THE NEW TS IT RACK 8

Similar documents
It s as simple as A,B,C...

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

Rittal CM Compact System Enclosures

Make IT easy: Enclosure, power and cooling solutions

Plenty of space for intelligent solutions.

TS IT Server/Network Enclosures

Rittal CS New Basic enclosure

Outdoor system solutions

Rittal console systems...

The Rittal Flex-Block base/plinth system

TE 7000, Top Efficiency: the Global IT Rack. Uncompromisingly geared to the network task

Railway technology solutions

Product Data For FARNELL

More efficiency with the base/plinth system VX

Premium Quality - Value Price

Outdoor system solutions

348,6 HE = U Carrying handles, horizontal

Baying systems TS 8. Height: 1200 mm/1400 mm, depth: 500 mm

SCHÄFER IT-Systems The specialists for IT infrastructure

Knürr Smaract. Knürr Smaract. CompactRack

stainless steel Cover hinge The cover hinge is simply screwed to the box protection channel and to the edge fold. Model No. KL

Ripac Vario-Module System Enclosure

ACCESSORIES FOR SZE2 CABINETS

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

SPECIFICATION GUIDE-IMRAK

Product Data For FARNELL

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

The range is fully compatible with the PS system accessories.

LCU DX Efficient cooling with no loss of space

1. Varicon M Varicon M - Pre-assembled cabinets Varicon M - Frame Varicon M - Base Varicon M - Top 25

SCHÄFER IT-Systems The specialists for IT infrastructure

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit

Industrial Enclosures

Singular and rows of racks in steel and stainless steel, PC racks. Server and distribution rack systems, enclosures and housings

S2005 Cabinets DESIGNERS AND MANUFACTURERS OF 19 RACK SYSTEMS

Delta 3 rack system (DRS)

IMAGE. Flexible and Multi-Application Stand Alone 19 Cabinet.

19 Server Cabinets SOHO/SMB Networking

Rittal North American Industrial Buyer s Guide

GF-SERIES GLOBALFRAME CABINET SYSTEM

Rack Intelligent server and network rack solutions for your data centre

Product Information RiCase

TS 8 Specification Guide

Pixus Technologies Catalog

IMRAK Freestanding Cabinets

GF-SERIES GLOBALFRAME GEN 2 CABINET SYSTEM

SC Series Cabinets and Accessories SC SERIES PRE-CONFIGURED CABINETS. V3 and V4

Access rack system (ARS)

VERAK EMC. 19 Stand Alone Cabinet with Radio Frequency Protection.

Rittal RiLine60. The fascinating 60 mm system of the future assembly-friendly, time-saving, individual and modular. including.

NOVASTAR FRAME TOOLSET

19 floor rack with steel door

Delta 3 rack system (DRS)

Summary for CLM-232XX-XX Series

INTRODUCTION WALL MOUNT APPLICATIONS SLIMLINE BOX... 5 COMMSRAK... 5 IMRAK IMRAK

IN STAINLESS STEEL: Compact enclosures Enclosures and support arm systems for the human/machine interface Large enclosures

SPECIFICATION GUIDE-IMserv

IMRAK. The 19 Stand Alone Cabinet.

IP Rated, Custom-built & UK Assembled Cabinets

Innovative and Efficient SCHÄFER IT Rack Solutions. Quality made in Germany

Pixus Technologies Catalog

ARION: 19 EIA-310E Standard Enclosure

Pixus Technologies Catalog

Our expertise your benefit. AE Available off the shelf.

TS 8 Bayed Enclosure System

Technical System Catalogue Operating housings with handle strips

Rittal TopTherm fan-and-filter unit

19 floor rack with steel door

Cabinets PROLINE. Modifications. Overview Cabinets Climate Control Cases Subracks/ 19" chassis Modules...

any server any environment one source

Data sheet. Server Rack ( heavy duty rack cabinet ) W:800 = D:1000

Network technology Universal network cabinets and enclosures for network technology solutions

LED system light Sensationally bright

Hygienic Design. 1.5 Hygienic Design

USpace Midi Cabinet & Midi Server Cabinet Range.

Cabinet and wall-mounted case accessories

Hi-Tech specially designed components allow for fast and easy assembly.

