Electrical operating instructions

Similar documents
Electrical operating instructions

Electrical operating instructions

Mechanical Operating Instructions

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Electrical Operating Instructions

Electrical operating instructions

Mechanical operating instructions

Electrical operating instructions

Electrical Operating Instructions

Electrical operating instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Installation instructions

Installation Instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Operating instructions

Operating Instructions for Roll-Up Door Operators / MDF

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Operating instructions

Unified requirements for systems with voltages above 1 kv up to 15 kv

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

Installation and Maintenancee Manual

Technical Manual Electrical Power Supply System T4002

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

Installation instructions

Operating instruction and technical description

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Car Battery Charger Instructions for Use

Installation instructions

Fan Coil Unit (FCU) Fan Motor Control

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

GLM SERIES CONTROL Users Manual Rev:

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

1 Phase electronic contactor (SC 1)

Instruction Manual. Q Series 2 Motor Control Modules - OEM

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

Porte 150 Users Manual Swing Gate Opener 24V DC

Installation Instructions

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

AF series contactors (9 2650)

MODEL SCA Installation and Operation Manual Important:

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Reproduction. Not for ADVANCE PRODUCT SERVICE INFORMATION INFORMATION BULLETIN NO: 36 DATE: 11/27/02 SUBJECT: POWERLINK SYSTEM

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

Element C8.3 Installation, Use and Inspection of Electrical Systems

EST Electrical Service Technician Answer Schedule

Installation Instructions Electric Heaters 5 20 kw

ELEKTROMATEN ST Sliding-door-drive

Effective discrimination of protective devices

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Bimetal Overload Relays 3UA and 3UC

Boardworks Ltd Mains Electricity

User Manual Rittal PMC UPS 6kVA

Sectional and Tilting Door Opener

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

AF series contactors (9 2650)

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Sectional and Tilting Door Opener Installation Instructions and User Guide

Assembly and Operating Instructions

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Compact System NRGS 11-2 NRGS Original Installation Instructions English

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

F3S-TGR-KHL1/-KHL3/-KHL3R

Installation Manual for DC Injection Brake Units

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

EMPAC Metal enclosed capacitor bank for wind applications

SDS Enclosed Star-Delta Starter User Guide

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Gas Insulated Metal-clad Switchgear, HMGS!

Components for EEx e Panels

Clamping and drive module

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Operating instructions Solenoid interlock EX-AZM About this document. Content

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Translation Operating instruction/ Assembling instruction Electromechanical Linear Actuator ELA.

SUBMERSIBLE PUMP HSE RANGE

LV Capacitor CLMD03 Power Module Instruction manual

Operating Instructions Pedestrian Turnstile Type MPT 33

EISHO TEK. Vacuum Circuit Breaker

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

ZB0050 / ZB0051 ZB0070 / ZB0071

EURO ECO / EURO deluxe DC 2 EURO ECO DC 2 EURO deluxe. Installation Manual DC 2. DC 2 - Control Unit conforms to DIN EN 12453

Reference Manual. UH28C High Voltage Tester

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

INDUS rail /

XENON POWER SUPPLY for 10 kw Britelight Lamphead

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Installation and Operating Instructions Electric Vibrators HV/VFL Series

12 amp RMS Battery Charger

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Transcription:

en Electrical operating instructions Reversing contactor universal 2 Contactor / 24V for three- and single- phase motor 51171134 - d 04.2009

OPERATING INSTRUCTIONS 52210115 consisting of: E : Electrical operating instructions M : Mechanical operating instructions (separately enclosed) List of Contents E Page SAFETY DIRECTIONS... E 2 ELECTRICAL CONNECTION...E 4 ASSEMBLY OF THE REVERSING CONTACTOR BOARD...E 5 REVERSING CONTACTOR BOARD UNIVERSAL... E 6 WIRE LINKS ON THE REVERSING CONTACTOR BOARD...E 7 PRIMARY ELECTRICAL CIRCUIT 3 x 220/230V AC, PE...E 8 3 x 380/400V AC, N, PE... E 9 3 x 380/400V AC, PE...E 10 3 x 460V AC, PE (special execution)...e 11 3 x 500V AC, N, PE (special execution)... E 12 1 x 220/230V AC, N, PE SYMMETRIC WINDING... E 13 1 x 220/230V AC, N, PE ASYMMETRIC WINDING... E 14 ELECTRICAL CONTROL... E 15 ADDITIONAL LIMIT SWITCHES...E 16 CONTROL DEVICES - TYPES OF CONNECTION... E 17 HELP WITH CORRECTING FAULTS...E 20 LIFETIME / DOORCYKLES... E 21

