Z-Series Rooftop Units 60 HZ

Similar documents
Z-Series Rooftop Units 60 HZ

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw

Z-Series Rooftop Units 60 HZ

ZHA/ZHB SERIES WARNING

Z-Series Rooftop Units 50 HZ

ASHRAE 90.1 COMPLIANT

ASHRAE 90.1 COMPLIANT

Landmark Rooftop Units 50 HZ

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C

FEATURES AND BENEFITS

CHP

K-Series Rooftop Units Standard and High Efficiency - 60 HZ

Z-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

Landmark Rooftop Units 50 HZ

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013)

K-Series Rooftop Units 50 HZ

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

K-Series Rooftop Units 50 HZ

ELITE SERIES R-410A Ready - Multi-Position

Landmark Rooftop Units 50 HZ

K-Series Rooftop Units Standard and High Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

T CLASS ROOFTOP UNITS 60 HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

K-Series Rooftop Units 60 HZ

Packaged L Series LCA/LGA/LHA

VHIA High-Static Ducted Indoor Units - 60HZ

Landmark Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

K-Series Rooftop Units 60 HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Landmark Rooftop Packaged Units

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

K-Series Rooftop Units Standard and High Efficiency - 60 HZ

13 GCS X A X Nominal SEER Minor Revision Number

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

PRAC14 PRODUCT SPECIFICATIONS

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

Factory Option Codes L M E S P R D V F F H E

GR4GA Series Single Packaged Gas/Electric Units

K-Series Rooftop Units 50 HZ

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Landmark Rooftop Units Standard and High Efficiency - 60 HZ

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Landmark Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS

Tons BTU/h S.E.E.R* E.E.R** HSPF

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

GR4GC Series Single Packaged Gas/Electric Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Landmark Rooftop Units 50 HZ

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

K-Series Rooftop Units Dual-Fuel - High Efficiency - 60 HZ

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

S/T Ratio. Input BTU/h

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS

ENERGY RECOVERY SYSTEM 60 HZ

Packaged L Series LCA/LGA/LHA

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Packaged L Series LCA/LCC GUK

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

K-Series Rooftop Units 50 HZ

Typical Applications. Horizontal Installation

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Transcription:

PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZC Z-Series Rooftop Units 60 HZ Bulletin No. ZCA-06-060 (0/0) MODEL NUMBER IDENTIFICATION to 5 Tons Net Cooling Capacity 4,600 to 57,000 Btuh Optional Electric Heat - 5 to.5 kw Z C A 060 S 4 B N Y ASHRAE 90. COMPLIANT Brand/Family Z = Z-Series Unit Type C = Packaged Electric Cooling w/ optional Electric Heat Voltage P = 08/0V phase-60hz Y = 08/0V- phase-60hz G = 460V- phase-60hz J = 575V- phase-60hz Major Design Sequence A = st Generation B = nd Generation Nominal Cooling Capacity - Tons 06 = Tons 048 = 4 Tons 060 = 5 Tons Cooling Efficiency S = Standard Efficiency Minor Design Sequence = st Revision = nd Revision = rd Revision Factory Installed Electric Heat N = No Heat Refrigerant Type 4 = R-40A Blower Type B = Belt Drive

FEATURES AND BENEFITS E D I G B C H F Z-Series rooftop units from Allied are the new standard for cost efficient, reliable rooftop units built for long-lasting performance that can significantly improve indoor environments. Z-Series rooftop units feature: Quick and Easy Retrofit - Fast installation for replacement of many existing rooftop units - fits high volume competitor s roof curbs R-40A Refrigerant - Environmentally friendly Scroll Compressors - Single speed scroll compressor is furnished on all models. Eco-last Coil System - Smaller, lighter condenser coil. High Pressure Switch - Protects compressor. Belt Drive Blower Motor - To maximize air performance. Downflow or Horizontal Airflow - Easy field conversion. Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Drain Pan - Provides application flexibility, durability, improved serviceability and meets ASHRAE 6. requirements for drain pan slope. Z-Series Packaged Electric / Electric to 5 Tons / Page

FEATURES AND BENEFITS Contents Accessory Dimensions........................... Blower Data................................ Dimensions................................. Electrical Data............................... 5 Electric Heat Capacities..........................8 Features And Benefits........................... Model Number Identification........................ Options / Accessories............................ 7 Outdoor Sound Data............................0 Ratings...................................0 Specifications................................ 9 Unit Clearances.............................. 9 Weight Data................................ APPROVALS AHRI Certified to AHRI Standard 0/40-008. CSA listed. Units are Certified by CSA. Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. All models are ASHRAE 90. compliant. ISO 900 Registered Manufacturing Quality System. WARRANTY Limited five years on compressors. Limited three years on the Eco-last Coil System. Limited one year all other covered components. B COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 5 F to 5 F without any additional controls. R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit is factory pre-charged with refrigerant. See Specifications Table. Compressor Resiliently mounted on rubber grommets for quiet operation. Scroll compressors for high performance, reliability and quiet operation. High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Filter/Drier High capacity filter/drier protects the system from dirt and moisture. C D Eco-last Coil System Condenser coil features lightweight, all aluminum brazed fin construction. Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tube and two refrigerant manifolds. Eco-last Coil System Features: Improved heat transfer performance due to high primary surface area (flat tubes) versus secondary surface (fins). Smaller internal volume (reduced refrigerant charge). High durability (all aluminum construction). Fewer brazed joints. Compact design (reduces unit weight). Easy maintenance/cleaning. Mounting brackets with rubber inserts secure coil to unit providing vibration dampening and corrosion protection Evaporator Coil Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity. Condensate Drain Pan Plastic pan, sloped to meet drainage requirements of ASHRAE 6.. End drain connection. Outdoor Coil Fan Motor Thermal overload protected, totally enclosed, permanently lubricated bearings, shaft down, fan guard mount. Outdoor Coil Fan Guard PVC coated fan guard furnished. Z-Series Packaged Electric / Electric to 5 Tons/ Page

FEATURES AND BENEFITS COOLING SYSTEM (CONTINUED) REQUIRED SELECTIONS Cooling Capacity Specify nominal cooling capacity of the unit. OPTIONS/ACCESSORIES Field Installed Condensate Drain Trap Field installed only. Available in copper or PVC. Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation. Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. Low Ambient Kit Cycles the outdoor fan while allowing compressor operation in the cooling cycle. This intermittent fan operation allows the system to operate without icing the evaporator coil and losing capacity. Designed for use in ambient temperatures no lower than 0 F. A crankcase heater must be installed on the compressor. E F G H CABINET Construction Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have fork slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Air-Flow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal air flow configuration without the need of a kit. Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs. Optional Bottom Power Entry Kit is available. Exterior Panels Constructed of heavy-gauge, galvanized steel with a two-layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation. Access Panels Access panels are provided for the compressor, heating, controls, blower and air filter/economizer section. OPTIONS/ACCESSORIES Factory Installed Corrosion Protection A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E-Coat) Meets Mil Spec MIL-P-5084, ASTM B7 Standard Method Salt Spray Testing. Indoor Corrosion Protection: - Coated coil Outdoor Corrosion Protection: - Coated coil Field Installed Coil/Hail Guards Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coil from damage on all three sides of cabinet. Z-Series Packaged Electric / Electric to 5 Tons / Page 4

