2000HG NEW STYLE HELICAL GEAR RATIO MULTIPLIER. INSTALLATION AND MAINTENANCE MANUAL May 4, Indianapolis, Indiana (800)

Similar documents
2000RA SMOOTH BODY WORM GEAR REDUCER. INSTALLATION AND MAINTENANCE MANUAL June 26, Indianapolis, Indiana (800)

2000HG R-SERIES IN-LINE HELICAL GEAR REDUCER

Worm Gear Reducers Installation, Lubrication and Maintenance Instructions

2000HB K-SERIES HELICAL BEVEL GEAR REDUCER

2000RA WORM GEAR REDUCER

Ironman e Series Installation, Lubrication and Maintenance Instructions

Installation, Lubrication and. Maintenance. Instructions CONGRATULATIONS!

Ironman E Series Installation, Lubrication and Maintenance Instructions

FABRICATED AIRLOCK. Installation, Operation & Maintenance Instructions 312 SOUTH HWY. 73, PO BOX 398 FALLS CITY, NE

I N S TA L L AT I O N G U I D E

I N S TA L L AT I O N G U I D E

I N S TA L L AT I O N G U I D E

I N S TA L L AT I O N G U I D E

Gen 2 Portal Gear Hubs for Polaris Ranger Crew 570/900

OPERATING INSTRUCTIONS AND PARTS LIST

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

ALUMINUM RATIO MULTIPLIERS

Universal Bevel Drives Service Manual

INSTALLATION AND OPERATION

DODGE QUANTIS IN-LINE HELICAL REDUCER

Enclosed In-Line Helical & Right Angle Helical Gear Drives

BALDOR IN-LINE HELICAL REDUCER

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Helical Multiplier Series

SERVICE MANUAL DURST MODEL 814-TRANSFER CASE. Phone: DO NOT Revise this, see Teamwork 1 Fax:

Special Purpose Overrunning Clutches ep 300 thru 1027 (less Oil Seals)

Operation and Maintenance Manual. Joyce/Dayton Electric Cylinders with Ball Screw. Standard, Motor mount, and ComDRIVE style

Operation and Maintenance Manual. ACME SCREW Electric Cylinders by Joyce Dayton. Standard, Motor mount, and ComDRIVE style

TECHNICAL SERVICE MANUAL

Maintenance Instructions

3 Phase AC Induction Motors

Installation,Operation, and Lubrication Instructions SPEED REDUCERS ILDE-00 TYPE DE ENGINEERING SERVICE BULLETIN

INTRODUCTION INSTALLATION

Installation and Maintenance Manual

60 Series End-Mount Brake Instructions Standard Housing

TECHNICAL SERVICE MANUAL

KHN SERIES HELICAL & BEVEL SPEED REDUCER

TECHNICAL SERVICE MANUAL

BALDOR RHB (RIGHT-ANGLE HELICAL BEVEL) REDUCER

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Features / How to Order

Technical Information

Operating Instructions & Parts Manual

Low Profile Service Jack Jack Stand Combo

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

PMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks

OPERATION AND MAINTENANCE MANUAL

Fast Lift Service Jack, Low Profile

ERD Electrically Released Brakes

OPERATOR S MANUAL. Model MCT. Mechanical Power Broom

OIL CAPACITIES FOR SERIES HP APPROXIMATE CAPACITIES IN QUARTS AND GALLONS

Highly Efficient, Grease Lubricated, Compact Design. Hypoid gearing delivers efficiencies up to 85% and smooth, quiet operation

TECHNICAL SERVICE MANUAL

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

L DODGE CUMMINS MK-2 + BLK APPS Mount

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Waukesha ISR FPO INSTRUCTION MANUAL INTEGRAL SPEED REDUCER SERIES

LUBRICATION, INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR STAINLESS STEEL CONE DRIVE SPEED REDUCERS

Air / Hydraulic Pump

HP190SL Series Slimline Radon Fans

DODGE CUMMINS GDP Big Line Kit

Low Profile Service Jack

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Spare Parts, Instruction and Maintenance Manual for SPANCO Model 301 Jib Cranes

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

XCEL Series of Turbine Mixers

37SCENE 46SCENE 79SCENE

Guardian FH Flywheel Coupling

Installation and Maintenance Manual

Guardian HH Shaft Coupling

SINCE 1990 IP69K CERTIFIED APPROVED MOTORS REDUCERS INLINE RATIO MULTIPLIERS


Operation and Maintenance Manual for Joyce Dayton. Integrated Actuator- Acme Screw. Maximum capacity: 2000-pounds

L DODGE CUMMINS Maximizer System

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

HGV VARIABLE HYDRAULIC GENERATOR SYSTEMS

8" - 12" Hydraulic Steel Squeeze Off Tool

DODGE CUMMINS GDP Twin CP-3 Big Line Kit

Rotary Cutter Drives Service Manual

Auto-Locking Pintle Hook

ComTrac Adjustable Speed Drives Electric Remote Control

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Push Trolley. Owner s Manual

Auto-Locking Trailer Coupler

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Read this entire manual before operation begins.

