HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

Similar documents
Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Pressure Relief Valve DB12 CE

Proportional Pressure Reducing Valve PDM08130

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

Price List 2018 Hire Equipment

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

EX-REPAIR AND MAINTENANCE RECEPTACLES

HYDRAULIC POWER UNITS PO 4

Permanent Gauging Blocks Installation Instructions

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Oil-free piston compressors KK and piston vacuum pumps KV

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Pressure switch hex 27

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Clamping and drive module

Safety Equipment for Hydraulic Accumulators

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Pressure switches hex 24

Crimping and cutting tools FHP 2 PHD 1. Hydraulic drive units. Foot pump 700 bar

Explosion-Protected Pressure Switches

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

HYDAC (Three-Phase Current) Compact Power Units CO1

Oil/Air Cooler Units

Metal Bellows Accumulators for Heavy Diesel Engines

Pneumatic Metering Pump II 3 12 l/h

Safety Equipment for Hydraulic Accumulators

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

Charging and testing unit FPU for Bladder, Piston and Diaphragm Accumulators

Diaphragm pressure switches up to 42 V with brass housing. Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) 1) Male thread

Price List 2013 In-House Repairs and Calibration

Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) 1) Male thread

Reliable fuel effi cient engines. Energy effi cient compressor rotor design built to close engineering tolerances.

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Backflushing Filter AutoFilt RF3

Feed Pumps VP / VPB / VPBM

Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

VT Oil-Free Range Operators Handbook

CGT Series Adjustable Pitch Fans

Spare Parts List Mobile Spin-On Filters MF/MFD. Flow rates up to 300 l/min Pressure range up to 8 bar Material: Aluminium / Sheet Steel

Automatic Back-Flushing Filter AutoFilt RF9.

Automatic filter AF 172 G

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

Vane pumps, direct controlled Type PV7...A

Water Cooled Air Compressors. The most convenient, efficient and effective way to cool your high pressure compressor.

Feed Pumps Direct Drive Series 1.1.

Automatic filter AF 173 G

Mounting Components. Mounting Components 70 INNOVATIVE FLUID POWER. HS - Regular Duty Clamp. Function. HSS - Heavy Duty Clamp.

original operating manual Operating manual Translation of the Item-No.: ,

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

Screw Compactor without feeding device

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK

Automatic metal-edge filters AF 72 G

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

Inclined Platform Lifts SUPRA & SUPRA LINEA

D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

From 6 litres 2 HP To 500 litres 10 HP

Pressure Compensated Flow Control Valves SRVR/SRVRP

Spare Parts List Return line filter RF

Automatic filter AF 153 G

Pressure Switches 30 A/F

Automatic metal-edge filter AF 73 G/AF 93 G

Hydraulic primary unit Type ABPAG

TECHNICAL INFORMATION

Pressure Transmitters

Sound Attenuated Enclosures Level 1, Level 2 & Level 3. Features ENCLOSURES kva (B Series) Range

PUREFLO 21 4-CHAMBER DIAPHRAGM PUMPS

MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS

Diaphragm/piston pressure switches 250 V

Accumulator Safety Blocks

Feed Pumps Direct Drive Series 1.1.

Automatic metal-edge filter AF 71 G

TECHNICAL INFORMATION

Swing Piston Compressors and Vacuum Pumps

Type Description Order Nº Packing Qty. IP 65 junction box complying with DIN VDE 0606, U i

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Mobile Filter Unit MFU-15

HYDAC ACCUMULATORS DEVELOPMENT AND ENGINEERING

RESOL SBS 1000 * * Connection Operation

Accumulator charging valves & kits

Fixed Displacement Plug-In Motor A2FE

KV550C2. Optional control panel POWER

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

8 Technical Reference

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

Workshop manual PW 345C, PW 350, PW 360

Transcription:

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm and piston accumulators. They guarantee optimum use of commercially available nitrogen bottles up to a residual pressure of 20 bar and a maximum accumulator pressure of 350 bar.

A) DESCRIPTION Depending on the model, N 2 Server nitrogen charging units are suitable for charging small accumulators, and for pre charging or topping up accumulator stations. A piston accumulator is installed as the nitrogen pump. N 2 Server nitrogen charging units are equipped with a pressure safety valve which complies with Pressure Equipment Directive 97/23/EC. B) TYPES OF N 2 SERVER 1. N2S M Nitrogen charging unit N 2 Server Mobile 2. N2S T Portable nitrogen charging unit N 2 Server, without oil supply unit 3. N2S V Portable nitrogen charging unit N 2 Server, with oil supply unit 4. N2S F Mobile nitrogen charging unit N 2 Server 5. N2S S Stationary nitrogen charging unit N 2 Server C) SAFETY INFORMATION When charging hydraulic accumulators or accumulator systems, if the permissible operating pressure of the accumulator system is lower than the pressure in the nitrogen bottles used for filling, a pressure reducer valve must be connected to the gas bottle and must be adjusted to the required pre charge pressure. (Please also refer to brochure no. 3.501, Charging and Testing Unit FPU 1) Hydraulic accumulators must only be filled with nitrogen N 2 (oxygen free), and not with oxygen or air. Danger of explosion! D) COMMISSIONING In accordance with the operating instructions supplied with the unit. E) NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 2