FEATURES AND BENEFITS CONTROLS Unit Control All control voltage is provided via a 4V (secondary) transformer with inline fuse protection. Heat/Cool Staging - Capable of up to heat / cool staging with a thermostat. Night Setback Mode - Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only. Smoke Detectors NOTE - Smoke detectors are not available and must be field provided by installer. I BLOWER A wide selection of supply air blower options are available to meet a variety of air flow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered on all models and are available in several different sizes to maximize air performance. Supply Air Blower Forward curved blades, blower wheel is statically and dynamically balanced. Equipped with ball bearings and adjustable pulley (allows speed change),. REQUIRED SELECTIONS Supply Air Blower Order blower motor horsepower and drive kit number required when base unit is ordered, see Drive Kit Specifications Table. INDOOR AIR QUALITY Air Filters Disposable inch filters furnished as standard. OPTIONS/ACCESSORIES Field Installed Indoor Air Quality (CO ) Sensor Monitors CO levels adjusts economizer dampers as needed for Demand Control Ventilation. ELECTRICAL REQUIRED SELECTIONS Voltage Choice Specify when ordering base unit. Field Installed Electric Heat Helix wound nichrome elements, individual element limit controls, wiring harness. See Options / Accessories tables for ordering information. Unit Fuse Block must be ordered extra. See Electrical/Electric Heat tables for ordering information. SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Marked & Color-Coded Wiring All electrical wiring is color-coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Blower Access Supply air blower parts are located near the access door for easy servicing and adjustment. Coil Cleaning Condenser coil allows easy cleaning. Compressor Compartment Compressor is located near the perimeter of the unit in the outdoor compartment for easier access. Hinged service panel in the condenser section allows system operation checks to be done without changing the air flow across the outdoor coils. Z-Series Packaged Electric / Electric to 5 Tons/ Page 5

OPTIONS / ACCESSORIES ECONOMIZER/OUTDOOR AIR/EXHAUST OPTIONS Factory or Field Installed Economizer Downflow (Factory Installed) Downflow or Horizontal (Field Installed) Gear-driven action return air and outdoor air dampers, plugin connections to unit, nylon bearings, neoprene seals, 4-volt, fully-modulating spring return motor, adjustable minimum damper position. Outdoor Air Hood is furnished. Economizer includes Barometric Relief Dampers with Exhaust Hood. Barometric Relief Dampers allow relief of excess air, aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Single Sensible Temperature Control is furnished with the economizer Outdoor air sensor enables Economizer if the outdoor temperature is less than the setpoint of the control. Outdoor Air Dampers - Downflow Linked mechanical dampers, 0 to 5% (fixed) outdoor air adjustable, installs in unit. Automatic model features fully modulating spring return damper motor with plug-in connection. Manual model features a slide damper. Maximum mixed air temperature in cooling mode: 00 F. Outdoor Air Hood is furnished. Fan - Downflow or Horizontal Installs external to unit for applications with Economizer option. Provides exhaust air pressure relief. Interlocked to run when supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected. Fan is in. diameter with 5 fan blades. / hp motor. CEILING DIFFUSERS Ceiling Diffusers (Flush and Step-Down) Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) NOTE - Ceiling Diffuser Transitions are not furnished and must be field fabricated. ROOF CURB Roof Curb, Downflow Full perimeter. Insulated filler panels are furnished for installation under the outdoor section of the rooftop unit. See dimension drawings. Nailer strip furnished, mates to unit, US National Roofing Contractors Approved, shipped knocked down. Available in 8, 4, 8, and 4 inch heights. Clip Curbs use interlocking tabs to fasten together. No tools required. Standard roof curb corners fasten together with furnished hardware. Z-Series Packaged Electric / Electric to 5 Tons / Page 6

OPTIONS / ACCESSORIES Item Catalog No. 06 048 060 COOLING SYSTEM Condensate Drain Trap PVC - CTRAP0AD 76W6 X X X Copper - CTRAP0AD 76W7 X X X Compressor Crankcase Heater 08/0V- or ph - ZCCHT0A-P 99W6 X 08/0V- or ph - ZCCHTA-P 99W64 X X 460V - ph - ZCCHT0A-G 99W6 X 460V - ph - ZCCHTA-G 99W65 X X 575V - ph - ZCCHT0A-J 99W6 X 575V - ph - ZCCHTA-J 99W66 X X Drain Pan Overflow Switch ZSNSR90A 99W59 X X X Low Ambient Kit ZSNSRA- 99W67 X X X Blower - SUPPLY AIR Motors Belt Drive - hp Standard Efficiency Factory O O O Belt Drive -.5 hp Standard Efficiency Factory O O O Drive Kits See Blower Data Tables for selection Kit #Z0-678-05 rpm Factory O Kit #Z0-80-6 rpm Factory O Kit #Z0-906-8 rpm Factory O Kit #Z04-964-47 rpm Factory O Kit #Z05-098-490 rpm Factory O Kit #Z06-6-64 rpm Factory O CABINET Coil/Hail Guards ZGARD0A- 97W5 X X X Corrosion Protection Factory O O O ELECTRICAL Voltage 60 hz 08/0V - phase Factory O O O 08/0V - phase Factory O O O 460V - phase Factory O O O 575V - phase Factory O O O Bottom Power Entry Kit ZPEKT0A- 98W08 X X X ELECTRIC HEAT 5 kw 08/0V-ph - ZEH0050ANP 98W96 X X X 08/0V-ph - ZEH0050ANY 99W0 X X X 460V-ph - ZEH0050ANG 99W06 X X X 575V-ph - ZEH0050ANJ 99W X X X 7.5 kw 08/0V-ph - ZEH0075ANP 98W97 X X X 08/0V-ph - ZEH0075ANY 99W0 X X X 460V-ph - ZEH0075ANG 99W07 X X X 575V-ph - ZEH0075ANJ 99W X X X 0 kw 08/0V-ph - ZEH000ANP 98W98 X X X 08/0V-ph - ZEH000ANY 99W0 X X X 460V-ph - ZEH000ANG 99W08 X X X 575V-ph - ZEH000ANJ 99W X X X 5 kw 08/0V-ph - ZEH050ANP 98W99 X X X 08/0V-ph - ZEH050ANY 99W04 X X X 460V-ph - ZEH050ANG 99W09 X X X 575V-ph - ZEH050ANJ 99W4 X X X.5 kw 08/0V-ph - ZEH05ANP 99W00 X X 08/0V-ph - ZEH05ANY 99W05 X X 460V-ph - ZEH05ANG 99W0 X X 575V-ph - ZEH05ANJ 99W5 X X ELECTRIC HEAT ACCESSORIES Unit Fuse Block - See Electrical/Electric Heat Tables for Selection X X X hp blower motor is not available for 08/0V-ph applications..5 hp motor is required with Z05 and Z06 drive kits. NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. OX - Field Installed or Configure to Order (factory installed) O - Configure to Order (Factory Installed) X - Field Installed. Z-Series Packaged Electric / Electric to 5 Tons/ Page 7

