Micro Contactor MA Series

Similar documents
Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

General Catalogue. Quality made in D946E173

Contactors RAST 5 D778E131

Index. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Contactors Motor-Starters D677E121

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

Capacitor Switching Contactors Type K3...-A, K3...-K

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

CI-TI Contactors and motor starters Types CI 61 - CI 98

AF40... AF96 3-pole contactors Technical data

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

ASL09..S 3-pole Contactors - Spring Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Modular Contactors and Switches D681E121

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Modular contactor for installation into distribution boards

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Industrial Contactors CTX 3 3P 185A - 800A

RUC industrial relays of small dimensions

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

3RT14 Contactors with 3 Main Contacts

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

CI-TI Contactors and Motor Starters Type CI 6-50

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Description. Positive safety relays

General Informations 2 Technical data 3 Basic designs 4-8

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

4 - Miniature controls

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Contactor Types CI 61-98

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TAE pole Contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

55 Series - Miniature General Purpose Relays 5-10 A

Essential equipment for all your requirements

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

AE 9... AE 40 Contactors NE... Contactor Relays

5 mm contact pin pitch PCB or 95 series sockets

Ktec Contactors and thermal overloads

Technical data for manual motor starters Type MS325

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

40 Series - Miniature PCB relays A. Features

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Page 2-4 Page 2-8. Page Page 2-13

Application Mini Contactors for Motors and Resistive Loads

Mini Contactors CI 4-

DC-Switch Disconnectors for Photovoltaic acc. to IEC

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

General_technical_data Series

2 pole 10 A PCB mount A1 A

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Meta Solution. Contactors and Overload relays

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Switches Unlimited Phone: * Fax:

Mini contactors B6, BC6 with 3 pole

Short form catalogue. Motor protection & control

Auxiliary contact blocks - with spring terminals Accessories

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

3 - Protection components Motor circuit-breakers

General Purpose Relays Accessories. Accessories Industrial Power Relay RT

Manual Motor Starters. Meta-MEC

AF series contactors (9 2650)

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Star Series Motor protection & control

Technical Information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Special Purpose Fuses

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Meta Solution. Contactors and Overload relays

Pluggable interface relays RT, PT and MT range

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Bulletin 825 SMM Smart Motor Manager

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Transcription:

Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC 5A AC3 @ 400VAC (2.2) - 12A AC1 @ 400VAC AC coil voltages - TS15 DIN rail mounting PCB mounting DC coil pending Micro Contactor Relays Page 2 Micro Contactors Page 3 Micro Contactors With Solder Pins Coil Voltages Page 4 Micro Reversing Contactor Page 5 Technical Data Page 6 Dimensions Page 10

Micro Contactor Relays 4-Pole Ratings Therm. Contacts * 2 Type Coil Voltage * 1 Distinc. Number Additional Contact 24 230 24V 50/60Hz 220-240V 50/60Hz AC15 Rated- Current 230V A 400V A I th A NO NC acc. to EN50011 Blocks Pack â Type pcs. Weight kg/pc. 4-Pole, With Screw Terminals 3 1.5 5 4-40E - MA04-S-40... 10 0.07 3 1.5 5 3 1 31E - MA04-S-31... 10 0.07 3 1.5 5 2 2 22E - MA04-S-22... 10 0.07 MA04-S-40 MA04-S-31 MA04-S-22 *1 Other coil voltages - see page 4 *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. P2

Micro Contactors Power Ratings Rated Current Aux. Contacts *2 Built-in Additional Type Coil Voltage * 1 AC2, AC3 AC1 24 230 24V 50/60Hz 220-240V 50/60Hz 380V 400V 415V 660V 690V 440V A NO NC Type â Pack pcs. Weight kg/pc. 3-Pole, With Screw Terminals 2.2-12 1 - - MA05-S-10... 10 0.07 2.2-12 - 1 - MA05-S-01... 10 0.07 4-Pole, With Screw Terminals 2.2-12 - - - MA05-S-0040... 10 0.07 MA05-S-10 MA05-S-01 MA05-S-0040 Snap-On Adaptor For Type Specification Type Pack pcs. Weight kg/pc. MA for snap mounting of MA-P1039 10 0.01 Snap on Adaptor for MA accessories on 35mm DIN-Rail acc. DIN EN 50022 *1 Other coil voltages - see page 4 *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. P3

