SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Similar documents
SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4.

3/2-5/2 ports / positions

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NAMUR, 1/4.

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4 to 1/2

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, 1/4

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4-1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

SPOOL VALVE. solenoid air operated 3/2 G 1/4. SPECIFICATIONS : air or neutral gas, filtered, lubricated or not PORTS : G 1/4 CONSTRUCTION

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NAMUR, 1/4-1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NAMUR, 1/4-1/2

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

SOLENOID VALVES direct operated core disc 1/4

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4-1/2

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

SOLENOID VALVES direct operated core disc 1/4

power level Pneutrol International Ltd are Platinium Distributors for ASCO Numatics

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

MICRO SOLENOID VALVE

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

CABINET MOUNTING. 501 series. Aluminium or stainless steel AISI 316L

CABINET MOUNTING. 501 series

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

503 series. GENERAL Operating pressure

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Intrinsically Safe Miniature Solenoid Valves

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Direct-acting 3/2 way plunger valve

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

SOLENOID VALVES no voltage release (lever type) manual reset construction 3/8 to 1

SOLENOID VALVES pilot operated, high flow, heavy duty single solenoid / dual solenoid 1/4 to 1

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Material pressure (bar) (Cv (US) kv x 1,2 Seat

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES direct operated core disc 1/4

Electro-pneumatic control valves

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

SOLENOID VALVES direct operated, basic flow balanced poppet 1/4

Asia Pacific Express Catalog

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

VALVES Pressure Operated Stainless Steel Body Threaded Ports, 3/8 to 2 1/2

SOLENOID VALVES pilot operated, high flow floating diaphragms 3/8 to 1

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

SOLENOID VALVES direct operated core disc 1/4

SOLENOID VALVES pressure assisted, zero minimum, high flow floating diaphragms 1/4 to 1/2

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

97100 NAMUR. Technical data

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Solenoid Valve Island Type 3965

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

HERION SERIES Indirect solenoid actuated soft seal

Terminal Boxes in Stainless Steel SLS**.T

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

APPLICATION OF SYSTEM 8

Pilot operated solenoid valves for pneumatic actuators

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

SOLENOID VALVES pressure assisted, zero minimum, high flow floating diaphragms 1/4 to 1/2

Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC. Selection and ordering

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Servo-operated 2/2-way solenoid valves Type EV220A

Solenoid valves 2/2-way servo operated type EV220B 15 50

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

System 6. Solenoid Coils Armature Assemblies Valve Systems

SOLENOID VALVES direct operated, basic flow balanced poppet 1/4

VALVES ISO 5599/1, SERIES IPV-ISV

Transcription:

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional Safety data and can be used up to SIL The solenoid operated spool valves have threaded port connections and NAMUR interface The same spool valve can be adapted for / NC or / functions for controlling double-acting and single-acting actuators All the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) The solenoid valves satisfy all relevant EC Directives GENERAL Differential pressure Flow (Qv at 6 bar) - 0 bar [ bar 00 kpa] 700 l/min (ANR) fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, filtered - C to + 0 C () VMQ (silicone) + PUR (polyurethane) () -0 C for air operated versions. MATERIALS IN CONTACT WITH FLUID ( ) Ensure that the compatibility of the fluids in contact with the materials is verified Air operated CNOMO solenoid (pilot) interface Body, end covers Brass, AISI 6L Brass, AISI 6L Interface plates Glass-filled PA Glass-filled PA Spool valve internal parts Brass, stainless st., POM Brass, stainless st., POM Seals NBR NBR Pilot internal parts - Size (E06.6.0N), refer to catalogue pages: 0 pilot (CFSC/CFVT/ CFSCIS) and 60 piezotronic pilot (PISC/ PISCIS) AIR OPERATED SPECIFICATIONS pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) optional basic catalogue number min. air ( ) ( ) (mm) (m /h) (l/min) ~ Pilot air operated - spring return (monostable) / 6 0,7, 0 0 - A0 () Pilot air operated and return (bistable) / 6 0,7, 0 0 - A0 UP LP 0,00W - 0,W 0,W -,W Ultra Low power Low power RP - MP Not available Reduced and Medium power POWER LEVELS - cold electrical holding values (watt) BP Not available Basic power CNOMO SOLENOID (PILOT) INTERFACE SPECIFICATIONS pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) min. air ( ) power level optional solenoids basic catalogue number ATEX / IECEx IP6 Ex ia ( ) (mm) (m /h) (l/min) ~ ~/ CFSCIS PISCIS CFSC CFVT PISC CNOMO / NC - / - Solenoid air pilot operated - spring return (monostable) / 6 0,6 0 0 0 LP - - - C0 () / 6 0,6 0-8 LP m - - - - C0 () / 6 0,6 0 8 8 UP - m - - C0 () / NC - / - Solenoid air pilot operated and return (bistable) / 6 0,6 0 0 0 LP - - - C0 / 6 0,6 0-8 LP m - - - - C0 / 6 0,6 0 8 8 UP - m - - C0 Select 8 for NPT ANSI.0. or select G for ISO G (8/) Available feature Available feature in DC only. () Certified IEC 608 Functional Safety data, use suffix "SL". 6--9 80FR-0/R0

