PNEUMATICS / HYDRAULICS Test Equipment For Supplemental Cooling System A350 >SCST1<

Similar documents
PNEUMATICS / HYDRAULICS Test Equipment For Supplemental Cooling System A350 >SCST1<

HYDRAULICS Hydraulic Ground Power Unit - Mainline Aircraft 3000psi and 5000psi >Hgpu<

Hydraulic Test Equipment For A350 (Pre-Fal) >HTE350<

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Test Stand For Air Turbine Starters >TATS4<

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

CWP-CO / CWP-RC / CWP-HP 02 to 35

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Clamping and drive module

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

Oil-free Portable Compressors

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

Mobile Filtration Systems SMFS-P and SMFS-U

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

TZIM. Electropneumatic Analog Positioner 10/ EN

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

AIRBUS A350 EQUIPMENT CATALOGUE

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Technical Details Coiler head / spool diameter Spool weight (depending on type of spool winding axle)

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Hydraulic Caliper Disc Brakes SF Series

Technical specification. Cold milling machine W 35

techünert ESCALATOR PASSENGERSTAIR

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

MOBILAIR M 350. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm)

Technical specification. Stabilizer WR 2000 XL

FLEXIROC T45. Surface drill rig for quarrying and construction. Folding boom Hole diameter: mm (3½" 5")

Reliable fuel effi cient engines. Energy effi cient compressor rotor design built to close engineering tolerances.

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

FLEXIROC T45. Surface drill rig for quarry and construction. Folding boom Hole diameter: mm (3½" 5")

seated 4,500 2,000 2,000 6,579 9,891 / 1,188 2,779 / 3, x 16 x 12pr 7.00 x 12 x 14pr 7.00 x 12 x 12pr 1,282 1,140 1,140 8 / 10 2,220

VT Oil-Free Range Operators Handbook

Providing a constant temperature control and high cooling efficiency.

Rittal TopTherm chiller

ADN-W L 10. Battery Charger. Instruction manual

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

PORTABLE LUBRICATION MANAGEMENT CATALOG. ForFluids.com

A resiliant clamping solution for modern machine tool applcations.

50DF/60DF/70DF-7. Dimension. Specification. HYUNDAI DIESEL FORKLIFT TRUCKS Applied Tier 3 Engine PLEASE CONTACT

ABB component drives ACS150, 0.5 to 5 Hp

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

Centrifugal pumps. Main catalogue.

ITW GSE 2400 COMPACT GPU kva solid-state GPU

Feed Pumps Direct Drive Series 1.1.

A E R Z E N S C R E W C O M P R E S S O R S

n Photo may include optional equipment HYUNDAI LPG FORKLIFT TRUCKS - Applied Tier 4 Engine 35L/40L/45L/50L-7A

Product Data Sheet 632 NU-006

ProduCTS.

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Robbins 91/123. Large-size raise boring machines for holes ranging from 2.4 to 6.0 m (8-20 ft.) in diameter

NDR Series Rotor Pack

500 / 630 / 720 / 760 / 800 / 850 / 900

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

Oil/Air Cooler Units

SPINN Series 2,2 to 11 kw. Compressed air at your service

MIXING CENTRE FOR DELIVERY OF CELLULAR CONCRETE

Hydraulic Caliper Disc Brakes SF Series

A E R Z E N S C R E W C O M P R E S S O R S

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

Recirculating Coolers

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

Dry Ice Blasting Unit

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Servicing. Table of Contents

Mobile diesel tank systems: DT-Mobile Easy

Radial piston pump PR4 series 1X

Solar inverter AX-series

CB 3. High-quality control system. Built-in high pressure pump. Express wash for higher vehicle throughput. Water saving mode

5.2 Terminal Operations - Turnaround Station. 5.3 Terminal Operations - En Route Station. 5.4 Ground Servicing Connections

UM 045 UMPC 045 Oil service - simple, quick and compact with integrated particle monitor

Master Plus kva

Product Data Sheet DV5214 NU

ROBBINS 53RH C. Low-profile raise drill for holes ranging from 1.2 to 2.4 m (4-8 ft.) in diameter

BETA Switching Switches and Light Indicators

ORION PLUS three-phase kVA

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

DeltaBase 540 Technical Data Sheet

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

1/8 Ton J Series. Ship Loose Options: UL 1995 certification 18 month parts & labor warranty 24/7 service & support

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Mobile Column Lift EHB 707 Standard

Breakers. Make an Impact.