Micro Contactors Power Ratings Rated Current Aux. Contacts *2 Built-in Additional Type Coil Voltage * 1 AC2, AC3 AC1 24 230 24V 50/60Hz 220-240V 50/60Hz 380V 400V 415V 660V 690V 440V A NO NC Type â Pack pcs. Weight kg/pc. 3-Pole, With Solder Pins Ø1.15 For Printed Circuit Applications 2.2-9 1 - - MA05-P-10... 10 0.07 2.2-9 - 1 - MA05-P-01... 10 0.07 4-Pole, With Solder Pins Ø1.15 for Printed Circuit Applications 2.2-9 - - - MA05-P-0040... 10 0.07 MA05-P-10 MA05-P-01 MA05-P-0040 Coil Voltages for AC operated contactors Suffix to Voltage Marking Rated Control Voltage U s contactor type at the coil range e.g. for for for 50Hz for 60Hz MA05-S- 50Hz 60Hz min. max. min. max. 1024AC V V V V V V 12 12 12 11 12 12 12 24 24 24 22 24 24 24 42 42 42 38.5 42 42 42 48 48 48 48 50 48 52 90 100 100 90 100 100 105 95 95-100 105-110 95 100 105 110 100 100 110-115 100 105 110 115 105 105-110 115-120 105 110 115 120 110 110-115 120-125 110 115 120 125 180 200 200 185 200 200 210 Suffix to Voltage Marking Rated Control Voltage U s contactor type at the coil range e.g. for for for 50Hz for 60Hz MA05-S- 50Hz 60Hz min. max. min. max. 10230AC V V V V V V 200 200 200-220 195 205 200 220 210 205-215 220-230 205 215 220 230 220 210-220 220-240 210 220 220 240 230 220-230 230-250 220 230 230 250 240 230-240 230 240 250 260 Standard voltages in bold type letters Operating range of magnet-coils: 0.85 x U S (min value of rated control voltage) up to 1.1 x U S (max value of rated control voltage) Coil not exchangeable *1 Other coil voltages - see above *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. P4

Micro Reversing Contactors, Mechanical Interlock Power Ratings Rated Current Aux. Contacts *2 Built-in Additional on the left hand side contactor on right hand side contactor Type 24 230 Coil Voltage * 1 24V 50/60Hz 220-240V 50/60Hz AC2, AC3 AC1 380V 400V 415V 660V 690V 440V A NO NC K1 Type K2 Type â Pack pcs. Weight kg/pc. 3-Pole, With Screw Terminals 2.2-12 - 1 - - MA05-R-S-01... 1 0.14 2.2-12 1 - - - MA05-R-S-10... 1 0.14 4-Pole, With Screw Terminals 2.2-12 - - - - MA05-R-S-0040... 1 0.14 3-Pole, With Solder Pins Ø1.15 For Printed Circuit Applications 2.2 - xxx *3-1 - - MA05-R-P-01... 1 0.14 2.2 - xxx *3 1 - - - MA05-R-P-10... 1 0.14 MA05-R-S-01 MA05-R-S-10 MA05-R-S-0040 *1 Other coil voltages - see page 4 *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. *3 Data available upon request P5

Data according to IEC 60947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type MA05-S.. Rated insulation voltage U i V AC 480 *1 Making capacity I eff at U e =440V AC A 65 Breaking capacity I eff cosφ = 0.65 400V AC A 50 Utilization category AC1 Switching of resistive load (=I th ) at 40 C, open A 12 Rated operational power of three-phase resistive loads 230V 4.7 50-60Hz, cosj=1 240V 4.8 400V 8.3 415V 8.6 480V 9.5 (=I th ) at 60 C, enclosed A 8 Rated operational power of three-phase resistive loads 230V 3.1 50-60Hz, cosj=1 240V 3.3 400V 5.5 415V 5.7 480V 6.5 Minimum cross-section of conductor at load with I e (=I th ) mm 2 1.5 Utilization category AC2 and AC3 Switching of three-phase motors 220V A 6.2 open and enclosed 230V A 6.2 240V A 5.6 380-400V A 5 415-440V A 5 480V A 5 Rated operational power of three-phase motors 220-240V 1.5 50-60Hz 380-440V 2.2 480V 2.2 Utilization category AC4 Switching of squirrel cage motors, inching 220V A 4.9 open and enclosed 230V A 4.9 240V A 4.1 380-400V A 3.5 415-440V A 3.5 480V A 3.5 Rated operational power of three-phase motors 220-240V 1.1 50-60Hz 380-440V 1.5 480V 1.5 *1 Suitable at 690V for: earthed-neutral systems, overvoltage category I to III, polution degree 3 (standard-industry): Uimp = 4kV. Data for other conditions on request P6

