RECON ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL. Document revision: 1.2 Last revised: October 25, 2017

Similar documents
ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL

INSTALLATION MANUAL. Document revision: 1.3 Last revised: January 2, 2019

INSTALLATION MANUAL Document revision 2.0 Last revised: October 11, 2017

INSTALLATION MANUAL Document revision 2.1 Last revised: April 3, 2018

WIRELESS BLOCKAGE MONITOR INSTALLATION MANUAL

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

GPS Steering System Installation Manual

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS

GPS AutoSteer System Installation Manual

Operator s Manual. Wi-Fi Air Drill Rate and Blockage ECU. MNST08205 P a g e 1 Software Revision 2.3.0

Memphis Pro Built-In Model Number VGB0001S Appendixes and Model-Specific Information Contents

ASSEMBLY MANUAL. 45-Foot Air Double Disc Drill. Amity Technology, LLC th Avenue North Fargo, ND (701)

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

GPS AutoSteer System Installation Manual

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

Smart Wi-Fi Sprinkler Timer and Flow Meters

Installation Guide CLAAS Lexion Combines with 9 inch Elevators

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Installation Instructions for Lingenfelter GM 2500 Suburban & Yukon XL Auxiliary Fan System (with ECM controlled fan output)

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

AutoSteer Installation Guide

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

HP Modular Cooling System 200/100 Options Installation Guide

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Nissan GTR Alpha Fuel System

LoadMaxx. Installation Guide. For Air Ride Trailers. Air-Weigh Customer Support: PN R0

GPS AutoSteer System Installation Manual

6945 (12v) 6944 (24V) installation instructions

User Guide Electronic Logging Device

Part Number: TTU-BGB14-DRL TTU-BGP14-DRL

Torque Module Installation and User Guide for model 250i Motorcycle Dynamometers.

GPS AutoSteer System Installation Manual

RoadRelay 4. Installation Guide

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

GPS AutoSteer System Installation Manual

SCION im PREMIUM AUDIO Preparation

GPS AutoSteer System Installation Manual

08-18 STI Flex Fuel Bluetooth Mk2 Kit Install Instructions For Cobb Tuning Access Port

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

Assembly Instructions for A, A, A, & A

GPS AutoSteer System Installation Manual

INSTALLATION MANUAL. AutoSteer Install Kit: AutoTrac Ready Installation

MF 9690, 9790, Challenger 660, 670

REAR STEEL BUMPER INSTALLATION INSTRUCTIONS Runner

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

GM TRUCK BACKUP CAMERA INSTALLATION

GPS AutoSteer System Installation Manual

PFadvantage JD 3300/4400/6600/7700; 4420

Vehicle Security / Remote Start / Remote Access System Installation

Vehicle Security / Remote Start / Remote Access System Installation

SP PRO ABB Managed AC Coupling

Steer Ready Kit Installation Guide

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

TABLE OF CONTENTS YOUR MISTBOX S SERIAL NUMBER

AutoSteer Installation Guide

Installation. Manual. OnTrac2+ GPS Assisted Steering System PN: A

Wired Real Time GPS Installation Instructions

Desktop 5.5 Z Axis Retrofit

WiFi Tank Level Monitor Installation Instructions

Installation Manual, Usage Tips, & Warranty Information

Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

SCION tc 2014 FOG LIGHT KIT

* * APPLICABLE MODELS: 2016 > CX-3

Crestline Dampening System. Installation Instructions. A.B. Dick 350, 360, 375 Single & Dual Lever Machines. X /01 Rev-A

Signal Mirror Installation Instructions

Vehicle Security / Remote Start / Remote Access System Installation

INSTALLATION INSTRUCTIONS Part# , , ,

To get started with RLINK, install the RLINK Smart Device on your bike using this guide.

