ULTRAFLOW type 65-S/65-R

Similar documents
Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

MULTICAL 602 & ULTRAFLOW

Heat meter (E1) θ: 2 C C. DK-0200-MI qp, p/l: See display. S/N: /K8/17 Type: 603C219. Pt500-EN Battery, 1 x D-cell

Installation & User Guide. Multical 801. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Installation and User Guide MULTICAL 801. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

MULTICAL 62 DATA SHEET. Application

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

MULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

MULTICAL 6M2. Data sheet

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

SonoSensor 30 Ultrasonic flow sensor

WATERFLUX 3070 Quick Start

ULTRASONIC FLOW SENSOR IFX-M4-01

Kamstrup Valve. Data sheet

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Level Sensor with G1/2" Thread Hygienic

Level Sensor with M12 Thread Hygienic

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Pressure Transmitters

Differential Pressure Sensors

SIGNET 7002 Vortex Flow Sensor ENGLISH

Octave Water Meter Installation Manual

SonoMeter 30 Energy Meters

PSS 5000 Standard & Compact (For systems with CPB50x)

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

OPERATING INSTRUCTIONS Flow sensors with connecting flanges DN CE

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

SonoMeter 30 Energy Meters

Type 2REX-A. Oil & Gas / Heavy Industry

A Member of the. Integrated Metering Technologies

Inductive Proximity Sensor

TC2-ES MANUAL Page 1 OPERATING INSTRUCTIONS USER INFORMATION TC2-ES POWER SUPPLY

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Liquid Turbine Flow Meter OwnerÊs Manual

Differential Pressure Sensors

Compact Pressure Transmitter DAN-HH

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER

Level Measurement based on Archimedes Principle. Device Description

Compact System NRGS 11-2 NRGS Original Installation Instructions English

INSTRUCTIONS. SILEX demineralizers. Type 1 B and 2 B. Our World is Water. D1A-30Bver4. Instructions. SILHORKO-EUROWATER A/S Phone

Indoor Linear 50W Driver SI-CU WW

Switching DC Power Supply

QSI (Q-Star) Electronics Owner s Manual

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Specification of Soneil Battery Charger

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

HYDROMETER. Operating Instructions Edition 03/ Revision 05. Ultrasonic flowmeter type SHARKY 475 [ ] A5E HYDRO.PS.022.Q5.

Pressure Reducing Valve Type 2114/2415

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Continuous level sensor NSK

HYDRUS ULTRASONIC METER

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

APP pump instruction APP and APP 16-22

Inductive Proximity Sensor

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Owner s Manual. DC-DC Step Down Converter

product specification

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Pressure Transmitters for Sanitary Applications Model SA-11

Specification of Soneil Battery Charger

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Harness the Power of the Sun

zelsius Installation and operating manual All that counts. EnergyMetering

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

A Member of the. Integrated Metering Technologies

Product Data Sheet 3214 JH3-195

Product Data Sheet 624 NR. The engineer's choice

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

Model TUR-200D Turbine Flowmeter

Air Handling Units. Geniox. Accessories

Pressure Sensors. for liquid and gaseous media

Pressure transmitter for industrial applications Type MBS 4510

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Electromotoric Actuators

JUMO MIDAS S05 Pressure transmitter Type

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Ultrasonic heat meter

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

CORONA E ELECTRONIC METER MULTI-JET

Product Data Sheet 4118 N/ The engineer's choice

1100 Series Piston Type Differential Pressure Gauges

D/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

INSERTION flow sensor for continuous flow measurement

WATERFLUX 3070 Technical Datasheet

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Differential pressure sensor

CT325 TEMPERATURE CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

Pressure transmitters for industrial applications Type MBS 4510

PSU EN54-4 Power Supplies

Differential Pressure Sensors

Product Data Sheet 4184 N/17X. The engineer's choice

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

Transcription:

Installation ULTRAFLOW type 65-S/65-R Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg TEL.: +45 89 93 10 00 FAX: +45 89 93 10 01 info@kamstrup.com www.kamstrup.com

1. Installation Prior to installation of the flow sensor, the system should be flushed, and protection plugs/plastic diaphragms on the flow sensor should be removed. Correct placing of the flow sensor (flow and return) will appear from the front label of MULTICAL. The flow direction is indicated by an arrow on the side of the flow sensor. Glands and gaskets are mounted as shown in the drawings overleaf. Pressure stage of ULTRAFLOW type 65-S/R: PN16/PN25/PN40, see marking. Flow sensor marking does not cover included accessories. Temp. of medium, ULTRAFLOW type 65-S/R: 15 130 C Mechanical environment: M1 (fixed installation with minimum vibration). Electromagnetic environment: E1 (housing/light industry). The meter s control cables must be drawn at min. 25 cm distance from other installations. Climatic environment: Installation must take place in environments with non-condensing humidity as well as in a closed locations (indoors). The ambient temperature must be within 5 55 C. Maintenance and repair: The flow sensor is verified separately and can, therefore, be separated from the calculator. Battery for replacement: Kamstrup type 66-00-200-100. Other repairs require subsequent reverification in an accredited laboratory. ULTRAFLOW can only be connected direct to Kamstrup s calculators on terminals 11-9-10, as shown in section 5.3. Connection to other types of calculators require the use of a pulse transmitter. Note: Please make sure that pulse/litres is identical on flow meter and calculator. If the temperature of the medium exceeds 90 C, we recommend the use of flange meters as well as wall mounting of MULTICAL. In order to prevent cavitation the working pressure at ULTRAFLOW must be min. 1.5 bar at qp and min. 2.5 bar at qs (4.5 bar for DN80).This applies to temperatures up to approx. 80 C. ULTRAFLOW must not be exposed to lower pressure than the ambient pressure (vacuum). When the installation is complete, the water flow can be turned on. The valve on the inlet side must be opened first.