SAFETY DIRECTIONS 52220013 Basic Directions This control has been built in accordance with EN 12453 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements; and left the factory in perfect condition from the point of view of safety. To maintain this condition and to ensure safe operation, the user must observe all the directions and warnings contained in these operating instructions. In principle, only trained electrical craftsmen should work on electrical equipment. They must assess the work which has been assigned to them, identify potential danger sources and take suitable safety precautions. Reconstruction of or changes to ELEKTROMAT are only permissible with the approval of the manufacturer. Original replacement parts and accessories authorised by the manufacturer guarantee safety. Liability ceases to apply if other parts are used. The operational safety of an ELEKTROMATEN is only guaranteed if it is used in accordance with the regulations. The limiting values stated in the technical data should not be exceeded under any circumstances (see corresponding sections of the operating instructions). Safety Regulations During the installation, initial operation, maintenance and testing of the ELEKTROMATEN, it is necessary to observe the safety and accident-prevention regulations valid for the specific application. In particular, you should observe the following regulations (this list is not exhaustive): European normative - EN 12453 Safety in use of power operated doors - Requirements - EN 12445 Safety in use of power operated doors - Test methods Please check normative bellow. VDE-regulations - EN 418 Safety machinery Emergency stop equipment functional aspects Principles for design - EN 60204-1 / VDE 0113-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements - EN 60335-1 / VDE 0700-1 Safety of household and similar electrical appliances - Part 1: General requirements Regulations - Please ensure that the local regulations relating to the Safety of Operations of Doors are followed E 2

SAFETY DIRECTIONS 52220004 Explanation of warnings These operating instructions contain directions which are important for using the ELEKTRO- MATEN appropriately and safely. The individual directions have the following meaning: DANGER This indicates danger to the life and health of the user if the appropriate precautions are not taken. CAUTION This warns that the ELEKTROMATEN or other materials may be damaged if the appropriate precautions are not taken. General warnings and safety precautions The following warnings are to be understood as a general guideline for working with the ELEKTROMATEN in conjunction with other devices. These directions must be observed strictly during installation and operation. Please observe the safety and accident prevention regulations valid for the specific application. The installation of the ELEKTROMATEN, the opening of covers or lids and electrical connection must be carried out when the supply is switched off. The ELEKTROMATEN must be installed with the authorised coverings and protective devices. Care should be taken that any seals are fitted correctly and screw couplings are tightened correctly. In the case of ELEKTROMATEN with a permanent mains connection, an all-pole main switch with appropriate back-up fuse must be provided. Check live cables and conductors regularly for insulation faults or breakages. When a fault is detected in the cabling, the defective cabling should be replaced after immediately switching off the mains supply. Before starting operation, check whether the permissible mains voltage range of the devices corresponds to the local mains voltage. Emergency stop devices in accordance with VDE 0113 (EN60204) should remain operational in all operating modes of the control. Releasing the emergency stop device should not cause any uncontrolled or undefined restart. E 3

ELECTRICAL CONNECTION 52310067 Warning! Danger to life through electric shock Before starting assembly, disconnect the cables from the electricity supply and check that they are dead. Assembling the control The control and the wiring is for indoor use only. Only trained electrical craftsmen should work on electrical equipment. They must assess the work which has been assigned to them, identify potential danger sources and take suitable safety precautions. External fuse! Control must be saved against short circuit and overload by an external fuse, max. 10A delayed, in the mains supply. An automatic cut off switch is required, regarding the supply for three-phase or single-phase. When connecting control to mains supply a mains isolator switch or (16A CEE plug) according EN 12453 is required. The following tools are recommended for the appropriate electrical connection of the ELEKTROMAT : Multimeter (for alternating current up to at least 750 VAC) Electrically insulated screw driver Cable stripper Diagonal cutter Piercing tool to open the cable ducts Wire end ferrules with associated pinching tongs when using flexible cables In order to connect the ELEKTROMAT electrically, the lid of the reversing contactor housing must first be removed. After loosening the two lid screws, the housing lid can be swiveled about 45 (Fig.1) and removed. The cable ducts in the reversing contactor housing must be opened with a piercing tool. The hole in the cable duct should be smaller than the cable diameter to ensure sealing. When the cable duct is opened with a knife or a screw driver, sealing cannot be guaranteed. The cables should be connected in accordance with the primary electrical circuit diagram. The 3 phases of the incoming supply are connected to the contactor K1 with the terminals L1/L2/L3, the neutral conductor is connected to terminal strips designated N. For single phase the incoming supply are connected to the contactor K1, phase L1 and neutral to designated terminal N. The PE (earth) conductor are connected to the terminal strips designated PE. E 4