OPTIONS / ACCESSORIES Item ECONOMIZER Catalog No. 06 048 060 Economizer - With Barometric Relief Dampers and Exhaust Hood (Downflow) ZECON0A- 98W09 OX OX OX Economizer - With Barometric Relief Dampers and Exhaust Hood (Horizontal) ZECON6A- 98W68 X X X Economizer Controls Single Enthalpy Control CSNSR64FF 5W64 X X X OUTDOOR AIR Outdoor Air Dampers - Includes Outdoor Air Hood Motorized ZDAMPA- 95W74 X X X Manual ZDAMPA- 95W7 X X X Power EXhaust FAN Standard Static (Downflow) 08/0V- or ph - ZPWRE0A-P E0 X X X 460V-ph - ZPWRE0A-G E0 X X X Standard Static (Horizontal) 08/0V- or ph - ZPWRE5A-P 4E0 X X X 460V-ph - ZPWRE5A-G 8E0 X X X 575V Transformer Kit 575V-ph - ZTRFM0A-J 59E0 X X X NOTE - Order 575V Transformer Kit with 08/0V Fan for 575V applications. Indoor Air Quality Indoor Air Quality (Co ) Sensors Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AEL 77N9 X X X Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting C0SNSR5AEL 87N54 X X X CO Sensor Duct Mounting Kit - for downflow applications C0MISC9AE 85L4 X X X Aspiration Box - for duct mounting non-plenum rated CO sensor (77N9) C0MISC6AE 90N4 X X X ROOF CURBS - downflow Clip Curb 8 in. height ZCURB40A- 95W8 X X X 4 in. height ZCURB4A- 95W9 X X X 8 in. height ZCURB4A- 95W0 X X X 4 in. height ZCURB4A- 95W X X X Standard Curb 4 in. height ZCURB0A- 9W50 X X X CEILING DIFFUSERS Step-Down - Order one RTD9-65-R 7G87 X X X Flush - Order one FD9-65-R 7G86 X X X NOTE - Ceiling Diffuser Transitions are not furnished and must be field fabricated. NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. OX - Field Installed or Configure to Order (factory installed) O - Configure to Order (Factory Installed) X - Field Installed. Z-Series Packaged Electric / Electric to 5 Tons / Page 8

SPECIFICATIONS General Data Nominal Tonnage Ton 4 Ton 5 Ton Model No. ZCA06S4B ZCA048S4B ZCA060S4B Efficiency Type Standard Standard Standard Cooling Performance Gross Cooling Capacity - Btuh 6,00 47,000 58,900 Net Cooling Capacity - Btuh 4,600 45,000 57,000 AHRI Rated Air Flow - 00 550 650 Sound Rating Number (SRN) (dba) 77 80 8 Total Unit Power - kw. 4. 5. SEER (Btuh/Watt).00.00.00 EER (Btuh/Watt).50 0.60 0.70 Refrigerant Type R-40A R-40A R-40A Charge Furnished 4 lbs. oz. 4 lbs. 6 oz. 5 lbs. 6 oz. Electric Heat Available - See page 7 5, 7.5, 0, 5 kw 5, 7.5, 0, 5,.5 kw Compressor Type (one per unit) Scroll Scroll Scroll Outdoor Coil Net face area - sq. ft..8.8 5. Outdoor Coil Fan Number of rows Fins / inch Motor HP () /6 (PSC) () /4 (PSC) () / (PSC) Motor rpm 85 85 075 Total motor watts 00 0 60 Diameter - in. () () () Number of blades 4 4 Total air volume - 700 00 800 Indoor Coil Net face area - sq. ft. 8.4 8.4 8.4 Indoor Blower & Drive Selection Tube diameter - in. /8 /8 /8 Number of rows Fins per inch 4 4 4 Drain Connection (no.and size) - in. () NPT () NPT () NPT Expansion device type Fixed Orifice Fixed Orifice Fixed Orifice Nominal Motor HP 4 hp,.5 hp 4 hp,.5 hp 4 hp,.5 hp Maximum Usable Motor HP.5 hp,.7 hp.5 hp,.7 hp.5 hp,.7 hp Available Drive Kits Kit #Z0 678-05 rpm Kit #Z04 964-47 rpm Kit #Z0 80-6 rpm 5 Kit #Z05 098-490 rpm Kit #Z0 906-8 rpm 5 Kit #Z06 6-64 rpm Wheel nominal diameter x width - in. 0 x 0 0 x 0 0 x 0 Filters Type Disposable Number and size - in. (4) 4 x 0 x Electrical Characteristics - 60 Hz 08/0V phase 08/0V, phase 08/0V, phase 08/0V, 460V & 575V phase 08/0V 460V & 575V phase 08/0V 460V & 575V phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 0/40: 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Sound Rating Number (SRN) rated in accordance with test conditions included in ANSI/AHRI Standard 70-008. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors furnished are shown. In Canada, nominal motor hp is also maximum usable motor hp output. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on the motor nameplate. 4 hp blower motor is not available for 08/0V-ph applications. 5.5 hp motor is required with Z05 and Z06 drive kits. Z-Series Packaged Electric / Electric to 5 Tons/ Page 9

RATINGS NOTE For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TON STANDARD EFFICIENCY ZCA06S4 Outdoor Air Temperature Entering Outdoor Coil Entering Total 85 F 95 F 05 F 5 F Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F 960.5..69.84.97.0.40.69.84.99 7.8.7.69.86.00.6.04.70.90.00 6 F 00 6.0..75.9.00.4.4.75.9.00 0.0.7.75.95.00 5.5.05.78.99.00 440 8.0..79.97.00 5..4.80.98.00.8.74.8.00.00 7..06.85.00.00 960 6.0..5.67.8.4.4.5.67.8 0..7.50.67.8 5.6.05.49.68.87 67 F 00 8.6..57.7.87 5.8.4.56.7.89..74.55.74.9 7..06.55.77.96 440 40.5..60.77.94 7.4.4.60.78.95.6.74.59.80.98 8.7.07.60.84.00 960 8.4..8.5.65 5.6.4.6.5.65..74.4.50.65 7.5.06..49.67 7 F 00 4...4.57.7 8..4.40.56.7 4.4.75.7.55.7 9.4.07.5.55.75 440 4.0.4.4.60.76 9.9.44.4.59.76 6.0.76.40.59.78 0.6.08.5.60.8 4 TON STANDARD EFFICIENCY ZCA048S4 Outdoor Air Temperature Entering Outdoor Coil Entering Total 85 F 95 F 05 F 5 F Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F 80 46.0.09.7.85.97 4.9.48.7.86.99 9.5.9.7.87.00 4. 4.48.7.9.00 6 F 600 49..09.76.9.00 45.7.48.77.9.00 4.9.94.78.95.00 6. 4.50.8.99.00 90 5.5.09.8.97.00 47.8.49.8.99.00 4.9.96.8.00.00 8.4 4.5.87.00.00 80 49..09.55.69.8 45.9.49.54.69.8 4..94.5.69.84 6.9 4.50.5.7.88 67 F 600 5.5.0.58.74.88 48.9.49.58.75.89 44.9.96.58.76.9 8.9 4.5.58.79.97 90 55.0.0.6.79.94 5..50.6.80.96 46.8.98.6.8.99 40.4 4.5.6.86.00 80 5..0.4.54.67 48.8.49.40.54.67 44.9.96.8.5.68 9. 4.5.6.5.70 7 F 600 55.8..4.58.7 5.9.50.4.58.7 47.6.97.40.57.74 4.4 4.54.8.58.77 90 58...44.6.77 54..5.4.6.78 49.6.99.4.6.80 4.9 4.55.4.64.84 5 TON STANDARD EFFICIENCY ZCA060S4 Outdoor Air Temperature Entering Outdoor Coil Entering Total 85 F 95 F 05 F 5 F Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F kbtuh kw 75 F 80 F 85 F 600 56.5.67.7.87.00 5.4 4..74.90.00 48.0 4.65.76.9.00 4.0 5.6.78.97.00 6 F 000 59.4.70.78.95.00 55. 4.6.80.98.00 50.5 4.69.8.00.00 45.9 5..86.00.00 400 6.7.7.84.00.00 57.7 4.9.86.00.00 5.4 4.7.89.00.00 48.5 5.6.94.00.00 600 60..7.57.70.84 56.0 4.6.57.7.86 5.4 4.70.57.7.89 46. 5..58.76.94 67 F 000 6..7.60.76.9 58.8 4.0.6.78.95 5.8 4.74.6.8.99 48.4 5.6.6.84.00 400 65.6.76.64.8.99 60.8 4..65.84.00 55.7 4.76.66.87.00 49.7 5.8.68.9.00 600 64.0.74.4.55.68 59.5 4.0.4.56.70 54.7 4.75.4.56.7 49. 5.7.40.57.74 7 F 000 67..77.44.59.74 6.4 4.4.44.60.76 57. 4.79.4.6.78 5.7 5.4.4.6.8 400 69.6.80.45.6.80 64.7 4.7.45.64.8 59. 4.8.45.66.85 5. 5.45.45.68.90 Z-Series Packaged Electric / Electric to 5 Tons / Page 0

