PATTERSON PUMP COMPANY

Similar documents
Installation and Operation Instructions

JOCKEY PUMP CONTROLLERS

Instruction Bulletin. Jockey Pump Controller

XT SERIES Jockey Pump Controllers Features

IM K IM K. Instructions for Cutler-Hammer Jockey Pump Controllers

Pressure Makeup Jockey Pump Controller

SECTION MOTOR CONTROL

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

SECTION MOTOR CONTROLLERS

February, O & M Manual for EATON FDJ Series Jockey Pump Controllers. Instruction Booklet. For more information visit:

Mizer Single Pump and Starter Box

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION ENCLOSED CONTROLLERS

Duplex Commercial Pressurizer -DCP

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Horizontal Circuit Switchers

Horizontal Circuit Switchers

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Hydropak Booster Systems. Series motralec

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Electropneumatic Timing Relays Series 7000 Industrial

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

SECTION MOTOR CONTROLLERS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Programmable Logic Controller. Mat Nor Mohamad

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION PANELBOARDS

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

University of Houston Master Construction Specifications Insert Project Name

MODEL 10LH SPECIFICATION

TECHNICAL DATA. Trimpac 249a. September 16, 2013

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

DIESEL Engine Fire Pump Controllers Features

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

Quick Start Guide TS 910 & TS 920

Typical Specification

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

A25 Series Warm Air Control with Manual Reset

IN2 Enclosed Switches and Circuit Breakers

EPS-ECONOMY PUMP STARTER

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

SD Series Non-Fused Load Switches

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Contactors & Starters (Freedom)

Publication No.: PSG

W4100, W4200 & W4300 Electric Pump

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Series CC Condensate Units

P445 Series Electronic Lube Oil Control

P70, P72 and P170 Series Controls for High Pressure Applications

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

EXTREME R MOTOR OWNER'S MANUAL

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Design Standard. Purpose: Design Standard:

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Transfer switch OTEC and OTECSE open transition

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

Quick Start Guide TS 910

Submittal Data Information

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SECTION AIR TERMINAL UNITS

WARREN COUNTY, N.Y. M/E REFERENCE

Submersible Vacuum Fault Interrupters

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

SECTION MOTORS & MOTOR CONTROLLERS

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

TDX - Taco Duplex Starter with

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

P70, P72, and P170 Series Controls for High Pressure Applications

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

MOTOR TERMINAL CONNECTIONS

Direct Gas-Fired Heating

Electrical Control System Components Basics of Magnetic Control :

TotalPac 3 Firecyle III Wet pipe Remote controlled system

Multi-Pak Group Control

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Three-Phase Pole Mounted Recloser

TECHNICAL DATA 1-1/2 (dn40)

Transcription:

PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013

Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL Certified. These controllers are intended for use with fire pump systems. Jockey pumps are small, motor driven pumps used in conjunction with main fire pumps to compensate for minor leaks in the fire protection system and automatically maintain stand-by pressure. This reduces wear on the main pump and controller caused by unnecessary, frequent operation. Jockey Pump Controllers are available for across-the-line starting of the Jockey pump. Manual operation (Hand), by a Hand-Off-Auto selector switch, is independent of the pressure switch system. In Automatic operation (Auto), the Jockey Pump starts based on pressure. The pressure switch cut-in point is usually set approximately 10psi higher than that of the main controller to cause the Jockey Pump to operate first. In the event of a fire, the system pressure will drop further to start the main pump. Our standard Jockey Pump Controller includes: a Motor Starter Protector (MSP) with adjustable overload relays and external reset, a Hand-Off-Auto switch, and a diaphragm type pressure switch. The standard pressure switch has a range of 30-300psi, a maximum working range of 350psi, a proof pressure of 600psi, and is suitable for fresh water. This pressure switch is mounted inside the enclosure. The standard enclosure for our Jockey Pump Controller is a NEMA 3R enclosure painted with a red baked enamel finish. Standard Features: Built to NEMA standards Protected by Motor Starter Protector with adjustable Overload Dual Set Point Pressure Switch rated 30-300psi NEMA 3R Enclosure, complete with safety door interlock Hand-Off-Auto Selector Switch One N.O. Auxilliary Contact Baked Enamel Finish Patterson Pump Jockey Pump Controllers are assembled, wired and tested at the factory, and ready for immediate installation.