Items Supplied > Application(s) > Instruction Manual >

SCION tc PREMIUM AUDIO Preparation. Part Number: PT (Extension Module w/ AHA)

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

General Information. Assembly Instructions for A. Base Update 2005 Kit. Update Instructions Yield-Pro 1625 Planter

LoadMaxx. Installation Guide. For Trailers with Mechanical Suspensions. Air-Weigh Customer Support: PN R0

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

icon User s manual Table of Contents section 6 icon module installation and removal

* * APPLICABLE MODELS: 2014 > Mazda 3

App Manual Solution Features

Overhead Twin Line Irrigation Installation Guide COM 2 Copyright First Tunnels Ltd 2012.

Ford Mustang V6 OEM-Style Fog Light Kit Parts List: Quantity: Tool List:

Instructions for 2-row monitoring only

TOYOTA RAV FOG LIGHT KIT Preparation

* * APPLICABLE MODELS: 2014 > Mazda 6

SCION tc Navigation System Preparation. Part Number: PT

CorkSport ort Mazda 3 Adjustable Shifter Mazdaspeed 3, Mazda 3 6-speed and Mazda3 SkyActiv 6-speed

Seed Rate Charts for the YP1225 or YP1625 Planters

Installation Manual P / P / P A / P B / P C E N G I N E B R A K E S

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

LoadMaxx. Installation Guide. Volvo T-Ride and Freightliner Tuf-Trac Suspensions. Welded Steer and Drive Brackets

80703 & Backside License Plate Mount for Jeep JK Wrangler (80707) & 10+ (80703)

Splicing Procedures 1

* * APPLICABLE MODELS: 2017 > CX-5

SATURN SKY 2006 AND UP

EksoVest Operator Manual

Table Of Contents TABLE OF CONTENTS INTRODUCTION INSTALLATION OPERATING INSTRUCTIONS APPENDIX ABOUT THE JUICE... 3 SAFETY TERMS...3 INTRODUCTION...

Transcription:

RECON ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL Document revision: 1.2 Last revised: October 25, 2017

Recon Zone Blockage and Flow Monitor Installation Manual 2017 Intelligent Agricultural Solutions. All Rights Reserved. Recon Zone Blockage and Flow Monitor Installation Manual. All content within is copyrighted by Intelligent Agricultural Solutions, and may not be reprinted without permission. The content of this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Intelligent Agricultural Solutions. Intelligent Agricultural Solutions assumes no responsibility or liability for any errors or inaccuracies that may appear in the content contained in this guide. U.S. Patent #8,950,260B2, and foreign patents pending. Recon and Zone Blockage and Flow Monitor, Intelligent Agricultural Solutions, Intelligent Ag, Intelligent Ag Monitoring Solutions, IAS, and the IAS logo are trademarks or registered trademarks of Intelligent Agricultural Solutions. ipad is a registered trademark of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. All other trademarks are property of their respective owner. Intelligent Agricultural Solutions, 1810 NDSU Research Circle North, Fargo, ND 58102 USA. Visit us on the web at www.intelligentag.com Questions? E-mail us at info@intelligentag.com 600840-000042 Page 2 of 31