BLOWER DATA - BELT DRIVE - ZCA06 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: - Any factory installed options air resistance (heat section, economizer, wet coil, etc.). - Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 4 for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW Air Volume External Static - in. w.g. 0.0 0.0 0.0 0.40 0.50 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furnished Kit Z0 900 555 0.6 6 0.7 69 0.9 76 0.0 8 0. 897 0.4 956 0.6 00 0.9 000 577 0.8 644 0.9 75 0. 786 0. 855 0.4 99 0.7 976 0.9 08 0. 00 60 0.0 670 0. 74 0. 8 0.5 879 0.8 94 0.0 996 0. 047 0.7 00 69 0. 698 0.4 770 0.6 840 0.8 905 0. 965 0.4 08 0.8 066 0.4 00 659 0.5 79 0.7 800 0.0 869 0. 9 0.5 989 0.9 040 0.4 087 0.47 400 69 0.8 76 0. 8 0.4 899 0.7 960 0.40 04 0.44 06 0.48 08 0.5 500 78 0. 798 0.5 866 0.8 90 0.4 987 0.45 09 0.50 086 0.54 0 0.58 Air Volume External Static - in. w.g. 0.90.00.0.0.0.40.50.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Kit Z04 900 060 0. 08 0.4 54 0.7 97 0.40 9 0.44 79 0.47 9 0.5 59 0.55 000 077 0.5 0.8 68 0.4 0.45 5 0.49 9 0.5 0 0.56 70 0.60 00 094 0.40 9 0.4 8 0.46 5 0.50 66 0.54 05 0.58 4 0.6 8 0.66 00 0.45 56 0.48 99 0.5 4 0.55 8 0.59 9 0.64 57 0.68 94 0.7 00 0.50 74 0.54 6 0.57 57 0.6 96 0.66 4 0.70 7 0.74 408 0.78 400 5 0.56 9 0.60 4 0.64 74 0.68 0.7 5 0.77 87 0.8 4 0.86 500 7 0.6 0.66 5 0.7 9 0.75 0.79 68 0.84 404 0.89 440 0.9 HORIZONTAL Air Volume External Static - in. w.g. 0.0 0.0 0.0 0.40 0.50 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furnished Kit Z0 Kit Z04 900 57 0.4 64 0.6 7 0.9 785 0. 860 0.4 9 0.7 99 0.9 09 0. 000 60 0.6 67 0.9 74 0. 85 0.4 887 0.7 954 0.0 00 0. 055 0.6 00 66 0.9 706 0. 776 0.5 847 0.8 96 0. 977 0.4 08 0.7 070 0.4 00 674 0. 744 0.6 8 0.9 88 0. 944 0.5 999 0.8 045 0.4 087 0.45 00 76 0.6 784 0.9 85 0. 94 0.6 97 0.40 00 0.4 064 0.47 06 0.50 400 759 0.0 84 0.4 888 0.7 946 0.4 998 0.45 04 0.49 086 0.5 9 0.55 500 80 0.5 865 0.9 95 0.4 979 0.47 07 0.5 070 0.55 0.58 56 0.6 Air Volume External Static - in. w.g. 0.90.00.0.0.0.40.50.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Kit Z04 900 085 0.5 5 0.8 8 0.40 7 0.4 68 0.45 05 0.49 4 0.5 79 0.57 000 099 0.9 48 0.4 95 0.44 9 0.47 79 0.50 6 0.54 5 0.58 89 0.6 00 4 0.44 6 0.46 0 0.49 5 0.5 9 0.55 9 0.59 64 0.64 40 0.68 00 0.48 80 0.5 6 0.54 69 0.57 08 0.6 4 0.66 78 0.70 44 0.75 00 5 0.5 99 0.56 45 0.59 87 0.6 4 0.68 59 0.7 94 0.77 49 0.8 400 75 0.58 0.6 66 0.66 06 0.70 4 0.75 76 0.80 40 0.85 446 0.89 500 0 0.65 46 0.68 89 0.7 7 0.78 6 0.8 95 0.88 49 0.9 464 0.98 Z-Series Packaged Electric / Electric to 5 Tons/ Page

