Tightness control TC. Product brochure GB Edition 12.10

Similar documents
3 Edition Product brochure GB AGA

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Solenoid actuator MB 7 and butterfly valves BVHM

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Solenoid valves for gas VAS, Double solenoid valves VCS

Solenoid valves for gas VAS, Double solenoid valves VCS

Solenoid valves for gas VAS Double solenoid valves VCS

Combination controls CG 10

Butterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS

Butterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS For gas, air, hot air and

Solenoid valves for gas VAS, Double solenoid valves VCS AGA

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Solenoid valves for gas VAS, Double solenoid valves VCS

Actuators IC 40. Product brochure GB 3 Edition 02.16

Actuators IC 20, IC 40

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Valve monitoring system VDK 200 A S02

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Safety 0 50 Please read and keep in a safe place Operating instructions Solenoid valve for gas VAS 1, double solenoid valve VCS 1

Old documentation - Only for your information! Product is not available any more!

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 12.

Checking the usage. Slow opening/slow closing damping unit:

Modular test system for diaphragm gas meters with critically operated Venturi nozzles

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

Manually operated safety shut-off valve HSAV HSAV/5

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Safety. Operating instructions Protective system control FCU 500 DANGER. Contents WARNING CAUTION. Changes to edition 08.12

SERIES 2000 GAS SAFETY SHUT OFF VALVE

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VE4000 & VE5000 SERIES

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

3/2-way Solenoid Valve for pneumatics

Potential Danger of Fire or Explosion Read this letter now!

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

PGM Prepiped Gas Manifold

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Eclipse RatioAir Burners

Product data sheet. Series 210, DN (2½ - 6 ) Ordering No PE

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

CONA -control Monitoring system for steam traps

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

G72x Series Direct Spark Ignition Controls

Gas Pressure Governors

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

Maxon Shut-Off and Vent Valves General Purpose

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Grease Lubrication Pump FK

A E R Z E N S C R E W C O M P R E S S O R S

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Two-stage safety solenoid valves ZRLE/5, ZRDLE/5

Linear Valve Electric Actuator

Safety Shut-off Valve SL/SID/RSL

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Flame arresters 4301A/4319A ATEX Approved

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Proportional Pressure Reducing Valve PDM08130

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

TECHNICAL DATA 1-1/2 (dn40)

Features 1. Differential Latch-type, lightweight, dependable

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Examples 3/2-way valve A T NO: Symbol

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

Single-Line Centralized Lubrication Systems

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Pilot Operated Pressure Relief Valve Series R5V (Denison)

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

ONE STAGE GAS BURNERS RDBS SERIES

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Specifications of MAXON VALUPAK burners for 50 Hz operation

Redundant Control System

Safety. Operating instructions Protective system control FCU 500 Furnace zone control FCU 505 DANGER. Contents WARNING CAUTION

Transcription:

Tightness control TC Product brochure GB 3.1.5. Edition 1.10 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems Adjustable test instant allows quick system start Maximum safety thanks to self-monitoring electronics Less space required thanks to small dimensions EC type-tested and certified FM approved and UL listed www.kromschroeder.com

TC Edition 1.10 TC 1: for attachment to valvario controls and CG : for quick opening individual valves TC 1 mounted to a combination control CG on a heating boiler installed separately from the system in a control cabinet TC 1, Application The tightness control TC checks the fail-safe function of both valves before each start-up or after each shut-down of a system with two safety valves. The aim is to identify an inadmissible leak on one of the gas valves and to prevent burner start. The other gas valve continues working properly and takes over the safe shut-off of the gas supply. It is used in industrial thermoprocessing equipment, in boilers and forced draught burners. European standards EN 746- and EN 676 stipulate tightness controls for capacities over 100 kw (NFPA 86: from 117 kw or 400,000 Btu/h in conjunction with a visual indicator). Pre-purge of the combustion chamber can be dispensed with under certain conditions in accordance with EN 746-, if a tightness control is used. In this case, the system must be vented into the open air. TC 1 Tightness control TC 1 can be directly mounted to all CG combination controls. There is only one version for all sizes. The pre-set test period applies to all CG variants. In addition, TC 1 can be used for valvario controls, VAD and VAG with separate adapter plate. and Tightness controls and can be used with gas solenoid valves of any nominal size, which are quick opening or slow opening with start rate. It is possible to conduct a tightness test on pneumatically operated or slow opening valves without start rate by using additional auxiliary valves. Slow opening motorized valves VK up to DN 65 which are directly flanged together can also be checked by and within a temperature range of 0 to 60 C (3 to 140 F). Tightness control consists of detection circuitry and can be installed in the control cabinet, separately from the system. An external pressure switch takes over the mechanical pressure test between the valves. Tightness control is independent of gas type and inlet pressure and can be used for a test period of up to 10 minutes with a large test volume. Tightness control is a universal device for quick and slow opening gas solenoid valves of any nominal size as well as for motorized valves. The tightness test is carried out with the valves installed in. : for quick or slow opening or manually resettable individual valves : for control cabinet installation in a gas inlet section between a quick opening and a slow opening gas solenoid valve VG for tightness control on gas motorized valves VK installed in control cabinet by securing the lower section with screws or snapping it on to a DIN rail

