INSTRUCTION MANUAL. Direct Drive Air Compressor 2320, REV A. 1.

Similar documents
INSTRUCTION MANUAL. Portable Greasing System S1180, REV C GS

High Accuracy Mechanical Fuel meter FM-100

INSTRUCTION MANUAL. Electric Drum Pump S2180, REV C EDR

Air Operated 1:1 Oil Ratio Pump OP-11

Air Operated Grease Ratio Pumps 50:1 BGRP

Electric Fuel Pump FPM

IMPACT & RATCHET WRENCHES. Create an impact! CAT 600

Electric Fuel Pump FPM

Electric Diesel Pump EDP/12, EDP/24

FLOODLIGHTS SITE LAMPS SPOTLIGHTS WORKLIGHTS HEAD LIGHTS FLASHLIGHTS

6 Litre Oil-Less Air Compressor

Portable Electric/Gas Compressor Operating Instructions

6L Oil-less Air Compressor 53103

Belt Driven Compressor Operation Manual Model No. SACBD-100

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Installation & Operation Manual

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

HOFFMANN POWER PRODUCTS PARTS LIST 2014

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

OWNER S TECHNICAL MANUAL

Air Compressor. Models: CFP9HND. Operating & Maintenance Instructions

Portable Oil Free Silent Series Compressor Operating Instructions

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 -

ROYCE AIR COMPRESSOR 415VOLT/3 PHASE OPERATIONS MANUAL

AIR COMPRESSORS AND PNEUMATIC TOOLS.

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

1100W PORTABLE GENERATOR

User s Manual. Table of Contents CAUTION. Model No. MTSC11700

D Instructions/Parts. Siphon Feed Detail Spray Gun D

WARRANTY. Illustration

Automotive Air Conditioning Manifold Gauge Sets

WARRANTY. Illustration

VT Oil-Free Range Operators Handbook

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

PROMPT TRADING CO. Ph. No.:

Congratulations PRE-OPERATION SETUP

Heavy Duty Sprayer Owners Manual Model MS-O

Super T QR20 INSTRUCTIONS GENERAL RULES

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

Backpack Sprayer. Use and Care Manual

AC3020B AC3030B PORTABLE AIR

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

PARTS LIST FOR AIR COMPRESSORS AC-SH20-2 AC-SV20-2 ENGINE OIL GRADE: HONDA: SAE 10W-30. Below 40 F=SAE 10W-30 ENGINE OIL CAPACITY:

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

CT0866 ORIGINAL INSTRUCTIONS SAVE

WARRANTY. Illustration

Air Compressor PP10ND PPH10ND PP15ND PPH15ND. Operating & Maintenance Instructions

Iron Horse Air Compressor part breakdown - IHD6160V1 Item Description IHD6160V1 IHD6160V1 Call for the Customer Service Department.

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Hand Pallet Truck NC. Operation Manual

ENGINE DRIVEN 3 FULL TRASH PUMP

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

Compressor Operation and initial start up Procedure: Please read directions carefully and follow operatingproceduresbeforeeachuse.

MAINTENANCE PROCEDURE FOR MK17

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

Medusa Compact T3001 Generator

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

Ph: (07) Fax: (07) Pump Manual

STIGA TORNADO 51 S 51 SE PRO 51 S

Corken Compressor Repair

OPERATOR S MANUAL StudPro LiteXI Pin Welder Stud Welding Products, Inc

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

USE and MAINTENANCE INSTRUCTION MANUAL W-300 W-300 WB LPH-300 GRAVITY. SPRAY GUN Series. en it fr es pt de se

T1-Titanium Non-HVLP Spray Gun

3000 SERIES DRY-BLOCK HEAT SOURCE

Electric Pressure Washer

* * * * 8 Maintenance Plan 10.1,10.2, ,4 7.1/7.2/7.3

MONZA OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

Marzocchi Suspension D-Street 24" D-Street 24" Technical instructions

February 26, ch.12.notebook. Ch. 12. Preventative Maintenance and Troubleshooting. Feb 23 5:03 PM

DEWALT 950-C. Reciprocating Air Compressor Dual Cylinder. DeWALT 950-C DEWALT. 210 Bath Road. United Kingdom COPYRIGHT 2011 DEWALT.