BLOWER DATA - BELT DRIVE - ZCA048 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: - Any factory installed options air resistance (heat section, economizer, wet coil, etc.). - Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 4for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW Air Volume External Static - in. w.g. 0.0 0.0 0.0 0.40 0.50 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furnished Kit Z0 00 69 0. 698 0.4 770 0.6 840 0.8 905 0. 965 0.4 08 0.8 066 0.4 00 659 0.5 79 0.7 800 0.0 869 0. 9 0.5 989 0.9 040 0.4 087 0.47 400 69 0.8 76 0. 8 0.4 899 0.7 960 0.40 04 0.44 06 0.48 08 0.5 500 78 0. 798 0.5 866 0.8 90 0.4 987 0.45 09 0.50 086 0.54 0 0.58 600 766 0.7 85 0.40 900 0.4 960 0.47 05 0.5 065 0.55 0 0.60 5 0.65 700 806 0.4 87 0.45 94 0.48 99 0.5 04 0.56 09 0.6 4 0.66 76 0.7 800 845 0.47 908 0.50 967 0.54 0 0.58 07 0.6 7 0.68 59 0.7 00 0.78 900 884 0.5 944 0.56 000 0.60 05 0.64 099 0.69 4 0.75 85 0.80 5 0.86 000 9 0.59 979 0.6 0 0.67 08 0.7 8 0.77 7 0.8 0.89 5 0.95 Air Volume External Static - in. w.g. 0.90.00.0.0.0.40.50.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Kit Z0 Kit Z05 00 0.45 56 0.48 99 0.5 4 0.55 8 0.59 9 0.64 57 0.68 94 0.7 00 0.50 74 0.54 6 0.57 57 0.6 96 0.66 4 0.70 7 0.74 408 0.78 400 5 0.56 9 0.60 4 0.64 74 0.68 0.7 5 0.77 87 0.8 4 0.86 500 7 0.6 0.66 5 0.7 9 0.75 0.79 68 0.84 404 0.89 440 0.9 600 9 0.69 4 0.7 7 0.78 0.8 50 0.87 87 0.9 4 0.97 457.0 700 6 0.76 55 0.8 95 0.86 0.90 70 0.95 406.00 44.05 475.0 800 9 0.84 79 0.89 7 0.94 55 0.99 9.04 46.09 46.4 494.9 900 64 0.9 0 0.98 4.0 78.08 4.4 448.9 48.4 54.9 000 90.0 8.07 66. 40.9 46.4 470.9 50.5 55.40 HORIZONTAL Air Volume External Static - in. w.g. 0.0 0.0 0.0 0.40 0.50 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furnished Kit Z0 00 674 0. 744 0.6 8 0.9 88 0. 944 0.5 999 0.8 045 0.4 087 0.45 00 76 0.6 784 0.9 85 0. 94 0.6 97 0.40 00 0.4 064 0.47 06 0.50 400 759 0.0 84 0.4 888 0.7 946 0.4 998 0.45 04 0.49 086 0.5 9 0.55 500 80 0.5 865 0.9 95 0.4 979 0.47 07 0.5 070 0.55 0.58 56 0.6 600 847 0.40 905 0.45 96 0.50 0 0.54 058 0.58 00 0.6 4 0.65 85 0.68 700 890 0.47 944 0.5 997 0.57 047 0.6 09 0.66 0.69 7 0.7 6 0.76 800 90 0.54 98 0.60 0 0.65 08 0.70 4 0.74 65 0.77 06 0.80 48 0.84 900 970 0.6 00 0.68 069 0.7 6 0.78 58 0.8 99 0.85 9 0.89 80 0.9 000 009 0.7 058 0.76 06 0.8 5 0.86 9 0.9 0.94 7 0.98.04 Air Volume External Static - in. w.g. 0.90.00.0.0.0.40.50.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Kit Z0 Kit Z05 00 0.48 80 0.5 6 0.54 69 0.57 08 0.6 4 0.66 78 0.70 44 0.75 00 5 0.5 99 0.56 45 0.59 87 0.6 4 0.68 59 0.7 94 0.77 49 0.8 400 75 0.58 0.6 66 0.66 06 0.70 4 0.75 76 0.80 40 0.85 446 0.89 500 0 0.65 46 0.68 89 0.7 7 0.78 6 0.8 95 0.88 49 0.9 464 0.98 600 9 0.7 7 0.76 0.8 50 0.86 84 0.9 46 0.97 450.0 485.07 700 58 0.80 00 0.85 8 0.90 74 0.96 407.0 440.07 47. 508.7 800 89 0.89 8 0.94 65.00 99.06 4. 465.8 498. 5.8 900 9 0.99 57.05 9. 46.8 459.4 49.0 54.5 558.9 000 50.0 87.6 4. 454.0 486.6 58.4 55.47 584.5 Z-Series Packaged Electric / Electric to 5 Tons / Page

BLOWER DATA - BELT DRIVE - ZCA060 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: - Any factory installed options air resistance (heat section, economizer, wet coil, etc.). - Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 4 for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW Air Volume External Static - in. w.g. 0.0 0.0 0.0 0.40 0.50 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furnished Kit Z0 600 787 0.8 854 0.4 98 0.44 976 0.48 00 0.5 078 0.56 0.6 64 0.66 700 87 0.4 89 0.46 95 0.49 007 0.5 058 0.58 05 0.6 48 0.68 89 0.7 800 868 0.48 99 0.5 986 0.55 08 0.59 087 0.64 0.69 74 0.75 4 0.80 900 907 0.54 966 0.58 09 0.6 069 0.66 6 0.7 60 0.77 00 0.8 40 0.88 000 946 0.60 00 0.65 05 0.69 0 0.74 46 0.79 88 0.85 8 0.9 67 0.98 00 984 0.68 07 0.7 086 0.77 0.8 76 0.89 7 0.95 56.0 95.08 00 0 0.75 07 0.8 0 0.86 65 0.9 07 0.99 47.05 86. 4.9 00 059 0.84 08 0.90 54 0.96 97.0 9.0 78.7 6.4 54. 400 097 0.95 44.0 88.08.5 7. 0.0 48.8 85.45 Air Volume External Static - in. w.g. 0.90.00.0.0.0.40.50.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Kit Z0 Kit Z06 600 05 0.70 45 0.75 84 0.79 0.84 6 0.88 97 0.9 4 0.98 467.0 700 8 0.78 68 0.8 07 0.87 45 0.9 8 0.97 47.0 45.07 486. 800 5 0.85 9 0.9 0.96 68.0 404.06 49. 47.6 506. 900 79 0.94 7.00 55.05 9.0 47.6 46. 494.6 57. 000 05.04 4.0 80.5 46. 450.6 484. 56.7 549.4 00.4 70. 407.6 44. 475.8 508.4 540.48 57.5 00 6.6 98. 44.8 468.44 50.50 5.55 564.6 596.66 00 9.9 47.45 46.5 495.57 57.6 559.68 590.7 6.78 400 4.5 456.59 490.65 5.7 555.76 586.8 67.87 649.9 HORIZONTAL Air Volume External Static - in. w.g. 0.0 0.0 0.0 0.40 0.50 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furn. Kit Z0 600 864 0.4 9 0.46 976 0.5 07 0.56 07 0.60 0.6 55 0.66 98 0.69 700 907 0.48 96 0.5 0 0.58 06 0.6 05 0.67 46 0.70 87 0.7 0 0.77 800 948 0.56 999 0.6 049 0.66 096 0.7 9 0.75 80 0.78 0.8 6 0.86 900 987 0.64 07 0.69 086 0.74 0.79 74 0.8 4 0.86 55 0.90 95 0.95 000 08 0.7 076 0.78 0.8 68 0.87 0 0.9 50 0.96 89.00 8.06 00 07 0.8 7 0.86 6 0.9 06 0.96 47.0 86.06 4. 6.8 00 6 0.9 60 0.96 04.0 45.07 85..8 60.5 96. 00 6.0 04.07 45. 85.9.5 60. 96.8 4.45 400 07.4 48.0 88.6 6. 6.9 98.46 4.5 468.60 Air Volume External Static - in. w.g. 0.90.00.0.0.0.40.50.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Kit Z0 Kit Z06 600 4 0.7 84 0.77 4 0.8 60 0.88 94 0.9 46 0.99 460.04 495.08 700 7 0.8 0.86 50 0.9 85 0.98 48.04 45.09 485.4 59.9 800 0 0.90 4 0.96 77.0 4.08 444.5 477.0 50.5 544.0 900 4.0 7.07 406. 49.0 47.6 504. 57.7 57.4 000 65. 40.9 45.5 468. 500.8 5.44 565.49 598.5 00 98.5 4. 466.8 497.45 59.5 56.56 594.6 66.65 00 4.8 465.45 497.5 58.58 560.64 59.69 6.7 656.77 00 466.5 498.59 59.66 560.7 59.77 6.8 654.86 686.90 400 500.67 5.74 56.80 59.86 64.9 655.96 686.00 78.04 Z-Series Packaged Electric / Electric to 5 Tons/ Page