TC Edition 1.10 3 Examples of application TC 1 VAD TC 116V 1 3 B TC 116V with valvario controls Tightness control TC 1 checks gas solenoid valves and for tightness. If both valves are tight, the tightness control forwards the enable signal to the automatic burner control unit. This opens valves and simultaneously. The burner starts. and : quick or slow opening valves with start rate. CG TC 116W 1 3 B TC 116W with combination control CG..D or CG..V The tightness control is directly mounted to combination control CG..D or CG..V. control forwards the enable signal to the automatic burner control unit. This opens valves and in the combination control CG simultaneously. The burner starts. and : quick opening valves. TC 1 CG CG..Z VZ TC 116W with two-stage combination control CG..Z control forwards the enable signal to the automatic burner control unit. The pilot valve output of the automatic burner control unit opens valves and in the combination control simultaneously. The burner starts. The main valve output opens the two-stage valve VZ, independently of TC 116W. TC 1 and : quick opening valves. 1 3 5 6 A 1 3 B TC 116W CG..Z VZ 1 3

4 TC Edition 1.10 Examples of application 1 3 5 6 A 1 3 B with two gas solenoid valves Tightness control checks gas solenoid valves and for tightness. If both valves are tight, the tightness control forwards the enable signal to the automatic burner control unit. This opens valves and simultaneously. The burner starts. and : quick or slow opening valves with start rate. 1 3 B with two gas solenoid valves and one pilot gas valve Tightness control checks the gas solenoid valves for tightness. The test volume is discharged into the combustion chamber. Auxiliary valve can be used as a pilot gas valve. control forwards the enable signal to the automatic burner control unit. The pilot valve output of the automatic burner control unit opens the gas solenoid valves and simultaneously. The main valve output opens gas solenoid valve. The burner starts. and : quick or slow opening valves with start rate. : quick opening, nominal size is dependent on test volume and inlet pressure, but is at least DN 15. p e 1 3 B with two gas solenoid valves and one auxiliary valve for discharge Tightness control checks the gas solenoid valves and and the auxiliary valve for tightness. If all the gas solenoid valves are tight, the tightness control forwards the enable signal to the automatic burner control unit. The pilot valve output of the automatic burner control unit opens the gas solenoid valves and simultaneously. The burner starts. A relief line is used to discharge the test volume into the open air via the roof. Thanks to the installed auxiliary valve, valve can also be a slow opening motorized valve VK. : quick or slow opening valves with start rate. : any. : quick opening, nominal size is dependent on test volume and inlet pressure, but is at least DN 15.

TC Edition 1.10 5 V4 DG in a multiple burner system with 3 valves installed in series When using slow opening main gas solenoid valves ( and ), auxiliary valves ( and V4) must be used for the supply and discharge of the test volume V p. Tightness control checks the central shut-off valve, the gas solenoid valve and the auxiliary valves and V4 for tightness. Valve can only be checked for tightness when the pressure downstream of approximately corresponds to the atmospheric pressure. The gas solenoid valve and the pressure switch DG are used to relieve the pressure. The pressure switch must be adjusted in such a way so that enough pressure is relieved and no air can get into the pipework. 1 3 B control opens the main gas solenoid valves and with the enable signal and enables the downstream burner control units. and V4: quick opening, nominal size is dependent on test volume and inlet pressure, but is at least DN 15. DG V4 with two gas solenoid valves Tightness control checks the slow opening gas solenoid valves or motorized valves VK for tightness using the auxiliary valves installed in. p a control forwards the enable signal to the automatic burner control unit. The pilot valve output of the automatic burner control unit opens valves and simultaneously. The burner starts. and : any. with a manually resettable valve Valves, which are manually reset, cannot be opened by the tightness control. The tightness test is then carried out using an additional auxiliary valve. p a Tightness control checks the tightness between the manually resettable valve and gas solenoid valve using the auxiliary valves installed in. Once the tightness test has been carried out successfully, forwards the enable signal.