Guardian NV Flywheel Coupling

IMPORTANT SAFETY INSTRUCTIONS

Operating Instructions & Parts Manual. Air/Manual Hydraulic Bottle Jacks

Operating Instructions & Parts Manual. MagicLift Hydraulic Service Jack

DODGE USAF 200/300 Direct Mount Pillow Block Bearings

430B SERIES HORIZONTAL SPLIT CASE PUMP

DELHOIST DOUBLE ACTING TELESCOPIC CYLINDERS Stoney Rise Road (P.O. Box 20), Devonport, Tasmania 7310

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

Transcription:

2000HG NEW STYLE HELICAL GEAR RATIO MULTIPLIER INSTALLATION AND MAINTENANCE MANUAL May 4, 2017 Indianapolis, Indiana (800) 866-7973 e-mail: sales@sterlingelectric.com www.sterlingelectric.com

7997 Allison Avenue, Indianapolis, IN 46268 Website: www.sterlingelectric.com (800) 866-7973 FAX (317) 872-0907 email:sales@sterlingelectric.com 2000HG NEW STYLE HELICAL GEAR RATIO MULTIPLIER INSTRUCTION MANUAL SELECTION INFORMATION Read ALL instructions prior to operating unit. Improper maintenance or operation may cause injury to personnel or reducer failure. Written authorization from Sterling Electric is required to operate or use this unit in man lift or people moving devices. Check to make certain application does not exceed the allowable load capacities published in the current catalog. Buyer shall be solely responsible for determining the adequacy of the product for any and all uses to which buyer shall apply the product. The application by buyer shall not be subject to any implied warranty of fitness for a particular purpose. Information contained in this manual is considered correct at the time of publication and is subject to change without notice. SAFETY ALERT WARNING: WARNING: WARNING: WARNING: For safety, purchaser or user should provide protective guards over all shaft extensions and any moving apparatus mounted thereon. The user is responsible for checking all applicable safety codes in his area and providing suitable guards. Failure to do so may result in bodily injury and/or damage to equipment. Hot oil or gear units can cause severe burns. Use extreme care when removing lubrication plugs and vents. Make certain that the power supply is disconnected before attempting to service or remove any components. Lock out the power supply and tag it to prevent unexpected application of power. Any brakes that are used in conjunction with this unit must be sized or positioned in such a way as to not subject the unit to loads beyond the catalog rating. Test run unit to verify operation. If the unit tested is a prototype, that unit must be of current production. If the unit cannot be located in a clear and dry area with access to adequate cooling air supply, then precautions must be taken to avoid the ingestion of contaminants such as water and the reduction in cooling ability due to exterior contaminants. Units located in confined spaces may require forced air-cooling. 2

IMPORTANT INFORMATION In the event of the resale of any of the goods, in whatever form, Resellers/Buyers will include the following language in a conspicuous place and in a conspicuous manner in a written agreement covering such sale: The manufacturer makes no warranty or representations, expressed or implied, by operation of law or otherwise, as to the merchantability or fitness for a particular purpose of the good sold hereunder. Buyer acknowledges that it alone has determined that the goods purchased hereunder will suitably meet the requirements of their intended use. In no event will manufacturer be liable for consequential, incidental or other damages. Resellers/Buyers agree to also include this entire document including the warnings above in a conspicuous place and in a conspicuous manner in writing to instruct users on the safe usage of the product. This instruction manual should be read together with all other printed information such as catalogs, supplied by Sterling Electric. GENERAL OPERATION 1. Run the motor, which drives the unit, and check the direction of unit output rotation. Consult motor nameplates for instructions to reverse the direction of rotation. 2. Attaching the load: On direct-coupled installations, check shaft and coupling alignment between unit and loading mechanism. On chain/sprocket and belt/pulley installation, locate the sprocket or pulley as close to the oil seal as possible to minimize overhung load. Check to verify that the overhung load does not exceed specifications published in the catalog. 3. High momentum loads: If coasting to a stop is undesirable, a braking mechanism should be provided to the unit output or the driven mechanism. The system of connected rotating parts must be free from critical speed, torsional or other type vibration, no matter how induced. The responsibility for this system analysis lies with the purchaser of the speed reducer. INSTALLATION 1. Mount the unit using grade 5 or higher fasteners. 2. For shipment, solid plugs are installed in the unit along with a vent plug with transportation lock which is pre-installed assuming standard horizontal mounting (M1). The vent plug will need to removed and relocated if the unit is to be mounted in any positon other than the standard horizontal positon as shown in the chart under LUBRICATION. After the unit is mounted, completely remove the transportation lock from the vent plug as directed under VENT PLUG LOCATION. Failure to vent the unit can cause premature seal wear or loss of seal and oil. These conditions are not covered by warranty. Check for correct oil level. Contact the factory for level and vent recommendations on non-standard mounting positions. Do not operate the unit without making sure it contains the correct amount of oil. Do not overfill or underfill with oil, or injury to personnel, reducer or other equipment may result. 3

A unit cannot be used as an integral part of a machine superstructure which would impose additional loads on the unit other than those imposed by the torque being transmitted either through a shaft-mounted arrangement, and any shaft mounted power transmitting device. (e.g. sprockets, pulleys, couplings) For safe operation and to maintain the unit warranty, when changing a factory installed fastener for any reason, it becomes the responsibility of the person making the change to properly account for fastener grade, thread engagement, load, tightening torque and the means of torque retention.` LUBRICATION On ALL quill style input units with a motor mounted vertical shaft up or quill under on the input will require a double input seal arrangement to prevent leakage or C-face coupled style units should be used. Consult factory. All standard helical ratio multipliers ordered from the factory are shipped with standard compounded lubricant and is good for ambient temperature ranges of 30 F to 104 F. All washdown and stainless steel helical ratio multipliers ordered from the factory are shipped with synthetic NSF H1 Food Grade lubricant and are good for ambient temperature ranges of -10 F to 105 F. Double reduction units have separate oil sumps and must be filled and checked independently. Use of synthetics can cause problems if they are not compatible with the seals or conventional lubes they replace. Prior to startup, verify that the oil is at the level shown on the drawing below. If the ambient temperature will be outside the range for the lubricant installed at the factory, drain and refill the reducer with the proper viscosity lubricant prior to use. VENT PLUG LOCATION Washdown and stainless steel units are supplied with a Heinrichs Breather with a rubber transportation lock. The transportation lock must be completely removed before operation. Failure to do so may cause the unit to leak. See below. Before putting the unit into operation, it may be necessary to relocate the vent plug for positions other than standard (M1). Substitute the vent plug for the solid plug at the position desired. Install the solid plug in the location the vent plug was removed from. Refer to the following chart for the recommended vent plug locations based on mounting position. 4

M1 VENT/ LEVEL/ DRAIN LOCATIONS M2 M3 STANDARD POSITION M4 M5 M6 NOTE: The unit is filled at the factory with the proper amount of oil for the STANDARD mounting position. The level plug is for reference only so the unit can be checked for proper oil level prior to installation and start-up. All other mounting positions will require the oil level to be measured out prior to filling the unit based on the value in the table labeled OIL CAPACITIES below. On ALL quill style input units, cast iron and stainless with the input mounted vertical shaft up or input under will require a double input seal arrangement to prevent leakage or C-face coupled style units should be used. Consult factory OIL & WEIGHT SPECIFICATIONS RECOMMENDED LUBRICATION OIL (ISO 150) OIL CAPACITIES (FLUID OUNCE) Mineral Oil PAO Synthetic PAO Synthetic H1 56C/140TC 180TC/210TC Food Grade Mobilgear 600XP-150 Mobil SHC 150 Mobil Cibus 150 14 16 The use of PAG synthetics is not recommended. Change Intervals: Standard compounded lubricants should be changed every six months or 2500 operating hours, whichever comes first. Synthetic lubricants should be changed every two years or 6000 hours, whichever comes first. Oil should be changed more often if the unit is used in a severe environment. (i.e. dusty, humid) In the Food and Drug Industry (including animal food), consult the lubrication supplier for recommendation of lubricants which are acceptable to the Food and Drug Administration and/or other authoritative bodies having jurisdiction. 5