Integrated temperature test and calibration bench Model CBS-SC4000

Renewal of power lines. The work involves erecting new poles, attaching power lines with the help of a lift, and removing old poles.

Panelboards & Motor Starters

BRASS AIR FITTINGS: E-01 RYCO BLOW GUNS BRASS AIRLINE TYRE INFLATORS REGULATORS OETIKER COUPLINGS

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

MOBILAIR M 20. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 2.0 m³/min (71 cfm)

NCF fans 60Hz. Protection class IP 55

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions

Transcription:

PNEUMATICS / HYDRAULICS Test Equipment For Supplemental Cooling System A350 Device-Fill/Drain, SCS >SCST1-FD< and >SCST1-FD-D< Kit-Adapter GSP, SCS350 >SCST1-AK350GSP< Kit-Adapter CU, SCS350 >SCST1-AK350CU< Handpump-Topup, SCS >SCST1-TU< AIRBUS CERTIFIED For fully-automatic filling, draining, bleeding, replenishing and emptying of the Supplemental Cooling System (SCS) on the AIRBUS A350. > Simple handling > SCS system of the A/C automatically turns to maintenance mode ATA Chapter 21 World-wide universal connection (compatible with multiple voltages) > Exactly planned service time > Minimizes service time > For hangar and outdoor application v 1.0 Page 1 / 9

Device-Fill/Drain, SCS >SCST1-FD< And >SCST1-FD-D< PURPOSE > The equipment is developed for the following purposes: - Fill of Whole System - Drainage of Whole System - Top Up of Accumulator - Top Up and Drainage of Small ACU - Top Up and Drainage of SCS Chiller - Top Up and Drainage of VCRU GENERAL INFORMATION > User friendly ergonomic setup and easy operation via display and buttons > Interruption of service tasks with re-entry possible (replenishing with nitrogen) > Safe and trouble-free operation also in case of extreme environmental conditions > Connection to the A/C or their components in connection with the adapter kits >SCST1-AK350CU< and >SCST1-AK350GSP< ADDITIONAL INFORMATION > All preparation tasks for the Device-Fill/Drain, SCS can be carried out before the actual application on the A/C > Easy maintenance via hinged or removable covers > Equipped for the transport by forklift > Compact and robust design - double-axis-chassis with steering axle and towing bar > Spring-loaded chassis available as an option, recommended for long towing distances > Mechanic safety brake, also for use without towing vehicle MIDA/BEKO Page 2 / 9

TECHNICAL DATA > Hydraulic parameters: > Nitrogen supply (requirements): Flow: max. 50l/min, max. 6.5bar abs. (max. 13.2gal/min, max. 94psi abs.) Input: min. 20bar (min. 290psi) (external supply) > Medium: > Nitrogen connections: Propylen Glycol Water (according to AIRBUS specification) (not included in the scope of delivery) - AN4-8S - AN6 - Schrader > Reservoir volume: > Dimensions: Main-Reservoir: approx. 180l (47gal) Drain-Reservoir: approx. 190l (50gal) Sub-Reservoir: approx. 25l (6.6gal) > Operating conditions: Length: Width: Height: 3,400mm (133.8in) (tow bar folded up) 4,400mm (173.2in) (tow bar folded down) 1,350mm (53.2in) 1,600mm (63.0in) Ambient temperature: -30 to +50 C (-22 to +122 F) Storage temperature: -30 to +60 C (-22 to +140 F) Rel. air humidity: 5 to 90% (non-condensing) Page 3 / 9

TYPE SPECIFIC TECHNICAL DATA >SCST1-FD< >SCST1-FD-D< > Electrical supply (requirements): > Electrical supply (requirements): Mains connection:3/pe AC 50/60Hz 380-480V Nominal current: 23.8A Performance: 16.5kVA Back-up fuse: 32A gg Mains connection:3/pe AC 50/60Hz 380-480V Nominal current: 23.8A Performance: 16.5kVA Back-up fuse: 32A gg > Noise emission at the rear of the device: > Diesel generator set: - Operation by means of the electrical supply: max. 60.5dB(A) in 1m (39in) distance > Weight: Performance: 20HP / 14.7kW Cubic capacity: 997ccm Rotational speed:3,000rpm Consumption: approx. 4.5l/h (1.2gal/h) (at full load) Tank content: 7.0l (1.8gal) approx. 1,200kg (2,646lb) > Noise emission at the rear of the device: - Operation via electrical supply: max. 60.5dB(A) in 1m (39in) distance - Operation via diesel generator set: max. 81.5dB(A) in 1m (39in) distance > Weight: approx. 1,300kg (2,866lb) >SCST1-FD< >SCST1-FD-D< Page 4 / 9