Instructions Jockey Pump Controllers WARNING! DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED! DEATH, PERSONAL INJURY, OR SUBSTANTIAL PROPERTY DAMAGE MAY RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING, AND ALWAYS FOLLOW GENERALLY ACCEPTED SAFETY PROCEDURES. JOCKEY PUMP CONTROLLER ON-OFF HANDLES MUST BE IN THE EXTREME OFF POSITION TO OPEN THE ENCLOSURE DOOR. PATTERSON CANNOT BE LIABLE FOR ANY MISAPPLICATION OR INCORRECT INSTALLION OF ITS PRODUCTS. MOUNTING CONTROLLER NOTE: Consult the appropriate job plans to determine the controller mounting location. Tools and materials (wall mounting) required: 1. Assortment of common hand tools of the type used to service electromechanical equipment.. Drill for drilling wall anchor holes. 3. Hand level. 4. Tape Measure. 5. Four anchors with bolts and washers, per enclosure. MAKING ELECTRICAL CONNECTIONS IMPORTANT PRECAUTIONS: Prior to mounting the controller and making any field connections: 1. Verify that the following information is compatible with other related equipment on the project: Patterson catalog number Motor horsepower, voltage, phase and frequency System pressure. The project electrical contractor must supply all necessary wiring for field connections in accordance with the National Electrical Code, the local electrical code and any other authority having jurisdiction. 3. Open the door of the enclosure and inspect the internal components and wiring for any signs of frayed or loose wires or other visible damage. PROCEDURE All field connections and AC wiring are brought into the enclosure through the bottom or side conduit entrances. Refer to the National Electrical Code, the local electrical code or any other authority having jurisdiction for proper conduit entrance location. 1. Use a hole punch, not a torch nor a drill, to punch a hole in the enclosure for the size conduit being used.. Install necessary conduit. 3. Pull all wires necessary for field connections, remote alarm functions, AC power and all other optional features. Allow enough excess wire inside the enclosure to make up connections to the appropriate line, load and control terminal block points. Be sure to consult the appropriate field connection diagram included with the manual. For proper wire sizing, refer to the National Electrical Code, NFPA 70. 4. Make all field connections to the remote alarm functions and any other optional features. Do not connect AC power. 5. Verify AC line voltage, phase and frequency with the controller data plate on the enclosure door prior to connecting AC power. 6. Connect the AC power. 7. Check to see that all connections are both correctly wired and tight. 8. Close the enclosure door.

Instructions Jockey Pump Controllers MAKING SYSTEM PRESSURE CONNECTION The controller requires one (1) system pressure connection from the system piping to the enclosure. The connection fitting is provided on the bottom, external side of the enclosure for this purpose. Refer to NFPA 0 (or Publication GF 100-30) for correct field piping procedure of the sensing line between the pumping system and the controller. VOLTAGE CHECK 1. Energize the incoming power feeder.. Measure the line voltage at L1, L and L3 at the top of the disconnect switch. Confirm that the measured voltage matches the voltage stamped on the data plate. SETTING START AND STOP PRESSURES The controller is furnished with a pressure switch to control the start and the stop sequence of the jockey pump. The Start Pressure is set by turning the screw located on top of the pressure switch. The Differential Pressure is set by turning the screw through the hole in the top of the pressure switch. The Stop Pressure is the sum of the start and differential settings (ex. Start @10 psi + differential @ 15 psi = Stop Pressure 135 psi). The upper (STOP) pressure setting must be set at a pressure less that the jockey pump churn pressures (including minimum suction pressure) otherwise the pump will run continuously once started. CONTROLLER OPERATION FPJPC Each controller has a HAND-OFF-AUTO selector switch mounted on the right-hand side for selection of Manual or Automatic operation. When placed in HAND, the motor starter is energized and the motor will run until the switch is placed in OFF. When the switch is placed in AUTO, the motor starter is energized by the pressure switch. Controllers may be furnished with optional Running Period Timers which operate in conjunction with the pressure switch. WITHOUT RUNNING PERIOD TIMER Controllers without running period timers start and stop automatically as determined directly by the pressure switch settings. WITH RUNNING PERIOD TIMER Controllers with Running Period Timers start automatically when the system pressure decreased to the pressure switch lower (START) setting and stop only after the timer has completed its timed cycle and the upper (STOP) pressure setting of the pressure switch has been reached.