MAINTENANCE Your Sterling Electric unit has been tested and adjusted at the factory. Dismantling or replacement of components must be done by Sterling Electric to maintain the warranty. Frequently check the oil level of the unit. If oil level is low, (refer to the vent and level position chart) add proper lubrication through the filler plug until it comes out the oil level plug. Inspect vent plug often to insure it is clean and operating. Mounting bolts should be routinely checked to ensure that the unit is firmly anchored for proper operation. CLASS OF SERVICE All capacity ratings are based on American Gear Manufacturers Association (AGMA) Standards. Load conditions must be within cataloged ratings published in the current Sterling Electric Catalog (available upon request). LONG-TERM STORAGE (6 MONTHS UP) Units must be stored indoors, in a dry, warm temperature. Completely fill the unit with oil. Rotate the input shaft so that the output shaft rotates at least one revolution per month. Completely cover the input and output shaft with grease. At the time of start up, drain the storage oil, install the breather, and fill to the proper oil level with correct lubricant for the operating condition. WARRANTY (LIMITED) The warranty will cover all of the parts in the gearmotor or reducer unit for 12 months from the date of shipment. The warranty is only for parts and labor. In no event shall our liability exceed the original price of the unit, nor does it cover cost of on site repair, installation, or freight. Contact the service department for a complete explanation as to the full warranty policies and conditions of sale. All dimensions designs and specifications are subject to change without notice 6

SEAL AND BEARING SIZES Input Bearing Motor Bearing Part Number and Size Input Series OD (mm) ID (mm) Width (mm) Sterling P/N 56C/140TC 6206 62 30 16 400-0008-9 180TC/210TC 6206 62 30 16 400-0008-9 ODE Output Bearing Motor Bearing Part Number and Size Output Series OD (mm) ID (mm) Width (mm) Sterling P/N 56C/140TC 6305 62 25 17 400-0495-5 180TC/210TC 6305 62 25 17 400-0495-5 DE Output Bearings Motor Bearing Part Number and Size Input Series OD (mm) ID (mm) Width (mm) Sterling P/N 56C/140TC 6206 62 30 16 400-0008-9 180TC/210TC 6207 72 35 17 400-0009-7 Input Seal Motor Bearing Part Number and Size Input Shaft (mm) Bore (mm) Width (mm) Sterling P/N 56C/140TC (Item #4) 35 50 8 404-0292-8 56C/140TC (Item #15)* 35 62 7 404-0350-0 180TC/210TC (Item #21) 50 60 8 404-0377-3 180TC/210TC (Item #24)* 50 62 7 404-0452-8 *Only present on units with double input seal option. Output Seal Motor Bearing Part Number and Size Output Shaft (mm) Bore (mm) Width (mm) Sterling P/N 56C/140TC 30 50 7 404-0291-9 180TC/210TC 35 55 8 404-0294-6 7

56C/140TC PARTS Item Description Qty Item Description Qty No. No. 1 INPUT QUILL SHAFT 1 13 HEINRICHS BREATHER 1 2 BALL BEARING 2 14 SEAL PLUG 4 3 EXTERNAL SNAP RING 1 15 METRIC SEAL 1 4 METRIC SEAL 1 16 SPACER RING/ SPLASH GUARD 1 5 METRIC SEAL 1 17 SOLID OUTPUT GEAR 1 6 BALL BEARING 1 18 PINION 1 7 SOCKET HEAD CAP SCREW 10 19 SPACER 1 8 O-RING 1 20 SS2RBQ ONE PIECE HOUSING 1 9 METRIC KEY 1 21 C-FACE OUTPUT CAP 1 10 SLINGER 1 22 OUTPUT SHAFT 1 11 KEY 1 23* O-RING 1 12 INTERNAL SNAP RING 1 24 INPUT FLANGE 1 *Applies to Stainless Steel units only. 8

180TC/210TC PARTS Item Description Qty Item Description Qty No. No. 1 ONE PIECE HOUSING 1 14 C-FACE OUTPUT CAP 1 2 BALL BEARING 1 15 SOCKET HEAD CAP SCREW 6 3 EXTERNAL SNAP RING 1 16 OUTPUT SHAFT 1 4 BALL BEARING 1 17 BALL BEARING 1 5 SPACER 1 18 METRIC SEAL 1 6 O-RING 1 19 KEY 1 7 METRIC KEY 1 20 INPUT FLANGE 1 8 INTERNAL SNAP RING 1 21 INPUT QUILL SHAFT 1 9 HEINRICHS BREATHER 1 22 METRIC SEAL 1 10 SEAL PLUG 4 23 SOCKET HEAD CAP SCREW 4 11 PINION 1 24 V-SEAL 1 12 OUTPUT GEAR 1 25 METRIC SEAL 1 13 SPACER RING/ SPLASH GUARD 1 26* O-RING 1 *Applies to Stainless Steel units only. 9

Indianapolis, Indiana (800) 866-7973 e-mail: sales@sterlingelectric.com www.sterlingelectric.com 10