CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Similar documents
Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

RCBA- MULTIFLEX INDOOR COILS

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

FORM NO. HSC-543 AIR HANDLERS

Rheem High Efficiency Air Handler

Ruud High Efficiency Air Handler

INSTALLATION INSTRUCTIONS

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

AIR CONDITIONERS WA14**A SERIES

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

UPFLOW/ HORIZONTAL GAS FURNACE

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

Rheem High Efficiency Air Handler

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

AIR CONDITIONERS WA16 SERIES

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

14.5 SEER VALUE SERIES CONDENSING UNITS

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

13 SEER CONDENSING UNITS

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Modular Variable Speed Air Handlers

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

ELITE SERIES R-410A Ready - Multi-Position

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

Table of Contents GF801U Series

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)


Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Dual-Refrigerant Coils

FMU4X, FMC4X FMU4Z, FMC4Z

CAPF, CAUF, CHPF, & CSCF DUAL-REFRIGERANT SERIES

TECHNICAL SPECIFICATIONS

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

TECHNICAL SPECIFICATIONS

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

ELECTRIC HEAT AIR HANDLERS

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

Rheem Classic Series Upflow/Horizontal Gas Furnace

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

HE Series Evaporator Coils

HE Series Evaporator Coils

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

ELITE Series R-410A - Upflow / Horizontal

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

Indoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

Indoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

INDOOR COOLING COILS FOR DUAL FURNACE APPLICATION

Indoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

EVAPORATOR COILS PRODUCT SPECIFICATIONS EAC4X EAC1P EAU1P EAH1P EVAPORATOR COILS FEATURES

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: MC, PC, FC, HD, UC CFM 1.

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)

Product Data. Convertible Air Handlers 1 1/2 5 Ton D-EN. September 2016

HEAT PUMPS UPLB- SERIES. Seven Models

FEM4P, FSM4P, FSU4P. Product Specifications

Package Air Conditioners

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Transcription:

FORM NO. CFJ-224 Supersedes Form No. PTZ-789 CASED/UNCASED COILS FOR GAS AND OIL FURNACES FCC SERIES featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering Device Shown) Manufactured for Fujitsu General America, Inc. Fairfield, NJ Features Fujitsu Indoor Furnace cased coils and replacement uncased coils are designed for use with Fujitsu outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Fujitsu outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kw] to 60,000 BTU/HR [17.6 kw]. Constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Feature two sets of 3 /4" [14.1 mm] N.P.T. Condensate drain connections for ease of connection. Chatleff metering device connections, at inlet and outlet of TXV or EEV and equalizer connections (TXV only). Approved for system application with variety of Fujitsu outdoor units. Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material. Compatible with Germicidal Light System (UV resistant) Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right. Unique drain pan design maximizes application flexibility and condensate removal. N-Coil design maximizes performance and minimizes height required at installation. Coils are AHRI certified for system application with a variety of Fujitsu outdoor units.

Table of Contents TABLE OF CONTENTS Model Number Identification...3 Available SKUs...3 Coil Specifications...4-5 Coil Dimensions and Weights...6-7 Accessories...8-9 Limited Warranty...10 2 Fujitsu General America, Inc.

Model Number Identification/Available SKUs Model Number Identification FC C 24 14 T S A Product Case Capacity Width Device Efficiency Coil Shape Coil C = Cased 24 = 24,000 [7.04 kw] 36 = 36,000 [10.55 kw] 48 = 48,000 [14.07 kw] 60 = 60,000 [17.58 kw] 14" 17" 21" 24" T = TEV S = Standard M = Medium H = High A = N Coil TXV MODELS AVAILABLE FCC2414TSA FCC4824TSA FCC2417TSA FCC6021TSA FCC2417TMA FCC6024TSA FCC2421TMA FCC2417THA FCC3617TSA FCC2421THA FCC3621TSA FCC3621THA FCC3621TMA FCC3624THA FCC3624TMA FCC4824THA FCC4821TSA FCC6024THA FCC4821TMA Fujitsu General America, Inc. 3