Table of Contents 1. Introduction... 6 1.1. About Recon Zone Blockage and Flow Monitor... 6 1.2. Additional required tools and equipment... 6 1.3. Installation Overview... 6 2. Install Recon Zone Blockage and Flow Monitor... 7 2.1. Install ECUs... 7 2.2. Install flow sensors... 8 2.3. Connect auditory hoses to ECUs...16 2.4. Install Gateway 300...17 2.5. Install Wi-Fi antenna...18 2.6. Install the work switch...20 3. Connect harnessing...23 3.1. Connect Tractor and Intermediary harnesses...23 3.2. Connect gateway harness...24 3.3. Connect ECU wiring harnesses...24 4. Install the ipad and Intelligent Ag Pro app...25 4.1. Install the ipad...25 4.2. Download the Intelligent Ag Pro app...25 4.3. Connect to the Gateway 300...25 List of Figures Figure 1: Parts needed to install ECUs... 7 Figure 2: Installing ECUs... 7 Figure 3: Sensor types... 8 Figure 4: Spacing flow sensors on a manifold... 9 Figure 5: Installing Streamline 1-inch and 1.25-inch flow sensors on a manifold... 9 Figure 6: Correctly placing the hose clamps...10 Figure 7: Installing 90 degree flow sensors on an air seeder...11 Figure 8: Installing 1.25-inch flow sensors on an air seeder...12 Figure 9: Preparing the adapters...12 Figure 10: Securing hose pieces into adapter...13 Figure 11: Spacing flow sensors on a box drill...14 Figure 12: Installing flow sensors on a box drill...15 Figure 13: Connecting auditory hoses to the ECU on a manifold...16 Figure 14: Connecting auditory hoses to the ECU on a box drill...16 Figure 15: Installing the Gateway 300...17 Figure 16: Mounting the antenna...18 Figure 17: Work switch assemblies...20 Figure 18: Mounting location for work switch (900000-000001)...21 Figure 19: Installing a magnetic work switch on an implement with no existing work switch...22 Figure 20: Assembling the magnetic work switch assembly...22 Figure 21: Installing a drip loop...23 Figure 22: 6 manifold wiring diagram...26 Figure 23: 12 manifold wiring diagram...27 Figure 24: Tow-between air cart wiring diagram...28 Figure 25: 2 box drill wiring diagram...29 Figure 26: 3 box drill wiring diagram...30 600840-000042 Page 3 of 31

List of Tables Table 1: Parts needed to install Streamline 1-inch and 1.25-inch flow sensors... 9 Table 2: Parts needed to install 90 degree flow sensors...11 Table 3: Parts needed to install 1.25-inch flow sensors...12 Table 4: Parts needed to install flow sensors on a box drill...14 Table 5: Parts needed to install Gateway 300...17 Table 6: Parts needed to install Wi-Fi antenna...18 Table 7: Gateway connectors...19 Table 8: Parts needed to install the work switch (whisker switch)...20 Table 9: Parts needed to install the work switch (magnetic work switch)...21 Table 10: Parts needed to connect harnessing...23 Table 11: System Configuration Table...31 600840-000042 Page 4 of 31

Revision Number Record of Revision Change Description Revision Date Inserted By 1.0 Initial release 1/23/17 AAL 1.1 Added Gateway connectivity info 2/24/17 AAL 1.2 Added new Streamline 1.25 sensor and whisker switch 10/25/17 AAL 600840-000042 Page 5 of 31

1. Introduction 1.1. About Recon Zone Blockage and Flow Monitor The Recon Zone Blockage and Flow Monitor enables you to monitor for major blockages on your air seeder or box drill without monitoring every run. 1.2. Additional required tools and equipment You will need the following tools and equipment to install the Recon Zone Blockage and Flow Monitor: Standard wrench and socket sets Measuring tape Cutting tool, such as a box cutter or shears Cordless drill with 5/16 driver and/or flathead screwdriver (optional) Paint pen or other permanent marking tool (optional) Dielectric grease (optional) 1.3. Installation Overview The Recon Zone Blockage and Flow Monitor is installed through the following steps: Install ECUs Install flow sensors Connect auditory hoses to ECUs Install Gateway 300 Install antennas Install work switch Connect harnessing Install ipad and Intelligent Ag Pro app NOTE: Detailed wiring diagrams are found in Appendix A. For videos, current documentation, and other resources, visit www.intelligentag.com/support. 600840-000042 Page 6 of 31

