Grundfos Home Booster

Similar documents
GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

Company name: Created by: Phone:

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

MAGNA3 D x230V PN10

MAGNA3 D F 280 1x230V PN16

GRUNDFOS DATA BOOKLET. Self-priming. 50/60 Hz

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

MAGNA F 250 1x230V PN6/10

MAGNA F 340 1x230V PN6/10

MAGNA x230V PN10

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

MAGNA x230V PN10

MAGNA F 220 1x230V PN6/10

UPS F B 3x V PN6/10

CM5-5 A-R-A-E-AVBE C-A-A-N

GRUNDFOS DATA BOOKLET TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D. In-line circulator pumps. 50 Hz. Lenntech

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

UPS32-60 F B 1x V PN6/10

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

Lenntech GRUNDFOS DATA BOOKLET. CME 15. Horizontal, multistage centrifugal pumps 50/60 Hz

GRUNDFOS DATA BOOKLET. Fire CRFF. Grundfos fire systems. VdS-approved CR pumps for fire systems 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

SQ kW V 50/60Hz 70M

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

TPE 25-80/2-A-O-A-BUBE 1X230 50HZ

Grundfos pump

CM5-5 A-R-A-E-AVBE F-A-A-N

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

CM10-1 A-R-A-E-AQQE F-A-A-N

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CM5-6 A-R-A-E-AQQE C-A-A-N

SQ kW V 50/60Hz

CRE10-02 A-A-A-E-HQQE 1x HZ

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

CM1-2 A-R-A-E-AQQE F-A-A-N

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

TP /2-A-F-A-BUBE 1X230 50HZ

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete booster systems 50/60 Hz

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CM10-3 A-R-A-E-AVBE F-A-A-N

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

SP5A kW V 50Hz

CM3-6 A-R-G-E-AQQE C-A-A-N

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories. 50 Hz

TP /4-A-F-A-BUBE 400Y 50HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

TP 25-80/2-A-O-A-BQQE 400Y 50HZ

CRE15-01 A-F-A-E-HQQE 1x HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART COMPACT A 204 PERFORMANCE CHART COMPACT B 205

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403

SP3A kW 1x220V 50Hz

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

SE M.C.N.51D

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

TP 32-90/2-A-O-A-BQQE 400Y 50HZ

AGA-AGC. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

Hydro MPC-E 2CRIE L GNL

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HBQV 3x400/ HZ

Company name: Čerpadla NEPTUN Created by: Václav König Phone: Date:

NB /263 AS-F2-A-BAQE

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CR A-F-A-V-HQQV 3x400/ HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

Transcription:

GRUNDFOS DATA BOOKLET Grundfos Home Booster UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 5/6 Hz

Grundfos Home Booster Table of contents 1. Product description 3 Applications.................................................................................. 3 Type key.................................................................................... 3 Performance range............................................................................ 3 2. Operating conditions 4 Pumped liquids............................................................................... 4 Temperature................................................................................. 4 Pressure..................................................................................... 4 3. Construction 5 Sectional drawings UPA 15-9, UPA 15-12......................................................... 5 Sectional drawing UPA 15-16................................................................... 6 Sectional drawing UPA 12...................................................................... 7 Motor....................................................................................... 8 Rotor can.................................................................................... 8 Shaft with rotor................................................................................ 8 Thrust bearing................................................................................ 8 Bearing plate................................................................................. 8 Impeller..................................................................................... 8 Pump housing................................................................................ 8 Flow switch.................................................................................. 9 4. Installation 1 5. Performance curves 11 Curve conditions............................................................................. 11 6. Data sheets 12 7. Product numbers 28 8. Accessories 29 External flow switch for UPA 12................................................................. 29 9. Grundfos Product Center 3 2