NEW. Rittal RiLine60 UL 508. The fascinating 60 mm system of the future

Frequently Asked Questions

varioflex 19 network & server cabinets, 600, 800 mm width - 600, 800, 1000 mm depth

V-LINE Cabinet Systems

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

networking datacoms telecoms electro/electronics

SE 8 Delivers Greater Durability and Customization Over Unibody Enclosures

Installation and Operating Instructions

E NUX RACK 19 AND NETWORKING SOLUTIONS FEATURES AND BENEFITS

GT-Series GlobalFrame Gen 2 Cabinet System

VEROTEC. Electronics Packaging. 19 Racks and Accessories

IMRAK. The 19 Stand Alone Cabinet.

2 The Isle of Cold Server enclosures. outdoor enclosure

KNÜRR DCM. Modular rack platform for future-proof data centers

VEROTEC Electronics Packaging

F-SERIES TERAFRAME CABINET SYSTEM 23.6 W (600 mm) Cabinets


XL Distribution enclosures WORKSHOP SPECIFICATIONS

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8

Table Top Rack Cabinets (RCHS Series) - HEAVY DUTY. Features:

Elegant-wall 19inch wall mounting rack cabinet W:600 = D:600

Rittal TopTherm chiller

Modular Enclosure Solutions RACK IQ - ENTERPRISE & HYPERSCALE DATA CENTER CABINETS

Transcription:

THE NEW TS IT RACK 8

Fast and reliable Fast Loosen the 48. (9 ) quickrelease fastener, slide into the correct position, and latch Reliable Maximum load capacity up to,000 N Convenience in perfection Interior installation Side offset and alternative mounting dimensions easily achieved Distance between levels Direct determination with integral pitch pattern U labelling May be read from the front and rear Convincing door concept Glazed door or vented door Doors with 80 hinges and comfort handles, prepared for individual locks Divided rear door for space-optimised positioning Optimised air throughput With open surface area 8% perforated Multi-functional roof Brush strips for cable entry across the entire enclosure depth Cable clamping directly behind the brush strip Fan mounting plate with cut-out for active and passive climate control 9

THE NEW TS IT RACK 0

Tool-free installation Tool-free installation of all slide rails, component shelves, telescopic slides and much more Simply locate into the rear mounting angle, extend to the required size, and secure at the front Quick-assembly side panel Divided side panel for simple one-man assembly Locate side panel at the top, slot in at the bottom, snap shut and it s done. No screw-fastening required Quick-release fasteners with integral lock additional with internal latch for increased security Built-in added value Prepared for Dynamic Rack Control or cable management Ready to use for space-saving, clip-on mounting of the Rittal PDU busbar; on both sides in the zero-u space between the mounting angle and side panel Maximum energy efficiency thanks to compartmentalisation with maximum flexibility Fully suitable for rack/suite and room cooling Variable termination at the sides with all-round brush strip U mounting space additionally integrated into the compartmentalisation

Page 7 Glazed door: Single-pane safety glass, 3 Enclosure frame, interior installation: Dipcoat-primed Doors and roof: Dipcoatprimed, powder-coated Frame and enclosure panels: RAL 703 Interior installation: RAL 900 Product-specific supply scope, see table. Load capacity of the 48. (9 ) mounting level:,000 N Distance between levels as delivered: Depth < 800: 4 Depth > 000: 74 Approvals: UL/cUL Detailed drawings: Available on the Internet. With glazed door for rack climate control U 4 4 38 4 4 Page Width 800 800 800 800 800 Height 00 00 800 000 000 Depth 800 000 800 00 800 Glazed aluminium door at the front (80 ), with comfort handle for semi-cylinder and security lock 34 E door at the rear (80 ), with comfort handle for semi-cylinder and security lock 34 E door at the rear (80 ), vertically divided, with comfort handle for semi-cylinder and security lock 34 E 48. (9 ) mounting level at the front and rear, on depth stays with quick-release fasteners, depth-variable Roof plate, multi-piece, removable, with side cable entry in the depth and covered cut-out for fan mounting plate ) 03.0 04.0 0.0 0.0 07.0 Included with the supply, not pre-installed Spacers for passive cooling 4 Earthing set with central earthing point set Multi-tooth screws M, cage nuts M, conductive 0 Side panels -part x 0.000 x 0.00 x 0.00 0 -part 87.3 87.3 7 ) Base mount 0.30 0.30 0.30 0.300 0.30 0 Gland plates, modular see from page Base/plinth see Catalogue 33, page 4 Fan mounting plate for TS IT including thermostat 0.00 0.00 0.00 0.00 0.00 Air baffle plate set 0.8 0.8 Cable route 0.0 0.0 3 Cable duct 0.0 0.0 Component shelves see from page Slide rails see from page Cable clamp rails, C rails, punched sections with mounting flanges see Catalogue 33, from page 44 Cable shunting ring see Catalogue 33, from page 74 Cable management panel see page 4 Power distribution unit PDU see page 9 Included with the supply. ) Cable entry, rear. ) See Catalogue 33. Rittal Innovations 0