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10.

Features. Marathon SL TECHNICAL CHARACTERISTICS. Sliding bushes: made of friction free and wear free material.

Medusa T1101 Generator

TS1251 PRESSURE DISPENSER USER'S MANUAL

FB 300 FB 450 FB 700 USER MANUAL

Competitor. Ultra Light Plus, Semi Electric Bed. Item # 15560, HR Owner s Assembly And Operating Manual

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

STIGA DINO 45 EURO TORNADO

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

F B F B USER MANUAL. spac100. Dok: A-GB 0820

Owner's Manual. Model: ( ) (150 Gallon, 5.5 HP Skid Sprayer) Technical Specifications. General Information. Warranty/Parts/Service

Operation Manual Model: PPSSS Submersible Slurry Pump

Dependable Performance. Reciprocating Air Compressors

Transcription:

INSTRUCTION MANUAL 2320, REV A Direct Drive Air Compressor CONSTRUCTION DUAL MATERIAL CONSTRUCTION i) The cylinder block is made up of cast iron that prevents wear & tear thus imparting longevity to the unit ii) Crankcase & cylinder head are made from aluminium Compact design and choice of aluminium as a raw material helps in efficient cooling of the unit. Aluminium crankcase keeps the oil in the sump cooler thus enhancing performance. Pump head directly coupled with the motor for reliable and quiet operation. FEATURE Two pressure gauges, one for pressure setting in the receiver and one for controlling the outlet pressure from the receiver. Pressure switch with overload protection keeps the compressor safe even in voltage fluctuations. Oil dipstick with vent hole keeps a check on oil level in the oil sump and releases excess pressure. Pressure regulator regulates the outlet pressure from the tank. Plastic shroud Aluminum Cylinder Head Air Filter Direct driven with full cast iron cylinder block Oil dipstick Large oil crankcase for enhancing performance operation Receiver Tank Large 5" (125 mm) dia. wheels Starter Unit Pull handle Pressure regulator Two Pressure Gauges for controlling Pressure in the tank and output pressure PU rectractable hose Solid shock absorber feet Plastic shroud keeps the hot and moving parts safe and prevents any accidents. FIG. 1 Shock absorber pad effectively absorbs the vibration generated during operation and keeps the whole unit stable. Large wheels enhance the portability of the compressor. Supplied with Polyurethane retractable hose for attaching any equipment such as Blow gun, Paint spray guns, Tyre inflater etc. APPLICATION Suitable for general purpose workshop applications. Used for spraying (Automotive bodywork, fences, sheds), nailing / stapling & cleaning etc. Ideal for powering spray guns, air tools and a wide range of airline accessories for inflating, blowing, cleaning etc. SPECIFICATIONS DESCRIPTION MOTOR RATING 1.5 KW, 2 HP CYLINDER 1 STAGE 1 AIR RECEIVER CAPACITY 24 litres RPM 2850 FAD (FREE DELIVERY) 170 LPM / 6 CFM MAX. PRESSURE 116 PSI / 8 BAR NOISE LEVEL 80 db WIDTH 610 mm DIMENSIONS DEPTH 310 mm HEIGHT 580 mm WEIGHT 24 kg ELECTRIC SUPPLY 230V, 1 Phase, 50 Hz. www.groz-tools.com info@groz-tools.com 1

