Bottom Loading & Recirculation Adapters

Similar documents
Maintenance Manual. Dry Break Quick Disconnect (Old Style) Model SM November 1, 2011 Applicable additional manuals: SM60427 Nozzle

Quick Disconnect To Mate Nozzle. Model SM40679 August Applicable additional manuals: SM60427 Nozzle SM Hose End Regulator

Maintenance & Repair Manual. Misc. Male Adapters To Mate Model Nozzles And Model Couplers. SM427MISC June 1, 1993

Non-Valved Unisex Coupling

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

Swivel Quick Disconnect To Mate Various Carter Brand Nozzles. Model SM Maintenance & Repair Manual

3 Inch & 4 Inch Digital Bypass Pressure Control Valves

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

Model Maintenance Manual SM July 2011

3 Inch & 4 Inch Fuel Operated Bypass Pressure Control Valves. Models & 64513

SM64155 Maintenance & Repair Manual

Maintenance & Repair Manual

Models & & 4 Air Operated Bypass Pressure Control Valves SM64501

Miscellaneous Male Adapters To Mate Nozzle Models & 64348

Unisex Couplings, Valved. Model Model SM October Applicable additional manuals: None. Maintenance Manual

SM Pressure Fueling Nozzle Standard Commercial Unit. Model Maintenance Manual

Model Maintenance Manual. SM44646 October Applicable additional manuals:

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Carter Underwing Refueling Nozzle. Model 64349

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals:

Digital III Fueling Vehicle Control System

Solenoid Valve Manifold for use with Digital Pressure Control Coupler

S E R V I C E B U L L E T I N

REFILL STATION REBUILD KIT P/N 14270NOS

Digital Manifold with Digital Hydrant Control

Carter Underwing Refueling Nozzle Model 60427

Maintenance Manual HOSE END PRESSURE CONTROL VALVE F594 / F595 SERIES

OTECO INC. 2 RESET RELIEF VALVE 2 L.P.T. INLET & OUTLET INSTALLATION & MAINTENANCE MANUAL PART NO

Maintenance & Repair Manual. 4 Inch Hydrant Coupler For Digital Pressure Control To Mate Hydrants In Accordance With Bulletin API 1584.

7 Emergency Breakaway Fuel Coupling

Carter Pressure Fueling Nozzle Model 64200

Model Maintenance & Repair Manual. 3 x 4 Inch Hydrant Coupler with Pressure Control To Mate Hydrants in Accordance with API Bulletin 1584

3 X 4 Inch Hydrant Coupler for Digital Pressure Control To Mate Hydrants in Accordance with API Bulletin Model Maintenance Manual SM64802

Maintenance Manual 6-INCH INTERNAL VALVE F620 SERIES

Maintenance Manual. 4-Inch Internal Valve. F614 Series

Hydrant Valve In Accordance With Bulletin API Model SM Maintenance & Repair Manual. January 2011

F582/F584 MAINTENANCE MANUAL

Operation and Maintenance Manual

Maintenance Manual. Hydrant Coupler. F250 Series

Property of American Airlines

Carter Ground Fueling Underwing Refueling Nozzle Model 64349

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

Service Sheet SSJ0452P. J0452 Coupler with Pump API Coupler

Maintenance Manual UNDERWING REFUELING NOZZLE F116 SERIES

Model Hydrant Coupler with Pressure Control To Mate Hydrants In Accordance With API Bulletin 1584 SM Maintenance & Repair Manual

Binks MODELS & AGITATOR DRIVE UNITS

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

4. Control Valve (Power Steering Gearbox)

SD Bendix AR-1 AntiLock Relay Valve DESCRIPTION EMBOSSED IDENT. AR-1 VALVE AIR CONNECTION

MODEL VFF30 REPAIR KIT INSTALLATION INSTRUCTIONS

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

ORIGINAL INSTRUCTIONS G700

Pressure refuelling nozzles F145 series

BFMM DC4A SBF EFFECTIVE AUGUST 1, 2016

Aeroquip 3200 Series Self-Sealing Quick Disconnect

TS1251 PRESSURE DISPENSER USER'S MANUAL

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

INSTRUCTIONS-PARTS LIST

INSTRUCTION MANUAL. CR Series A/B

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

TYPE E Main Valve Sizes 3 /8 through 12

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

SD Bendix E-12 & E-15 Dual Brake Valve DESCRIPTION

Temperature Regulator I-1285-B through G Series (Bronze Valve Body)

LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE

Model No. 668D3. COFFEPUMP Part No Product Code: O/C GJAN21.DB6B-DC310B

1996 Contour/Mystique

PNEUMATIC PIPING DEVICES Service Information

Maintenance Manual. 3-Inch Internal Valve. F660 Series

Maintenance Manual 3-INCH INTERNAL VALVE F660 SERIES

Carter Hydrant Pit Valve 4th Edition EI 1584 Model 60554

TYPE S RELAY VALVE (Volume booster) Service Manual

Carter Ground Fueling Pressure Refueling Nozzle Model 64348

MULTIPOSITION AIR CYLINDER

Carter Ground Fueling Underwing Refueling Nozzle Model 60427

380GF Series Sexless Coupler : 3-Inch

Eaton Hydraulic Motor. Repair Information. Series VIS 45. January, 2000

REPAIR PROCEDURES MANUAL

DESCRIPTION FUEL AND VACUUM PUMP REMOVE AND REPLACE FUEL PUMP-OVERHAUL 6B PONTIAC SHOP MANUAL. S. Install battery and connect cables.