2. Install Recon Zone Blockage and Flow Monitor 2.1. Install ECUs The Electronic Control Units (ECUs) communicate the flow measurement data recorded by the flow sensors to the Gateway 300. For each manifold or product holding tank that will be monitored, complete the steps below. Part name Part number Quantity needed ECU 153510-000045 varies U-bolt 352013-000007 or 352013-000008 or 352013-000009 varies Figure 1: Parts needed to install ECUs Installation location: Manifold towers or box drill toolbar Figure 2: Installing ECUs 1. Position two U-bolts (352013-000007, 352013-000008, or 352013-000009) on the mounting location as shown in Figure 2 and place the saddle clamp overtop of the U- bolt. 2. Secure the unused end of the U-bolts with nuts. 3. Place the ECU (153510-000045) on the other end of the U-bolts so that the LED is facing the cab. If this orientation is not possible, position the ECU so that the LED does not face the ground. Secure with nuts. NOTE: ECUs can be mounted in any order; however, installing the ECUs in numeric order based on the ECU s serial number (located on the front of the ECU) is an easy way to remember which ECU is on each tower. Use the table in Appendix B to record your system setup. 600840-000042 Page 7 of 31

2.2. Install flow sensors Flow sensors detect when seed or fertilizer is flowing through the run. The installation of flow sensors will vary depending on your system setup. Refer to Section 2.2.1 for installing on a system with manifolds. Refer to section 2.2.2 for a box drill. 2.2.1. Installing flow sensors on a manifold The system uses either 1-inch, 90 degree, or 1.25-inch flow sensors (and adapters, if needed) based on your implement and blockage and flow monitoring preferences. Identify your sensor type and part number by looking at your pack slip or the images below. Refer to the correct installation instructions in this section based on your flow sensor size. Streamline 1 sensor (153510-000022) Streamline 1.25 sensor (153510-000066) 90 degree sensor (153570-000015) 1.25 inline sensor (153570-000016) Figure 3: Sensor types 600840-000042 Page 8 of 31

Installation location: On each manifold being monitored. Distribute flow sensors evenly around the manifold. EXAMPLE: Spacing 2 sensors (left) and 4 sensors (right) on a 16-opener manifold Figure 4: Spacing flow sensors on a manifold Installing Streamline 1-inch and 1.25-inch flow sensors (153510-000022 and 153510-000066) Part name Part number Quantity needed Streamline 1-inch flow sensor or 153510-000022 or Streamline 1.25-inch flow sensor 153510-000066 1/run Adapter (optional) 353070-000038 or 353070-000112 or 2/run 353070-000113 Hose clamp 356060-000025 2/run Table 1: Parts needed to install Streamline 1-inch and 1.25-inch flow sensors Figure 5: Installing Streamline 1-inch and 1.25-inch flow sensors on a manifold 600840-000042 Page 9 of 31

For each run that will be monitored: 1. If you are using adapters, snap adapters into the sensor as shown in Figure 5. 2. Cut the original run hose to about 8 inches (20.32 cm), or other length that allows a downward flow and appropriate fit once the sensor and adapters (if applicable) are installed. 3. Orient the sensor so that the flow arrows point away from the manifold. Slide the sensor assembly on the final run hose piece attached to the manifold until the hose piece hits the backstop inside the adapter or sensor. Try to keep the sensor mounted vertically. 4. Secure using a hose clamp between the two ridges on the end of the sensor assembly, ensuring that the hose clamp lays flat and the head (worm drive) does not hit the sensor ridge, as shown in Figure 6. Figure 6: Correctly placing the hose clamps 5. Slide the remaining final hose piece into the lower end of the sensor assembly until the hose piece hits the backstop inside the adapter or sensor. Secure using a hose clamp between the two ridges on the end of the sensor assembly, ensuring that the hose clamp lays flat and the head (worm drive) does not hit the sensor ridge. 600840-000042 Page 10 of 31

Installing 90 degree flow sensors (153570-000015) Part name Part number Quantity needed 90 degree flow sensor 153570-000015 1/run Adapter (optional) 351060-000008 1/run Hose clamp 352013-000010 2-4/run Table 2: Parts needed to install 90 degree flow sensors For each run that will be monitored: Figure 7: Installing 90 degree flow sensors on an air seeder 1. Detach the existing hose from the manifold. 2. Place a sensor (153570-000015) on the manifold, orienting the sensor so that auditory hose routes down. If the sensor does not fit directly on the manifold, attach an adapter (351060-000008) to the sensor. Secure with a hose clamp (352013-000010). 3. Slide the remaining final hose piece into the other end of the sensor. If the hose doesn t fit on the sensor, attach an adapter to the sensor. Secure with a hose clamp. 600840-000042 Page 11 of 31

