ORION PLUS three-phase kVA

Similar documents
ahead of time Voltage Stabilisers

ahead of time Voltage Stabilisers

PRODUCT CATALOGUE 2016

ahead of time Voltage Stabilisers

ahead of time Voltage Stabilisers

CT-GB-39/05 VOLTAGE STABILISERS 1

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

TECHNICAL DATA SHEET KVA UPS Systemss

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

MASTERYS IP+ 10 to 80 kva

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

UPS Multi Sentry 10-20kVA

Green Power 2.0 MASTERYS GP

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

500 / 630 / 720 / 760 / 800 / 850 / 900

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Three Phase UPS Systems Range: 10 to 500kVA

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

POWER kva

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

MGE TM Galaxy TM 7000 GFC

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

DC POWER SUPPLY SYSTEMS

Technical Data Sheets

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Technical Specification SENTINEL PRO

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

ITW GSE 2400 COMPACT GPU kva solid-state GPU

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Automatic COSYS PFC. Automatic power factor correction system NEW

PowerValue 11/31 T kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Conversion System The Best Technology for your photovoltaic and storage system

D Series: UPS UPTO - 300KVA - Three / Three Phase

POWER kva

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Standard specification Galaxy PWi, three-phase, 10 to 200 kva

Technical Data Sheets

MGE TM Galaxy TM 7000

LV Capacitor Bank APC

.3 Section Waste Management and Disposal.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Transfer switch OHPC open or delayed transition

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Step 1: Collection of required data

Master DIALOG INDUSTRY RANGE

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

HOBART POWERMASTER & 90 kva solid-state GPU. It s all about connections

Master Plus kva

60 to 160 kva.

HOBART POWERMASTER & 90 kva solid-state GPU. It s all about connections

SAVER DSP SERIES. 3-10kVA USER MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ABB central inverters ULTRA-750/1100/ kW to 1560kW

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Industrial PFC UPS System

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Technical Data Sheets

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

LV Capacitor Bank APC

Technical Data Sheets

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Uninterruptible Power Systems

Medium Voltage Metal-Enclosed Switches

EP series WPS100S-AU rpm,3-phase/5-wiring

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

2.7. IT system floor-standing distribution cabinet Series -IPS-F

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

E-15 Uninterruptible Power Systems (UPS)

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Master Plus kva

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Master MPS kva kva 3:1 3:3 VFI TYPE

Transcription:

ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through different internal connections. The Orion Plus voltage stabilizers regulate the output voltage independently on each phase. Similarly to the Orion stabilizers, they can supply any single-phase, biphase and three-phase load even in case of and up to 100% unbalanced load current and asymmetrical mains distribution. In this configuration, the presence of the neutral wire is required. The stabilizer can also operate without neutral wire by adding a device able to generate it (D/zn or D /yn isolating transformer or neutral point reactor). The stabilizers are cooled via natural air ventilation, assisted by extracting fans when the cabinet internal temperature exceeds 35 C). The instrumentation consists of two multi-task digital line analyzers which are able to provide with information regarding the status of the lines upstream and downstream the voltage stabilizer (phase and linked voltages, current, power factor, active power, apparent power, reactive power, etc.) The operating status of the stabilizer can be monitored by means of the LEDs on the front panel displaying all the information regarding each phase operating mode ('power on'; reaching of voltage regulation limits; increase/decrease of voltage regulation) and the possible alarms (minimum and maximum voltage, maximum current: over temperature; ventilation failure). The alarm indicators are accompanied by an acoustic alarm. Up to 250kVA ±15%, the regulation circuit is protected against overload and short circuit on the voltage regulator by an automatic circuit breaker. From 300kVA ±15%, an electronic voltage regulator protection system activates in case of overload on the voltage regulator. In such condition, the load supply is not interrupted, but the stabilizer output voltage is automatically set to the lower between the mains voltage and the pre-set output voltage. The service continuity is guaranteed, although the voltage is not stabilized. When the overload condition ceases to exist, the stabilizer switches automatically back to regular functioning. The auxiliary circuits are protected by fuses. The control logic, performed on the true RMS value, is based on DSP microprocessors. The unit parameters and the output voltage reference can be set by using a personal computer, thus allowing for dealing directly in the field with any problems related to voltage stability. All Orion Plus stabilisers are provided with Class II SPD surge arrestors.