SERIES PREFIX TABLE power level description 6 7 UP LP RP BP C F S C Solenoid + spade plug DIN 60, 9, mm, industry standard B (EN 6070) - - - C F V T Solenoid with connection M, LED + protection (EN 6070) - m - - C F S C I S Intrinsically safe, 9, mm, pilot 0; ATEX (EN/IEC 60079-/6) * - m - - P I S C Solenoid, spade plug DIN 60, 9, mm, industry stand. B, ATEX (EN 6070) - - - P I S C I S Intrinsically safe, piezotronic 60 pilot, ATEX (EN/IEC 60079-/6079-6) * m - - - SUFFIX TABLE suffix power level description 6 7 UP LP RP BP G D Non-electrical, GD c, construction safety, gas/dust (EN 6-) - - - - M S Screw type manual operator () - / - - M O Push type manual operator / / - - S L Certified IEC 608 Functional Safety data / / - - OPTIONS & ACCESSORIES series exhaust pipe protector (stainless steel) G /8 6008 ( ) NPT /8 6008 () M 6008 () Available feature m Available feature in DC only - Not available * ATEX solenoids are also approved according to EN 6- (non electrical valves) () Not to use with "SL" suffix () Provided with "SL" suffix PRODUCT SELECTION GUIDE STEP Select the fluid temperature range and seal material from the general table on page 9. Select basic catalogue number, including pipe thread identification letter. Refer to the specifications tables on page 9. Example: GC0 STEP Select (combination). Select the appropriate operator from the tables on pages 9 and 0. Select for this operator in the electrical characteristics table on page : the power level (UP, LP), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. Example : CFSC STEP Select suffix. Suffix MO mandatory for the pilot 0 (CFSCIS). Refer to the suffix table on page 0, respect the indicated power level. Example : MO STEP Selection of TPL, on page, is mandatory for the 60 pilot (PISCIS), HV DC ( mw) and HV DC ( mw). Add "X" between the "PISCIS" and the basic catalogue number. STEP Select voltage. Refer to standard voltages on page. Example : 0V / 0Hz STEP 6 Final catalogue / ordering number. Example : CFSC GC0MO 0 V / 0 Hz ORDERING EXAMPLES: CFSC G C 0 0V / 0 Hz CFSC G C 0 SL 0V / 0 Hz CFVT 8 C 0 MO 0V / 0 Hz PISCIS G C 0 MO 6V / DC PISCIS G C 0 SLMO 6V / DC PISCIS X G C 0 MS TPL0666 HV / DC G A 0 G A 0 GD G A 0 GDSL G A 0 pipe thread basic number voltage TPL suffix 6--0 80GB-0/R0

EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVES Valve temperature range Operator ambient temperature range Total temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) The operator ambient temperature range is determined by the selected power level and the safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above ELECTRICAL CHARACTERISTICS Coil insulation class F Electrical safety IEC Standard voltages DC () CFSC/CFVT: V CFSCIS: V - V ; PISC: V à 70V ; PISCIS: 6V, 8V, V, V AC (~) CFSC: V - V - 0V/0Hz - Other voltages are available on request PISC: V to 70V power ratings operator electrical ambient replacement coil inrush holding hot/cold temperature enclosure safety code option range (TS) protection type ~ ~ ~ () (VA) (VA) (W) (W) (C ) (EN 609) - - Low power (LP) CFSC,,, /, - to +60 EN 6070 moulded IP6 - - 0 CFSC, (6),6 (6), (6) - - to +60 EN 6070 moulded IP6 - - 0 CFVT () - - -,/, - to +60 EN 6070 moulded IP67/IP6 - - 0 CFSCIS ()() - - - 0, -0 to +0/60 II G Ex ia IIC T6/T Ga, II D Ex ia IIIC Da moulded IP6 - - 0 Ultra low power (UP) PISC - - - 0,007-0 to +60 - moulded IP6 - - 06 PISCIS ()() 6V - - - 0,00-0 to +0 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP6 - - 06 PISCIS ()() 8V - - - 0,0-0 to +0 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP6 - - 06 PISCIS ()() LV - - - 0,0-0 to +0 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP6 - - 06 PISCIS ()() HV - - - 0,0-0 to +0 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP6 - - 06 PISCIS ()() LV - - - 0,06-0 to +0 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP6 - - 06 PISCIS ()() HV - - - 0, -0 to +0 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP6 - - 06 - Not available () Refer to the dimensional drawings on pages and. () Piezotronic standard voltages: Prefix PISCIS: 6 V DC / mw 8 V DC / mw L V DC / mw H V DC / mw L V DC / 6 mw H V DC / mw Turn ON voltage U ON 6.. 9 V 7,.. V 0,8.. 6 V 0,8.. 6 V,6.. 8 V,6.. 8 V Turn OFF voltage U OFF V, V, V, V V V Peak current 6 ma 0 ma 6,8 ma 8, ma 0 ma ma Holding current 0, ma,8 ma ma,7 ma,9 ma, ma Cable + max. barrier resistances (R S + R C ) 00 Ω max. 00 Ω max. 00 Ω max. 70 Ω max. 00 Ω max. 70 Ω max. safety parameters () Intrinsically safe pilots: Check the electrical characteristics in the corresponding catalogue pages (CFSCIS: option U I I I P I L I C I (DC) (V) (ma) (W) (H) (µf) Low power (LP) CFSCIS 8 00,6 0 0 Ultra low power (UP) PISCIS 0 00 0,9 0 0 ELECTRICAL CONNECTIONS connection CFSC, CFSCIS, PISC, PISCIS CFVT ADDITIONAL OPTIONS 0 pilot / PISCIS: 60 pilot). () CFSCIS (0 pilot): V : I (ON) min., with LED ma; U (ON) min.,9 V; U (max.) recommended V; U (OFF), V; I (OFF) 0 ma V : I (ON) min., with LED ma; U (ON) min. 6, V; U (max.) recommended 8 V; U (OFF),7 V; I (OFF) 7 ma () Values for LED + protection. (6) AC: 0 V - Not available SERIES Spade plug connector with cable gland DIN 60, 9, mm, industry standard B, for cables with an outer diameter from to 6 mm M connection for M connector TPL numbers: TPL 066: Piezotronic, PISCIS, HV ( mw) TPL 0666: Piezotronic, PISCIS, HV ( mw) TPL numbers: TPL 067: LED and protection, CFSC - Add 0, W (DC) and 0, W/VA (AC) Only available in V AC/DC and V AC Set of stainless steel mounting screws, catalogue number 9780 Other pipe threads are available on request INSTALLATION Installation/maintenance instructions are included with each valve The solenoid valves and air operated valves can be mounted in any position without affecting operation IEC 608 Functional Safety (suffix SL), allowable temperature range: -0 C to +60 C Check temperature range of valve body and solenoid for suitability. For probability of failure, contact us Spool valve supplied with two interface plates with NAMUR mating surfaces. Depending on function (/ NC or /), position one of the two plates on the spool valve body before installing on actuator Dowel pin (if necessary), bolts and gaskets are standard supplied It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifier is: 8 NPT (ANSI.0.); G G (ISO 8/) Valves with suffix "SL" are provided with a specific exhaust protector 6-- 80GB-0/R0

SERIES DIMENSIONS (mm), WEIGHT (kg) Type 0..06: CNOMO (E06.6.0N) Type 07: Air operated 8 A 9 9 A - ( x /8) ( x /) 6 9 mounting holes:, mm dia. (Spotfacing: 9 mm dia., depth mm) One mm dia. hole for dowel pin: - in position A: / NC function plate - in position A: / function plate O-ring seals (supplied) Exhaust reducer or exhaust protector 6 Interface plate 8 A 0 G/8 A 9 9 - ( x /8) ( x /) 6 9 TYPE 0: CFSC 0 pilot Polyarylamide IEC / DIN 60 TYPE 0: CFVT 0 pilot Polyarylamide IEC / connection M + LED and protection C0 / C0 C0MS / C0MS / C0MO / C0MO C0 / C0 C0MS / C0MS / C0MO / C0MO 60 7 9, M M 90 9 79 7 C0MO / C0MO TYPE 0: CFSCIS 0 pilot Polyarylamide IEC / DIN 60 EN/IEC 60079-/6 C0MO / C0MO TYPE 06: PISC / PISCIS Piezotronic pilot Polyamide IEC / DIN 60 EN 60079-/6 60 7 9 M M 90 9 90 9 80GB-0/R0 6--

SERIES DIMENSIONS (mm), WEIGHT (kg) TYPE 07: Air operated version No Use "SL", "GD" or "GDSL" suffix IP6 / II GD c A0 / A0 0 9 9 Connector rotatable by 90 increments (cable - 6 mm) Connector rotatable by 90 increments (cable 6-7 mm) Manual operator location Connectable pilot exhaust port type option power level weight () monostable bistable 0 CFSC low power 0,876,09 0 CFVT low power 0,876,09 0 CFSCIS low power 0,88,0 06 PISC / PISCIS ultra low power 0,86,06 07 - - 0,8 0,988 () Incl. connector(s), except CFVT. ACCESSORIES B 9 ØA ØA M /8 - B, 0 - exhaust protector (stainless steel) 6-- 80GB-0/R0