ASSEMBLY OF THE REVERSING CONTACTOR BOARD 52310068 The use of non-interchangeable connectors for the limit switch make it easy to assemble and/or change the reversing contactor board. If necessary, the complete reversing contactor housing can be removed, after loosening the two mounting screws, and mounted next to the ELEKTROMAT. When doing so, the following steps should be carried out: Assembly /Disassembly:: - Mount the reversing contactor housing (Fig. 1) - Insert the connecting cable with the cable duct into the gearbox housing - Plug in 5 - pole motor socket (Fig. 3 / 4 / 5) - Insert the limit switch plug whilst holding the entire limit switch board firmly with the other hand (Fig. 2) - Check limit switch adjustment - Mount limit switch cover Realise disassembly by following the steps backwards. Fig. 1: Reversing contactor housing Fig. 2: Limit switch plug Fig. 3: Motor Terminal Rail for 3x500V/400V/230V Fig. 4: Motor Terminal Rail for single-phase motor asymmetric winding Fig. 5: Motor Terminal Rail for single-phase motor symmetric winding Check that all screw connections are secure before operating the control and adjusting the limit switches. Check incoming supply before connecting the mains supply / in terminals transformer. (X6, wire link G) E 5

REVERSING CONTACTOR BOARD UNIVERSAL 52370099 The control consists of a printed circuit board with a pair of reversing contactors for opening (K1) and closing (K2). Different functions can be achieved by interchanging wire links. Fig. 6) : Reversing contactor board for: 3 x 380/400V AC, N, PE or 3 x 380/400V AC, PE 3 x 460V AC, PE (special execution); 3 x 220/230V AC, PE; 3 x 500V AC, PE (special execution) U V W 40015734 L1 L2 L3 K1 K2 Fig. 7) : circuit board for: 1 x 220/230V with symmetric winding Fig. 8) : circuit board for: 1 x 220/230V with asymmetric winding E 6

WIRE LINKS ON THE REVERSING CONTACTOR BOARD 52370100 Wire links A: These wire links are absolutely necessary for the operation of the door. By removing the wire links, the control voltage is interrupted and electrical operation of the door is no longer possible. Additional safety switches, e.g. interlocking switches or slack wire switches, can be connected instead of the wire links A. Wire link B: This wire link is necessary for the latching function*) during the opening movement. By removing the wire link, the door can only be opened in dead man' mode*). For shutters which are able to lift a person, a high level safety device is required. Wire link C: By connecting a safety edge device with a relay contact (in place of the wire link), the door operation is latching during the closing operation. If no safety edge device is connected, the door can only be closed in dead man mode. Wire link D: This wire link is used for single-channel radio control or for operation with a pull switch. With the first command, the door opens and travels to the fully open position If a second command is given when the door is in the fully open position, the command is re-routed via the link D and the door travels to the fully closed position If the door is stopped between its end positions, e.g. with a stop command, the next command causes the door to open. Wire links E + F: These wire links are absolutely necessary for operation of the door. Additional safety switches can be connected instead of the wire link E (which interrupts opening) and F (which interrupts closing). Wire link G: This wire link is requested to choose the incoming mains supply. Wire link G terminal T1 to T2 = 1 x 220/230V AC, N, PE; 3 x 220/230V AC, PE 3 x 460V AC, PE (special execution) Wire link G terminal T2 to T3 = 3 x 380/400V AC, N, PE; 3 x 380/400V AC, PE; 3 x 500V AC, PE (special execution) *) Latching = Once an impulse is given the door carries on moving independently Dead man mode = Door only moves as long as an impulse is given E 7