BEFORE INSTALLATION EXTENSION CORD Use only the extension cord that has two-pole receptacles that accept the compressor s plug. Replace or repair damaged cord. Make sure the extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current that the compressor will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table shows the correct size to use depending on the area of cord and ampere rating. HP KW 220 / 230V 110 / 120V 2. Fill the crank case with the synthetic oil provided with the pack (FIG. 5). FIG. 5 3. Make sure that the the oil is filled only upto max. level as shown in (FIG. 6). 2 1.5 2.5 mm 2 4-6 mm 2 Never use this compressor with a damaged or frayed electrical cord or extension cord. Inspect all electrical cords regularly. Never use near water or in any environment where electric shock is possible. INSTALLATION 1. POSITIONING 1. Remove the compressor from its FIG. 2 Do not over fill or under fill the crankcase 3. ELECTRICAL CONNECTION Single phase compressor is supplied with an electrical cable and a two - pole + earth plug. The compressor must be connected to a grounded power socket (FIG. 7). FIG. 6 FIG. 7 MAX MIN OPERATING THE COMPRESSOR packing, make sure it is in perfect condition (Fig. 2). 2. Position the compressor on a flat surface or on a maximum permissible inclination of 10, in a well ventilated place, protected against atmospheric agents. 3. If the surface is inclined and smooth, check if the compressor moves while in operation- if it does, secure the wheels with two wedges on its wheels. 1. Before starting the compressor, check that the electricity supply to the compressor is in accordance to the specification label on the compressors tank (FIG. 8). 2. Compressor can be switched ON by pulling the plug on the pressure switch (FIG. 9). FIG. 8 4. If the surface is a bracket or a shelf top, make sure it does not fall, securing it in a suitable way. 5. To ensure good ventilation and efficient cooling, the compressor must be placed at least 1m away from any wall. 6. Connect the Polyurethane air hose with outlet of the compressor Take care while transporting the compressor, do not overturn it or lift it with hooks or ropes (FIG. 3). FIG. 3 FIG. 9 3. Compressors works on a pressure range of 2 Bar. The default setting of the compressor is max. 8 bar and min. 6 bar 4. Pressure switch automatically switches OFF the compressor when the pressure inside the tank reaches 8 bar and it automatically switches ON again when it reaches 6 bar. Note: The pressure range can be varied with the help of the screw inside Starter unit. 5. Manually push the On/Off button down to switch off the compressor when not in use. OUTLET PRESSURE SETTING 2. FIRST TIME OIL FILLING 1. Pull the oil dip stick from the crank case (FIG. 4). FIG. 4 The compressor is capable of producing 8 bar maximum pressure but there are times when the air pressure required is less than the maximum pressure. Air regulator provided at the outlet can be used to regulate the outlet pressure. Steps to set the outlet pressure: 1. Pull the adjustment knob on the regulator (FIG. 10). MAX MIN FIG. 10 2 www.groz-tools.com

2. Rotate clockwise to increase the outlet pressure and anticlockwise to reduce the outlet pressure. 3. Push the adjustment knob down to lock the pressure setting. Some pressure regulators do not have push to lock, therefore simply turn the knob to adjust the pressure. 2. Clean / Replace the filter element a. Pull out the Sponge filter element and soak it into a water bucket and retract and squeeze till all the water content is squeezed out and then reassemble the whole filter unit. b. Replace the sponge Filter element with a new element, if required. MAINTENANCE ADJUSTING THE PRESSURE RANGE 1. Remove the black lid present on the top of the pressure switch cover below the On/ Off switch (FIG. 11). Black Lid FIG. 11 2. Unscrew the bolt inside the lid hole and pull out the cover. 3. Tighten or loosen the hexagonal bolt using a size 10 spanner depending on the pressure requirement. Before attempting any maintenance jobs on the compressor, make sure of the following Master power switch is in switched off position. Pressure switch and the control unit switches are all off. Make sure there is no pressure inside the air tank. Refer Draining the condensate. OIL CHANGES TOPPING UP WITH OIL The compressor is filled with synthetic oil. For Example: If the compressor has 8 bar maximum switch Off limit and 6 bar minimum switch On limit, this can be changed to 7 bar maximum and 5 bar minimum. Remember that the range will always be of 2 bar between the maximum and the minimum level. Note: 1. Clockwise rotation of the hexagonal bolt increases the pressure and anticlockwise rotation will decrease the pressure. 2. Start the compressor to check the maximum switch Off limit then release the pressure to check the switch On limit. Repeat step 1 to reach the desired pressure setting. Unscrew the oil drain plug on the oil sump, allow all the oil to flow out, and re-screw the plug (FIG. 14). Pour oil into the upper hole of the oil sump until it reaches the level indicated on the stick. (FIG 15). FIG. 14 DRAINING THE CONDENSATE 1. Unscrew the drain valve present at the bottom of the air receiver tank (FIG. 12). FIG. 15 2. Allow all the water to flush out through the drain valve. 3. Screw the drain valve back. NOTE: Drain valve can also be used to empty the tank. CLEANING OR REPLACING THE FILTER FIG. 12 1. Unscrew the nut on the air filter to disassemble the filter body (FIG. 13). FIG. 13 Once a week: check oil level of the pumping element and see if it needs topping up. For operation at ambient temperature in the range -5 C to +40 C, use synthetic oil. The advantage of this oil is that is does not lose its characteristics either in winter or summer. Do not drain used oil into the sewer or dispose off in the environment. FOR OIL CHANGES TYPE OF OIL: Mineral Multi-grade (SAE 15 W40) with 100 hours duty. Synthetic Oil with 500 hours duty. NOTE: It is recommended to change the oil after first 100 hrs of operation. info@groz-tools.com 3

