (db) 64 46 125 58 90dB 60 0 70 0 67 0 68 4000 65 8000 58 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 21

Sound Pressure Curves PHE95 Frequency (Hz) A Class: 76.0dB* Decibel (db) 64 48 125 59 90dB 62 0 72 0 70 0 70 4000 68 8000 61 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE Frequency (Hz) A Class: 77.0dB* Decibel (db) 64 125 61 90dB 64 0 73 0 71 0 71 4000 69 8000 62 PHE120 Frequency (Hz) A Class: 76.0dB* Decibel (db) 64 49 125 61 90dB 63 0 72 0 70 0 70 4000 68 8000 61 *Occupant at least 1.0m from sound source. 22 www.dunnair.com.au

Sound Pressure Curves Economy Cycle PHE140 Frequency (Hz) A Class: 80.2dB* Decibel (db) 64 51 125 63 66 90dB 0 75 0 74 0 75 4000 72 8000 65 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE160 Frequency (Hz) A Class: 77.6dB* Decibel (db) 64 51 125 62 90dB 64 0 74 0 71 0 72 4000 69 8000 62 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz PHE180 Frequency (Hz) A Class: 80.8dB* Decibel (db) 64 52 125 64 90dB 67 0 76 0 75 0 75 4000 73 8000 66 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 23

Sound Pressure Curves PHE Frequency (Hz) A Class: 83.2dB* Decibel (db) 64 53 125 66 90dB 68 0 78 0 77 0 78 4000 75 8000 68 125Hz Hz 0Hz 0Hz 0Hz 4000Hz 8000Hz *Occupant at least 1.0m from sound source. 24 www.dunnair.com.au

Wiring Diagrams Economy Cycle PHSE8-10 Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-2 KM1-3 FR TR PU1/2/3 DF1 VAR KT1 PRF KA1 Motor Overload Breaker Contactor Thermal Relay Transformer Fuse De ice Varistor Time Relay Phase protection Fault Relay RC1-3 RV1 TK1 TK2 L/HP1 CM1 FM1 EM SH1 BR1 Filter Reversing valve Overload protector Disch. temp. sensor HP/LP switch Compressor Condenser fan Evaporator fan Sump heater Bypass Relay 25

Wiring Diagrams PHSE12-35 Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-2 KM1-3 FR TR PU1/2/3 DF1 VAR KT1 PRF KA1 Motor Overload Breaker Contactor Thermal Relay Transformer Fuse De ice Varistor Time Relay Phase protection Fault Relay RC1-3 RV1 TK1 L/HP1 CM1 FM1 EM SH1 BR1 Filter Reversing valve Overload protector HP/LP switch Compressor Condenser fan Evaporator fan Sump heater Bypass Relay 26 www.dunnair.com.au

Wiring Diagrams Economy Cycle PHSE25-35 Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-2 KM1-3 FR TR PU1/2/3 DF1 VAR KT1 PRF KA1 Motor Overload Breaker Contactor Thermal Relay Transformer Fuse De ice Varistor Time Relay Phase protection Fault Relay RC1-3 RV1 TK1 TK2 L/HP1 CM1 FM1 EM SH1 BR1 Filter Reversing valve Overload protector Disch. temp. sensor HP/LP switch Compressor Condenser fan Evaporator fan Sump heater Bypass Relay 27

Wiring Diagrams PHE40-66 Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-3 Motor Overload Breaker KM1-5 Contactor FR Thermal Relay TR Transformer PU1/2/3 Fuse DF1/DF2 De ice VAR Varistor KT1-2 Time Relay PRF Phase protection KA1-2 Fault Relay RC1-5 Filter RV1/RV2 Reversing valve TK1-2 Overload protector L/HP1-2 HP/LP switch CM1/CM2 Compressor FM1/FM2 Condenser fan EM Evaporator fan SH1-2 Sump heater BR1-2 Bypass Relay 28 www.dunnair.com.au