Grundfos Home Booster 1 1. Product description UPA 15-9, UPA 15-12, UPA 15-16 and UPA 12 booster pumps increase the pressure of domestic water to make the required pressure available at showers, taps and other tapping points. A flow switch starts or stops the pump when a tapping point is turned on or off. UPA 15-9 and UPA 15-12 pumps have an integrated flow switch. UPA 12 and UPA 15-16 pumps are supplied with an external flow switch, which has to be placed after the outlet of the pump. The pumps are self-venting and do not require venting before start-up. All UPA pumps are supplied with a cable and plug. UPA booster pumps offer a host of advantages: Flexibility: Suitable for installation in existing systems. Comfort: Low-noise operation. User friendliness: Plug and play. Reliability: Proven Grundfos quality. Energy-efficiency: High-efficiency PM technology. UPA 15-16 consumes up to 87 % less electrical power than a conventional constant-speed booster. Corrosion-resistant: Cataphoresis-coated pump housing. Applications UPA booster pumps are designed for pressure boosting of domestic water supplied from an external source in residential homes. UPA booster pumps are used in open systems and can also be connected directly to the water main. Type key Example: UP A 15-9 N 16 Circulator pump Automatic start/stop Type range Maximum head Pump housing Cast iron N Stainless steel Port-to port length [mm] Product description Performance range TM6 228 4516 Fig. 1 Performance range UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 (23 V, 5 Hz) 3

2 Grundfos Home Booster Operating conditions 2. Operating conditions Pumped liquids UPA booster pumps are suitable for the these liquids: Fresh water Potable water without chemical additives Chlorinated potable water. UPA booster pumps are not suitable for the transfer of flammable liquids such as diesel oil and petrol. Temperature Standard pumps Max. [ C] Min. [ C] Liquid temperature 6/95/11 2 Ambient temperature 4 2 For liquid temperatures, please see also the Data sheets on page 11 and following. Pressure Operating pressure Maximum operating pressure Pump version [MPa] [bar] UPA 15-9.6 6 UPA 15-9 Netherlands UPA 15-9 Global 1. 1 UPA 15-12 1. 1 UPA 15-16 1. 1 UPA 12.6 6 UPA 12 Mexico 1. 1 For operating pressures, please see also the Data sheets on page 11 and following. Inlet pressure To avoid cavitation noise and risk of damage to the pump bearings, a minimum pressure of 2. m head/.2 bar is required at the pump suction port during operation. 4

Grundfos Home Booster 3 3. Construction UPA 15-9, UPA 15-12, UPA 15-16 and UPA 12 circulator pumps for pressure boosting are of the canned-rotor type, i.e. pump and motor form an integral unit without shaft seal. Only two gaskets are required for sealing. The bearings are lubricated by the pumped liquid. UPA 15-16: The motor is a high efficient 4-pole synchronous permanent-magnet motor. The pump controller is incorporated in the control box, which is fitted to the stator housing. Characteristic materials: Shaft: aluminium oxide or ceramic Radial bearing: ceramic Thrust bearing: carbon Rotor can and bearing plate: stainless steel Impeller: corrosion-resistant material Pump housing: cataphoresis-coated cast iron or stainless steel. Construction Sectional drawings UPA 15-9, UPA 15-12 8 13 1 2 5 11 1 13 8 1 2 11 5 1 5 17 2 17 18 2 18 7 14 7 14 6 15 6 15 3 16 3 16 12 5 5 5 19 9 TM6 2996 315 12 5 19 5 5 9 TM6 3444 315 Fig. 2 Sectional drawing of UPA 15-9 Fig. 3 Sectional drawing of UPA 15-12 Material specification UPA 15-9, UPA 15-12 Pos. Description Material Material number EN AISI Terminal box Composite PPE/PS 1 Terminal box cover Composite PPE/PS Electric unit Composite PET 2 Radial bearing Ceramic 3 Nameplate Composite PA66 Stator housing AlSi1Cu2 5 Stator winding cap Composite PET Stator windings Copper 6 Air vent screw Brass, nickelled, Ms58 2.41.3 7, 1 Gaskets EPDM rubber 8 Flow switch Magnet / EPDM rubber / PP 9 Rotor can Stainless steel 1.431 34 11 Shaft UPA 15-9: aluminium oxide UPA 15-12: ceramic 12 Thrust bearing Carbon Thrust bearing retainer EPDM rubber 13 Bearing plate Stainless steel 1.431 34 14 Ball (non-return valve) EPDM rubber 15 Split cone Stainless steel 1.431 34 16 Impeller UPA 15-9: composite PP 3 % GF UPA 15-12: composite PSP/PP 3 % GF 17 Neck ring Stainless steel 1.431 34 18 Pump housing UPA 15-9 and UPA 15-12: cast iron EN 1561 EN-GJL-15 ASTM 3 B UPA 15-9: stainless steel 1.438 34 C15 19 Stop ring Composite PES 2 Intermediate ring Stainless steel 5