Installing 1.25-inch flow sensors (153570-000016) Part name Part number Quantity needed 1.25-inch flow sensor 153570-000016 1/run Adapter (optional) 353070-000029 or 353070-000031 or 353070-000022 or 2/run 353070-000030 or 353070-000032 Hose clamp 352013-000010 or 356060-000025 2-4/run Table 3: Parts needed to install 1.25-inch flow sensors For each run that will be monitored: Figure 8: Installing 1.25-inch flow sensors on an air seeder 1. Bend each adapter in half until the center seam holding the two halves together snaps. Align the two halves to make a cylinder. Figure 9: Preparing the adapters 600840-000042 Page 12 of 31

2. Attach an adapter to each end of the sensor (153570-000016) and secure with a hose clamp (352013-000010 or 356060-000025). 3. Cut the original run hose about 8 inches (20.32 cm), or other length to ensure a downward flow and appropriate fit once the sensor and adapters (if applicable) are installed. 4. Orient the sensor so that the flow arrows point away from the manifold. Place the upper adapter on the final run hose piece, making sure that the hose is pushed into the adapter past the retaining ring and locking tabs until it hits the backstop (about 2 inches). Try to keep the sensor mounted as vertically as possible. Secure using a hose clamp. Figure 10: Securing hose pieces into adapter 5. Slide the remaining final hose piece into the lower adapter until it hits the backstop. Secure using a hose clamp between the two ridges on the end of the sensor assembly. 600840-000042 Page 13 of 31

2.2.2. Installing flow sensors on a box drill Part name Part number Quantity needed Adapter (optional) Sensor Hose clamp 353070-000029 or 353070-000031 or 353070-000022 or 353070-000030 or 353070-000032 or 353070-000038 153510-000022 or 153570-000016 352013-000010 or 356060-000025 Table 4: Parts needed to install flow sensors on a box drill 2/run 1/run 2-4/run Installation location: On the hose that is second from the end of each side of each product holding tank. Distribute any remaining sensors evenly across the product holding tank. EXAMPLE: Location for 2 sensors on a 12-opener product holding tank For each run that will be monitored: Figure 11: Spacing flow sensors on a box drill 1. Disconnect the existing hose from the drill. Cut off a length of hose about equal to the length of the sensor and adapters (if applicable) so that the hose isn t too long when the sensor assembly is installed. 2. Orient the sensor (153510-000022 or 153570-000016) so that the flow arrows point down. 3. OPTIONAL: Place an adapter onto the top end of the sensor and secure with a hose clamp (352013-000010 or 356060-000025). 4. Place the sensor assembly on the drop tube and secure with a hose clamp. 5. Place the final run hose onto the bottom end of the sensor and secure with a hose clamp. 600840-000042 Page 14 of 31

NOTE: Cutting a small slit in the end of the hose may help the hose to expand and go onto the sensor more easily. Figure 12: Installing flow sensors on a box drill 600840-000042 Page 15 of 31

2.3. Connect auditory hoses to ECUs The sensor s auditory hoses allow the sound to be transmitted from the sensor to the ECU. For each sensor, complete the steps below. 1. Remove the caps from the ECU ports that you will be using, beginning with ECU port 1. The number of ECU ports that you will use is equal to the number of sensors installed on the manifold or box drill. 2. Remove and discard the cap at the end of each auditory hose (if it has a cap). Push each sensor s auditory hose on top of its corresponding ECU port. ECU ports should be connected in a clockwise order on a manifold, and left-to-right order on a box drill. EXAMPLE: 2 sensors (left) and 4 sensors (right) on a 16-opener manifold Figure 13: Connecting auditory hoses to the ECU on a manifold EXAMPLE: 2 sensors on a 12-opener product holding tank Figure 14: Connecting auditory hoses to the ECU on a box drill NOTE: If all auditory hoses are too short, pull the existing auditory hoses off of the sensors and replace them with the 10 hoses included with the kit. All auditory hoses on the entire system must be the same length. 3. OPTIONAL: Mark the associated ECU port number on each flow sensor hose using a paint pen or other marking tool. 600840-000042 Page 16 of 31