BLOWER DATA DRIVE KIT SPECIFICATIONS Blower Motor Choice (HP) Model No. Nominal Maximum Nominal Maximum 06.5.5.7 048.5.5.7 060.5.5.7 Drive Kit No. RPM Range Z0 678-05 Z04 964-47 Z0 80-6 Z05 098-490 Z0 906-8 Z06 6-64 NOTE - Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors furnished are shown. In Canada, nominal motor hp is also maximum usable motor hp. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on the motor nameplate..5 hp motor is required with Z05 and Z06 drive kits. POWER EXHAUST FAN PERFORMANCE Return Air System Static Pressure - in. w.g. Air Volume Exhausted 0.00 865 0.05 785 0.0 70 0.5 60 0.0 545 0.5 450 0.0 50 0.5 40 OPTIONS / ACCESSORIES AIR RESISTANCE - in. w.g. Air Volume Wet Indoor Coil Economizer Electric Heat 06-048 060 Downflow Horizontal 900 0.0 - - - 0.0 0.04 0.05 000 0.0 - - - 0.04 0.04 0.05 00 0.0 - - - 0.05 0.04 0.06 00 0.0 - - - 0.06 0.05 0.06 00 0.0 - - - 0.08 0.05 0.07 400 0.0 - - - 0.09 0.06 0.07 500 0.0 - - - 0.0 0.07 0.08 600 0.0 0.04 0. 0.08 0.09 700 0.04 0.05 0. 0.08 0.0 800 0.04 0.05 0.5 0.09 0. 900 0.04 0.06 0.6 0.0 0. 000 0.05 0.06 0.7 0. 0. 00 - - - 0.07 0.9 0. 0.4 00 - - - 0.08 0.0 0.4 0.5 00 - - - 0.08 0. 0.5 0.7 400 - - - 0.09 0. 0.7 0.8 CEILING DIFFUSERS AIR RESISTANCE (in. w.g.) RTD9-65 Step-Down Diffuser FD9-65 Air Volume Ends Side & All Ends & Flush Open Ends Open Sides Open Diffuser 800 0.5 0. 0. 0. 000 0.9 0.6 0.4 0.4 00 0.5 0.0 0.7 0.7 400 0. 0.6 0.0 0.0 600 0.4 0. 0.0 0.4 800 0.56 0.40 0.0 0.0 000 0.7 0.50 0.6 0.6 00 0.95 0.6 0.44 0.44 Z-Series Packaged Electric / Electric to 5 Tons / Page 4 CEILING DIFFUSER AIR THROW DATA Air Volume - Effective Throw - ft. Model No. RTD9-65 FD9-65 800 0-7 4-8 000 0-7 5-0 00-8 6-400 - 9 7-4 600-0 8-5 800-0 - 8 000 4 - - 9 00 6-5 - 0 Effective throw based on terminal velocities of 75 ft. per minute.

ELECTRICAL DATA ZCA06S4 Voltage - 60hz 08/0V - Ph 08/0V - Ph 460V - Ph 575V - Ph Compressor Rated Load Amps 5. 8.7 4.6 Locked Rotor Amps 70 70 7 Outdoor Fan Motor () 0.5 HP Indoor Blower Motor Maximum Overcurrent Protection Minimum Circuit Ampacity Full Load Amps 0.6 0.45 Full Load Amps.5.5 0.6 0.6 Horsepower.5.5.5.5 Full Load Amps 4.6 6.6..7.4 Unit Only 45 5 5 5 5 5 5 With () 0.5 HP 45 5 5 5 5 5 5 Unit Only 7 9 8 9 7 8 With () 0.5 HP 8 0 9 0 8 8 ELECTRIC HEAT DATA Electric Heat Voltage 08V 40V 08V 40V 08V 40V 480V 480V 600V 600V Maximum Overcurrent Protection Minimum Circuit Ampacity Maximum Overcurrent Protection Minimum Circuit Ampacity Unit+ Electric Heat Unit+ Electric Heat Unit+ Electric Heat and () 0.5 HP Unit+ Electric Heat and () 0.5 HP 5 kw 45 45 5 5 5 5 5 5 5 5 7.5 kw 50 60 0 0 0 5 5 0 5 5 0 kw 60 70 5 40 5 40 0 0 5 0 5 kw 90 00 45 60 50 60 0 0 5 5 5 kw 7 40 9 4 9 0 7.5 kw 48 5 6 9 8 4 6 0 kw 59 66 6 5 9 8 9 5 6 5 kw 8 9 45 5 48 54 6 7 5 kw 45 45 5 5 5 0 5 5 5 5 7.5 kw 50 60 0 5 0 5 5 0 5 5 0 kw 70 70 5 40 40 45 0 0 5 0 5 kw 90 00 50 60 50 60 0 0 5 5 5 kw 9 4 4 6 9 0 7.5 kw 50 55 8 0 5 6 0 kw 6 68 4 8 7 4 9 0 5 6 5 kw 84 94 47 5 50 56 6 8 ELECTRIC HEAT ACCESSORIES Unit Fuse Block Unit Only 0A6 0A7 0A7 0A9 0A9 0A9 0A9 Unit + 0A6 0A7 0A7 0A9 0A9 0A9 0A9 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Z-Series Packaged Electric / Electric to 5 Tons/ Page 5

ELECTRICAL DATA 4 TON ZCA048S4 Voltage - 60hz 08/0V - Ph 08/0V - Ph 460V - Ph 575V - Ph Compressor Rated Load Amps 0 5.5 4.7 Locked Rotor Amps 99 86 7 4 Outdoor Fan Motor () 0.5 HP Indoor Blower Motor Maximum Overcurrent Protection Minimum Circuit Ampacity Full Load Amps.7.7 0.9 0.7 Full Load Amps.5.5 0.6 0.6 Horsepower.5.5.5.5 Full Load Amps 4.6 6.6..7.4 Unit Only 50 0 0 5 5 5 5 With () 0.5 HP 50 0 0 5 5 5 5 Unit Only 8 0 9 9 With () 0.5 HP 40 4 9 0 ELECTRIC HEAT DATA Electric Heat Voltage 08V 40V 08V 40V 08V 40V 480V 480V 600V 600V Maximum Overcurrent Protection Minimum Circuit Ampacity Maximum Overcurrent Protection Minimum Circuit Ampacity Unit+ Electric Heat Unit+ Electric Heat Unit+ Electric Heat and () 0.5 HP Unit+ Electric Heat and () 0.5 HP 5 kw 50 50 0 0 0 0 5 5 5 5 7.5 kw 50 60 0 0 0 5 5 0 5 5 0 kw 60 70 5 40 5 40 0 0 5 0 5 kw 90 00 45 60 50 60 0 0 5 5.5 kw 5 50 70 80 70 80 40 40 0 5 5 kw 8 40 4 9 0 7.5 kw 48 5 6 9 8 4 6 0 kw 59 66 6 5 9 8 9 5 6 5 kw 8 9 45 5 48 54 6 7.5 kw 6 65 74 67 76 7 8 0 5 kw 50 50 0 0 0 0 5 5 5 5 7.5 kw 50 60 0 5 0 5 5 0 5 5 0 kw 70 70 5 40 40 45 0 0 5 0 5 kw 90 00 50 60 50 60 0 0 5 5.5 kw 5 50 70 80 70 80 40 40 0 5 5 kw 40 4 4 6 9 0 7.5 kw 50 55 8 0 5 6 0 kw 6 68 4 8 7 4 9 0 5 6 5 kw 84 94 47 5 50 56 6 8.5 kw 8 67 76 69 78 8 9 0 ELECTRIC HEAT ACCESSORIES Unit Fuse Block Unit Only 0A6 0A7 0A7 0A9 0A9 0A9 0A9 Unit + 0A6 0A7 0A7 0A9 0A9 0A9 0A9 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Z-Series Packaged Electric / Electric to 5 Tons / Page 6

