SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 NC 0 0 / Series 55 FEATURES The monostable spool valves have TÜV certified IEC 6508 Functional Safety data and can be used up to SIL 4 All the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) The solenoid valves satisfy all relevant EC Directives GENERAL Differential pressure Flow (Qv at 6 bar) - 0 bar [ bar 00 kpa] 860 l/min (ANR) fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, filtered - 5 C to + 40 C () VMQ (silicone) + PUR (polyurethane) () -40 C for air operated versions. MATERIALS IN CONTACT WITH FLUID ( ) Ensure that the compatibility of the fluids in contact with the materials is verified Air operated CNOMO solenoid (pilot) interface Body, end covers Brass, AISI 6L Brass, AISI 6L Spool valve internal parts Brass, stainless steel, POM Brass, stainless steel, POM Seals NBR NBR Pilot internal parts - Size 5 (E06.6.0N), refer to catalogue pages: 0 pilot (CFSC/CFVT/CFSCIS) and 60 piezotronic pilot (PISC/ PISCIS) AIR OPERATED SPECIFICATIONS pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) optional basic catalogue number min. air ( ) ( ) (mm) (m /h) (l/min) ~ Pilot air operated - spring return (monostable) /4 6 0,75,5 0 0-55A07 () Pilot air operated and return (bistable) /4 6 0,75,5 0 0-55A08 UP LP 0,00W - 0,5W 0,5W -,5W RP - MP Not available BP Not available Ultra Low power Low power Reduced and Medium power Basic power POWER LEVELS - cold electrical holding values (watt) CNOMO SOLENOID (PILOT) INTERFACE SPECIFICATIONS pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) min. air ( ) power level optional solenoids basic catalogue number ATEX / IECEx IP65 Ex ia ( ) (mm) (m /h) (l/min) ~ ~/ CFSCIS PISCIS CFSC CFVT PISC CNOMO 5 Solenoid air pilot operated - spring return (monostable) /4 6 0,75,5 0 0 LP - - - 55C507 () /4 6 0,75,5-8 LP m - - - - 55C507 () /4 6 0,75,5 8 8 UP - m - - 55C507 () Solenoid air pilot operated and return (bistable) /4 6 0,75,5 0 0 LP - - - 55C508 /4 6 0,75,5-8 LP m - - - - 55C508 /4 6 0,75,5 8 8 UP - m - - 55C508 Select 8 for NPT ANSI.0. or select G for ISO G (8/) Available feature Available feature in DC only. () Certified IEC 6508 Functional Safety data, use suffix "SL". 4-4-9 80054GB-0/R0
SERIES 55 PREFIX TABLE power level description 4 5 6 7 UP LP RP BP C F S C Solenoid + spade plug AMP,5x0,5, 9,4 mm, (EN 6070), 0 pilot - - - C F V T Solenoid with M connection, LED + protection (EN 6070), 0 pilot - m - - C F S C I S Intrinsically safe, 9,4 mm, pilot 0; ATEX (EN/IEC 60079-/6)* - m - - P I S C Solenoid with spade plug connector (EN 6070), 60 piezotronic pilot - - - P I S C I S Intrinsically safe, piezotronic 60 pilot, ATEX (EN/IEC 60079-/6079-6) * m - - - SUFFIX TABLE suffix power level description 4 5 6 7 UP LP RP BP G D Non-electrical, GD c, construction safety, gas/dust (EN 46-5) - - - - M S Screw type manual operator () - / - - M O Push type manual operator / / - - S L Certified IEC 6508 Functional Safety data / / - - OPTIONS & ACCESSORIES series exhaust pipe protector (stainless steel) G /4 460049 () 55 NPT /4 460048 () M5 4600484 () Available feature m Available feature in DC only - Not available * ATEX solenoids are also approved according to EN 46- (non electrical valves) () Not to use with "SL" suffix () Provided with "SL" suffix PRODUCT SELECTION GUIDE STEP Select the fluid temperature range and seal material from the