Metso Conductivity for sensor series 9400 and 9500

Similar documents
Valmet Dual Conductivity Measurement Series 3200

Inductive conductivity meter

Inductive conductivity meter

Valmet Concentration Measurement Series 3300

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Digital ph transmitter

Conductivity Measuring Sensor InduMax H CLS 52

Valmet Conductivity Measurement Series 3100

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

Digital ph transmitter

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

JUMO ecotrans Lf 01/02

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

VEROTEC Electronics Packaging

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Sensors and Systems for Combustion Engineering

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Conductivity Measuring Cells ConduMax W CLS 19

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Signet Conductivity/Resistivity Electrodes

Conductivity Measurement CLM 280

Pressure transducer DMU 01K Compact version

RVP-R- VAV controller. In explosion-proof version

Overview of types. Technical data. Safety notes

better measurement Simply a question of

Electromagnetic Flow Monitor magphant

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

OD OD DIGITAL DISSOLVED OXYGEN CONTROLLERS

Differential pressure sensor

Overview. Application. Function. Design. Home

SITRANS P measuring instruments for pressure

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Continuous level measuring system NB 3000 Selection list. Overview

Actuator type ABNM with Theft Protection, 0-10 V Proportional

Art. no TT/S2 temperature immersion sensor with 2 m siliconee cable, 180 C

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

See «Overview of types»

PRODUCTS: POWER SUPPLY

Pressure transmitters for industrial applications Type MBS 4510

Resistance thermometer with digital indicator Model TR75, battery operation

Pressure Transmitters for Sanitary Applications Model SA-11

GA 24 Heavy-duty variable area flowmeter

SM 1231 ANALOGINPUT MODULE

Metal tube variable area flowmeter for gases, liquids and steam

Turbidity and Suspended Solids Transmitter

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

better measurement Simply a question of

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Compact System NRGS 11-2 NRGS Original Installation Instructions English

CAUTION CM-SE CM-S21 CM-S41

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

Conductivity Sensors ConduMax W CLS 19

Differential Pressure Switch QBM81-

Pluggable interface relays RT, PT and MT range

V-SENSOR LOW AIR VELOCITY SENSOR

Magnetic-Inductive Flow Meter FMI

introduction FE Series Automated Butterfly Valves Product Data Sheet < STANDARDS >

Insertion thermometer With connection lead Model TF45

Magnetic and Hydraulic-Magnetic Circuit Breaker

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

DPX - DPAX butterfly valve technical description

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Orbipore CPS91 and CPS91D

Power consumption In operation At rest For wire sizing

TKD Series 3-Way Automated Ball Valves Product Data Sheet. Body Material: PVC Size Range: 1/2" through 2"

Continuous level measuring system NB 3000 Selection list

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

OD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL

Electronic Monitoring Systems

Power consumption In operation At rest For wire sizing

JUMO MIDAS Pressure transmitter

FasTrak High Capacity Smart Positioner

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

VT-SENSOR AIR VELOCITY AND TEMP

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

Measuring Cells for free chlorine, chlorine dioxide, ozone

OD DISSOLVED OXYGEN METER

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

MAIN FUNCTION FEATURES. . D = v t /2

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Transcription:

Metso Conductivity Modules 2800 for sensor series 9400 and 9500 Metso Conductivity Modules 2800 Plug-in modules easy service Exchangeable scales with concentration reading Remotely controlled range switch Bar graph indicator Individual temperature compensation Accurate ma output Tight enclosures of stainless steel or plastic