Voltage stabilisation PC selectable output voltage* Independent phase control from 210 to 255V (L-N) from 360 to 440V (L-L) Frequency 50/60Hz ±5% Admitted load variation Up to 100% Admitted load imbalance 100% Cooling Ambient temperature Storage temperature Max relative humidity 95% Admitted overload Harmonic distortion Natural air ventilation. Up to 35 C aided with fans -25/+45 C -25/+60 C 200% 2 min. None introduced Colour RAL 7035 Protection degree Instrumentation Installation Overvoltage protection IP21 & output digital multimetre Indoor Class II output surge arrestor Optimal voltage return through supercapacitors in case of blackout * The output voltage can be adjusted by choosing one of the indicated values. Such choice sets the new nominal value as a reference for all the stabilizer parameters. Accessories - available on request Interrupting devices Load protection against over/undervoltage Manual by-pass line Total protection kit isolating transformer Integrated automatic power factor correction system SPD surge arrestor EMI/RFI filters Neutral point reactor IP54 protection degree for indoor and outdoor installation All the stabilizers are designed and built in compliance with the Low Voltage and Electromagnetic Compatibility European Directives with regard to the CE marking requirements. The products are built with suitable quality components and that the manufacturing process is constantly verified in accordance with the Quality Control Plans which the manufacturer applies in compliance with the ISO 9001:2008 Standards. The commitment towards environmental issues and safety at work maters is guaranteed by the certification of the Management System according to the ISO14001:2004 and OHSAS18001:2007 Standards. In order to obtain better performance, the products described in the present document can be altered by the manufacturer at any date and without prior notice. Technical data and descriptions do hold therefore any contractual value.

voltage variation ±20% or ±15%, Rated power 60 to 1250 kva 60 60-20 ± 20 % 109 86 12 80 80-15 ± 15 % 136 116 16 80 80-20 ± 20 % 145 116 12 105 105-15 ± 15 % 179 152 16 105 105-20 ± 20 % 190 152 12 135 135-15 ± 15 % 229 195 16 120 120-20 ± 20 % 216 173 14 150 150-15 ± 15 % 255 217 18 135 135-20 ± 20 % 244 195 14 175 175-15 ± 15 % 298 253 18 150 150-20 ± 20 % 271 217 14 200 200-15 ± 15 % 340 289 18 175 175-20 ± 20 % 316 253 14 250 250-15 ± 15 % 425 361 18 250 250-20 ± 20 % 446 361 15 320 320-15 ± 15 % 544 462 20 300 300-20 ± 20 % 543 434 15 400 400-15 ± 15 % 680 578 20 400 400-20 ± 20 % 723 578 15 500 500-15 ± 15 % 851 723 20 500 500-20 ± 20 % 904 723 15 630 630-15 ± 15 % 1071 910 20 630 630-20 ± 20 % 1138 910 18 800 800-15 ± 15 % 1360 1156 24 800 800-20 ± 20 % 1445 1156 18 1000 1000-15 ± 15 % 1700 1445 24 1000 1000-20 ± 20 % 1806 1445 18 1250 1250-15 ± 15 % 2125 1806 24 600x800x1800 430 600x800x1800 490 600x800x1800 580 1200x800x1800 710 1200x800x1800 760 1200x800x1800 950 1200x800x1800 1100 1200x800x2000 1400 1200x1000x2000 1600 1800x1000x2000 2000 1800x1000x2000 2200 2400x1000x2000 2400