2.4. Install Gateway 300 The Gateway 300 is a computing platform that allows for the communication from the ECUs to the ipad. To install the gateway, complete the steps below. Part name Part number Quantity needed Gateway 300 153010-000042 1 ¼ flat washer 352012-000002 8 352013-000007 or U-bolt and mounting 352013-000008 or hardware 352013-000009 2 Gateway mounting bracket 353070-000079 1 ¼-20 x 1 1/2 screw 356060-000033 4 ¼"-20 nut 356060-000075 4 Table 5: Parts needed to install Gateway 300 Installation location: The toolbar or on the air cart (if using a tow between air cart) Figure 15: Installing the Gateway 300 1. Position the Gateway 300 (153010-000042) on the mounting bracket (353070-000079). The gateway can be mounted on the bracket in any direction, but the connectors should not face up when the bracket is mounted on the implement or air cart. 2. Secure the gateway to the mounting bracket using the provided screws (356060-000033), washers (352012-000002), and nuts (356060-000075). 3. Mount the gateway to the toolbar or on the air cart (if using a tow between air cart) using the provided u-bolts and mounting hardware (352013-000007, 352013-000008, or 352013-000009). The mounting location must provide the gateway with a clear view of the sky. 600840-000042 Page 17 of 31

2.5. Install Wi-Fi antenna The Wi-Fi antenna sends information to the Gateway 300. Part name Part number Quantity needed SMA cap 251015-000139 3 Wi-Fi antenna 252005-000010 1 U-bolts and mounting hardware 352013-000007 2 Antenna bracket 353070-000083 1 Table 6: Parts needed to install Wi-Fi antenna Installation location: Mounted on the air cart frame or railing. Figure 16: Mounting the antenna 1. Thread the antenna (252005-000010) cables through the hole on the antenna bracket (353070-000083) and the nut. Attach the antenna to the antenna bracket by tightening the nut. 2. Mount the bracket to the implement using the u-bolts and mounting hardware (352013-000007). 3. Connect the antenna cables to the gateway. Refer to the table below for the associated gateway connectors. 600840-000042 Page 18 of 31

Gateway Function Connector 1 Wi-Fi 2 Iridium 3 433-MHz 4 Cellular Main 5 GPS 6 Cellular Diversity Table 7: Gateway connectors 4. Cap any unused gateway connectors using caps (251015-000139). 600840-000042 Page 19 of 31

2.6. Install the work switch The work switch signals to the Intelligent Ag Pro app when the implement is in or out of the ground. Types of work switches Intelligent Ag sells two different types of work switches: a whisker switch and the magnetic work switch. Identify your work switch type and part number by looking at your pack slip or the images below. Work switch assembly (whisker switch) Work switch assembly (magnetic) 900000-000001 153560-000014 Figure 17: Work switch assemblies Installation location Next to the implement s existing work switch, if one exists. The existing work switch is typically found towards the center of the implement s frame on a hydraulic cylinder. If the implement does not have an existing work switch, find a location on the hydraulic cylinders that are used to lift the implement in and out of the ground at the end of rows. 2.6.1. Installing the work switch (900000-000001) NOTE: Skip this step and follow the instructions in Section 2.6.2 if you are using the magnetic work switch with part number 153560-000014. Refer to Figure 17 to identify your work switch. Part name Part number Quantity needed Work switch ECU harness 355020-000018 1 Work switch assembly 900000-000001 1 Table 8: Parts needed to install the work switch (whisker switch) Mount the work switch in a location where the work switch is triggered when the toolbar is in the lowered position. TIP: You can mount the work switch (900000-000001) onto an existing work switch bracket, if one exists. NOTE: You can unscrew the work switch magnet from the bracket and re-attach it to the other end of the bracket to allow for other mounting orientations. 600840-000042 Page 20 of 31