3 Grundfos Home Booster Construction Sectional drawing UPA 15-16 8 1 5 5 13 1 16 18 14 15 17 3 2 6 19 9 12 5 11 5 5 TM4 9747 511 Fig. 4 Sectional drawing of UPA 15-16 Material specification UPA 15-16 Pos. Component Material Material number EN AISI Terminal box Composite 1 Terminal box cover Composite Heat sink with cooling pad AlSi11Cu2 EN461 2 Radial bearing Ceramic 3 Nameplate Composite PA66 5 Stator housing AlSi1Cu2 Stator windings Copper 6 Air vent screw Brass, nickelled, Ms58 2.41.3 O-ring EPDM ID234 8 Flow switch Magnet / EPDM rubber / PP 9 Rotor can Stainless steel 1.431/1.4521 34 1 Gasket EPDM rubber Stop ring PES 3 % GF 11 Shaft Ceramic Rotor cladding Stainless steel 1.431/1.4521 34 12 Thrust bearing Carbon Thrust bearing retainer EPDM rubber 13 Bearing plate Stainless steel 1.431 34 14 Ball (non-return valve) EPDM rubber 15 Split cone Stainless steel 1.431 34 16 Impeller Composite PES 3 % GF 17 Neck ring Stainless steel 1.431 34 18 Pump housing Cast iron EN 1561 EN-GJL-15 19 Stop ring Composite PES 6

Grundfos Home Booster 3 Sectional drawing UPA 12 13 1 2 11 1 Construction 17 18 14 15 2 7 6 3 16 12 5 19 9 TM3 1652 255 Fig. 5 Sectional drawing of UPA 12 Material specification UPA 12 Pos. Component Material Material number EN AISI Terminal box Composite PPE/PS 1 Terminal box cover Composite PPE/PS Electric unit (single-phase only) Composite PET 2 Radial bearing Ceramic 3 Nameplate Composite PA66 Stator housing AlSi1Cu2 5 Stator winding cap Composite PET Stator windings Copper 6 Air vent screw Brass, nickelled, Ms58 2.41.3 7, 1 Gaskets EPDM rubber 9 Rotor can Stainless steel 1.431/1.4521 34 11 Shaft, complete Ceramic 12 Thrust bearing Carbon Thrust bearing retainer EPDM rubber 13 Bearing plate Stainless steel 1.431 34 14 Ball (non-return valve) EPDM rubber 15 Split cone Stainless steel 1.431 34 16 Impeller Composite PSP/PP 3 % GF 17 Neck ring Stainless steel 1.431 34 18 Pump housing Cast iron EN 1561 EN-GJL-15 19 Stop ring Composite PES 2 Intermediate ring Stainless steel 1.431 34 7