1.1 Installation angle for ULTRAFLOW ULTRAFLOW DN100 ULTRAFLOW can be mounted horizontally, vertically or at an angle. Important! In connection with ULTRAFLOW DN100, the plastic box containing the electronics must be placed on the side (when installed horizontally). ULTRAFLOW can be turned up to ±45 (in relation to the pipe axis).

1.2 Straight inlet Straight inlet: ULTRAFLOW requires neither straight inlet nor outlet to meet the Measuring Instruments Directive (MID) 2004/22/EC, OIML R75:2002 and EN 1434:2007. Only in case of heavy flow disturbances before the meter will a straight inlet section be necessary. We recommend to follow the guidelines in CEN CR 13582. 2. Examples of installation Threaded meter with MULTICAL /PULSE TRANSMITTER mounted on ULTRAFLOW. Flow from left Flow from right Short direct sensor mounted in ULTRAFLOW (only G¾ (R½) and G1 (R¾)) and glands fitted on the meter. Gasket Gasket Tightening approx. 4 Nm

Flange meter with MULTICAL /PULSE TRANSMITTER mounted on ULTRAFLOW Flow from left Flow from right Please note: For meters DN100, MULTICAL or PULSE TRANSMITTER cannot be mounted on the flow part. 3. Electric connection ULTRAFLOW MULTICAL Blue (GND)/11A 11 Red (supply) 9A 9 Yellow (signal)/10a 10 Connection: MULTICAL and ULTRAFLOW (ULTRAFLOW is supplied from MULTICAL )

4. Voltage supply of PULSE TRANSMITTER The PULSE TRANSMITTER can be supplied through a built-in lithium battery, a 24 VAC internal mains module or an internal 230 VAC mains module. The two wires on the battery or the mains module are mounted in terminal strips nos. 60 and 61. The polarity must be correct; red wire to terminal no. 60 (+) and black wire to terminal no. 61 (-). 4.1 Battery supply The PULSE TRANSMITTER is connected to a lithium battery, D-cell. The battery is marked with installation year, e.g. 2007, and manufacturing date. Optimal battery lifetime is obtained by keeping the battery temperature below 30 C, e.g. in connection with wall-mounting. The voltage of a lithium battery is almost constant throughout the entire battery lifetime (approx. 3.65 V). Thus, it is not possible to measure the remaining capacity of the battery. The battery must neither be charged nor short-circuited. Used batteries must be disposed of with consideration to the environment. 4.2 Mains modules The modules are under protection class II and are connected through a two-wire cable (without ground) through the cable nipple of the calculator, which is placed at the bottom on the right-hand side of the base unit. Use a feeder cable with an outer diameter of 5 10 mm and ensure correct dismantling and mounting of cable relief. Max. permitted fuse: 6 A Note! National regulations covering installations must be obeyed.

Black Red 24 VAC A transformer, e.g. type 66-99-403 for 24 VAC supply module must be used. Black Red 230 VAC In connection with direct mains connection this module must be used. NB: External supply must only be connected to the supply module. 5. Electric connection through PULSE TRANSMITTER ULTRAFLOW PULSE TRANSMITTER When long MULTICAL control cables In Out are used, please Blue (GND)/11A 11 11A 11 act with care when Red (supply) 9A 9 9A 9 installing. Control Yellow (signal)/10a cables must be 10 10A 10 installed with not ULTRAFLOW PULSE TRANSMITTER MAXICAL III less than a 25 cm In Out distance to other Blue (GND)/11A 11 11A 11 cables due to EMC. Red (supply) 9A 9 Yellow (signal)/10a 10 10A 10

5.1 Electric connection Connection to the PULSE TRANSMITTER 5.2 Block diagram The PULSE TRANSMITTER outlet 11A 9A 10A I max GND Supply (3 10 VDC) Signal 0.2 ma 5.3 Connection example Example of connection between ULTRAFLOW and MULTICAL (battery supply). 6. Functional control A functional control must be made, when installation of the entire energy meter is completed. Open thermostats and drain cocks to make the water flow in the heating system. Check that display values for temperature and water flow are reliable. 5511-704 GB/09.07/Rev. D1