With glazed door for rack climate control U 4 4 4 4 47 Width 00 800 00 800 800 Height 000 000 000 000 00 Depth 000 000 00 00 800 Glazed aluminium door at the front (80 ), with comfort handle for semi-cylinder and security lock 34 E door at the rear (80 ), vertically divided, with comfort handle for semi-cylinder and security lock 34 E 48. (9 ) mounting level at the front and rear, on depth stays with quick-release fasteners, depth-variable Roof plate, multi-piece, removable, with side cable entry in the depth and covered cut-out for fan mounting plate 4 08.0 09.0 0.0.0.0 TS IT Included with the supply, not pre-installed Spacers for passive cooling 4 Earthing set with central earthing point set Multi-tooth screws M, cage nuts M, conductive 0 Side panels, -part x 0.030 x 0.030 x 0.040 x 0.040 x 0.00 0 Base mount 0.30 0.30 0.30 0.30 0.30 0 Gland plates, modular see from page Base/plinth see Catalogue 33, page 4 Fan mounting plate for TS IT including thermostat 0.00 0.00 0.00 0.00 0.00 Air baffle plate set 0.80 0.8 0.80 0.8 0.83 Cable route 0.0 0.0 0.0 0.0 0.0 3 Cable duct 0.0 0.0 0.4 Component shelves see from page Slide rails see from page Cable clamp rails, C rails, punched sections with mounting flanges see Catalogue 33, from page 44 Cable shunting ring see Catalogue 33, from page 74 Cable management panel see page 4 Power distribution unit PDU see page 9 Included with the supply. Rittal Germany RITTAL GmbH & Co. KG Postfach D-37 Herborn Phone: +49(0)77 0-0 Fax: +49(0)77 0-39 E-mail: info@rittal.de www.rittal.com Rittal Innovations 0 3

Page 7 Enclosure frame, interior installation: Dipcoat-primed Doors and roof: Dipcoatprimed, powder-coated Frame and enclosure panels: RAL 703 Interior installation: RAL 900 Product-specific supply scope, see table. Load capacity of the 48. (9 ) mounting level:,000 N Distance between levels as delivered: 74 Approvals: UL/cUL Detailed drawings: Available on the Internet. With vented door for room climate control U 4 4 4 4 4 Page Width 800 00 800 00 800 Height 00 000 000 000 000 Depth 000 000 000 00 00 door, vented ), at the front (80 ), with comfort handle for semi-cylinder and security lock 34 E door, vented ), at the rear (80 ), with comfort handle for semi-cylinder and security lock 34 E door, vented ), at the rear (80 ), vertically divided, with comfort handle for semi-cylinder and security lock 34 E 48. (9 ) mounting level at the front and rear, on depth stays with quick-release fasteners, depth-variable Roof plate, multi-piece, removable, with side cable entry in the depth and covered cut-out for fan mounting plate 04.0 08.0 09.0 0.0.0 Included with the supply, not pre-installed Spacers for passive cooling 4 Earthing set with central earthing point set Multi-tooth screws M, cage nuts M, conductive 0 Side panels -part x 0.030 x 0.030 x 0.040 x 0.040 0 -part 87.3 7 ) Base mount 0.30 0.30 0.30 0.30 0.30 0 Gland plates, modular see from page Base/plinth see Catalogue 33, page 4 Fan mounting plate for TS IT including thermostat 0.00 0.00 0.00 0.00 0.00 Air baffle plate set 0.80 0.8 0.80 0.8 Cable route 0.0 0.0 0.0 0.0 3 Cable duct 0.0 0.0 Component shelves see from page Slide rails see from page Cable clamp rails, C rails, punched sections with mounting flanges see Catalogue 33, from page 44 Cable shunting ring see Catalogue 33, from page 74 Cable management panel see page 4 Power distribution unit PDU see page 9 Included with the supply. ) Vented surface area approx. 8% perforated. ) See Catalogue 33. 4 Rittal Innovations 0