R I I I STANDARD JOCKEY PUMP CONTROLLER NEMA TYPE 3R ENCLOSURE 3.00 (4) 1/4"WIDE X 1/"LONG HOLE Patterson Jockey Pump Control Panel Model No. Voltage H.P. Rating Serial No. Encl. Type FLA. A SUBSIDIARY OF THE GORMANN-RUPP COMPANY MADE in U.S.A. RU L 14.06 15.00 16.00 OF F AUT HAND O 1.01 8.00 SYSTEM PRESSURE CONNECTION 1/" [13] NPT PIPING, FEMALE NOTE: ADDITIONAL OPTIONS MAY INCREASE THE SIZE OF THE JOCKEY PUMP CONTROLLER ENCLOSURE. A TYPICAL STANDARD JOCKEY PUMP CONTROLLER ELECTRICAL SCHEMATIC L1 L1A T1 3-PHASE POWER FEED L L3 LA L3A T T3 MOTOR MSP1 C1 LEGEND MSP1 - MOTOR STARTER PROTECTOR C1 - CONTACTOR S1 - HAND-OFF-AUTO SELECTOR SWITCH PS1 - PRESSURE SWITCH, DIFFERENTIAL HAND (XOO) OFF AUTO 5 MSP-1 6 C1 (OOX) 4 4 5 S1 PS1 STANDARD RATINGS WIRE SIZE (CU) HORSEPOWER VOLTAGE PER PHASE 0.5-10 575/3/60 (1) #14 AWG (1) [.0 MM SQ.] 0.5-10 480/3/60 (1) #14 AWG (1) [.0 MM SQ.] 0.5-10 380/3/50 (1) #14 - #8 AWG. (1) [ - 8 MM SQ.] 0.5-10 40/3/60 (1) #8 AWG. (1) [8 MM SQ.] 0.5-10 08/3/60 (1) #8 AWG. (1) [8 MM SQ.] 0.33-10/1/60 (1) #10 AWG (1) [5 MM SQ.] 0.33-40/1/60 (1) #14 AWG (1) [ MM SQ.] NOTES: - ENCLOSURE MADE FROM 16 GA. STEEL. - ENTER EITHER TOP OR BOTTOM. - WALL MOUNTING. - STANDARD PADLOCKABLE DRAW LATCH NOT SHOWN. - MERCOID PRESSURE SWITCH CAN BE SUPPLIED AS AN OPTION. (REQUIRES A 16X1X8 ENCLOSURE) - STANDARD ENCLOSURE NEMA TYPE 3R. - FINISH: RED PAINTED BAKED ENAMEL FINISH. - INTERRUPTING CAPACITY 65kA UP TO 480VAC. - TRANSFORMER PROVIDED PER PRIMARY VOLTAGE REQUIREMENTS.