ELECTRICAL DATA 5 TON ZCA060S4 Voltage - 60hz 08/0V - Ph 08/0V - Ph 460V - Ph 575V - Ph Compressor Rated Load Amps..5 8 5 Locked Rotor Amps 5 09 59 40 Outdoor Fan Motor () 0.5 HP Indoor Blower Motor Maximum Overcurrent Protection Minimum Circuit Ampacity Full Load Amps.7.7 0.9 Full Load Amps.5.5 0.6 0.6 Horsepower.5.5.5.5 Full Load Amps 4.6 6.6..7.4 Unit Only 60 5 5 0 0 5 5 With () 0.5 HP 60 5 40 0 0 5 5 Unit Only 4 4 6 4 4 9 0 With () 0.5 HP 4 5 7 4 5 0 ELECTRIC HEAT DATA Electric Heat Voltage 08V 40V 08V 40V 08V 40V 480V 480V 600V 600V Maximum Overcurrent Protection Minimum Circuit Ampacity Maximum Overcurrent Protection Minimum Circuit Ampacity Unit+ Electric Heat Unit+ Electric Heat Unit+ Electric Heat and () 0.5 HP Unit+ Electric Heat and () 0.5 HP 5 kw 60 60 5 5 5 5 0 0 5 5 7.5 kw 60 60 5 5 5 5 0 0 5 5 0 kw 60 70 5 40 5 40 0 0 5 0 5 kw 90 00 45 60 50 60 0 0 5 5.5 kw 5 50 70 80 70 80 40 40 0 5 5 kw 4 4 4 4 6 6 4 4 9 0 7.5 kw 48 5 6 9 8 4 6 0 kw 59 66 6 5 9 8 9 5 6 5 kw 8 9 45 5 48 54 6 7.5 kw 6 65 74 67 76 7 8 0 5 kw 60 60 5 5 40 40 0 0 5 5 7.5 kw 60 60 5 5 40 40 0 0 5 5 0 kw 70 70 5 40 40 45 0 0 5 0 5 kw 90 00 50 60 50 60 0 0 5 5.5 kw 5 50 70 80 70 80 40 40 0 5 5 kw 4 4 5 5 7 7 4 5 0 7.5 kw 50 55 8 0 5 6 0 kw 6 68 4 8 7 4 9 0 5 6 5 kw 84 94 47 5 50 56 6 8.5 kw 8 67 76 69 78 8 9 0 ELECTRIC HEAT ACCESSORIES Unit Fuse Block Unit Only 0A6 0A8 0A8 0A9 0A9 0A9 0A9 Unit + 0A6 0A8 0A8 0A9 0A9 0A9 0A9 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Z-Series Packaged Electric / Electric to 5 Tons/ Page 7

ELECTRIC HEAT CAPACITIES Input Voltage No of Stages 5 kw 7.5 kw 0 kw 5 kw.5 kw kw input Btuh Output No of Stages kw input Btuh Output No of Stages kw input Btuh Output No of Stages kw input Btuh Output No of Stages kw input Btuh Output 08.8,800 5.6 9,00 7.5 5,600. 8,400 6.9 57,700 0 4. 4,00 6.,500 8.4 8,700.6 4,000 8.9 64,500 0 4.6 5,700 6.9,500 9.,400.8 47,000 0.7 70,700 40 5.0 7,00 7.5 5,600 0.0 4,00 5.0 5,00.5 76,800 440 4. 4,00 6.,500 8.4 8,700.6 4,000 8.9 64,500 460 4.6 5,700 6.9,500 9.,400.8 47,000 0.7 70,700 480 5.0 7,00 7.5 5,600 0.0 4,00 5.0 5,00.5 76,800 550 4. 4,00 6.,500 8.4 8,700.6 4,000 8.9 64,500 575 4.6 5,700 6.9,500 9.,400.8 47,000 0.7 70,700 600 5.0 7,00 7.5 5,600 0.0 4,00 5.0 5,00.5 76,800 Z-Series Packaged Electric / Electric to 5 Tons / Page 8

UNIT CLEARANCES - INCHES (MM) UNIT WITH DOWNFLOW ECONOMIZER C OUTDOOR AIR HOOD D B A UNIT WITH HORIZONTAL ECONOMIZER C HORIZONTAL OUTDOOR AIR HOOD D B A Unit Clearance A B C Downflow C Horizontal in. mm in. mm in. mm in. mm in. mm Service Clearance 6 94 6 94 6 94 60 54 6 94 Minimum Operation Clearance 6 94 6 94 6 94 60 54 6 94 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. D Top Clearance Unobstructed Z-Series Packaged Electric / Electric to 5 Tons/ Page 9

OUTDOOR SOUND DATA Unit Model No. Octave Band Linear Sound Power Levels db, re 0 - Watts - Center Frequency - Hz 5 50 500 000 000 4000 8000 Sound Rating Number (SRN) (dba) 06 8 78 77 7 68 66 6 77 048 84 80 79 74 70 67 6 80 060 86 8 8 78 74 68 65 8 Sound Rating Number according to ANSI/AHRI Standard 70-008. SRN is the overall A-Weighted Sound Power Level, (LWA), db (00 Hz to 0,000 Hz). Z-Series Packaged Electric / Electric to 5 Tons / Page 0

WEIGHT DATA Model Number Net Shipping Base Max. Base Max. lbs. kg lbs. kg lbs. kg lbs. kg 06S 45 05 50 8 456 07 507 0 048S 465 56 4 470 5 6 060S 497 5 550 49 50 8 555 5 Base Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, etc.) OPTIONs / ACCESSORIES ECONOMIZER Economizer Economizer, Includes Outdoor Air Hood and Barometric Relief Dampers with Hood OUTDOOR AIR Outdoor Air Dampers lbs. Shipping Weights Downflow - ZECON0A- 65 9 Horizontal - ZECON6A- 9 4 Motorized ZDAMPA- 0 4 Manual ZDAMPA- 0 POWER EXHAUST Standard Static Downflow 54 4 ELECTRIC HEAT ROOF CURBS - DOWNFLOW Clip Curb kg Horizontal 4 9 5 kw - ZEH0050AN 5 7.5 kw - ZEH0075AN 6 0 kw - ZEH000AN 7 5 kw - ZEH050AN 7.5 kw - ZEH05AN 9 8 in. height ZCURB40A- 80 6 4 in. height ZCURB4A- 95 4 8 in. height ZCURB4A- 0 50 4 in. height ZCURB4A- 5 57 Standard 4 in. height ZCURB0A- 06 48 CEILING DIFFUSERS Step-Down RTD9-65-R 67 0 Flush FD9-65-R 7 7 Z-Series Packaged Electric / Electric to 5 Tons/ Page