With vented door for room climate control TS IT U 47 47 47 47 Page Width 00 800 00 800 Height 00 00 00 00 Depth 000 000 00 00 door, vented ), at the front (80 ), with comfort handle for semi-cylinder and security lock 34 E door, vented ), at the rear (80 ), vertically divided, with comfort handle for semi-cylinder and security lock 34 E 48. (9 ) mounting level at the front and rear, on depth stays with quick-release fasteners, depth-variable Roof plate, multi-piece, removable, with side cable entry in the depth and covered cut-out for fan mounting plate 3.0 4.0.0.0 Included with the supply, not pre-installed Spacers for passive cooling 4 Earthing set with central earthing point set Multi-tooth screws M, cage nuts M, conductive 0 Side panels, -part x 0.00 x 0.00 x 0.070 x 0.070 0 Base mount 0.30 0.30 0.30 0.30 0 Gland plates, modular see from page Base/plinth see Catalogue 33, page 4 Fan mounting plate for TS IT including thermostat 0.00 0.00 0.00 0.00 Air baffle plate set 0.8 0.83 0.8 0.83 Cable route 0.0 0.0 0.0 0.0 3 Cable duct 0.4 0.4 Component shelves see from page Slide rails see from page Cable clamp rails, C rails, punched sections with mounting flanges see Catalogue 33, from page 44 Cable shunting ring see Catalogue 33, from page 74 Cable management panel see page 4 Power distribution unit PDU see page 9 Included with the supply. ) Vented surface area approx. 8% perforated. Rittal Great Britain RITTAL Limited Braithwell Way Hellaby Industrial Estate Hellaby Rotherham S Yorks S 8QY Phone: +44 (0) 709 704000 Fax: +44 (0) 709 707 E-mail: information@rittal.co.uk www.rittal.co.uk Rittal Innovations 0

Gland plate for TS IT Potential equalisation is provided via assembly components and earthing points. Gland plate set To conceal the entire base opening. Gland plate modules Select suitable gland plates depending on the application. Zinc-plated Assembly parts. : Clips for gland plates, see Catalogue 33, page 9. For enclosure depth 00 For enclosure width Required A Gland plate set 00 800 packs Gland plate, solid with sliding panel, multi-piece set 0.0 Gland plate modules Required packs For enclosure width 00 800 B module plate as selected Gland plate, depth 0 00.8 00.9 Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 C Cable entry, rear or front Gland plate, depth 00 00.4 00. Sliding panel, depth 0 00.39 00.40 Self-adhesive foam cable clamp strip 3 m 73.000 73.000 D Cable entry, centre Gland plate, depth 00 00.4 00. Sliding panel, depth 0 00.39 00.40 Section for cable entry, centre set 880.00 880.080 A B C 7 3 D 3 3 8 3 4 7 8 Gland plate, depth 0 Gland plate, depth 0 Gland plate, depth 00 Gland plate, depth 0 Sliding panel, depth 0 Module plate, depth 37. Foam rubber cable clamp strip Section for cable entry, centre Also required: Base mount, see page 0. Rittal Innovations 0

For enclosure depth 800 For enclosure width Required A Gland plate set 00 800 packs Gland plate, solid with sliding panel, multi-piece set 0.30 Gland plate modules Required packs For enclosure width 00 800 B module plate as selected Gland plate, depth 0 00. 00.3 Gland plate, depth 00 00.4 00. Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 C module plates as selected Gland plate, depth 00 00.8 00.9 Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 D Cable entry, rear or front Gland plate, depth 0 00. 00.3 Gland plate, depth 0 00.8 00.9 Sliding panel, depth 0 00.39 00.40 Self-adhesive foam cable clamp strip 3 m 73.000 73.000 E Cable entry, centre Gland plate, depth 0 00. 00.3 Gland plate, depth 0 00.8 00.9 Sliding panel, depth 0 00.39 00.40 Section for cable entry, centre set 880.00 880.080 A B C D E 3 3 3 7 8 3 4 7 8 Gland plate, depth 0 Gland plate, depth 0 Gland plate, depth 00 Gland plate, depth 0 Sliding panel, depth 0 Module plate, depth 37. Foam rubber cable clamp strip Section for cable entry, centre Also required: Base mount, see page 0. Rittal Innovations 0 7