1. NITROGEN CHARGING UNIT N 2 SERVER MOBILE N2S M 1.1. DESCRIPTION N 2 Server N2S M is suitable for charging small accumulators or for topping up the gas pre charge pressure in large accumulator stations. It consists of an oil supply unit, the electrical and hydraulic controls, the piston accumulator and the connection hoses. The hydraulic and electrical operating controls are grouped together ergonomically on the front panel. N 2 Server N2S M is extremely compact and can be moved easily by one person. 1.2. TECHNICAL SPECIFICATIONS Total weight of the unit when full: approx. 98 kg fluid: 320 bar max. Pressure gauge indication range: 0 400 bar Flow rate: 0.9 l/min Tank size: approx. 8 l Hose length: bottle side: 4 m accumulator side: 3m 1 l Three phase motor: 230/400 V 50 HZ Output: 0.75 kw Safety type: IP 55 Electrical connection: CEE plug, 5 pole, 16 Amp for 400 V Cable length: 5 m 1.3. DIMENSIONS N2 Server N2S M approx. 1100 N 2 outlet N 2 intlet approx. 510 approx. 570 3

2. PORTABLE NITROGEN N 2 SERVER WITHOUT OIL SUPPLY UNIT N2S T 2.1. DESCRIPTION N 2 Server N2S T is suitable for charging small accumulators or for topping up the gas pre charge pressure in large accumulator stations. It consists of a piston accumulator and the electrical and hydraulic controls. N 2 Server N2S T must be connected to an existing hydraulic system. The user must ensure that the pump flow rate of the hydraulic unit does not exceed 8 l/min. 2.2. TECHNICAL SPECIFICATIONS Dimensions: Height: 300 mm Width: 260 mm Length: 600 mm Total weight: 25 kg fluid: 300 bar max. Hose length: bottle side: 4 m accumulator side: 3m 1.5 l Electrical connection: earthing contact type plug, industrial model 230 V - 50 Hz Cable length: 1 m approx. 320 2.3. DIMENSIONS approx. 780 N 2 inlet N 2 outlet approx. 320 4

3. PORTABLE NITROGEN N 2 SERVER WITH OIL SUPPLY UNIT N2S V 3.1. DESCRIPTION N 2 Server N2S V is suitable for charging small accumulators or for topping up the gas pre charge pressure on large accumulator stations. It consists of an oil supply unit, the electrical and hydraulic controls, a piston accumulator and the connection hoses. 3.2. TECHNICAL SPECIFICATIONS Total weight of the unit when full: approx. 46 kg Total weight of the piston accumulator: approx. 35 kg fluid: 350 bar max. Pressure gauge indication range: 0 400 bar Flow rate: 1.6 l/min Tank size: approx. 13 l Hose length: bottle side: 4 m accumulator side: 3m 1.5 l Three phase motor: 230/400 V 50 HZ Output: 1.1 kw Safety type: IP 55 Electrical connection: CEE plug, 5 pole, 16 Amp for 400 V Cable length: 1 m 3.3. DIMENSIONS Oil supply unit approx. 580 approx. 360 approx. 620 Compressor approx. 100 approx. 530 approx. 130 approx. 350 approx. 285 N 2 outlet N 2 inlet 5

4. MOBILE NITROGEN N 2 SERVER N2S F 4.1. DESCRIPTION N 2 Server N2S F is designed for charging large accumulator systems. It consists of a complete power pack, piston accumulator, electrical controls and hoses, compactly mounted on a trolley. A charging and testing unit FPU is supplied with the server. 4.2. TECHNICAL SPECIFICATIONS Total weight of the unit when empty: approx. 380 kg fluid: 350 bar max. Pressure gauge indication range: 0 400 bar Flow rate: 8 l/min Tank size: approx. 40 l Hose length: both 4 m 2.5 l Three phase motor: 230/400 V 50 Hz Output: 5.5 kw Safety type: IP 55 Electrical connection: CEE plug, 5 pole, 16 Amp for 400 V Cable length: 10 m 4.3. DIMENSIONS approx. 1400 1000 approx. 1000 825 6

5. STATIONARY NITROGEN N 2 SERVER N2S S 5.1. DESCRIPTION N 2 Server N2S S is identical to the mobile nitrogen charging unit N 2 Server N2S F as far as the hydraulic and electrical controls are concerned. The difference lies in the construction, which is intended for stationary applications. 5.2. TECHNICAL SPECIFICATIONS See point 4.2. 5.3. DIMENSIONS approx. 1270 1000 825 7