PRIMARY ELECTRICAL CIRCUIT 3 x 220/230V AC, PE 52380076 + - F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection G1 Rectifier EGR II OPTION K1 OPEN Contactor K2 CLOSE Contactor M1 Motor S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 380/400V - 220/230V / 24VAC Y1 Spring tension brake if required 103V DC OPTION X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 8

PRIMARY ELECTRICAL CIRCUIT 3 x 380/400V AC, N, PE 52380077 + - F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection G1 Rectifier EGR II OPTION K1 OPEN Contactor K2 CLOSE Contactor M1 Motor S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 380/400V - 220/230V / 24VAC Y1 Spring tension brake if required 103V DC OPTION X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 9

PRIMARY ELECTRICAL CIRCUIT 3 x 380/400V AC, PE 52380084 + - F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection G1 Rectifier EGR II OPTION K1 OPEN Contactor K2 CLOSE Contactor M1 Motor S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 380/400V - 220/230V / 24VAC Y1 Spring tension brake if required 103V DC OPTION X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 10

PRIMARY ELECTRICAL CIRCUIT 3 x 460V AC, PE (special execution) 52380085 + - F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection G1 Rectifier EGR III OPTION K1 OPEN Contactor K2 CLOSE Contactor M1 Motor S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 460V - 230V / 24VAC Y1 Spring tension brake if required 103V DC OPTION X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 11

PRIMARY ELECTRICAL CIRCUIT 3 x 500V AC, N, PE (special execution) 52380086 + - F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection G1 Rectifier EGR III OPTION K1 OPEN Contactor K2 CLOSE Contactor M1 Motor S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 500V - 460V / 24VAC Y1 Spring tension brake if required 130V DC OPTION X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 12

PRIMARY ELECTRICAL CIRCUIT 1 x 220/230V AC, N, PE SYMMETRIC WINDING 52380078 C1 Capacitor F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection K1 OPEN Contactor K2 CLOSE Contactor M1 Single-phase motor symmetric S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 380/400V - 220/230V / 24VAC X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 13

PRIMARY ELECTRICAL CIRCUIT 1 x 220/230V AC, N, PE ASYMMETRIC WINDING 52380079 T1 T2 T3 C1 Capacitor F0 Fusing on the building supply side F1 Control Fuse 1A F2 Faulty current fuse 0,33A F3 Thermal protection K1 OPEN Contactor K2 CLOSE Contactor M1 Single-phase motor asymmetric S0 Main switch supply side S1 Safety limit switch OPEN S2 Safety limit switch CLOSE S3 Limit switch OPEN S4 Limit switch CLOSE S10 Manual interlock switch S11 Built-in OPEN push-button S12 Built-in STOP push-button S13 Built-in CLOSE push-button S14 Control Button OPEN S15 Control Button STOP S16 Control Button CLOSE T1 Transformer 380/400V - 220/230V / 24VAC X1-7 PCB Terminal Rail X12 Limit Switch Terminal Rail X13 Motor Terminal Rail 2 = Wirenumber E 14

ELECTRICAL CONTROL 52385050 only for "Safedrive - Compact" E 15

ADDITIONAL LIMIT SWITCHES 52345024 The switching cams of the additional limit switches are adjusted as described for the operational limit switches (Mechanical operating instructions). After tightening the coarse adjustment screw, the switching point can be corrected with the fine adjustment screw. 5th and 6th Additional limit switches (available for "Safedrive - Compact") The ELEKTROMATEN is equipped with two additional limit switches (S5 / S6). Both additional limit switches are designed as volt-free changeover contacts and can be used in both directions of movement of the door. Limit switch board Limit switch board Reversing contactor board Reversing contactor board 5th and 6th + 7th Additional limit switches (on request) (7th limit not available with "Safedrive - Compact") The ELEKTROMATEN is equipped with three additional limit switches (S5/S6/S7). These additional limit switches can be used as volt-free make and / or break contacts in both directions of movement of the door. For example, the diagram shows the connection wiring for two make contacts and one break contact. The desired function (make or break contact) of the respective limit switch can be determined by interchanging the connection cables. Limit switch board Reversing contactor board E 16