For enclosure depth 000 For enclosure width Required A Gland plate set 00 800 packs Gland plate, solid with sliding panel, multi-piece set 0.40 0.0 Gland plate modules Required packs For enclosure width 00 800 B module plate as selected Gland plate, depth 0 00. 00.3 Gland plate, depth 0 00.0 00. Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 C module plates as selected Gland plate, depth 0 00. 00.3 Gland plate, depth 00 00.4 00. Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 D Cable entry, rear or front Gland plate, depth 0 00. 00.3 Gland plate, depth 00 00.4 00. Sliding panel, depth 0 00.39 00.40 Self-adhesive foam cable clamp strip 3 m 73.000 73.000 E Cable entry, centre Gland plate, depth 0 00. 00.3 Gland plate, depth 00 00.4 00. Sliding panel, depth 0 00.39 00.40 Section for cable entry, centre set 880.00 880.080 A B C D E 4 3 7 8 3 4 7 8 Gland plate, depth 0 Gland plate, depth 0 Gland plate, depth 00 Gland plate, depth 0 Sliding panel, depth 0 Module plate, depth 37. Foam rubber cable clamp strip Section for cable entry, centre Also required: Base mount, see page 0. 8 Rittal Innovations 0

For enclosure depth 00 TS IT For enclosure width Required A Gland plate set 00 800 packs Gland plate, solid with sliding panel, multi-piece set 0.0 0.70 Gland plate modules Required packs For enclosure width 00 800 B module plate as selected Gland plate, depth 0 3 00. 00.3 Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 C module plates as selected Gland plate, depth 0 00. 00.3 Gland plate, depth 0 00.0 00. Sliding panel, depth 0 00.39 00.40 Module plate, depth 37. Vented with airflow regulator 78.3 78.38 Cable entry with brush strip 78.3 78.38 Vented 78.30 78.380 Cable entry with brush strip, super-airtight 78.37 78.387 Cable entry, side 78.388 D Cable entry, rear or front Gland plate, depth 0 00. 00.3 Gland plate, depth 0 3 00.8 00.9 Sliding panel, depth 0 00.39 00.40 Self-adhesive foam cable clamp strip 3 m 73.000 73.000 E Cable entry, centre Gland plate, depth 0 00. 00.3 Gland plate, depth 0 3 00.8 00.8 Sliding panel, depth 0 00.39 00.40 Section for cable entry, centre set 880.00 880.080 A B C D E 7 4 8 3 4 7 8 Gland plate, depth 0 Gland plate, depth 0 Gland plate, depth 00 Gland plate, depth 0 Sliding panel, depth 0 Module plate, depth 37. Foam rubber cable clamp strip Section for cable entry, centre Also required: Base mount, see page 0. Rittal Innovations 0 9

Base mount To accoodate gland plate modules. Tool-free mounting or screw-fastening Easily retroffitted and combined with stabiliser Spray-finished RAL 703 mounting rails including assembly parts. For enclosure depth 00 0.300 800 0.30 000 0.30 00 0.30 Side panel, divided Easy handling and tool-free assembly Quick-release fastener including security lock 34 E Internal latch included (no key required) Lock with chassis, cable clamp rail may be top-mounted on the outer mounting level Suitable for IT climate control and rack extinguishing Spray-finished RAL 703 console pedestal Earth conductor Assembly parts For enclosures Height Depth 800 800 0.000 000 00 0.00 000 800 0.00 000 000 0.030 000 00 0.040 00 800 0.00 00 000 0.00 00 00 0.070 Tubular door frame for rear door, vertically divided, solid Zinc-plated Assembly parts. For enclosures Width Height 00 000 set 0.00 800 000 set 0.0 Note: Required for use of the automatic door opener. 0 Rittal Innovations 0