voltage variation ±30% or ±25%, Rated power 30 to 800 kva 30 30-30 ± 30 % 61 43 8 45 45-25 ± 25 % 86 65 10 45 45-30 ± 30 % 93 65 8 60 60-25 ± 25 % 116 87 10 60 60-30 ± 30 % 124 87 8 80 80-25 ± 25 % 156 116 10 80 80-30 ± 30 % 166 116 9 90 90-25 ± 25 % 173 130 11 90 90-30 ± 30 % 185 130 9 105 105-25 ± 25 % 203 152 11 105 105-30 ± 30 % 217 152 9 120 120-25 ± 25 % 231 173 11 120 120-30 ± 30 % 247 173 9 135 135-25 ± 25 % 260 195 11 150 150-30 ± 30 % 310 217 10 200 200-25 ± 25 % 385 289 12 200 200-30 ± 30 % 413 289 10 250 250-25 ± 25 % 481 361 12 250 250-30 ± 30 % 515 361 10 300 300-25 ± 25 % 579 434 12 300 300-30 ± 30 % 620 434 10 400 400-25 ± 25 % 771 578 12 400 400-30 ± 30 % 826 578 12 500 500-25 ± 25 % 963 723 15 500 500-30 ± 30 % 1032 723 12 630 630-25 ± 25 % 1214 910 15 630 630-30 ± 30 % 1300 910 12 800 800-25 ± 25 % 1541 1156 15 600x800x1800 430 600x800x1800 490 600x800x1800 580 1200x800x1800 710 1200x800x1800 760 1200x800x1800 950 1200x800x1800 1200 1200x800x1800 1300 1200x800x2000 1400 1200x1000x2000 1600 1800x1000x2000 2000 1800x1000x2000 2200 2400x1000x2000 2400

voltage variation +15% to -35%,Rated power 45 to 800 kva 45 45-15/35 +15% -35% 100 65 10 600x800x1800 470 60 60-15/35 +15% -35% 134 87 10 600x800x1800 550 80 80-15/35 +15% -35% 178 116 10 600x800x1800 600 90 90-15/35 +15% -35% 200 130 11 105 105-15/35 +15% -35% 234 152 11 1200x800x1800 950 120 120-15/35 +15% -35% 266 173 11 1200x800x1800 1050 135 135-15/35 +15% -35% 300 195 11 1200x800x1800 1200 200 200-15/35 +15% -35% 445 289 12 1200x800x1800 1500 250 250-15/35 +15% -35% 511 332 12 1800x800x2000 1650 300 300-15/35 +15% -35% 668 434 12 1800x800x2000 1750 400 400-15/35 +15% -35% 889 578 12 1800x1000x2000 2100 500 500-15/35 +15% -35% 1111 723 15 2400x1000x2000 2900 630 630-15/35 +15% -35% 1400 910 15 2400x1000x2000 3050 800 800-15/36 +15% -35% 1778 1156 15 3000x1000x2000 3800 Rated voltage variation +15% to -45%, Rated power 30 to 630 kva 30 30-15/45 +15% -45% 78 43 8 600x800x1800 470 45 45-15/45 +15% -45% 118 65 8 600x800x1800 550 60 60-15/45 +15% -45% 158 87 8 600x800x1800 600 80 80-15/45 +15% -45% 211 116 9 90 90-15/45 +15% -45% 236 130 9 1200x800x1800 950 105 105-15/45 +15% -45% 276 152 9 1200x800x1800 1050 120 120-15/45 +15% -45% 315 173 9 1200x800x1800 1250 150 150-15/45 +15% -45% 395 217 10 1200x800x1800 1450 200 200-15/45 +15% -45% 525 289 10 1800x800x2000 1650 250 250-15/45 +15% -45% 656 361 10 1800x800x2000 1800 300 300-15/45 +15% -45% 789 434 10 1800x1000x2000 2200 400 400-15/45 +15% -45% 1051 578 12 2400x1000x2000 3000 500 500-15/45 +15% -45% 1315 723 12 2400x1000x2000 3200 630 630-15/45 +15% -45% 1655 910 12 3000x1000x2000 4000