Eaton Hydraulic Motor. Repair Information. 30 Series. July, 1996

DP Series Diaphragm Valve Installation and Maintenance Instructions

351GF-15. Hydrant Coupler INSTALLATION / OPERATION / MAINTENANCE MODEL

Document No.: VWI This document is electronically controlled. Printed versions are uncontrolled and for reference only.

Carter Ground Fueling Pressure Refueling Nozzle Model 64348

SD Bendix SR-5 Trailer Spring Brake Valve DESCRIPTION PORTS. 1-1/2" or 3/4" NPT Spring Brake Reservoir Mounting (SPR BK RES)

No July, Eaton. Hydraulic Motor. Repair Information. 30 Series VIS Bearingless Motor 002

GROUP 8 MAIN CONTROL VALVE

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1)

THD-2-FM CONTROLAIR VALVE

SECONDARY SERVICE EXTERIOR R-12DC VALVE (MODEL WITH 4 VERTICAL DELIVERY PORTS) DELIVERY COVER SECONDARY RELAY PISTON VALVE RETAINER INLET EXHAUST

TECHNICAL SERVICE MANUAL

Maintenance Manual 4½-INCH INTERNAL VALVE F635 SERIES

Service Guide. High-Pressure Grease Pump. 100 psi (6.8 bar) High-Pressure Pump Model 7785 Series Specifications

SD Bendix TP-3DC Tractor Protection Valve with Double Check DESCRIPTION

HFB Steering Gear Service Manual

KHR Series Regulators

Installation & Parts Manual K-7, K-15, & K-30 Air Actuated & Differential Check Valves

Carter Ground Fueling Underwing Refueling Nozzle Model 64250

Transcription:

SM60373 January 2002 Aerospace Group Conveyance Systems Division Carter Brand Ground Fuelin Equipment Applicable additional manuals: None Maintenance Manual Bottom Loading & Recirculation Adapters Models 60195, 60373, 64373 & 64573

Table of Contents Page 1.0 Introduction... 3 2.0 Equipment Description... 3 3.0 Table Of Options... 3 4.0 Disassembly... 3 5.0 Inspection... 4 6.0 Reassembly... 4 7.0 Test... 4 8.0 Illustrated Parts List... 5 Figure 1... 6 2

Maintenance, Overhaul & Test Instructions Carter brand Models 60195, 60373, 64373 & 64573 Bottom Loading & Recirculation Adapters 1.0 INTRODUCTION This manual furnishes detailed instructions covering the maintenance and overhaul of Carter brand Models 60195, 60373, 64373, & 64573 bottom loading and recirculation adapters. These units all utilize the MS29514 type refueling 9-bolt flange adapter. 2.0 EQUIPMENT DESCRIPTION These Carter units are all of similar design in that they all utilize the 2-½ MS29514 type refueling 9- bolt flange adapter. This type of adapter is suitable for use in bottom loading, recirculation or hydrant pressure applications where a 2-½" type adapter is required These adapters consist of a cast aluminum housing which contains an internal support bearing for the adapter poppet. A 9-bolt flange joins the housing and adapter flange. All of the models discussed are similar, varying mainly in the outlet mounting configuration. 3.0 TABLE OF OPTIONS Each of the basic units may be obtained in various configurations by adding one or more of the options listed in the tables below. Model 60195 2-½" threaded inlet by 2-½" bayonet Option Letter Description Comments A Deletes product selection feature In lieu of standard positions 4, 5 & 6 selection B* Adds relief valve to poppet In lieu of option F without valve. E Adds pressure dust cap In lieu of option J F* Adds standard poppet valve In lieu of option B with relief valve. G** Adds 2½"-8 NPT threaded inlet In lieu of option H. H** Adds 2½"-11 BSPP threaded inlet In lieu of option G. J Adds plastic dust cap In lieu of option E. * Either option B or F must be included in the part number to achieve a completed part number. ** Either option G or H must be included in the part number to achieve a completed part number. Models 60373, 64373 & 64573 4 flange by 2-½" bayonet Option Letter Description Comments *A Adds product selection feature, positions 4, 5 In lieu of option F. & 6. **B Adds relief valve to poppet In lieu of option E. C Adds pressure dust cap D Adds plastic dust cap **E Adds poppet without relief valve In lieu of option B. *F Deletes product selection feature In lieu of option A. * Either option A or F must be added to the part number to achieve a completed part number ** Either option B or E must be added to the part number to achieve a completed part number 4.0 DISASSEMBLY Refer to Figure 1 for an exploded view of the Unit. 4.1 Remove Cap (1 or 1A) from unit if present. Remove nine Screws (2) and Product Selection Ring (13), if present. Pull Adapter Flange (3) from Housing (4). Remove and discard O-ring (5). Remove Poppet (6 or 6A) and Spring (7). Note on 3