MAINTENANCE INSTRUCTION EVERY 50 OPERATING HRS INSPECTION SCHEDULE MAINTENANCE ACTION Drain the water condensate collected in the air receiver using the Drain valve. Clean the air filter element (required only when the compressor is used in dusty environment). Check the oil level from the Dipstick and refill up to the max Dipstick level if required. EVERY 100 OPERATING HRS EVERY 500 OPERATING HRS THERE IS NO OUTPUT Clean the air filter element (even if the compressor is not used Change the lubricating oil if normal lubricating oil is used. Fill the oil only upto the max. Dipstick level. Change the air filter element. Check the operation of the compressor at rated Pressure. Check all the couplers and fasteners for proper tightness. Change the lubricating oil if Synthetic lubricating oil is used. Fill the oil only upto the max. Dipstick level. in dusty environment). EXPLODED VIEW 4 www.groz-tools.com

REPAIR KIT PART NO. SR. NO. DESCRIPTION QTY. SUPPLY CONDITION KIT/RPR/FLT/RAC/DD/2-11/24 (filter kit) KIT/RPR/PLT/RAC/DD/2-11/24 (valve plate kit) KIT/RPR/GST/RAC/DD/2-11/24 (seal kit) KIT/RPR/PST/RAC/DD/2-11/24 (piston kit) KIT/RPR/IHOS/RAC/DD/2-11/24 (infeed hose kit) 1.1 Plate 1 loose 1.2 Filtering Element 1 1.3 Intatake Filter 1 1.4 Screws ST4.2 x 19 1 2.1 Gasket 1 loose 2.2 Valve Plate 2 2.3 Gasket 0.2 mm 1 2.4 Valve 2 2.5 Gasket 0.5 mm 1 3.1 Gasket 1 loose 3.2 Gasket 0.5 mm 1 3.3 Gasket 1.5 mm 1 4.1 Piston Ring 1 loose 4.2 Piston 1 4.3 Piston Pin 1 4.4 Internal Snapring 2 4.5 Con Road 1 5.1 Ogive 1 loose 5.2 Nut M16 1 5.3 Infeed Hose 1 5.4 Nut 3/8 G 1 TROUBLESHOOTING Air losses. PROBLEM POSSIBLE CAUSE SOLUTION This trouble is caused by poor tightening of the check valve. These can be caused by loose joints. Discharge all pressure from the tank. Refer Draining the condensate Unscrew the hexagon-head of the valve. Carefully clean both the rubber disk and its seat. Refit all parts accurately. Check all joints by wetting them with soapy water and probing for any leaks. Compressor not starting. There is no electric supply Connect the compressor to the power source. Power supply is not according to the model. Use supply according to the data plate. Compressor not stopping Power cable extensions are not of adequate diameter or length. If the compressor does not stop when maximum pressure has reached, the tank safety valve may not be working. Refer Extension cord Table. Contact the service centre There is no air output Air filter may be blocked. Clean or replace the filter. info@groz-tools.com 5

Groz Engineering Tools (P) Ltd. Groz Net Industries Village Kherki Daula, National Highway-8, Gurgaon-122001, Haryana, INDIA Tel +91.124.282.7734/40, 2827777 Fax +91.124.2827980, 2827986 E-Mail india@groz-tools.com Url www.groz-tools.com The GROZ name, GROZ logo and the mark are trademarks of Groz Engineering Tools (P) Ltd., India