Coil Specifications Table 1: Coil Specifications/Airflow Pressure Drop Coil Model (-)CF FCC2414TSA FCC2417TSA FCC2417TMA FCC3617TSA FCC2421TMA FCC2421THA FCC3621TSA FCC3621TMA FCC3621THA FCC4821TMA FCC4821TSA FCC6021TSA FCC3624TMA FCC3624THA FCC4824TSA FCC4824THA FCC6024TSA FCC6024THA Approx. Design Cooling Air Flow Range CFM [L/s] 600/900 [283/425] 600/900 [283/425] 600/900 [283/425] 700/1300 [330/614] 600/900 [283/425] 600/900 [283/425] 700/1300 [330/614] 700/1300 [330/614] 700/1300 [330/614] 1100/1800 [519/850] 1100/1800 [519/850] 1400/1600 [661/755] 700/1300 [330/614] 700/1300 [330/614] 1100/1800 [519/850] 1100/1800 [519/850] 1400/1800 [661/755] 1400/1800 [661/755] Face Area Sq. Ft. [m 2 ] 4.56 [0.42] 4.56 [0.42] [.052] 7.60 [0.70] 7.60 [0.70] 7.60 [0.70] Fins Per Inch / Rows Deep Width 14 Nominal Capacity 1.5 2 600 [283] 700 [330] Wet Coil Static Pressure Drop (Inches W.C.) [kpa] @ CFM [L/s] (Coil Only) 800 [378] 900 [425] 1000 [472] 1100 [519] 1200 [566] 1300 [614] 1400 [661] 1500 [708] 1600 [755] 1700 [802] 1800 [850] 0.165 0.209 0.262 0.325 0.120 0.157 0.199 0.246 17 0.113 0.145 0.181 0.222 2.5 3 0.113 0.145 0.181 0.222 0.266 0.315 0.368 0.113 0.145 0.181 0.222 1.5 2 0.113 0.145 0.181 0.222 0.113 0.145 0.181 0.222 0.266 0.315 0.368 2.5 3 0.062 0.086 0.112 0.140 0.170 0.202 0.236 21 13/3 0.106 0.125 0.146 0.169 0.194 0.221 0.251 13/3 0.106 0.125 0.146 0.169 0.194 0.221 0.251 0.282 0.315 0.350 0.386 0.425 0.466 3.5 4 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 0.349 0.391 0.434 0.480 0.527 13/3 5 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 2.5 3 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 0.349 0.391 0.434 0.480 24 3.5 4 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 5 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 Important Note: Gas furnace heating CFM can exceed the design cooling CFM. Ductwork and coil selection must accommodate the higher of the cooling or gas heating CFM to prevent furnace limit tripping, excessive noise, and coil freeze-up. 1900 [897] 4 Fujitsu General America, Inc.