4-electrode conductivity measurement The conductivity of liquor is determined by the concentration of free ions. The measurement of a specific conductivity can thus be used for concentration measurement and for testing the purity of water. Utilizing the 4-electrode principle for conductivity measuring instruments gives easy installation, minimum maintenance, and accurate on-line readings with short response time. Fig. 1 The 4-electrode principle The 4-electrode principle With the 4-electrode conductivity principle, the conductivity of the liquor is calculated from the ratio of the current through the liquor and the voltage across a separatepair of electrodes (VE). The calculated conductivity is unaffected by scaling and polarisation at the electrodes, in other words: It is possible to make accurate conductivity measurements without making heavy demands on the electrode design. 4-electrode conductivity sensors can thus be constructed with a low capacitance between the electrodes to facilitate low conductivity measurements and with small dimensions to minimize mounting requirements. Temperature compensation In an electrolyte, all ions present will contribute to the conductivity. Different ions will contribute with different amounts, and the amounts will vary with the temperature. When the conductivity is used for the calculation of a chemical concentration, it is necessary to calculate what the conductivity would be at a fixed temperature (the conductivity is temperature compensated). This conductivity is calculated from the measured conductivity and the temperature. As different ions have different temperature dependences, the temperature compensation must be selected to fit the actual application. The temperature is measured with a Pt 1000 resistor located in the sensor. Cell constant All sensors for module type 2822 are electrically adjusted to cell constant 1.00. Conductivity Fig. 2 Conductivity versus concentration for acid, lye and salt solutions in water at 25 C. 1S/m = 1000 ms/m = 10 ms/cm. Fig. 3 Conductivity curves for beverage products at 25 C, diluted with water having a conductivity of 100 ms/m (= 1 ms/ cm).

2822 Conductivity Module (12 TE) Conductivity Module General information 4-electrode conductivity module for mounting in a 19 rack system with eurocard module, height 3HE (132.53 mm), and connectors for use with series 9400 and 9500 sensors. The module has a 20-segment bar graph (50 mm), a current output, and a remotely controlled application switch. The conductivity range and the temperature compensation are set individually for each application. Conductivity range switch Switch pos. 0 1 2 3 4 5 6 7 Conductivity 0-1 2 5 10 20 50 100 200 ms/m 0-10 20 50 100 200 500 1000 2000 μs/cm Switch pos. 8 9 A B C D E F Conductivity 0-0.1 0.2 0.5 1 2 5 10 20 S/m 0-1 2 5 10 20 50 100 200 ms/cm 1 ms/m = 10 μs/cm. 1 S/m = 1000 ms/m = 10 ms/cm. Temperature compensation switch 0 0 %/ C Without temperature compensation. 1 1.3 %/ C Acid 1 (HNO 3 1 %) 0-125 C 2 1.7 %/ C Lye (NaOH 1 %) 0-125 C 3 2.1 %/ C STD salt (NaCl) 0-125 C 4 0.7 %/ C Acid 4 (H 3 PO 4 1 %) 0-125 C 5 1.0 %/ C Acid 5 (H2 S O 4 1 %) 0-125 C 6 Sat salt (NaCl 26 %) 0-100 C Ref. temperature: Pos 1 to 5 = 25 C, pos 6 = 10 C Mode Linear scale 0-X or compressed scale 0-X- (X being the range set by the multi-range switch. X equals a mid-scale output when using compressed scale). Accuracy 0.5 % of reading +0.2 % of range. 0.2 μs/cm per metre of sensor cable (max. 35 m sensor cable). Temperature Temperature effect: 0.5 C (0 100 C). 350 ppm/ C (σ) of actual measured value Indicator 20 segment bar graph, scale length 50 mm. Application switching Optocoupler input: 0 V (0 ma): Range A is active 6 26 V DC: Range B is active Max. voltage versus ground: +/ 26 V. Input current: 0.45 ma at 6 V, 2.6 ma at 26 V. Supply voltage 24 V DC ± 20% or 24 V AC ± 20 %. Power consumption approximately 1.8 W. The power input is galvanically isolated from the electronic circuit. Maximum voltage versus ground: 48 V. Fuse: 160 ma slow-blow (5 x 20 mm). Power supply effect: <0.1 %. Output Isolated output 0 20/4 20 ma (max. output voltage 15 V at 20 ma, 18 V at 0 ma). Maximum voltage versus ground: +/ 26 V.