Wiring Diagrams Economy Cycle PHE73-90 Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-3 Motor Overload Breaker KM1-5 Contactor FR Thermal Relay TR Transformer PU1/2/3 Fuse DF1/DF2 De ice VAR Varistor KT1-2 Time Relay PRF Phase protection KA1-2 Intermediate relay KA3-4 Fault Relay RC1-5 Filter RV1/RV2 Reversing valve TK1-4 Overload protector TK5-6 Disch. temp. protector L/HP1-2 HP/LP switch CM1/CM2 Compressor FM1/FM2 Condenser fan EM Evaporator fan SH1 Sump heater BR1 Bypass Relay 29

Wiring Diagrams PHE-140 Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-3 Motor Overload Breaker KM1-5 Contactor FR Thermal Relay TR Transformer PU1/2/3 Fuse DF1/DF2 De ice VAR Varistor KT1-2 Time Relay PRF Phase protection KA1-2 Intermediate relay KA3-4 Fault Relay RC1-5 Filter RV1/RV2 Reversing valve TK1-4 Overload protector TK5 Compressor protect L/HP1-2 HP/LP switch CM1/CM2 Compressor FM1/FM2 Condenser fan EM Evaporator fan SH1 Sump heater BR1 Bypass Relay 30 www.dunnair.com.au

Wiring Diagrams Economy Cycle PHE160- Y1 T 12 Y1 T 12 Y1 T 12 3 2 1 Exhaust air 3 2 1 Return air 3 2 1 Fresh air QF1-3 Motor Overload Breaker KM1-7 Contactor FR1-3 Thermal Relay TR Transformer PU1/2/3 Fuse DF1/DF2 De ice VAR Varistor KT1-2 Time Relay PRF Phase protection KA1-2 Intermediate relay KA3-4 Fault Relay RC1-7 Filter RV1/RV2 Reversing valve TK1-4 Overload protector TK5-6 Disch. temp. sensor L/HP1-2 HP/LP switch CM1/CM2 Compressor FM1-4 Condenser fan EM Evaporator fan SH1-2 Sump heater BR1-2 Bypass Relay 31

Quality Engineering Solutions DUNNAIR (Aust) Pty Ltd Head Office: 140 Bernard Street, Cheltenham VIC 3192 p 03 8586 8 f 03 8586 8201 e salesaust@dunnair.com.au w www.dunnair.com.au Dunnair New South Wales: p 02 9674 1577 f 02 9674 1588 e salesnsw@dunnair.com.au Dunnair SA & NT: p 08 8240 2888 f 08 8240 2777 e salessa@dunnair.com.au Dunnair Western Australia: p 08 9418 2444 f 08 9418 2 e saleswa@dunnair.com.au Dunnair Victoria: p 03 9558 7001 f 03 9551 1644 e salesvic@dunnair.com.au Dunnair Queensland: p 07 3890 8796 f 07 3890 8642 e salesqld@dunnair.com.au Dunnair Tasmania: p 0418 756 643 f 03 6425 3531 e salestas@dunnair.com.au New Zealand (agent): p +64 9 582 1012 e salesnz@dunnair.com.au DUNNAIR OVERSEAS REPRESENTING OFFICES New Zealand (agent): P: +64 9 582 1012 E: salesnz@dunnair.com.au Contact: Mr Rob Morgan Shanghai: P: +86 158 8806 3726 E: salesshh-china@dunnair.com.au Contact: Ms Shelly Xiong Hong Kong: P: +852 2575 7080 E: saleshk@dunnair.com.au Contact: Ms Fanny Leung Thailand: P: +66 8 7074 2965 E: salesth@dunnair.com.au Contact: Mr Giuseppe Di Martino Guangzhou: P: +86 139 0238 2104 E: salesgz-china@dunnair.com.au Contact: Mr Jeff He Singapore: Add: 240 Macpherson Road,#05-04/05, Pines Industrial Building Singapore 348574 E: salessg@dunnair.com.au Contact: Mr Derek Wong Dunnair (Aust) Pty Ltd supports a policy of continuous product improvement. Therefore specification and designs are subject to change without prior notice. Dunnair (Aust) Pty Ltd accepts no responsibility for possible errors in catalogues, brochures and other printed material. www.dunnair.com.au