CONTROL DEVICES - TYPES OF CONNECTION 52315042 For connection 1-9: S14 OPEN S15 STOP / EMERGENCY STOP S16 CLOSE S17 ON - OFF S18 OPEN-CLOSE Connection type 1: Connection type 2: 1 2 Connection type 1: Operation of the door by a 3- push-button station with a latching emergency stop button Connection type 2: Operation of the door by a 3- push-button station with an integrated key-switch Connection type 3: Operation of the door by a 3- push-button station with latching emergency stop button and a 3- push-button station with an integrated key-switch for switching off all control devices. Connection type 4: Operation of the door by a 3-push-button station with a latching emergency stop button and a 3- push-button station with an integrated key-switch to isolate the latter push-buttons. Connection type 5: Operation of the door OPEN/CLOSE by a keywitch with a stop button and a 3-push-button station with an integrated key-switch. Connection type 6: Operation of the door OPEN/CLOSE by a keywitch with a stop button. Connection type 7: Operation of the door OPEN/CLOSE by a keywitch with a stop button and a 3- push-button station. Connection type 8: Operation of the door by a 3- push-button station and a single-channel radio control (safety-edge necessary) Connection type 9: Operation of the door by a 3- push-button station and a cord-operated ceiling switch (safety-edge necessary) Connection type 10: Connection of a reflex photo-beam in the selfholding closing circuit (safety-edge necessary) E 17

CONTROL DEVICES - TYPES OF CONNECTION 52315043 1 2 1 2 Connection type 3: Connection type 4: 1 2 Connection type 5: Connection type 6: E 18

CONTROL DEVICES - TYPES OF CONNECTION 52315044 Connection type 7: Connection type 8: A1 EVALUATION SAFETY EDGE A2 RADIO RECEIVER S STOP CONTACT W REVERSING CONTACT S5 PRE - LIMIT Connection type 9: A1 EVALUATION SAFETY EDGE A3 CORD OPERATED PULL SWITCH S STOP CONTACT W REVERSING CONTACT S5 PRE - LIMIT A1 EVALUATION SAFETY EDGE S STOP CONTACT A4 REFLEX-PHOTO-BEAM W REVERSING CONTACT S5 PRE - LIMIT Connection type 10: E 19

HELP WITH CORRECTING FAULTS 52392009 Fault Drive motor will not run and the contactors K1 or K2 will not pull in Possible cause No voltage at the connecting terminals L1 / L2 / L3 three-phase motor L1 / N single-phase motor Control fuse F1 defective F2 Faulty current fuse Motor protection (thermal switch) in the motor actuated by overloading or exceeding the starting duty. Safety limit switch has interrupted the control circuit External safety switches (slack wire switches or pass door switches) have interrupted the control circuit Switch for emergency manual operation has interrupted the control circuit Connecting screws on the connector or the terminal strips have become loose. Defect in the door mechanism Fault Door no longer closes in latching mode Possible cause Safety edge has been actuated, photobeam has been interrupted Correction Measure the voltage. Compare: three-phase motor single-phase motor L1 with N L1 with N L2 with N L3 with N Where there is no voltage, check the fusing and the power supply on the attachment side check all srew connection s on contactor keep attention the mains supply is disconnected. Check connected control devices (e.g. keyoperated push-buttons) for earth faults and short circuits. After correcting faults, insert replacement fuse supplied. Control has received an open and close command simulataneously, please check, all inputs are operating correctly. After the motor winding has cooled, operation is once again possible through the operation of a control device. Release the Safety limit switch again using emergency manual operation. Check adjustment of operating clearance from the working limit switch to the Safety limit switch and correct where necessary. Check safety switches and replace where necessary. Check the emergency manual operation switch by operating several times. With the current switched off, check all connecting screws are tight and tighten where necessary. Check door mechanism Correction Check safety edge and its evaluation unit. Check photo-beam and re-align where necessary. www.gfa-elektromaten.de E 20

LIFETIME / DOORCYKLES 52396005 The GfA control panels working with electro mechanical contactor boards. Contactor boards having generally a limited life time; this depends on the switched power of ELEKTROMATEN in use and the amount of switching cycles. Therefore we recommend a replacement for control boards in use after doors having reached their confirmed lifetime cycles. Coherence between power and amount of cycles for ELEKTROMATEN describes diagram bellow. Torzyklen Cycles according nach to EN DIN12433-2 EN 12433-2 1000.000 900.000 800.000 700.000 600.000 500.000 400.000 3~ 230/400V, 50Hz 300.000 200.000 1~230V, 50Hz 100.000 0,25 0,50 0,75 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 Leistung in kw Power in KW E 21