Figure 18: Mounting location for work switch (900000-000001) About work switch methods The work switch uses one of two methods to determine when the implement is in the ground: Default method: the work switch is engaged (the work switch is triggered by the height sensor) when the implement is in the ground. Likewise, the work switch is disengaged (the work switch is not triggered) when the implement is out of the ground. Inverted method: the work switch is disengaged (the work switch is not triggered) when the implement is in the ground. Likewise, the work switch is engaged (the work switch is triggered by the height sensor) when the implement is out of the ground. Your work switch method will be configured during configuration in the Intelligent Ag Pro app. 2.6.2. Installing the work switch (153560-000014) Part name Part number Quantity needed Work switch assembly 153560-000014 1 Work switch bracket 351050-000016 1 Work switch magnet 359035-000001 1 Table 9: Parts needed to install the work switch (magnetic work switch) Installation location: Near the implement s existing work switch, if there is one. Otherwise, in a location on the hydraulic cylinder where you can mount the work switch and magnet so that they will be moved apart when the implement is out of the ground. 600840-000042 Page 21 of 31

Figure 19: Installing a magnetic work switch on an implement with no existing work switch 1. Place the work switch magnet (359035-000001) on the hydraulic cylinder or frame. 2. Remove the front locknut from the work switch assembly (153560-000014) and insert it into the work switch bracket (351050-000016). Replace the locknut. Figure 20: Assembling the magnetic work switch assembly 3. Attach the work switch bracket to the cylinder using bolts (352010-000084), washers (352012-000024) and locknuts (352011-000040), or using zip ties. The mounting location should allow at least 4 inches of movement when you re lifting or lowering the tool. To adjust the length of the work switch, adjust the locknuts on the work switch assembly. 600840-000042 Page 22 of 31

3. Connect harnessing Refer to Appendix A for wiring diagrams. TIP: Leave a drip loop for harnessing parallel to the ground. Figure 21: Installing a drip loop TIP: Apply dielectric grease to connectors to provide a better seal. Part name Part number Quantity needed Sealing plug 153510-000019 2 CAN termination plug 153510-000051 2 Tractor harness 353050-000010 1 Work Switch Extension 353050-000011 varies harness (optional) Gateway harness 353050-000024 1 10 ECU harness 353050-000025 1 20 ECU harness (optional) 353050-000027 varies Power/CAN Split harness 353050-000028 1 Intermediary harness (optional) 353050-000030 varies Table 10: Parts needed to connect harnessing 3.1. Connect Tractor and Intermediary harnesses 1. Connect S2 of the Tractor harness (353050-000010) into the convenience outlet of the tractor. 2. Insert a sealing plug (153510-000019) into S1 of the Tractor harness. 3. Connect S3 of the Tractor harness to S1 of the Gateway harness (353050-000024). If you need more harnessing to reach the Gateway harness, connect S3 of the tractor harness to S1 of the Intermediary harness (353050-000030). Then, connect S2 of the Intermediary harness to S1 of the Gateway harness. 600840-000042 Page 23 of 31