3 Grundfos Home Booster Construction Motor UPA 15-9 and UPA 15-9 N UPA 15-9 and 15-9 N pumps have a 2-pole, asynchronous, squirrel-cage motor. The motor has a built-in impedance protection and is short-circuit-proof. No external motor protection is required. UPA 12 and UPA 15-12 UPA 12 and 15-12 pumps have a a 2-pole, asynchronous, squirrel-cage motor. The motor incorporates thermal overload protection. Therefore, no external motor protection is required. Pump housing UPA 15-9, UPA 15-12, UPA 15-16 (standard) The standard pump housing of UPA 15-9, UPA 15-12 and UPA 15-16 has a bore for a flow switch, and hydraulics have been adapted to the larger impeller. A stainless-steel ring equalises the dimensional difference between stator housing and pump housing. The standard pump housing is made of cataphoresiscoated cast iron. UPA 15-16 UPA 15-16 high-efficiency boosters are fitted with an electronically commutated motor (ECM) with permanent-magnet rotor and frequency converter. They are energy-optimised due to improved hydraulics and motor efficiency. Rotor can The rotor can is closed with an air vent screw fitted directly at the top. The upper radial bearing is incorporated in the top of the rotor can. Shaft with rotor The rotor is secured to the shaft with a pipe and an elastic sleeve. The rotor is totally encapsulated in a stainless-steel cladding. To avoid precipitation of calcium in the radial bearings, the shaft has been plunge-ground at the bearing entries. The shaft has a through-going hole to ensure perfect lubrication and cooling of the upper bearing. See sectional drawings. To prevent system water under pressure from running out when the air vent screw is removed, a non-return valve (rubber ball) is incorporated at the impeller end of the shaft. The air in the rotor chamber escapes out into the system through the hole in the shaft. Fig. 6 UPA 15-9, UPA 15-12, UPA 15-16 standard pump housing UPA 15-9 N (stainless steel) The pump housing of UPA 15-9 N is made of cast stainless-steel. UPA 12 (standard) The standard pump housing of UPA 12 is made of cataphoresis-coated cast iron. TM6 1411 2314 TM2 1327 91 Thrust bearing The thrust bearing is secured to the shaft by a spherically flexible suspension. Bearing plate The lower radial bearing is pressed into the bearing plate. Due to the relatively large surface of the bearing plate, the motor heat is carried away from the rotor can by the pumped liquid. Impeller The impeller is a radial impeller with curved composite blades. It is secured to the shaft by a split cone. Fig. 7 UPA 12 standard pump housing 8

Grundfos Home Booster 3 Flow switch UPA 15-9 The flow switch of UPA 15-9 consists of an arm with a magnet (1), that moves in a chamber (2). The chamber is separated from the pumped liquid and the terminal box. The magnetic field activates a magnetic contact (3). Construction 3 1 2 TM1 7251 4199 Fig. 8 UPA 15-9 flow switch in "OFF" position The pump selector can be set to the positions "OFF", "AUTO" and "MANUAL". Selector in positions Description I OFF The pump is switched off. II AUTO The pump starts and stops automatically (when the flow exceeds or falls below 9-12 l/h). III MANUAL* The pump runs continuously (even if tapping points are turned off). * When the selector is in position "MANUAL", at least one tap must be open. Otherwise the pumped liquid may become too hot. UPA 15-12 The flow switch of UPA 15-12 consists of an arm with a magnet (1), that moves in a chamber (2). The chamber is separated from the pumped liquid and the terminal box. The magnetic field activates a magnetic contact (3). 3 1 2 TM6 514 3315 Fig. 9 Flow switch of UPA 15-12 The UPA 15-12 doesn t contain an On/Off switch. 9

4 Grundfos Home Booster Installation 4. Installation The pump must always be installed with horizontal motor shaft. UPA 12, UPA 15-12 and UPA 15-16 pumps can be installed vertically or horizontally. The mounting position is limited by the length of the cable between the external flow switch and the terminal box. The terminal box of the UPA 15-9 has to be on the outlet of the pump, because of the integrated flow switch. Note: As the pumps have drain holes, the terminal box must not face downwards. TM6 2251 3814 Fig. 1 Installation directions 1

5 5. Performance curves Curve conditions The guidelines below apply to the performance curves on the following pages: Test liquid: airless water. The measurements for the UPA have been made at a water temperature of 2 C. All curves show average values and should not be used as guarantee curves. If a specific minimum performance is required, individual measurements must be made. The curves apply to a kinematic viscosity of = 1 mm 2 /s (1 cst). The conversion between head H [m] and pressure p [kpa] has been made for water with a density of ρ = 1 kg/m 3. For liquids with other densities, for example hot water, the discharge pressure is proportional to the density. Performance curves TM6 228 3914 Fig. 11 Comparison of curves: UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 (23 V, 5 Hz) 11