general table on page 9. Select basic catalogue number, including pipe thread identification letter. Refer to the specifications tables on page 9. Example: G55C507 STEP Select (combination). Select the appropriate operator from the tables on pages 9 and 0. Select for this operator in the electrical characteristics table on page : the power level (UP, LP), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. Example : CFSC STEP Select suffix. Suffix MO mandatory for the pilot 0 (CFSCIS). Refer to the suffix table on page 0, respect the indicated power level. Example : MO STEP 4 Selection of TPL, on page, is mandatory for the 60 pilot (PISCIS), HV DC ( mw) and 4 HV DC (5 mw). Add "X" between the "PISCIS" and the basic catalogue number. STEP 5 Select voltage. Refer to standard voltages on page. Example : 0V / 50Hz STEP 6 Final catalogue / ordering number. Example : ORDERING EXAMPLES: CFSC G55C507MO 0 V / 50 Hz CFSC G 55 C 507 0V / 50 Hz CFSC G 55 C 507 SL 0V / 50 Hz CFVT 8 55 C 508 MO 0V / 50 Hz PISCIS G 55 C 507 MO 6V / DC PISCIS G 55 C 507 SLMO 6V / DC PISCIS X G 55 C 508 MS TPL0666 4HV / DC G 55 A 07 G 55 A 07 GD G 55 A 07 GDSL G 55 A 08 pipe thread basic number voltage TPL suffix 4-4-0 80054GB-04/R0
EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVES Valve temperature range Operator ambient temperature range Total temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) The operator ambient temperature range is determined by the selected power level and the safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above ELECTRICAL CHARACTERISTICS Coil insulation class F Electrical safety IEC 5 Standard voltages DC () CFSC/CFVT: 4V CFSCIS: V - 4V ; PISC: 4V à 70V ; PISCIS: 6V, 8V, V, 4V AC (~) CFSC: 4V - 5V - 0V/50Hz - Other voltages are available on request PISC: 4V to 70V power ratings operator electrical ambient replacement coil inrush holding hot/cold temperature enclosure safety code option range (TS) protection type ~ ~ ~ () (VA) (VA) (W) (W) (C ) (EN 6059) - - Low power (LP) CFSC,4,, /, -5 to +60 EN 6070 moulded IP65 - - 0 CFSC, (6),6 (6),5 (6) - -5 to +60 EN 6070 moulded IP65 - - 0 CFVT (5) - - -,5/,5-5 to +60 EN 6070 moulded IP67/IP65 - - 0 CFSCIS ()(4) - - - 0,5-0 to +40/60 II G Ex ia IIC T6/T4 Ga, II D Ex ia IIIC Da moulded IP65 - - 04 Ultra low power (UP) PISC - - - 0,007-0 to +60 - moulded IP65 - - 06 PISCIS ()() 6V - - - 0,00-0 to +50 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP65 - - 06 PISCIS ()() 8V - - - 0,0-0 to +50 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP65 - - 06 PISCIS ()() LV - - - 0,0-0 to +50 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP65 - - 06 PISCIS ()() HV - - - 0,0-0 to +50 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP65 - - 06 PISCIS ()() LV - - - 0,046-0 to +50 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP65 - - 06 PISCIS ()() HV - - - 0,5-0 to +50 II G Ex ia IIC T6 Ga, II D Ex ia IIIC Da moulded IP65 - - 06 - Not available () Refer to the dimensional drawings on pages and. () Piezotronic standards voltages: Prefix PISCIS: 6 V DC / mw 8 V DC / mw L V DC / mw H V DC / mw 4L V DC / 46 mw 4H V DC / 5 mw Turn ON voltage U ON 6.. 9 V 7,.. V 0,8.. 6 V 0,8.. 6 V,6.. 8 V,6.. 