6 TC Edition 1.10 DG in a multiple burner system Tightness control checks the slow opening main gas solenoid valves and for tightness. The test volume V p is supplied and discharged via the auxiliary valves. Valve can only be checked for tightness when the pressure downstream of approximately corresponds to the atmospheric pressure. The gas solenoid valve and the pressure switch DG are used to relieve the pressure. The pressure switch must be adjusted in such a way so that enough pressure is relieved and no air can get into the pipework. p a control opens the main gas solenoid valves and with the enable signal and enables the downstream burner control units. DG V p with two gas solenoid valves Tightness control checks gas solenoid valves and for tightness. The external pressure switch monitors the pressure between the two valves. 10 1 3 4 5 6 7 8 9 10 11 1 13 control forwards the enable signal to the automatic burner control unit. The pilot valve output of the automatic burner control unit opens the gas solenoid valves and simultaneously. The burner starts. DG and : quick or slow opening valves with start rate. DG pe V p 1 3 4 5 6 7 8 9 10 11 1 13 in a multiple burner system with one auxiliary valve for discharge Tightness control checks the central shut-off valve, the auxiliary valve and several burner valves for tightness. The external pressure switch monitors the pressure between the gas solenoid valves, and the burner valves. Once the tightness test has been carried out successfully, opens gas solenoid valve. The tightness control forwards the enable signal simultaneously to the automatic burner control units for the burner valves. The burner valves open and the burners start. Thanks to the relief line and auxiliary valve, the test volume is discharged into the open air via the roof or into the combustion chamber. : quick opening valve. : quick opening, nominal size is dependent on test volume and inlet pressure, but is at least DN 15. DG

TC Edition 1.10 7 DG pe V p 1 3 4 5 6 7 8 9 10 11 1 13 in a multiple burner system with two auxiliary valves for supply and discharge Tightness control checks the central shut-off valve, auxiliary valves and and several burner valves for tightness. The test volume is supplied via the auxiliary valve. The external pressure switch monitors the pressure between the gas solenoid valves and the burner valves. Once the tightness test has been carried out successfully, opens the central shut-off valve. The tightness control forwards the enable signal simultaneously to the automatic burner control units for the burner valves. The burner valves open and the burners start. Thanks to the relief line and auxiliary valve, the test volume is discharged into the open air via the roof or into the combustion chamber. : any. and : quick opening, nominal size is dependent on test volume and inlet pressure, but is at least DN 15. DG DG pe V4 DG 1 3 4 5 6 7 8 9 10 11 1 13 in a multiple burner system with 3 valves installed in series When using slow opening main gas solenoid valves ( and ), auxiliary valves ( and V4) must be used for the supply and discharge of the test volume V p. Tightness control checks the central shut-off valve, the gas solenoid valve and the auxiliary valves and V4 for tightness. Valve can only be checked for tightness when the pressure downstream of approximately corresponds to the atmospheric pressure. The gas solenoid valve and the pressure switch DG are used to relieve the pressure. The pressure switch must be adjusted in such a way so that enough pressure is relieved and no air can get into the pipework. control opens the main gas solenoid valves and with the enable signal and enables the downstream burner control units. and V4: quick opening, nominal size is dependent on test volume and inlet pressure, but is at least DN 15. DG DG V4

8 TC Edition 1.10 Technical data Mains voltage: 110/10 V AC, -15/+10%, 50/60 Hz, 0/40 V AC, -15/+10%, 50/60 Hz, 4 V DC, ±0%. Ambient temperature: -15 to +60 C (+5 to +140 F), no condensation permitted. Housing made of impact-resistant plastic. TC 1 3 For natural gas, town gas and LPG (gaseous), also for biologically produced methane. Inlet pressure : 10 to 500 mbar (3.9 to 195 "WC). Test period t P : 10 to 60 s, adjustable. Set at the factory to 10 s. Enclosure: IP 54. Standard coupler plug to DIN 43650/ISO 4400. Type code Gas type and inlet pressure : dependent on external pressure switch. Test period t P : 10-1: 10 to 60 s, adjustable. Set at the factory to 10 s. 10-10: 100 to 600 s, adjustable. Set at the factory to 100 s. Enclosure: IP 40. Maintenance cycles The tightness control requires little servicing. We recommend a function check once a year. Code Description TC Tightness control 1 For attachment to valvario controls and CG For quick opening individual valves 3 For quick or slow opening or manually resettable individual valves 4 For control cabinet installation 1 Testing before or after burner run 0 External pressure switch required 6 6 mm (0.4") connection 8 8 mm, ¼" (0.31") connection T T-product -1 Test period 10 to 60 s -10 Test period 100 to 600 s R Rp internal thread N NPT internal thread V Mounted to valvario controls using adapter plate W Mounted to combination control CG 05 max. 500 mbar (7.5 psig) K N T Mains voltage: 4 V DC 110/10 V AC, 50/60 Hz 0/40 V AC, 50/60 Hz Detailed information on this product www.docuthek.com Contact www.kromschroeder.com Sales Elster GmbH Postfach 809 49018 Osnabrück Strotheweg 1 49504 Lotte (Büren) Germany T +49 541 114-0 F +49 541 114-370 info@kromschroeder.com www.kromschroeder.com www.elster.com We reserve the right to make technical modifications in the interests of progress. Copyright 007 011 Elster Group All rights reserved. 0350631