STANDARD SCOPE OF DELIVERY > 2 EA hoses 15m (49ft) for the connection to the aircraft (1x FILL, 1x DRAIN) > 1 EA AC / GSE interconnection cable 15m (49ft) > 1 EA grounding cable to establish potential equalization > 1 EA current supply cable 20m (66ft) with CE-plug for operation by the external electrical supply > 1 set of nitrogen connections for world-wide application OPTIONS > Option - Spring-loaded chassis In case of long towing distances, the device must be prevented from damage by integrating spring-loaded axes into the chassis. > Option - Cover paint alternative to standard Paint is skydrol-resistant. Standard-cover paint: light grey (RAL 7035) / yellow orange (RAL 2000) ACCESSORIES (optionally available) > Drum pump - with the drum pump, the medium can easily be pumped off the canister or off a barrel into the Main-Reservoir. > PH-Meter - to determine the ph-value of the medium according to AMM > Sampling glass - measuring glass for sample taking of the medium during ph-value measurement. > Dust Cover- for protection from climatic influences and contamination during storage. Page 5 / 9

PH-meter (symbolic figure) drum pump (symbolic figure) sampling glass (symbolic figure) dust cover (symbolic figure) Page 6 / 9

Handpump-Topup,SCS >SCST1-TU< PURPOSE > The device is developed for the following purposes: - Top Up of Accumulator - Top Up and Drainage of Small ACU - Top Up and Drainage of SCS Chiller - Top Up and Drainage of VCRU GENERAL INFORMATION > Simple manual operation, filling procedure via integrated handpump > No electrical supply required > Tank with filling point, venting deaeration filter, drain plug and sight glass for fill level control > Pressure indication via pressure gauge on the operating plate, integrated hydraulic filter to clean the medium > Connection to the A/C or its components in combination with the adapter kits>scst1-ak350cu< and >SCST1-AK350GSP< ADDITIONAL INFORMATION > Laterally mounted retainers for the storage of the fill or drain hose > Removable collecting reservoir to catch used medium > Tow bar with grip and towing eye for manual manoeuvering or transporting the device with an appropriate towing vehicle > User friendly ergonomic setup of the device, simple, compact and robust setup, such as easy access for maintenance tasks Page 7 / 9

TECHNICAL DATA > Nitrogen supply (requirements): > Operating conditions: Pressure: min. 6bar (87psi) max. 200bar (2,900psi) Ambient temperature: -30 to +50 C (-22 to +122 F) > Main-Reservoir: Storage temperature: -30 to +60 C (32 to 140 F) Volume: Usable volume: 30l (7.9gal) 18l (4.8gal) Rel. air humidity: 5 to 90% (non-condensing) Propylen Glycol Water (according to AIRBUS specification) (not included in the scope of delivery) CONTROL UNIT > Colourless eloxated front panel > Imprinted hydraulic schematics > Resistant against mineral oils and other fuels > Clearly arranged operating elements (Symbolic figure) Page 8 / 9

Kit-Adapter GSP, SCS350 >SCSt1-AK350GSP< GENERAL INFORMATION > Developed for the connection of the GSE and the A/C > Appropriate for the following GSE: - >SCST1-TU< - >SCST1-FD< - >SCST1-FD-D< > For the following purposes: - Top Up of Accumulator - Filling of Whole System - Draining of Whole System Kit-Adapter CU, SCS350 >SCSt1-AK350CU< GENERAL INFORMATION > Developed for the connection of the GSE and the A/C > Appropriate for the following GSE: - >SCST1-TU< - >SCST1-FD< - >SCST1-FD-D< > For the following purposes: - Top Up and Drainage of Small ACU - Top Up and Drainage of SCS Chiller - Top Up and Drainage of VCRU Technical data are subject to change! Page 9 / 9