R JOCKEY PUMP CONTROLLER OPTIONS AND MODIFICATIONS OPTION A - PUMP RUNNING PILOT LIGHT 5 L1 OPTION H - ANTI-CONDENSATION SPACE HEATERS 10V SPACE HEATER W/ HYGROTHERM CONTROL 40V SPACE HEATER W/ HYGROTHERM CONTROL OPTION B - POWER ON PILOT LIGHT L ETF 01 1 11 N OPTION C - CONTROL TRANSFORMER: 08V/40V/380V/460V/575V PRIMARY, 10V SECONDARY 10 5 3 1 HTR 10V/1PH/60HZ N F F OPTION I - PUMP RUN REMOTE ALARM CONTACTS XFMR H N 16 C1-17 F1 OPTION J - AUXILIARY RELAY OPTION D - PHASE FAIL REMOTE ALARM 5 OR R1 OPTION K - POWER ON REMOTE ALARM CONTACTS R 19 0 1 F4 1A R-1 R- NOTES: A - TERMINALS 0, 1 SHOWS NORMAL POWER. TERMINALS 0, SHOWS POWER PROBLEM: POWER LOSS OR PHASE REVERSAL. MUST CHECK THE POWER MONITOR TO IDENTIFY POWER PROBLEM. PM 4 5 NOTE A 0 1 3 6 OPTION L - 300PSI, 10 VAC PRESSURE RECORDER RCRD OPTION M - PUMP FAIL TO START ALARM CONTACTS 0.1-60 SEC. C1-4 5 9 FTR 3 OPTION E - SPECIAL ENCLOSURES NEMA TYPE 3R NEMA TYPE 4 NEMA TYPE 4X NEMA TYPE 1 FTR-1 NORMALLY OPEN CLOSE TO ALARM OPTION F - SPECIAL CONDITIONS OPTION G - MINIMUM RUN TIMER 600PSI [0-4KG/(CM)(CM)] PRESSURE SWITCH (FOR FRESH WATER SERVICE) 300PSI [0-1KG/(CM)(CM)] PRESSURE SWITCH (FOR SEA WATER/FOAM SERVICE) 600PSI [0-4KG/(CM)(CM)] PRESSURE SWITCH (FOR SEA WATER/FOAM SERVICE) HORSEPOWER, HP.33 0.5 VOLTAGE, VAC 1OV 08V FREQUENCY, HZ 50HZ 60HZ PHASE 1 3 MRT-1 0.75 40V 4 MRT 5 N 10 6 N 1.0 1.5.0 3.0 380V 460V 575V ***NOTE: "OFF DELAY TIMER" ALSO AVAILABLE (NOT SHOWN). 5.0 7.5 UR L FLO-PAK IS LISTED BY ETL UNDER ELECTRIC INDUSTRIAL CONTROL EQUIPMENT FILE# 79045. ALL ASSEMBLY AND WIRING OF FLO-PAK CONTROL PANELS IS IN ACCORDANCE WITH UL 508 AND NATIONAL ELECTRIC CODE NFPA 70 STANDARDS. FLO-PAK CANNOT BE RESPONSIBLE FOR MORE RESTRICTIVE LOCAL OR REGIONAL CODES UNLESS SUCH CODES HAVE BEEN IDENTIFIED PRIOR TO FABRICATION. 10 15 0 5 30 40 50 SHIPPING WEIGHT (APPROXIMATE) 5 LBS. (9KG)

SELECTION DATA SHEET for JOCKEY PUMP CONTROLLERS FPJPC HORSEPOWER HP CAT. No. 1/ 1 3/4 34 1 1-1/ 01 11 HP 3 5 7-1/ CAT. No. 0 03 05 07 HP 10 CAT. No. 10 15 15 0 0 5 5 HP 30 CAT. No. 30 40 40 50 50 PHASE: 1 = SINGLE, 3 = THREE CURRENT: 50/60 HERTZ VOLTAGE: 10 08 30 380 415 460 OPTIONAL FEATURES: 1 PUMP RUNNING PILOT LIGHT POWER ON PILOT LIGHT 3 CONTROL CIRCUIT TRANSFORMER 4 PHASE FAIL/PHASE REVERSAL REMOTE ALARM 5 PUMP RUN REMOTE ALARM CONTACTS 6 AUXILIARY RELAY 7 POWER ON REMOTE ALARM CONTACTS 8 300PSI, PRESSURE RECORDER 9 FAIL TO START ALARM CONTACTS 10 RUNNING PERIOD TIMER 11 HOA NOT IN AUTO 1 MOTOR OVERLOAD OR MSP OFF T1 OFF DELAY TIMER MODIFICATIONS: SPECIAL ENCLOSURES: N N3 N4 H NEMA TYPE 4 NEMA TYPE 4X NEMA TYPE 1 ANTI-CONDENSATION SPACE HEATERS: H1 10 VOLT SPACE HEATER WITH THERMOSTAT AND HUMIDISTAT 40 VOLT SPACE HEATER WITH THERMOSTAT AND HUMIDISTAT SPECIAL CONDITIONS: P1 P P3 0-600 PSI (0-4 kg/cm ) PRESSURE SWITCH FOR FRESH WATER SERVICE 0-300 PSI (0-1 kg/cm ) PRESSURE SWITCH FOR SEAWATER/FOAM SERVICE 0-600 PSI (0-4 kg/cm ) PRESSURE SWITCH FOR SEAWATER/FOAM SERVICE EXAMPLE: FPJPC 1 3 60 460 1/ HP 3 PHASE 60 HERTZ 460 VOLTS STANDARD FEATURES: - BUILT TO NEMA STANDARDS - MAGNETIC MOTOR STARTER AND MSP WITH ADJUSTABLE OVERLOAD - THROUGH-THE-DOOR DISCONNECT SWITCH CONNECTED TO MOTOR STARTER PROTECTOR (MSP) - PRESSURE SWITCH WITH EXTERNAL SETPOINT ADJUSTMENT AND DEADBAND ADJUSTMENT - NEMA 3R ENCLOSURE COMPLETE WITH SAFETY DOOR INTERLOCK - HAND-OFF-AUTO SELECTOR SWITCH Patterson - Flo-Pak Jockey Pump Controllers are built to NEMA industrial standards and are UL 508 listed and ETL Certified. These controllers are intended for use with fire pump systems. The standard Jockey Pump Controller includes a diaphragm type pressure switch, and a magnetic motor starter and MSP with thermal overload and external reset switch button. The standard pressure switch has a range of 30-300 psi (.1 to 0.7 BAR) and is suitable for fresh water. This pressure switch is mounted inside the enclosure. The standard enclosure is a NEMA 3R enclosure painted with a red baked enamel finish. - BAKED ENAMEL FINISH