Coil Specifications Table 1: Coil Specifications/Airflow Pressure Drop (con t.) Coil Model (-)CF FCC2414TSA FCC2417TSA FCC2417TMA FCC3617TSA FCC2421TMA FCC2422THA FCC3621TSA FCC3621TMA FCC3621THA FCC4821TMA FCC4821TSA FCC6021TSA FCC3624TMA FCC3624THA FCC4824TSA FCC4824THA FCC6024TSA FCC6024THA Approx. Design Heating Air Flow Range CFM [L/s] 600/1600 [283/755] 600/1500 [283/707] 600/1600 [283/755] 600/1600 [283/755] 600/1600 [283/755] 600/1600 [283/755] 600/1600 [283/755] Face Area Sq. Ft. [m 2 ] 4.56 [0.42] 4.56 [0.42] [.052] 7.60 [0.70] 7.60 [0.70] 7.60 [0.70] Fins Per Inch / Rows Deep Width 14 Nominal Capacity 1.5 2 600 [283] 700 [330] Dry Coil Static Pressure Drop (Inches W.C.) [kpa] @ CFM [L/s] (Coil-Only) 800 [378] 900 [425] 1000 [472] 1100 [519] 1200 [566] 1300 [614] 1400 [661] 1500 [708] 1600 [755] 1700 [802] 1800 [850] 0.118 0.118 0.145 0.176 0.210 0.247 0.288 0.332 0.379 0.429 0.483 0.116 0.116 0.151 0.190 0.235 0.284 0.338 0.397 0.461 0.530 17 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 2.5 3 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 1.5 2 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 2.5 3 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 21 13/3 0.043 0.043 0.053 0.066 0.080 0.096 0.115 0.135 0.158 0.182 0.208 0.237 0.267 0.299 13/3 0.043 0.043 0.053 0.066 0.080 0.096 0.115 0.135 0.158 0.182 0.208 0.237 0.267 0.299 3.5 4 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 13/3 5 0.080 0.080 0.092 0.106 0.121 0.136 0.153 0.171 0.190 0.211 0.232 0.254 0.278 0.302 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 2.5 3 14/3 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 24 3.5 4 14/3 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 14/3 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 5 14/3 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 Important Note: Gas furnace heating CFM can exceed the design cooling CFM. Ductwork and coil selection must accommodate the higher of the cooling or gas heating CFM to prevent furnace limit tripping, excessive noise, and coil freeze-up. 1900 [897] Fujitsu General America, Inc. 5

Coil Dimensions and Weights Table 2: Coil Dimensions and Weights Coil Model FCC FIGURE 1: DIMENSIONS UNCASED Connections Sweat (in.) [mm] Liquid Suction I.D. I.D. Uncased Coil Dimensions (in) [mm] A B Coil Weight (lbs.) [Kg.] Weight Shipping Weight (lbs.) [Kg.] 2414TS 3/8 [9.53] 3/4 [19.05] 21 3 /4 88[552] 12 7 /8 [327] 43 [19] 47 [21] 2417TS 3/8 [9.53] 3/4 [19.05] 15 3 /8 88[390] 16 3 /8 [416] 43 [19] 48 [22] 2417TM, 2417TH, 3617TS 3/8 [9.53] 3/4 [19.05] 18 3 /4 88[476] 16 3 /8 [416] 49 [22] 54 [24] 2421TM, 2421TH, 3621TS 3/8 [9.53] 3/4 [19.05] 18 3 /4 88[476] 19 7 /8 [505] 51 [23] 60 [27] 3621TM, 4821TS 3/8 [9.53] 3/4 [19.05] 26 5 /8 88[676] 19 7 /8 [505] 71 [32] 78 [35] 3621TH, 4821TM, 6021TS 3/8 [9.53] 7/8 [22.23] 33 5 /888[838] 19 7 /8 [505] 76 [34] 86 [39] 3624TM, 4842TS 3/8 [9.53] 3/4 [19.05] 26 11 /16 [678] 23 3 /8 [594] 83 [37] 93 [42] 3624TH, 4824TH, 6024TS, 6024TH 3/8 [9.53] 3/4 [19.05] 30 15 /16 [786] 23 3 /8 [594] 100 [45] 108 [48] *The 14 inch, 2 ton RCF coil (2414) is part of the N-Coil design series, even though the coil shape resembles an A coil design. (EEV SHOWN) (TXV SHOWN) FRONT VIEW SIDE VIEW 1 5 /16 [33.3 mm] SUCTION TUBE 7/16 [11.1 mm] 5 3 /8 [137 mm] 3 9 /16 [90.4 mm] 1/8 [3.1 mm] 4 11 /16 [119 mm] 1 13 /16 [46 mm] 1 11 /16 [42.8 mm] (TXV SHOWN) 11/16 [17.4 mm] LIQUID TUBE 21 3 /8 [543 mm] 6 Fujitsu General America, Inc.

Coil Dimensions and Weights Table 2: Coil Dimensions and Weights Coil Model RCF Connections Sweat (in.) [mm] Liquid Suction I.D. I.D. Cased Coil Dimensions (in) [mm] A B C Coil Weight (lbs.) [Kg.] Weight Shipping Weight (lbs.) [Kg.] 2414TS 3/8 [9.53] 3/4 [19.05] 14 1 /2[356] 21 1 /2[533] 23 3 /16 [584] 43 [19] 47 [21] 2417TS 3/8 [9.53] 3/4 [19.05] 17 1 /2 [445] 14 1 /2 [368] 20 1 /2 [508] 43 [19] 48 [22] 2417TM, 2417TH, 3617TS 3/8 [9.53] 3/4 [19.05] 17 1 /2 [445] 17 7 /8 [454] 20 1 /2 [508] 49 [22] 54 [24] 2421TM, 2421TH, 3621TS 3/8 [9.53] 3/4 [19.05] 21 1 /2[533] 17 1 /2 [445] 20 1 /2 [508] 51 [23] 60 [27] 3621TM, 4821TS 3/8 [9.53] 3/4 [19.05] 21 1 /2[533] 25 7 /8 [657] 28 7 /8 [711] 71 [32] 78 [35] 3621TH, 4821TM, 6021TS 3/8 [9.53] 7/8 [22.23] 21 1 /2[533] 32 7 /8 [813] 34 1 /2 [876] 76 [34] 86 [39] 3624TM, 4842TS 3/8 [9.53] 3/4 [19.05] 24 1 /2 [622] 25 3 /8 [645] 32 1 /2 [812] 83 [37] 93 [42] 3624TH, 4824TH, 6024TS, 6024TH 3/8 [9.53] 3/4 [19.05] 24 1 /2 [622] 30 1 /4 [768] 32 1 /2 [812] 100 [45] 108 [48] *The 14 inch, 2 ton RCF coil (2414) is part of the N-Coil design series, even though the coil shape resembles an A coil design. FIGURE 1: DIMENSIONS CASED PLENUM WIDTH 19 7 /8 [505 mm] A MINUS ONE INCH ➀ FRONT VIEW SIDE VIEW NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION 1/2 [12.7 mm] 7/16 [11.1 mm] SUCTION LINE LIQUID LINE 1 7 /16 [36.5 mm] 5 15 /16 [150.8 mm] 4 1 /8 [104.7 mm] 5 3 /8 [136.5 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL & HORIZONTAL) 1 13 /16 [46 mm] 2 1 /4 [57.1 mm] SECONDARY DRAIN 3/4 N.P.T. (VERTICAL) 1 1 /4 [31.7 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL) 21 11 /16 [550.8 mm] ➀ Casing top and bottom openings are the same dimensions. Fujitsu General America, Inc. 7

Accessories Table 3: Coil Application Coils can be matched to heating products as listed in table below. Coil Model FCC 2414TS 2417TS 2417TH/2417TM 3617TS 2417TS 2417MT/2417TM 3617TS 2421TM/2421TH 3621TS 3621TM/4821TS6021TS 3624TM/3624TH 4824TS/4824TH 6024TS/6024TH Oil Gas 14 [356] 17 1 /2 [431] 21 [533] 24 1 /2 [622] Furnace Width (In.) (mm) 17 1 /2 [444] 14 [356] 21 [533] 17 1 /2 [444] 24 1 /2 [622] 21 [533] Accessories PLENUM ADAPTER ACCESSORY RXBA-AE This plenum adapter accessory is for use with the 24 1 /2" wide cased indoor cooling and heat pump coils. This allows a 24 1 /2" wide cased coil to be installed on a 28" wide oil furnace. This is a field-installed accessory only. RXBA-AC (Upflow/Horizontal) These plenum adapter accessories are for use when a cooling coil is matched with a gas furnace of one smaller size. HORIZONTAL ADAPTER KIT RXHH (See Figure 2) This horizontal adapter kit is used to convert a upflow or downflow coil for a horizontal application. See Table 4 to order the proper horizontal adapter kit. Table 4: Horizontal Adapter Kit Model No. Coil Model 2414TS 2417TS 2417TM/2421TM/3617TS/ 3621TS/2421TH 3621TM/3624TM/ 4821TS/4824TS 3624TH/4824TH/ 6024TS/6024TH 3621TH/4821TM/6021TS Horizontal Adapter Kit Model No. RXHH-A01 RXHH-A02 RXHH-A03 RXHH-A04 RXHH-A05 RXHH-A06 FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION INDOOR COIL CASING- RXBC (See Table 5) R X B C D 14 I INSULATION I = Insulated Blank = Uninsulated CABINET WIDTH 14 = 14" [356 mm] 17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm] DESIGN SERIES COIL CASING BLOWER UNIT ACCESSORY Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings Model Number Width (in.) [mm] Height (in.) [mm] RXBC-D14AI 14 [356] 23 3 /16 [589] Depth (in.) [mm] Weight (lbs.) [Kg.] Unit Weight Ship. Wt. (lbs.) [Kg.] Supply Air/Return Air Openings Width (in.) [mm] 19 [9] 23 [10] 13 [330] RXBC-D17AI 17 1 /2 [445] 20 [508] 18 [8] 23 [10] 16 1 /2 [419] RXBC-D21AI 21 [533] 20 [508] 21 5 /8 [549] 20 [9] 26 [12] 20 [508] RXBC-D21BI 21 [533] 28 [711] 27 [12] 36 [17] 20 [508] RXBC-D24AI 24 1 /2 [622] 32 1 /2 [826] 34 [16] 44 [20] 23 1 /2 [597] Depth (in.) [mm] 19 31 /32 [508] AIR FLOW HORIZONTAL-DUAL DIRECTION Table 6: Uncased Coil Adapter Kit Uncased Coil Adapter Model Number RXBA A Width (in.) [mm] Uncased Coil Model RCFP B14x20 13 1 /8 [333] -HUxx14 B17x20 16 5 /8 [422] -HUxx17 B21x20 20 1 /8 [511] -HUxx21 B24x20 23 5 /8 [599] -HUxx24 HORIZONTAL ADAPTER KIT (RXHH-) 8 Fujitsu General America, Inc.

Accessories Accessories (cont.) UNCASED COIL ADAPTER KIT RXBA- (See Figure 3 & 4) This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters. FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED 1 1 /2 [41 mm] 7 11 /16 [196 mm] A 20 5 /16 [516 mm] Note: Sliding the coil into the coil rail before attaching coil rack front. R-22 TXV Conversion Kits To be used to convert R410-A coil to operate with R-22 FURNACE COIL CROSS REFERENCE CHART ORIGINAL COIL RECOMMENDED ALUMINUM TUBE REPLACEMENT COIL R-22 TXV CONVERSION KIT MODEL NO. FCCA-**2414 FCC2414TSA RXCT-HBA FCCA-**2417 FCC2417TSA RXCT-HBA FCCA-**3617 FCC3617TSA, FCC2417TMA, or FCC2417THA RXCT-HBB FCCA-**3621 FCC3621TSA, FCC2417TMA, or FCC2421THA RXCT-HBB FCCA-**4821 FCC4821TSA or FCC3621TMA RXCT-HBC FCCA-**4824 FCC4824TSA or FCC3624TMA RXCT-HBC FCCA-**6024 FCC6024TSA, FCC6024THA, FCC4824THA, or FCC3624THA RXCT-HBD **= AU, HM, or HU Fujitsu General America, Inc. 9

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Fujitsu General America, Inc. will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts...Ten (10) Years 10 Fujitsu General America, Inc.

Notes Fujitsu General America, Inc. 11

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. In keeping with its policy of continuous progress and product improvement, the right is reserved to make changes without notice. PRINTED IN U.S.A. 3-17 QG FORM NO. CFJ-224 Supersedes Form No. ATZ-204