Fan mounting plate For active ventilation of the TS IT. For use in the cut-out integrated into the roof plate. The unit may optionally be extended with additional fans. Technical specifications for one fan: Fan expansion kit, DK 7980.000, see Catalogue 33, page 404. Technical specifications of thermostat: Rated operating voltage: 0 V Temperature range: + C to + C RAL 703 Fan unit fans thermostat Open connection cable Assembly parts Note: Connection via distributor box or country-specific connector. : Fan expansion kit, see Catalogue 33, page 404. W x D Number of pre-wired fans Possible number of fans 800 x 00, 00 x 000, 00 x 00 3 0.00 800 x 800, 800 x 000, 800 x 00 0.00 Component shelf, U, static installation 48. (9 ) For mounting between 48. (9 ) mounting angles. Load capacity: kg surface load, static Spray-finished RAL 900 Assembly parts. Component shelf depth 0 set 0. 400 set 0. Component shelf, depth-variable 48. (9 ) for TS IT, L-shaped mounting angles, 48. (9 ) mounting frame For static installation between two 48. (9 ) mounting levels. Depth-variable to adapt to individual distances between levels Tool-free, time-saving one-man assembly Spray-finished RAL 900 Assembly parts. Distance between levels Load capacity, static kg Height U Packs of Model No. DK 400 00 0 / set 0. 00 900 0 / set 0. 400 00 00 set 0.9 00 900 00 set 0.70 Rittal Innovations 0

Component shelf, pull-out 48. (9 ) for TS IT, L-shaped mounting angles, 48. (9 ) mounting frame For mounting between two 48. (9 ) mounting angles. Depth-variable to adapt to individual distances between levels Tool-free, time-saving one-man assembly from the enclosure front Self-locking Fully extendible Spray-finished RAL 900 Installation kit Telescopic slide with mounting kit Assembly parts Distance between levels Load capacity, static kg Height U Depth Packs of Model No. DK 400 00 0 00 set 0.7 00 900 0 700 set 0.8 400 00 00 / 00 set 0.7 00 900 00 / 700 set 0.7 Cable duct for TS IT, DK-TS, TE High packing density due to U-based cable routing Removable duct cover hinged on both sides Optional cable holders may be used (DK 787.330, see Catalogue 33, page 78) Suitable for back-to-back baying Simple assembly with tool-free quick-release fastening Alternatively suitable for screw-fastening, plastic UL 94-V0 RAL 900 Cover and assembly parts. For enclosure height U 000 3 0.0 00 4 0.4 Cable finger U for TS IT For U-based cable routing Simple, tool-free assembly Cable routing possible in conjunction with air baffle plates Plastic, UL 94-V0 RAL 900 4 0. Rittal Innovations 0

Cable manager For system-compatible cable deflection while complying with minimal bending radii and to accoodate surplus cables and excess length. The elements may optionally be used individually or in combination for cable routing. They may be combined into semi-circular or circular elements. Supports use on corners and edges to allow protected cable routing around them. Mounting clips for use above the arc hold the routed cables back within the elements. The elements are also bayable in an axial direction to allow U-based cable routing to the mounting level, or channelling of the cable sections. Plastic, UL 94-V0 RAL 900 Mounting clips and assembly parts. 0 0.40 44 0 7 0 7 Cable route For cable clamping and routing with network and server applications Mounting across the entire depth with 800 width, mounting only behind the second 48. (9 ) pair of mounting angles with 00 width Tool-free quick assembly Alternatively suitable for screw-fastening Multi-functional punchings for cable management accessories RAL 900 Height 000 00 0.0 : Cable ties, nylon tape, see Catalogue 33, page 70 Shunting rings, see Catalogue 33, from page 73 Cable routing bars, see Catalogue 33, page 77 Nylon tape supports For simple, fast cable attachment Tool-free mounting in the system punchings with 0. x., with a quarter rotation Direct use on the horizontal TS section, on the support strips and mounting angles of the 48. (9 ) interior installation on the cable route or on punched sections with mounting flanges. Length of nylon tape: 400 Plastic 0 supports including nylon tape 0 0. Rittal Innovations 0 3