General Information Typical Pressure Sensing Line Connection Fire Pump Controllers & Jockey Pump Controllers NFPA 0 7-5..1 Water Pressure Control There shall be provided a pressure actuated switch having independent high and low calibrated adjustments in the controller circuit. There shall be no pressure snubber or restrictive orifice employed within the pressure switch. This switch shall be responsive to water pressure in the fire protection system. The pressure sensing element of the switch shall be capable of withstanding a momentary surge pressure of 400 psi (7.6 bar) without losing its accuracy. Suitable provision shall be made for relieving pressure to the pressure-actuated switch to allow testing of the operation of the controller and the pumping unit. [See Figures A-7-5..1(a) and (b).] (a) (b) For all pump installations, including jockey pumps, each controller shall have its own individual pressure sensing line. The pressure sensing line connection for each pump, including jockey pumps, shall be made between that pump s discharge check valve and discharge control valve. This line shall be brass, copper, or series 00 stainless steel pipe or tube, and the fitting shall be of ½ inch (1.7 mm) nominal size. There shall be two check valves installed in the pressure sensing line at least 5 ft. (1.5 m) apart with a 3/3 inch (.4 mm) hole drilled in the clapper to serve as dampening. [See Figures A-7-5..1 (a) and (b).] Exception No. 1: If water is clean, ground-face unions with noncorrosive diaphragms drilled with 3/3-in. (.4 mm) orifices shall be permitted in place of the check valves. Exception No. : In a nonpressure-actuated controller, the pressure-actuated switch shall not be required. (c) (d) (e) There shall be no shutoff valve in the pressure-sensing line. Pressure switch actuation at the low adjustment setting shall initiate pump starting sequence (if pump is not already in operation). A listed pressure recording device shall be installed to sense and record the pressure in each fire pump controller pressure-sensing line at the input to the controller. The pressure recorder shall be capable of operating for at least seven days without being reset or rewound. The pressure sensing element of the recorder shall be capable of withstanding a momentary surge pressure of at least 400 psi (7.6 bar) without losing its accuracy. A-7-5..1 Installation of the pressure-sensing line in between the discharge check valve and the control valve is necessary to facilitate isolation of the jockey pump controller (and sensing line) for maintenance without having to drain the entire system. [See Figures A-7-5..1 (a) and (b).] A-7.5..1(e) The pressure recorder should be able to record a pressure at least 150 percent of the pump discharge pressure under no-flow conditions. In a high-rise building this requirement can exceed 400 psi (7.6 bar). This pressure recorder should be readable without opening the fire pump controller enclosure. This requirement does not mandate a separate recording device for each controller. A single multichannel recording device can serve multiple sensors.