Temperature limits For specified accuracy: 0 to +55 C For operation: 10 to +65 C For storage: 40 C to +70 C Exchangeable scales (optional) The conductivity module can be supplied with one or two exchangeable scales to facilitate the reading of the bar graph. Each exchangeable scale specifies the setting of range switch, temperature compensation switch, and the lin / 0-x- switch. Sensors 4-electrode conductivity sensors with Pt 1000 temperature element, one 15-pole D-connector. Series 9400 Sanitary sensors, max. temperature 130 150 C, max.pressure 20 bar. Series 9500 Industrial sensors like series 9200, but with 15-pole Dconnector, max. temperature 120-210 C, max. pressure 20 50 bar. Sensor cable Screened 16-wires, 0.25 mm 2. Kemotron type 70633. Cable errors approx. 0.02 ms/m (0.2 μs/cm) per cable metre, for cable length up to 35 metres. CE certification EN 50081-1, EN 50081-2, EN 50082-1, and EN 50082-2. In order to comply with the EMC directive, the following must be observed: The module must be used with one the the following terminal backplanes: Type 419, 412, 414, 415, 416, 417, 418, 443, 445 and it must be connected to a series 9400 or 9500 sensor. Sensor connection

Exchangeable scales

Termination equipment and enclosures 490/2 card frame Type 490 card frame (84TE) based on Eurocard system (DIN 41 494), 3HE (133.35 mm), 84TE (426.72 mm). The card frame is delivered ready mounted. Rails and internal connections are included in the frame, but terminal board 419, plug-in modules 2822, power supply, and blinds have to be ordered separately. 419 terminal board 495 Power supply Blinds Power supply for incorporation in enclosures to supply plug-in modules with 24 V AC, through the included transformer from 230 V or 115 V AC, 12 TE. Type 497-12

Stainless steel enclosures with swing frame Mounting plates Type 412 mounting plate is used for right side mounting of the 2822 module in a plastic junction box or other enclosures. Sensor adaptor - use a hole of min Ø 28.3 mm for a PG21 connection. Type 408 is a mirrored duplicate of type 412, for left side mounting. 428 Bottom chassis Conductivity Module Conductivity Module Cabinet of stainless steel with pane door. The cabinet is delivered ready-mounted with 19 subracks on the swing frame, which makes it easy to access the terminal strips on the backside of the subracks when opening the swingframe. Rails and internal connections are included in the cabinet, but mounting plates, plug-in modules, power supply, and blinds have to be ordered separately.

Plastic enclosures 1-channel enclosures Type 414 for wall mounting Type 415 for panel mounting and Type 416 for pipe mounting Technical data Material: ABS with neoprene packings. Protection: IP65 splash-proof, DIN 40 050. Temperature: 40 to +80 C. Fire class: 94 lt (combustible). Power supply: 24 V AC/DC to be screened. Power consumption: 2 VA. Sensor connection: D-connector 15-pole. Sensor cable: PVC type 70633 ~ 16 x 0.25 mm. Type 416 a: For pipe diameter 25 38 mm b: For pipe diameter 35 52 mm c: For pipe diameter 50 73 mm d: For pipe diameter 72 94 mm e: For pipe diameter 82 114 mm Power supply Type 494 external power supply 230/115 V to 24 V AC, 10 VA. Type 8981 Cable kit D-connector to D-socket. Type 8982 Cable kit D-connector to strip. Multi-channel enclosures Type 443 for wall mounting (3-channels, 230/115 V AC) Type 445 for wall mounting (4-channels, 24V AC/DC) Technical data Material: ABS with neoprene packings. Protection: IP65 splash-proof, DIN 40 050. Temperature: 40 to +80 C. Fire class: 94 lt (combustible). Power supply: Type 443-230/115 V AC. Type 445-24 V AC/DC to be screened. Power consumption: Sensor connection: Sensor cable: Type 443-3 x 2 VA. Type 445-4 x 2 VA. D-connector 15-pole. PVC 16 x 0.25 mm 2, screened max. temperature 70 C, type 70633. Metso Automation Inc. 12/2010 B183 011.0-EN For more information, contact your local automation expert at Metso. www.metso.com/conductivity The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice.