THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT

Similar documents
Dispenser Pan Sensors & Containment Sump Sensors

Manual No: Revision: F. Mag Probe Assembly Manual

Dispenser Pan Sensors & Containment Sump Sensors

Manual No: Revision: B. CCVP Rain Shield. Installation Guide

Installation Manual Stand-Alone Dispenser Pan Sensor

Model C230 Pump Controller

Manual No: Revision: V PLLD. Site Prep and Installation Guide

RIGID ENTRY BOOT INSTALLATION GUIDE

Updated: October 2012

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Installation. Introduction

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

FADE Series Wall Axial Fans

PMP Replacement For Gilbarco Monochrome QVGA Display

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

ELB ELB

Manual No: Revision: J. FXV Leak Detectors. Installation Instructions

STP-MLD. Installation and Owner s Manual

Spray Nozzle Adapters

PRG 350 Series Stainless Steel Regulators

SUNC3000 / Item #40885

ANTI-SYPHON VALVE INSTALLATION GUIDE

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Air Curtain. Installation, Operating and Maintenance Instructions

Automatic Emergency Light

SEALING DIP CAP INSTALLATION GUIDE

SMART CONTROLLER I INSTALLATION GUIDE

Frekote Adjustable Spray Applicator 6 Extension Extension Extension EQUIPMENT Operation Manual

Installation and Operation Manual for VMAC Accessory A / A Air Receiver Tanks

PRG 350 Series Stainless Steel Regulators

LPG Premier 21-Stage Pump Section LPG Premier MidFlow 17-Stage Pump Section LPG Premier HiFlow 24-Stage Pump Section

Owner s Manual & Safety Instructions

Effective June 1, 2013 This guide supersedes all previous versions

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.

AEROMOTIVE Part # / L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Please note: upgrades from older fluorescent backlit displays (Q ) will require PMP Adapter Kit #62071 or equivalent

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

ADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Owner s Manual & Safety Instructions

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Galaxy Receiving and Unpacking 09/

Old Proportioning Pumps

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

CHEVY YUKON, SUBURBAN, TAHOE INSTALLATION INSTRUCTIONS KIT SUM

Applies to: Models F, B, FE, and BE with spark pilot

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

HP190SL Series Slimline Radon Fans

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Gauge Adapter Instruction Manual

Manual Operated Floor Jack

Legacy Combustion Chamber Replacement Kit

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

15H882 Slider Bearing Kit

CHEVY TRUCK INSTALLATION INSTRUCTIONS KIT SUM

User Guide IGD Series

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

Viscount I Hydraulic Motor and Displacement Pump

Owner s Manual & Safety Instructions

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

SB SWITCH CONTROL BOX

FLEX-ING TM DISPENSER HOSES INSTALLATION GUIDE

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

Pressurized oil drain for collection of used lubricants and anti-freeze.

# and # FAST Fuel System Kits

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

NUTONE RANGE HOOD NTM SERIES

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Introduction. Caution. This manual provides installation instructions for installing the Atlas Discharge and Valve Conduit Retrofit Kit.

Installation and Operation Manual

CONTENTS: 5740AH - 40 Ton Air/Hydraulic Shop Press 5750AH - 50 Ton Air/Hydraulic Shop Press OWNER'S MANUAL

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

DC400 Dispensing Cutoff System

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

Pro Shot Grease Dispense Valve

StormPro BA Series Sump Pump

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

HYDRAULIC SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: HS2000 = 4.8 LBS. (2.17 Kg) HS3000 = 22 LBS. (9.98 Kg)

Gas Conversion Kits and Instructions

IMPORTANT INFORMATION

Owner s Manual & Safety Instructions

Manifold w/ Needle Valve Instruction Manual

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Quick Connection Cabinet (QCC)

Purpose This document provides installation instructions for the Gasboy 9820 Pump Interface Kit.

Megohmmeter Test Probe

Clevis Plunger & Base Instruction Manual

CRD610 Automatic Fitting Inserter

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Installation and Operation

Transcription:

Replacement Instructions WPLLD Transducer Replacement Instructions Manual Number 577013-710, Revision A WARNING THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT IN FUEL SPRAYING DURING DISPENSER, PRODUCT LINE, LEAK DETECTOR OR STP SERVICE. PERFORM THE FOLLOWING BEFORE BEGINNING SERVICE: 1. CLOSE AFFECTED DISPENSER SHEAR VALVE AND TEST FOR PROPER SHUTOFF OF THE VALVE IF PERFORMING DISPENSER HYDRAULIC SERVICE. 2. REMOVE POWER TO THE SUBMERGED PUMP (STP) AND TO LLD-300 AND LINE LEAK DETECTOR SYSTEM. 3. WEAR EYE PROTECTION. 4. COLLECT FUEL APPROVED CONTAINERS. DO NOT CONTAMINATE ENVIRONMENT. TO ORDER TAGS - USE PART NO. 329801-00X VEEDER-ROOT Environmental Products

Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root. The information contained in this publication is subject to change without notice. Veeder-Root 1998. All rights reserved.

Contents Introduction Safety Symbols...1 Warnings and Important Notes...2 Damage Claims...2 Replacing The WPLLD Sensor Checking the Functional Element Orifice (For Red Jacket Pumps)...3 WPLLD Sensor Removal...4 WPLLD Sensor Installation...4 Checking STPs for leaks...6 i

Contents Figures Figure 1. Disabling the Functional Element... 4 Figure 2. Connecting WPLLD Sensor To Pump... 5 ii

Introduction This manual covers Transducer Replacement Instructions for Veeder-Root Wireless Pressurized Line Leak Detection (WPLLD) Systems. Safety Symbols The following safety symbols may be used throughout this manual to alert you to important safety hazards and precautions. Explosive Fuels and their vapors are extremely explosive if ignited. Flammable Fuels and their vapors are extremely flammable. Electricity High voltage exists in, and is supplied to, the device. A potential shock hazard exists. OFF Turn Power Off Live power to a device creates a potential shock hazard. Always turn power off to the device and associated accessories when servicing the unit. No Power Tools Sparks from power tools (such as drills) can ignite fuels and their vapors. Use Safety Barricades Unauthorized people or vehicles in the work area are dangerous. Always use safety cones or barricades, safety tape, and your vehicle to block the work area. Read All Related Manuals Knowledge of all related procedures before you begin work is important. Read and understand all manuals thoroughly. If you do not understand a procedure, ask someone who does. 1

Warnings and Important Notes Introduction Warnings and Important Notes WARNING This product is to be installed in systems operating near locations where highly combustible fuels or vapors may be present. Fire or explosion resulting in serious injury or death could result if the equipment is improperly installed or modified. Serious contamination of the environment may also occur. 1. Read and follow all instructions in this manual, including all safety warnings. 2. Comply with all applicable codes including: the National Electrical Code; federal, state, and local codes; and other applicable safety codes. 3. Do not alter or modify any component or substitute components in this kit. 4. Do not use this component for other systems aside from the WPLLD. Install console only as described in this manual. 5. The WPLLD must be installed and operated in an indoor location. Damage Claims 1. Thoroughly examine all components and units as soon as received. If damaged, write a complete and detailed description of the damage on the face of the freight bill. The carrier's agent must verify the inspection and sign the description. 2. Immediately notify the delivering carrier of damage or loss. This notification may be given either in person or by telephone. Written confirmation must be mailed within 48 hours. Railroads and motor carriers are reluctant to make adjustments for damaged merchandise unless inspected and reported promptly. 3. Risk of loss, or damage to merchandise remains with the buyer. It is the buyer's responsibility to file a claim with the carrier involved. 4. Immediately advise your Veeder-Root representative, distributor, or the factory so that we may assist you. 2

Replacing The WPLLD Sensor WARNING OFF This equipment uses lethal voltages and attaches to accessory components which operate in areas where flammable liquids and vapors may be present. Serious injury or death from shock, explosion, or fire may result if power is on during installation and the device is improperly installed. When installing this product: 1. Read and understand all instructions. 2. Turn OFF power to the console and submersible pumps during installation. 3. Use only Veeder-Root supplied service parts to avoid compromising safety. 4. Wiring must comply with all applicable requirements of the National Electrical Code; federal, state, and local codes; and any other safety codes. 5. To protect yourself and others from being struck by vehicles, block off your work area during installation or service. Checking the Functional Element Orifice (For Red Jacket Pumps) Important If you are using an FE Petro pump, skip this section. 1. Remove the six slot-head screws from the functional element [Figure 1 on page 4]. 2. Visually verify that the orifice is free from debris and that the spring has been removed. 3. Carefully reassemble the functional element. Be sure that all gasketed surfaces are free from debris when reinstalling. 3

Checking the Functional Element Orifice (For Red Jacket Pumps) Replacing The WPLLD Sensor slld\frms2rj.eps Remove spring/ piston assembly Rubber diaphragm Red Jacket Pump With Older Functional Element Figure 1. Disabling the Functional Element WARNING This system contains hazardous fuels. If the functional element leaks, serious injury or death from fire or explosion, or environmental contamination may result. When reinstalling: 1. Follow instructions completely. 2. Check for leaks after the system is pressurized. WPLLD Sensor Removal OFF 1. Ensure power to the STP is turned OFF. 2. Disconnect the sensing line from the WPLLD sensor. 3. Remove the capacitor cover bracket from the WPLLD sensor and set it (and pump capacitor cover) aside for reinstallation. 4. Unscrew the WPLLD sensor from the pump. 5. Remove the plastic shield from the capacitor housing and disconnect the sensor wires from the pump wires. 4

Replacing The WPLLD Sensor Checking the Functional Element Orifice (For Red Jacket Pumps) WPLLD Sensor Installation 1. Remove the protective plastic cap from the WPLLD sensor. 2. If the sensor is being installed at altitudes above 2,000 feet, open the vent screw at least two turns, but not more than three turns, to vent any internal pressure. (WPLLD sensors are equipped with a vent screw to equalize internal pressure.) 3. Retighten the vent screw securely to prevent water from entering. (Failure to release internal pressure in the WPLLD sensor at altitudes above 2,000 feet could cause inaccurate pressure readings and false line leak alarms.) O-ring from installation kit Wireless line leak sensor shown upside down and resting on pump slld\wscpwir.eps Vent screw - If you are installing this sensor above an altitude of 2000 feet you must loosen this screw (2-3 turns CCW) to release any internal pressure, and then retighten the screw. Cut the black wire from the power source to the capacitor and strip each end to expose 1/2-inch of bare wire. Twist the wire nut over the two ends of the black wire you just cut and stripped and the already stripped end of one of the black wires from the sensor. Red wire from motor to capacitor (Leave as is) Bleed resistor Motor capacitor shown removed from storage well Cut the orange wire (FE Petro pumps) or the yellow wire (Red Jacket pumps) running through the motor capacitor storage well and strip each end to expose 1/2-inch of bare wire. Twist the wire nut over the two ends of the colored wire you just cut and stripped and the already stripped end of one of the black wires from the Wireless Line Leak Sensor. Figure 2. Connecting WPLLD Sensor To Pump 5

Checking STPs for leaks Replacing The WPLLD Sensor 4. Follow the instructions in Figure 2 (above) to connect the WPLLD sensor to the pump. 5. Replace the shield into the capacitor housing with open side up. Hold the shield at an angle and place notched tab into the compartment first. Guide the two wires from the WPLLD sensor into the notch on the shield, leaving as much slack in the wires as possible above the shield (this will prevent stressing them when the WPLLD sensor is threaded into the pump). 6. Lightly lubricate the O-ring on the WPLLD sensor with mineral oil or other suitable lubricant. 7. Rotate the sensor about three turns counterclockwise, then screw the Wireless Line Leak Sensor into the pump compartment and tighten it securely. 8. Reconnect the sensing line to the WPLLD sensor and tighten it securely. 9. With the two 6-32 x 0.375 screws provided, attach the capacitor cover bracket (removed from the original WPLLD sensor) to the top of the new WPLLD sensor. Snap the capacitor cover into the bracket. Checking STPs for leaks OFF After connecting all of the sensors, apply power to each pump and check for leaks. Verify that the functional element, sensing lines, and check valve threads into each pump are not leaking. Product leakage can create serious environmental and safety hazards. Tighten any leaking fittings until the leak is stopped. Be careful not to overtighten and strip the threads. If the leak cannot be stopped, turn OFF power to the pump and check the fitting for thread damage or improper sealing. Replace or reseal the fitting(s) as required. 6

Sales Offices Veeder-Root has offices around the world to serve you. Headquarters Veeder-Root Company 125 Powder Forest Drive Simsbury, CT 06070-7684 U.S.A. (860) 651-2700 FAX: (860) 651-2719 England Veeder-Root Environmental Systems Limited Hydrex House, Garden Road Richmond, Surrey TW9 4NR ENGLAND 44-181-392-1355 Brazil Veeder-Root do BRASIL Rua ado Benatti, 92 Caixa Postal 8343 01051 Sao Paulo BRAZIL 55-11-861-2155 Germany Veeder-Root GmbH Uhlandstrasse 49 D-78554 Aldingen GERMANY 49 (0)7424 89285 France Veeder-Root SARL ZI des Mardelles 94-106 rue Blaise Pascal 93600 Aulnay-sous-Bois FRANCE 33 (0)1 4879 5599 Canada Veeder-Root Canada 151 Superior Boulevard, Suite 24 Mississauga, Ontario, L5T 2L1 CANADA 905-670-2755 Singapore Veeder-Root Singapore #2 Kallang Pudding Road #06-16 Mactech Industrial Building SINGAPORE 1334 (65) 745-0368 FAX: (65) 745-0636 Mexico Veeder-Root Mexico Prado de las Camelias No. 4483-4 Prados Tepeyac C.P. 45500 Zapopan, Jal., MEXICO (52) 36-47-3750 577013-710, Revision A VEEDER-ROOT Environmental Products