3.2. Connect gateway harness 1. Connect S3 of the Gateway harness into Port A of the Gateway 300. 2. Connect S4 of the Gateway harness into Port B of the Gateway 300. 3. Connect S2 of the Gateway harness into S1 of the Power/CAN Split harness (353050-000028). 4. Connect S5 of the Gateway harness into the work switch. If you need more harnessing to reach the work switch, connect S5 of the Gateway harness into S1 of the Work Switch Extension harness (353050-000011). Then, connect S2 of the Work Switch Extension harness to the work switch. 3.3. Connect ECU wiring harnesses 3.3.1. Connecting ECU wiring harnesses on a manifold 1. Connect S3 of a 10 ECU harness (353050-000025) to each ECU. 2. Connect S1 of each ECU harness to S2 of the nearest ECU harness to form a daisy chain on each half of the toolbar. Leave S1 of the centermost ECU harnesses open. There will be one unused S2 connector on each half. NOTE: If there are areas where you need a longer ECU harness, use a 20 ECU harness (353050-000027) instead of a 10 harness. 3. Insert a CAN termination plug (153510-000051) into the two unused S2 ends of the ECU harness. 4. Connect S2 and S3 of the Power/CAN Split harness (353050-000028) to S1 of each of the two centermost ECU harnesses. 5. Route loose harnessing toward the tractor and secure using zip ties. 3.3.2. Connecting ECU wiring harnesses on a box drill 1. Connect S3 of a 10 ECU harness (353050-000025) to each ECU. If installing on a 3 box system, use a 20 ECU harness (353050-000027) instead of a 10 harness on one of the outermost boxes. 2. If installing on a 3 box drill, connect S1 of an ECU harness to S2 of the nearest ECU harness. Leave S1 of the third ECU harnesses open. If installing on a 2 box drill, skip this step. 3. Insert a CAN termination plug (153510-000051) into the two unused S2 ends of the ECU harnesses. 4. Connect S2 and S3 of the Power/CAN Split harness (353050-000028) to S1 of the open ECU harnesses. 5. Route loose harnessing toward the tractor and secure using zip ties. 600840-000042 Page 24 of 31

4. Install the ipad and Intelligent Ag Pro app 4.1. Install the ipad Part name Part number Quantity needed Tablet mount arm 352004-000003 1 Rail attachment 352004-000004 1 ipad mount 356070-000004 1 1. Insert the ball of the tablet mount arm (352004-000003) into the back of the ipad mount (356070-000004). 2. Connect the rail attachment (352004-000004) to the bottom of the mount arm. 3. Connect the rail attachment to the tractor cab s mounting bar, or other desired installation location. 4. Place the ipad in the mount. 4.2. Download the Intelligent Ag Pro app To interface with the system, you need to download the Intelligent Ag Pro app from the Apple App Store and install it onto your ipad. To install the app: 1. Connect the ipad to the internet. 2. Tap the App Store icon on the ipad s home screen. 3. Tap the Search field in the top right corner of the App Store screen. 4. Type Intelligent Ag Pro in the search field and tap the Search button. 5. Tap the Intelligent Ag Pro app when it appears in your search results. 6. Tap the Get button and tap Install. Enter your Apple ID and password, if prompted. A progress bar will appear over the app s icon while it is downloading. 4.3. Connect to the Gateway 300 1. Ensure that you have power to the ECUs and gateway. 2. Tap the Settings icon on your ipad s home screen. 3. Tap Wi-Fi. 4. Connect to the IASBlockage network. 5. Press the ipad s Home button and open the Intelligent Ag Pro app. Follow the on-screen prompts to begin configuring your system. 600840-000042 Page 25 of 31

Appendix A: Wiring Diagrams Figure 22: 6 manifold wiring diagram Four ECU harness 10, two ECU harness 20, one each all other harnesses 600840-000042 Page 26 of 31

Figure 23: 12 manifold wiring diagram Ten ECU harness 10, two ECU harness 20, one each all other harnesses 600840-000042 Page 27 of 31

Figure 24: Tow-between air cart wiring diagram 600840-000042 Page 28 of 31

Figure 25: 2 box drill wiring diagram Two ECU harness 10, one each all other harnesses 600840-000042 Page 29 of 31

Figure 26: 3 box drill wiring diagram Two ECU harness 10, one ECU harness 20, one each all other harnesses 600840-000042 Page 30 of 31

Appendix B: System Configuration Table Use the following table to record notes about your system configuration. Primary or Section # ECU Serial # # of Runs Product Notes on Ports Out of Sequence (i.e. Run 5 on Port 12 ) Table 11: System Configuration Table 600840-000042 Page 31 of 31