Data according to IEC 60947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type MA05-S.. Utilization category DC1 Switching of resistive load 1 pole 24V A 12 Time constant L/R 1ms 60V A 12 110V A - 220V A - 3 poles in series 24V A 12 60V A 12 110V A 12 220V A - Utilization category DC3 and DC5 Switching of shunt motors and series motors 1 pole 24V A 12 60V A - Time constant L/R 15ms 110V A - 220V A - 3 poles in series 24V A 12 60V A 12 110V A 12 220V A - Maximum ambient temperature Operation open C -40 to +60 (+90) *1 enclosed C -40 to +40 with thermal overload relay open C -25 to +60 enclosed C -25 to +40 Storage C -50 to +90 Short circuit protection for contactors without thermal overload relay Coordination-type 1 according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size Coordination-type 2 according to IEC 947-4-1 Light contact welding accepted max. fuse size gl (gg) A 20 gl (gg) A - Contact welding not accepted max. fuse size gl (gg) A - For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size Cable cross-sections for contactors main connector solid or stranded mm 2 0.5-1.5 flexible mm 2 0.5-1.5 flexible with multicore cable end mm 2 0.5-1.5 Cables per clamp 2 solid or stranded AWG 20-14 Frequency of operation z without load 1/h 10000 contactors without thermal overload relay AC3 I e 1/h 600 AC4 I e 1/h 120 DC3 I e 1/h 600 Mechanical life AC operated S x 10 6 3 DC operated S x 10 6 xxx *2 Short time current 10s-current A 50 Power loss per pole at I e /AC3 400V W 0.2 Resistance to shock according to IEC 68-2-27 Shick time 20ms sine-wave AC operated NO g 2.5 NC g 2.5 *1 With reduced control voltage range 0.9 up to 1.0 x U s and with reduced rated current I e /AC1 according to I e /AC3 *2 Data on request P7

Data according to IEC 60947-5-1, VDE 0660, EN 60947-5-1 Auxilliary Contacts Type MA04-S.. MA05-S.. Rated insulation voltage U i VAC 440 *1 Thermal rated current I th bis 440V Ambient temperature 40 C A 5 60 C A 3 Power loss per pole I th W 0.25 Utilization category AC15 220-240V A 3 380-415V A 1.5 440V A 1 Utilization category DC13 60V A 0.5 - - Maximum ambient temperature Operation open C -40 bis to +60 (+90) *2 enclosed C -40 bis to +40 Storage C -40 bis to +90 Short circuit protection short circuit current 1kA, contact welding not accepted max fuse size gl (gg) A 10 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size Power consumption of coils AC operated inrush VA 9 sealed VA 4 W 1.8 Operation range of coils in multiples of control voltage U s 0.85-1.1 Switching time at control voltage U s ±10% *3*4 AC operated make time ms 13-18 release time ms 5-10 arc duration ms 10-15 DC operated make time ms - release time ms - arc duration ms - Cable cross-section all connectors solid mm 2 05-1.5 flexible mm 2 0.5-1.5 flexible with multicore cable end mm 2 0.5-1.5 Clamps per pole 2 solid or stranded AWG 20-14 *1 Suitable at 690V for: earthed-neutral systems, overvoltage category I to III, polution degree 3 (standard-industry): Uimp = 4kV Data for other conditions on request *2 With reduced control voltage range 0.9 up to 1.0 x U s and with reduced thermal rated current I th to I e /AC15 *3 Summary switching time = release time + arc duration *4 Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units) *5 Data on request P8

For North America - Data according UL508 Main Contacts (culus) Type MA05-S.. MA05-R-S.. Rated operational current General Use A 12 5 Rated operational power of three phase motors 110-120V hp ½ - at 60Hz (3ph) 200-208V hp 1-220-240V hp 1-277V hp 1½ Rated operational power of AC motors 110-120V hp ½6 - at 60Hz (1ph) 200-208V hp ½ - 220-240V hp ¾ Fuse / Short circuit current A/kA 30/5 - MA04-S.. Rated voltage VAC 300 300 Auxilliary contacts (culus) heavy pilot duty AC B300 B300 Standard pilot duty DC R300 R300 Motor Rating P n =AC4 380/ 220/ 400V 230V Motor Rating P n =AC3 380/ 220/ 400V 230V Breaking Current I a (=I e =AC1) A MA-05 Millions of Operations P9

Dimensions with screw terminals Snap-On Adaptor MA-P1039 MA04-S.. MA05-S.. Reversing Contactors with screw terminals MA..-S.. with Snap-On Adaptor MA-P1039 MA05-R-S.. with solder connections MA04-P.. MA05-P.. Reversing Contactors with solder connections MA05-R-S.. Mounting positions of contactors MA Ref: MAContactors15v2 Errors and omissions excepted. Subject to change without notice.