One & Two Stage Turbine Type Pumps

Similar documents
Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

900 Series Split Case Fire Pump Systems

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

3340 Series Single Stage End Suction Pumps

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

Regenerative Turbine Pumps

Regenerative Turbine Pumps

Index - Section 14 End Suction Pump Semi-Open Impeller

Regenerative Turbine Pumps

Regenerative Turbine Pumps

Regenerative Turbine Pumps

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

SMN Double-Suction Axially Split Pump

M50 L50 Series Multistage Regenerative Turbine Pumps

D51 D61 D71 D91 Series

Regenerative Turbine Pumps

Goulds 3640 ISO nd Edition/API th Edition API BB2 Two-Stage, Between-Bearing, Radially Split

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

SUGGESTED SPECIFICATIONS

High Temperature Chemical Process Inline Pumps

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

Basic Hydraulic Features. Basic Mechanical Features

Centrifugal End Suction Fire Pumps

RS Series Multi-stage, Ring Section Pump For Pressures to 1,500 PSI

4500C Series Vortex Pumps

Series 1510 Centrifugal Pumps

Hydropak Booster Systems. Series motralec

Goulds Small Capacity Double Suction Pump

CLOSED COUPLED CENTRIFUGAL PUMPS

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

CLOSED COUPLED CENTRIFUGAL PUMPS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

JOCKEY PUMPS MTH Tool Co. Series T41, T51, 150, 160 Regenerative Turbine Vane Type. TYPICAL SPECIFICATION MTH Tool Co. Series T41, T51 Pumps

PROCESS PUMPS MODEL V200 ANSI B73.2

340 Series Double Suction Split Case Pumps

RS Multi-Stage, Ring Section Pumps

EN. 850 Filtrate Pumps. Technical Specification Pages

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

VSC /VSCS Pumps Technical Brochure

Contents. Identification

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

CENTRIFUGAL PROCESS PUMPS MODEL A100 ANSI B73.1

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Waterfall Pumps Manufacturing

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Series

Bulletin D51 September D51 D61 D71 D91 Series. Centrifugal Pumps. Capacities to 240 GPM Heads to 360 Feet MTH PUMPS

Bristol: A History & Future.

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

University of Houston Master Construction Specifications Insert Project Name

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

SERIES CS CLOSE COUPLED TURBINE PUMPS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

320 Series Vertical Sump Pumps

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

barmesapumps.com WHAT IS AN ANSI PUMP

SERIES CS CLOSE COUPLED TURBINE PUMPS

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

SECTION H3 TRAYMASTER SERIES DEAERATORS

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

ITT. Goulds Pumps G&L Series NPO. Engineered for life. Commercial Water. Open Impeller All Stainless Steel End Suction Pumps.

Self-Priming Fiberglass Pumps

Cavern Electrical Submersible Pumps

GH General Horizontal, Close Coupled and Frame Mounted Pumps

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

MAN. Single-channel open impeller. motralec. electrical submersible pumps. General characteristics

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

HORIZONTAL MULTI STAGE PUMPS

AURORA MODEL 410 SERIES ENGINEERING DATA MECHANICAL SEALS AND PACKING

PWM. API 610 BB3 Multistage Pump

Series HSC-S Pumps Technical Brochure

Series 4600F. HSC Fire Pumps & Packaged Systems

1100 Series Multi-Stage Vertical Turbine Pumps

ANDRITZ High-Pressure Pump MP Series

PWD. PWD API 610 BB1 Single Stage Pump

Bulletin C Dean Pump Division. ANSI/ASME B73.1 Horizontal Process. ph2140 Telescoping Guard. ph2140 C-Face Adapter

HORIZONTAL SPLIT CASING PUMP

TYPE PC Propeller Condensate Pumps

SAMPLE SPECIFICATIONS

PWM API 610 BB3 Multistage Pump

Chempump. G Series. Canned Motor Pumps

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

ASME END SUCTION PUMPS Catalogue K-90

PWA ANSI / ASME B73.1 PROCESS PUMP

Bulletin BX-420C Bell & Gossett. VSC /VSCS Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Program

BSM ROTARY GEAR PUMPS

TECHNICAL BROCHURE BAC2000. Series 2000 Closed Coupled. Series 2000 Frame Mounted. Series A-C 2000 SINGLE STAGE END SUCTION

900 Series. 2000/2500 GPM High Head. Expanding our line to meet your needs. Model Latest Addition to the Aurora Fire Pump Line

CRANE-DEMING VERTICAL IN-LINE INDUSTRIAL BULLETIN 3180 SECTION 38

SERIES: WG6-2 SELF-PRIMING CENTRIFUGAL PUMPS

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

LPG Pump Catalogue. Auto Gas. Bottling. Transfer. Sterling Fluid Systems Group motralec

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

Goulds 3410 Small Capacity Double Suction Pumps

Transcription:

0A Series APO One & Two Stage Turbine Type Pumps apacities to 0 GPM Heads to 700 Feet Temperatures to 7 F Standard Bronze fitted construction Hydraulically balanced bronze impeller Right- or left-hand rotation Regreaseable ball bearings Optional Short bearing span Mechanical seals or graphite impregnated acrylic packing All iron, bronze ring or all bronze construction 6 stainless steel or Monel shaft 46 hardened stainless steel shaft External sealing line to stuffing box Floating impellers Lantern ring ( & 6 series 0) Removable channel rings Formed steel or drip-rim bases VIP Test Every pump is given a hydrostatic test at times rated pressure along with a running test for head and capacity performance check Bypass with manual shut-off valves Bypass with relief valve Self-priming features ertified performance test data can be supplied consisting of head, capacity and horsepower readings taken over the full operating range of the pump motralec 4 rue Lavoisier. ZA Lavoisier. 9 HERBLAY EEX Tel. : 0.9.97.6.0 / Fax. : 0.9.97.68.48 emande de prix / e-mail : service-commercial@motralec.com www.motralec.com

Aurora 0A Series Pumps Reliable Pumping Service Apco regenerative turbine pumps are field-proven throughout the world. Apco pumps are ideal for handling () high head/low flow requirements, () liquids entrained with gases and vapors (up to 0%), and () constant flows. You are assured of reliable pumping service because every Apco is tested to ensure consistent performance. onventional centrifugal pumps, in contrast, must operate close to shutoff or operate at high speed to meet these high head/low flow requirements. These misapplications can cause high vibration, mechanical damage, frequent maintenance, and excessive energy use. Apco pumps thrive in high head/low flow applications so you save on operating costs (less maintenance, downtime and energy costs). Pressure variations occur for a number of reasons. The most common designed-in variations are caused by automatic pop-off valves and similar control devices. With Apco pumps, you can always depend on the same capacity despite variations in head pressure and achieve increased system reliability. 00 Increase System Reliability with onstant Flow Apco pumps assure constant flow when you need it. The steep performance curve allows for minimal changes in the capacity even with large pressure variations. The constant flow characteristics make the Apco ideal for cooling systems where it is vital that sufficient flow is maintained to dissipate heat despite changes in pressure. 00 Ft Total ynamic Head - Feet Apco pumps are designed for those special applications where high head and low flow are required by the system. Boiler feed systems, for example, require high pressure to get low flows of water into the pressurized steam boiler. 400 00 00 00 0 4 6 8 apacity - GPM 0 GPM The curve above shows that with a 00 foot change in head, the capacity varies only gallons per minute. You get a virtually constant flow over wide pressure variations to ensure reliable system operation.

Aurora 0A Series Pumps Applications Boiler Feed ondensate Return ooling Systems Top vertical discharge is self venting High Pressure Spray Booster Systems Jockey Pumps hlorine Injection hemical Feed Systems Laundry and ry leaning Systems Large stainless steel shaft for minimum deflections and corrosion resistance Packing External water seal connection Mechanical seals Regreaseable ball bearings Laser ooling Electrostatic ischarge Machines TV Tube and RT Manufacturing ar Washes Benefits Reliability Years of Field-proven Service Reduce Energy onsumption Water slinger Trouble-free Operation High Performance Save Space Versatility Seal cover Packing cover Typical Two-Stage Unit Shown Short bearing span ouble suction impeller (bronze) minimizes axial thrust omplete Technical Support Low Flow/High Head apabilities Limitations Max. hydrostatic test pressure... 40 psi except ---... 6 psi Max. case working pressure... 00 psi except ---... 7 psi Max. suction pressure... 7 psi except two stage 6 Series with optional 0 lb. suction flange... 00 psi Max. recommended packing box pressure. 00 psi Max. recommended mechanical seal chamber pressure... 0 psi except 4A, 4R, 4RTL... 0 psi Two stage: st stage equals suction pressure plus 0% differential, nd stage equals suction pressure plus 80% differential. Max. temperatures *Packing... 7 F Std. mechanical seal... F Hi-temp mechanical seal...7 F *Packing...Suction lift requires lantern ring, and 6 Series only. Box or seal chamber pressure equals One stage: suction pressure plus 60% differential pressure.

Selection harts 70 RPM apacity GPM 0 0 0 40 0 60 70 80 90 00 0 0 Total ynamic Head in Feet 0 0 0 40 0 60 70 80 00 0 4 60 80 00 0 40 60 80 00 0 400 40 00 L M N N P L M N P P A L N N P P A L N P P P A L L N P P P A A A L N N P P P A A L N P P P A A L L N P P P L L P P P P 0 E4 L L L P P P P 0 0 J K L L P P P P 0 0 I J K L L P 0 P 0 P 0 0 0 0 T I J L L L P 0 P 0 0 0 0 T T I K L L P 0 P 0 0 0 0 T T J K L L P 0 0 T T T I J L L L 0 T T T I K L L 0 0 T 0 0 T T I L L L 0 0 T 0 T 0 0 T T T I I L 0 L 0 0 0 0 T 0 T 0 0 T T H I I L 0 L 0 0 0 T 0 T 0 T 0 T T H I L L 0 0 0 T 0 T 0 E4T T GT HT IT IT T T T T GT HT 6T 0 6T 0 0 0 T 0 T GT HT IT 6T 0 0 0 esign etails Area Stuffi ng Box Shaft Ball Bearings 0-Series Pump Model A T I T J P IT 6T imensions Packing Rings Per Box 4 7 7 8 Packing Size (Square) 4" 9 " 4" 4" 6" Outside iameter of Shaft.90.787.787.984.8 Inboard Radial 0 04 04 0 06 Outboard Thrust 00K 0K 0K 04K 0K 00 RPM apacity GPM 4 6 8 0 4 Total ynamic Head in Feet 0 00 0 00 0 00 0 400 40 A A A A A A 4

Pump imensions Type 4 & Series Type 6 Series A NPT I-ISHARGE NPT I-ISHARGE A S-SUTION # FLANGE I-ISHARGE # FLANGE I-ISHARGE 0# FLANGE NPT SUTION B B 4R, 4RA, R, RA 4R, 4RA, R, RA 4RTL, RTL 6RA, 6RTL, 6RATL 6RA 6RTL, 6RATL SINGLE STAGE TWO STAGE 4R A,,,,, E4 T, E4T, T, T, 4RA,,,,,, NEMA 70 4RTL T, Motor RPM Unit ischarge ¼ Suction ¼ Unit ischarge Suction Frame HP Unit ischarge ¼ Suction ¼ Weight A B Weight A B Weight A B 86 4 4 7 7 4 9 6, 4 9 66 4 7 08 4 9 4T 0 4 9 7 4 7 6 4 9 4T 0 4 4 9 9 4 4 9 6 7 4 0 8T 6 4 0 00 4 9 8 4 0 84T 6 4 0 6 7 4 4 0 9 0 4 4 T 9 8 4 4 8 9 4 4 0 4 4 T 0 0 4 4 R, E, F, G, H, I RA J, K, L, M, N, P NEMA 70 RTL T, ET, FT, GT, HT, IT Unit ischarge ¼ Suction ¼ Unit ischarge Suction Motor RPM Unit ischarge ¼ Suction ¼ Weight A B Weight A B Frame HP Weight A B 8 9 6, 6 0 8 8 0 4T 8 8 0 6 7 0 9 0 4T 9 0 6 8 0 4 0 0 8T 4 0 0 9 0 48 0 84T 48 0 9 6 6 4 6 T 4 6 9 6 4 6 T 0 4 6 6 8 47 8 8 4T 46 8 8 7 8 8 8 40 8 6T 0 8 40 8 6RA,,, NEMA 70 6RTL 6T,, 6RATL,, T, Unit ischarge Suction Motor RPM Unit ischarge Suction Unit ischarge Suction Weight A B Frame HP Weight A B Weight A B 4 8 6 8T 64 7 6 8 7 7 49 6 8 6 84T 69 6 7 6 0 9 7 7 4 8 9 6 T 6 8 8 6 90 4 7 7 6 40 9 6 T 0 8 40 8 6 40 4 7 7 46 4 9 6 4T 46 4 8 6 490 46 7 7 47 4 8 6 6T 0 49 4 7 6 48 7 7 4 46 9 6 84T 6 46 8 6 8 49 8 7 7 48 9 6 86T 0 9 47 8 6 649 0 9 7 8. imensions and weights are approximate.. imensions are in inches and may vary ± /8".. Not for construction purposes unless certified. 4. Frame sizes shown are for open dripproof motors only.. onduit box is shown in approximate position. imensions are not specified as they vary with each motor manufacturer. 6. All flanges are standard flat face. NOTES:. Selections indicate pump size in upper portion and motor HP in lower portion of each block.. A,,, and pumps are also available for 00 RPM operation. See table on page 4.. Maximum suction pressure is based on suction flange pressure rating. 4. All limitations are based on standard pumps constructed of standard materials and handling water.

Engineering Specifications The contractor shall furnish (and install as shown on the plans) an Apco regenerative turbine type pump model size (Bronze Fitted) (Bronze Ring) (All Iron) (All Bronze). Each pump shall have a capacity of GPM when operating at a total head of feet at the specified temperature, viscosity, specific gravity, and NPSH. The speed of the pump shall not exceed 70 RPM. (Models A,,, and can also be operated at 00 RPM.) The pump is to be furnished with (mechanical seals) (packing). The pump shall be of vertically split case design with removable bearing housings, and the channel rings shall be replaceable without replacing the bearing housings. The suction and discharge connections shall be cast integral with the casing. The discharge shall be in a vertical position and the pump shall be self-venting. The casing and bearing housings shall be cast of 0,000 pound tensile strength cast iron. The impeller(s) shall be located on the stainless steel shaft between grease lubricated ball bearings. The impeller shall be hydraulically self-centering and no external adjustment shall be necessary. Each pump shall be tested prior to shipment. The pump shall be mounted on a (steel drip rim) (steel) baseplate and flexibly coupled to a HP phase, hertz, voltage, RPM, horizontal (dripproof) (totally enclosed) (explosion proof) motor. The motor shall be sized to prevent overloading at the highest head condition listed in the specifications. Materials of onstruction Retainer Nylon Bearing overs ast Iron ASTM 8 asing ast Iron ASTM 8 hannel Rings ast Iron ASTM 8 Glands ast Iron ASTM 8 Impellers Bronze ASTM B6 Packing Graphited Tefl on Fiber Shaft Stainless Steel AISI 46 Maximum ifferential Pressure Pump Sizes psi 90, 00 0,,, P,, T, H, I, M, N, 0 L 7 A,,,,,E4,,,, T 00 K 0 G J 0 T,, E, F, HT, IT, T, 0 T, E4T, T, ET, FT, GT,6T,,,, 00 NOTE: Maximum differential pressure based on allowable shaft deflection for standard shafts. Maximum Horsepower Pump Sizes HP E4,,,,,, T,E4T, T, T, T, 4 A,,,,,,,, E, F, G, H,I, T, ET, FT, GT, HT, IT 0 J, K, L, M, N, P 0,,,, 6T,,,,, T, 40 motralec 4 rue Lavoisier. ZA Lavoisier. 9 HERBLAY EEX Tel. : 0.9.97.6.0 / Fax. : 0.9.97.68.48 emande de prix / e-mail : service-commercial@motralec.com www.motralec.com HYRAULI 9 INSTITUTE 7 ISO 900 REGISTERE QUALITY SYSTEM A-0-004 07.0