System supports for cable routes for TS IT The depth-variable support system may be attached to all 800 00 deep TS enclosures with external screw-fastening of the roof plate. The integral system punchings, for screws or cage nuts, support the attachment of most coon cable route systems. May be combined with TS IT fan mounting plate In combination with punched rail, suitable for accoodating additional cable guide rails or pipelines Powder-coated RAL 703 783.47 : Metal multi-tooth screws. x 3, SZ 48.00, see Catalogue 33, page. Cage nuts M, TS 8800.340, see Catalogue 33, page. Cable management panel 48. (9 ) For horizontal management of the patch cables, with cable shunting rings. Panel: Ring: Steel Ring: Zinc-plated RAL 900 U Ring size 43 x 0.0 43 x 0 77.00 8 x 77.0 Cable management panel with cable routing bars 48. (9 ) For horizontal management of the patch cables with cable routing bars. Opening the individual cable routing bars allows user-friendly modification and extension of the cabling. Panel:, spray-finished Cable routing bars: Plastic Panel: RAL 900 Cable routing bars: Black U Bar depth No. of bars/ U Packs of Model No. DK approx. 80 0. 4 Rittal Innovations 0

Cable management panel, U 48. (9 ) The cable routing chamber has cut-outs from above, into which the patch cables can be inserted. The cable management panel is equipped with a flap and quick-release fasteners at the front, for optimum access to the cables. From the rear, the cables can be inserted via a cut-out with brush strips. With accoodation facility for cable clamp straps DK 70.000 or DK 7.000. RAL 900 U Depth 8 0.3 : Cable clamp straps, see Catalogue 33, page 7. Cable routing channel 48. (9 ) To hold the patching cables. RAL 900 U Depth 8 0.4 Cable entry panel 48. (9 ) Cut-out 390 x 40 ( U) or 390 x 0 ( U) with brush insert. With accoodation facility for cable clamp straps DK 70.000 or DK 7.000. RAL 900 U 0. 0. : Cable clamp straps, see Catalogue 33, page 7. Drawer, U, 3 U for a 48. (9 ) attachment level For front attachment to mounting angles, 48. (9 ). With cover and telescopic slides to accoodate assignment lists, operating manuals and small parts. The small version of the U variant is also suitable for mounting inside a swing frame. RAL 900 Fully assembled, including assembly parts. Height Clearance openings Width Depth Installation depth Packs of Model No. DK U 4 49 47 0.30 3 U 4 49 47 0.3 Rittal Innovations 0

Air baffle plate for TS IT To separate the hot/cold zones within an enclosure with aisle containment or when using an LCP system With all-round brush strip for collision-free shielding with installed bar systems on the outer mounting level For width 800, U blanking panel additionally included, plastic UL 94-V0 Spray-finished Assembly parts. Width x height Packs of 00 x 000 set 0.80 800 x 000 set 0.8 00 x 00 set 0.8 800 x 00 set 0.83 Slide rails, static installation for TS IT For mounting between 48. (9 ) mounting angles. System punchings for mounting accessories and cooling active components Technical specifications: Load capacity: 30 kg, static Zinc-plated Assembly parts. Length 0 0.400 Slide rails, static installation for TS IT For mounting between a front and a rear pair of mounting angles. To support heavy installed equipment. Side system punchings for mounting accessories and cooling components that expel to the side Simply locate into the system punchings of the TS IT Technical specifications: Load capacity: 80 kg, static Zinc-plated Assembly parts. Distance between 48. (9 ) levels 34 0.40 44 0.40 4 0.430 4 0.440 74 0.40 Rittal Innovations 0

Depth-variable slide rails 48. (9 ) for TS IT, L-shaped mounting angles, 48. (9 ) mounting frame For mounting between a front and a rear pair of mounting angles. To support heavy installed equipment. To adapt to individual distances between levels Tool-free, time-saving one-man assembly from the enclosure front All three mounting holes in the EIA system punchings are available for screw-fastening the equipment Zinc-plated Assembly parts. Distance between 48. (9 ) levels Load capacity kg Model No. DK 400 00 80 0.40 00 900 0 0.480 Cover, magnetic For optionally covering the front system punchings in the event of complete air blocking of the front, or in the absence of installed cable fingers or dynamic rack control strip. Length m Packs of 0.89 PSM mounting kit for TS IT For tool-free mounting of the PSM busbar on the horizontal TS 8 frame Orientation of the PSM busbar either to the enclosure centre or to the rear, zinc-plated Assembly parts. set 78.09 Rittal Innovations 0 7