older 60195 Adapters, O-ring (5) is replaced with Gasket (5A). Discard if present. 4.2 Spare parts for the Cap (1) are not available. If it is faulty replace as a complete unit. 4.3 On option B units, it is possible to disassemble the Poppet (6A) to replace the relief valve Seal (8). Remove Nut (9) and then the Seal (8). Discard Seal (8). 5.0 INSPECTION 5.1 Special Tools - Use Adapter Wear Gauge, 61657-2 to check the Flange (3) for suitability for continued use. Refer to manual SM61657 for instructions on its use. This gauge will indicate whether the slots and lugs of the Flange (3) are worn beyond safe use. 5.2 Check the seal on Cap (1) for deterioration, cuts or nicks. Replace the Cap (1) if such aberrations are apparent. 5.3 Check Cap (1A) for aging cracks or other damage. Replace as needed. 5.4 Inspect Poppet (6 or 6A) for damage to the seal. The seal is bonded into the metal poppet and is not removable. Replace Poppet (6 or 6A) as needed. 6.0 REASSEMBLY 6.1 Reassembly is accomplished in essentially the reverse order of disassembly noting the following: 6.2 Light lubrication of all O-rings and seals, using petroleum jelly is recommended to facilitate installation. 6.3 Place Spring (7) inside Housing (4) and insert Poppet. On option B units, apply two drops of Locktite Compound 242, one each on opposite sides of the threaded portion of the Nut (9). Insert Spring (10) into Poppet (12). Install Stem (11) and secure with Nut (9). Torque Nut (9) to 10 ± 5 in-lb (.12 ±.06 kg-m) to retain and align one slot with the slot in the Poppet (6A). 6.4 Place the O-ring (5) in the groove in Adapter Flange (3) before installing in the Housing (4). Torque Screws (2) to 20 ± 2 in-lbs (.23 m-kg). 6.5 Reattach Cap (1) or (1A) to tab on Adapter Flange (3) if utilized. 7.0 TEST 7.1 The following test procedures will be accomplished after overhaul: 7.2 Test conditions 7.2.1 Test media shall be Stoddard Solvent (Federal Specification P-D-680), JP-4 per MIL-J-5624D at 75 + 15 F, Jet A or equivalent. 7.3 Functional Test 7.3.1 Attach adapter to a 120 psi fluid pressure source through the outlet (flanged or threaded end). Attach a Carter 60427 or 64348 type nozzle to the inlet. The nozzle shall be plugged at the inlet end with a plug and a small petcock or hand valve. With the nozzle and petcock open, slowly increase the pressure into the adapter outlet to fully bleed the air from the test unit. Close the petcock and increase the test pressure to 120 psi. Check for external leakage from the joint between the nozzle and adapter and from the adapter housing and joints. 7.3.2 Bleed the pressure from the test unit and remove the nozzle. 7.3.3 Slowly increase the system pressure again to 120 psi and check for leakage from the unit. 4

8.0 ILLUSTRATED PARTS CATALOG Table 1.0 tabulates the parts and sub-assemblies comprising the various adapters covered by this manual. The item numbers of the table are keyed to the exploded views of the Units diagrammed in Figure 1. TABLE 1.0 Item Part Number Description Qty/ Assy Spares/10 Units/Yr. Used on 1 61531 Cap, pressure 1-60195E & C option for others 1A 41607 Cap, plastic 1 5 60195J & D option for others 2 GF51957-64 Screw 9-60195A & F option for others GF51957-66 Screw 9 - Option A 3 25668 Flange 1 - All 4 20252 Body 1-60195G 27933 Body 1-60195H 28722 Body 1-60373 220040 Body 1-64373 220390 Body 1-64573 5 201201-042 O-ring 1 10 All but early 60195 5A 2772 Gasket 1 10 Early 60195 6 4150 Poppet 1-60195F & E option for others 6A 47011 Poppet Assy 1 - Option B 8 222044 Seal 1 10 9 220045 Nut 1-10 LC022D-5 Spring 1-11 220043 Stem 1-12 220052 Poppet 1-7 2753 Spring 1 - All 13 81068 Product Selection Ring 1 - Option A Notes: 1. All part numbers beginning with "GF" are interchangeable with those beginning with either "AN" or "MS". If the "GF" is followed by three numbers it is interchangeable with and "AN" part, otherwise it is interchangeable with an "MS" part of the same number. 2. The recommended spare parts shown above are the number required to support 10 Units for one year. The recommended quantities are based on the ratio of spare parts sold for each unit during a one year period of time. The actual quantity required will vary from location to location. 5

Figure 1 6

Aerospace Group Conveyance Systems Division 9650 Jeronimo Rd Irvine, CA 92618 Ph (949) 452-9500 Fax (949) 452-9992