6 Data sheets 6. Data sheets UPA 15-9, 1 x 23 V, 5 Hz China, Argentina, Czech Republic, Turkey, Romania, Indonesia p [kpa] H [m] 75 6 45 3 15 8. 7. 6. 5. 4. 3. 2. 1....2.4.6.8 1. 1.2 1.4 1.6 Q [m³/h]..5.1.15.2.25.3.35.4.45 Q [l/s] TM1 6893 3699 Dimensions P1 max [W] I 1/1 [A] 12.48 Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +95 C (TF 95) G L1 L2 B1 B2 H1 H2 TM5 2534 212 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 12

6 UPA 15-9, 1 x 11 V, 6 Hz Brazil, Taiwan Data sheets p [kpa] 9 75 6 45 3 15 H [m] 9. 8. 7. 6. 5. 4. 3. 2. 1....2.4.6.8 1. 1.2 1.4 1.6 Q [m³/h]..5.1.15.2.25.3.35.4.45 Q [l/s] TM1 9635 23 Dimensions P1 max [W] I 1/1 [A] 12 1. Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +95 C (TF 95) G L1 L2 B1 B2 H1 H2 TM1 9639 23 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 13

6 Data sheets UPA 15-9 N, 1 x 24 V, 5 Hz Singapore, Australia, New Zealand p [kpa] 1 8 6 4 2 H [m] 1 8 6 4 2..2.4.6.8 1. 1.2 1.4 Q [m³/h]..1.2.3.4 Q [l/s] TM5 746 113 Dimensions P1 max [W] I 1/1 [A] 12.48 Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +95 C (TF 95) G L1 L2 B1 B2 H1 H2 TM1 6894 3699 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 14

6 UPA 15-9, 1 x 22 V, 6 Hz Brazil, Korea, Taiwan Data sheets p [kpa] 9 75 6 45 3 15 H [m] 9. 8. 7. 6. 5. 4. 3. 2. 1....2.4.6.8 1. 1.2 1.4 1.6 Q [m³/h]..5.1.15.2.25.3.35.4.45.5q [l/s] TM1 9636 23 Dimensions P1 max [W] I 1/1 [A] 12.48 Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +95 C (TF 95) G L1 L2 B1 B2 H1 H2 TM1 6894 3699 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 15

6 Data sheets UPA 15-9 N, 1 x 1 V, 6 Hz Japan p [kpa] 9 75 6 45 3 15 H [m] 9. 8. 7. 6. 5. 4. 3. 2. 1....2.4.6.8 1. 1.2 1.4 1.6 Q [m³/h]..5.1.15.2.25.3.35.4.45 Q [l/s] TM6 1927 3414 Dimensions P1 max [W] I 1/1 [A] 115 1.15 Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +6 C (TF 6) G L1 L2 B1 B2 H1 H2 TM1 9639 23 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 N 16 214 23 13 5 54 3/4" 2.5 2.7.42 16

6 UPA 15-9, 1 x 23 V, 5 Hz UK, India, Russia, Global Data sheets p [kpa] H [m] 75 6 45 3 15 8. 7. 6. 5. 4. 3. 2. 1....2.4.6.8 1. 1.2 1.4 1.6 Q [m³/h]..5.1.15.2.25.3.35.4.45 Q [l/s] TM1 6893 3699 Dimensions P1 max [W] I 1/1 [A] 12.48 Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar / Max. 1 bar (Global only) Liquid temperature: +2 C to +95 C (TF 95) G L1 L2 B1 B2 H1 H2 TM1 9639 23 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 17

6 Data sheets UPA 15-9 N, 1 x 23 V, 5 Hz Netherlands, UK p [kpa] H [m] 75 6 45 3 15 8. 7. 6. 5. 4. 3. 2. 1....2.4.6.8 1. 1.2 1.4 1.6 Q [m³/h]..5.1.15.2.25.3.35.4.45 Q [l/s] TM1 6893 3699 Dimensions P1 max [W] I 1/1 [A] 12.48 Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar / Max. 1 bar (Netherlands only) Liquid temperature: +2 C to +95 C (TF 95) G L1 L2 B1 B2 H1 H2 TM1 9639 23 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 18