DIMENSIONS - INCHES (MM) Model CORNER WEIGHTS CENTER OF GRAVITY No. AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm in. mm in. mm 06 6 5 60 07 49 5 6 09 50 9 54 8 54 6 5 9.5 00 7.5 95.5 59 5 65 048 0 54 5 6 0 50 9 6 5 55 55 9 54 9.5 00 7.5 95.5 59 5 65 060 8 58 44 65 8 54 48 67 55 0 59 59 7 58 9.5 00 7.5 95.5 59 5 65 Base Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, largest blower motor, etc.). BOTTOM POWER ENTRY Holes required for Optional Bottom Power Entry Kit Threaded Conduit Fittings Wire Hole Diameter (Provided in Kit) Use Required in Unit Base (Max.) A / ACC 7/8 () B / 4V 7/8 () C /4 POWER -/8 (9) AA 5-5/8 (65) 5-/8 (0) BB 47-/4 (00) BASE CENTER OF GRAVITY BOTTOM RETURN AIR OPENING 0-7/8 (76) 6-/8 (40) -5/8 (46) -/8 (8) DD 4-9/6 (64) A B C BOTTOM POWER ENTRY (See Table) 75-7/8 (97) FF -/8 (08) TOP VIEW (Base) BOTTOM SUPPLY AIR OPENING EE 9 (77) 7-/4 (45) 5-/4 (46) CC 5-/8 (0) 45-/4 (49) POWER ENTRY 7-/4 (87) 5-9/6 (4) 6-7/8 (97) (5) Either side -/ (89) -7/8 (0) 5-/4 (46) CONDENSATE OUTLET HORIZONTAL SUPPLY 6-/4 (59) HORIZONTAL RETURN 5-/4 (654) 8-/8 () 5-/4 (46) (5) 47-/4 BASE (00) END VIEW (5) LIFTING HOLES (For rigging) FRONT VIEW -/ (89) TYP. 6-/ (65) 7-/8 (44) 7 (686) (787) END VIEW 0-7/8 (76) Z-Series Packaged Electric / Electric to 5 Tons / Page

ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER (Downflow Applications) 8-/4 (464) 8-/4 (464) (787) /4 (9) OPTIONAL OUTDOOR AIR HOOD (Furnished with Economizer) 8-/4 (464) SIDE VIEW OUTDOOR AIR DAMPER HOOD DETAIL FOR OPTIONAL MANUAL OR MOTORIZED OUTDOOR AIR DAMPERS (Downflow or Horizontal Applications) 0-5/8 (70) OPTIONAL OUTDOOR AIR DAMPERS AND PANEL OUTDOOR AIR DAMPER HOOD 4-/ (080) 6-/ (49) 4 (56) (559) OUTDOOR AIR DAMPER HOOD (Furnished) SIDE VIEW 0-5/8 (70) Z-Series Packaged Electric / Electric to 5 Tons/ Page

ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) RETURN AIR DUCT INLET (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) OUTDOOR AIR/ BAROMETRIC RELIEF HOOD (Furnished with Economizer) (787) TOP VIEW -7/8 (0) 5-/4 (46) 6-/ (65) This opening not used in Horizontal Applications with Economizer HORIZONTAL SUPPLY AIR OPENING 7-/8 (44) END VIEW HORIZONTAL RETURN AIR OPENING 6 (406) 8-/4 (97) 6 (406) 8-/4 (46) FRESH AIR OPENING EXHAUST OPENING Note - Return Air Duct and Transition must be supported. HORIZONTAL ECONOMIZER LOCATION 7-/4 (87) BACK VIEW Z-Series Packaged Electric / Electric to 5 Tons / Page 4

ACCESSORY DIMENSIONS - INCHES (MM) CLIP CURB - DOUBLE DUCT OPENING 4-7/8 (78) -5/8 (9) NOTE - Roof deck may be omitted within confines of curb. INSULATED FILLER PANELS () RETURN OPENING SUPPLY OPENING 0-/4 (54) -/4 (44) BOTTOM POWER ENTRY (76) -7/8 (5) -/4 (44) 8-/4 (984) OPENING 4-/4 (07) 9-/8 (8) 0-/4 (54) (76) 4-/4 (870) OPENING -/4 (7) 70-7/8 (800) 0-/8 (765) 8 (0) 4 (56) 8 (457) 4 (60) -/4 (44) TYPICAL FLASHING DETAIL FOR ROOF CURB DETAIL ROOF CURB GASKET (Supplied with Curb) PACKAGED UNIT -/4 (44) / () BASE BOTTOM NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) COUNTER FLASHING (Field Supplied) CANT STRIP (Field Supplied) ROOFING MATERIAL 8 (0) 4 (56) 8 (457) 4 (60) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP RIGID INSULATION (Field Supplied) -/4 (44) Z-Series Packaged Electric / Electric to 5 Tons/ Page 5

ACCESSORY DIMENSIONS - INCHES (MM) STANDARD ROOF CURBS - DOUBLE DUCT OPENING 4-7/8 (78) -5/8 (9) INSULATED FILLER PANELS () RETURN OPENING SUPPLY OPENING 0-/4 (54) -/4 (44) BOTTOM POWER ENTRY -7/8 (5) -/4 (44) -/6 (84) 8-/4 (984) OPENING 9-/8 (8) 70-7/8 (800) 4-/4 (07) 0-/4 (54) 4 (56) -/4 (44) NOTE - Roof deck may be omitted within confines of curb. TYPICAL FLASHING DETAIL FOR ROOF CURB DETAIL ROOF CURB GASKET (Supplied with Curb) PACKAGED UNIT -/4 (44) (5) BASE BOTTOM NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) COUNTER FLASHING (Field Supplied) CANT STRIP (Field Supplied) ROOFING MATERIAL 4 (56) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP RIGID INSULATION (Field Supplied) (5) Z-Series Packaged Electric / Electric to 5 Tons / Page 6

ACCESSORY DIMENSIONS - INCHES (MM) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS STEP-DOWN CEILING DIFFUSER FLUSH CEILING DIFFUSER E F G H H D E F G H H D G C G C (5) (5) L B J A B A K Model Number RTD9-65 A in. 47-5/8 mm 59 B in. -5/8 mm 600 C in. -/8 mm 89 D in. -/ mm 546 E in. 45-/ mm 56 F in. -/ mm 57 G in. -/ mm 9 H in. 0-/4 mm 7 J in. 45-/ mm 56 K in. -/ mm 546 L in. 7-/8 mm 8 Duct Size in. 8 round mm 457 round Model Number FD9-65 A in. 47-5/8 mm 59 B in. -5/8 mm 600 C in. -/ mm 4 D in. mm 5 E in. 45 mm 4 F in. -/ mm 57 G in. -/4 mm 86 H in. 0-/ mm 67 Duct Size in. 8 round mm 457 round Z-Series Packaged Electric / Electric to 5 Tons/ Page 7

REVISIONS Sections Sound Data Specifications Description of Change Revised. Ratings updated. Visit us at www.allied-commercial.com For the latest technical information, visit us at www.allied-commercial.com Contact us at -800-78-4000 NOTE - Due to Allied Commercial ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 0 Allied Air Enterprises LLC, a Lennox International Inc. Company