8 V Turn OFF voltage U OFF V, V, V, V 5 V 5 V Peak current 6 ma 0 ma 6,8 ma 8, ma 0 ma 4 ma Holding current 0,5 ma,8 ma ma,7 ma,9 ma 5, ma Cable + max. barrier resistances (R S + R C ) 00 Ω max. 00 Ω max. 00 Ω max. 470 Ω max. 00 Ω max. 470 Ω max. safety parameters () Intrinsically safe pilots: Check the electrical characteristics in the corresponding catalogue pages (CFSCIS: option U I I I P I L I C I (DC) (V) (ma) (W) (H) (µf) Low power (LP) CFSCIS 8 00,6 0 0 Ultra low power (UP) PISCIS 0 00 0,9 0 0 0 pilot / PISCIS: 60 pilot). (4) CFSCIS (0 pilot): V : I (ON) min., with LED ma; U (ON) min.,9 V; U (max.) recommended V; U (OFF), V; I (OFF) 0 ma 4 V : I (ON) min., with LED 5 ma; U (ON) min. 6,4 V; U (max.) recommended 8 V; U (OFF) 5,7 V; I (OFF) 7 ma (5) Values for LED + protection. (6) AC: 0 V - Not available ELECTRICAL CONNECTIONS connection Spade plug connector with cable gland DIN 4650, 9,4 mm, industry standard B, for cables with an outer diameter CFSC, CFSCIS, PISC, PISCIS from 4 to 6 mm CFVT M connection for M connector ADDITIONAL OPTIONS TPL numbers: TPL 0665: Piezotronic, PISCIS, HV ( mw) TPL 0666: Piezotronic, PISCIS, 4 HV (5 mw) TPL numbers: TPL 0674: LED and protection, CFSC - Add 0,5 W (DC) and 0,4 W/VA (AC) Only available in 4 V AC/DC and 5 V AC Mounting on aluminium supply rail, /4 or / Other pipe threads are available on request SERIES 55 INSTALLATION Installation/maintenance instructions are included with each valve The solenoid valves and air operated valves can be mounted in any position without affecting operation Do not connect the pressure supply to the exhaust port. The "environmentally-protected" construction is not adapted for a "distributing" function IEC 6508 Functional Safety (suffix SL), allowable temperature range: -40 C to +60 C Check temperature range of valve body and solenoid for suitability. For probability of failure, contact us It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifier is: 8 NPT (ANSI.0.); G G (ISO 8/) Valves with suffix "SL" are provided with a specific exhaust protector 4-4- 80054GB-04/R0
SERIES 55 DIMENSIONS (mm), WEIGHT (kg) Type 0..06: CNOMO 5 (E06.6.0N) Type 07: Air operated 48,5,9 A 45 G/8 50.5 x G/4 7,5 49,4 x G/4,8,55 0 45 09,5 8 7,5 A mounting holes 5. mm dia.; Spotfacing: 9 mm dia., depth 5 mm 9,5,5 A 6 TYPE 0: CFSC 0 pilot Polyarylamide IEC 5 / DIN 4650 TYPE 0: CFVT 0 pilot Polyarylamide IEC 5 / connection M + LED and protection 55C507 / 55C508 55C507MS / 55C508MS / 55C507MO / 55C508MO 55C507 / 55C508 55C507MS / 55C508MS / 55C507MO / 55C508MO 60 75 49,5 54 M5 M5 50 60 9 TYPE 04: CFSCIS 0 pilot Polyarylamide IEC 5 / DIN 4650 EN/IEC 60079-/6 09 TYPE 06: PISC / PISCIS Piezotronic pilot Polyamide IEC 5 / DIN 4650 EN 60079-/6 55C507MO / 55C508MO 55C507MO / 55C508MO 49 5 60 75 M5 60 M5 60 9 9 4-4- 80054GB-0/R0
SERIES 55 DIMENSIONS (mm), WEIGHT (kg) TYPE 07: Air operated version No Use "SL", "GD" or "GDSL" suffix IP65 / II GD c 55A07 / 55A08 45 7,5 Connector rotatable by 90 increments (cable 4-6 mm) Connector rotatable by 90 increments (cable 6-7 mm) Manual operator location Connectable pilot exhaust port type option power level weight () monostable bistable 0 CFSC low power 0,88,09 0 CFVT low power 0,88,09 04 CFSCIS low power 0,888,0 06 PISC / PISCIS ultra low power 0,867,059 07 - - 0,8 0,987 () Incl. connector(s), except CFVT. ACCESSORIES B ØA ØA M5 - /4 B 4, - exhaust protector (stainless steel) 80054GB-0/R0 4-4-
SERIES 55 4-4-4 PIC-04-004-GB -- Availability, design and specifications are subject to change without notice. All rights reserved. 80054GB-0/R0