6 UPA 15-9, 1 x 127 V, 6 Hz Mexico Data sheets p [kpa] 1 8 6 4 2 H [m] 1 8 6 4 2..2.4.6.8 1. 1.2 1.4 Q [m³/h]..1.2.3.4 Q [l/s] TM5 746 113 P1 max [W] I 1/1 [A] 12 1 G Enclosure class: IPX2D Connections: Rp 3/4 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +6 C (TF 6) L1 L2 B1 B2 H1 H2 TM1 9639 23 Dimensions [mm] L1 L2 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 15-9 16 214 23 13 5 54 3/4" 2.5 2.7.42 Net [kg] Gross [kg] 19

6 Data sheets UPA 15-12, 1 x 23 V, 5 Hz Europe TM6 252 3814 G P1 max [W] I 1/1 [A] 2.89 Enclosure class: IPX2D Connections: Rp 1 - Rp 1/2 unions Operating pressure: Max. 1 bar Liquid temperature: +2 C to +95 C (TF 95) L1 B1 B2 H1 H2 TM6 513 3315 Dimensions [mm] L1 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 15-12 2 2 13 63 69 1" 4.7 5..58 Net [kg] Gross [kg] 2

6 UPA 15-16, 1 x 23 V, 5 Hz Europe Data sheets TM6 7752 416 P1 max [W] I 1/1 [A] 18 1.41 Enclosure class: IPX2D Connections: Rp 1 - Rp 1/2 unions Operating pressure: Max. 1 bar Liquid temperature: +2 C to +95 C (TF 95) L1 L2 B1 B2 H1 H2 TM6 8119 4416 Dimensions [mm] L1 L2 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 15-16 13 23 25 11 116 5 1" 2.4 2.7.81 Net [kg] Gross [kg] 21

6 Data sheets UPA 15-12, 1 x 23 V, 5 Hz China TM6 252 3814 G P1 max [W] I 1/1 [A] 2.89 Enclosure class: IPX2D Connections: Rp 1- Rp 1/2 unions Operating pressure: Max. 1 bar Liquid temperature: +2 C to +95 C (TF 95) L1 B1 B2 H1 H2 TM6 513 3315 Dimensions [mm] Weights [kg] Shipping volume L1 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-12 2 2 13 63 69 1" 4.7 5..58 22

6 UPA 15-16, 1 x 23 V, 5 Hz China Data sheets TM6 7752 416 P1 max [W] I 1/1 [A] 18 1.41 Enclosure class: IPX2D Connections: Rp 1- Rp 1/2 unions Operating pressure: Max. 1 bar Liquid temperature: +2 C to +95 C (TF 95) L1 L2 B1 B2 H1 H2 TM6 8119 4416 Dimensions [mm] Weights [kg] Shipping volume L1 L2 H1 H2 B1 B2 G Net Gross [m 3 ] UPA 15-16 13 23 25 11 116 5 1" 2.4 2.7.81 23

6 Data sheets UPA 12, 1 x 11 V, 6 Hz Taiwan, Brazil p [kpa] 12 1 8 6 4 2 H [m] 12 1 8 6 4 2..5 1. 1.5 2. 2.5 3. 3.5 4.Q [m³/h]..2.4.6.8 1. Q [l/s] TM5 7458 113 G P1 max [W] I 1/1 [A] 215 2.1 Enclosure class: IPX2D Connections: Rp 1 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +11 C (TF 11) L1 B1 B2 H1 H2 TM6 5265 4215 Dimensions [mm] L1 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 12 18 2 13 63 69 1" 4.7 5..58 Net [kg] Gross [kg] 24

6 UPA 12, 1 x 22 V, 6 Hz Taiwan, Brazil, Korea Data sheets p [kpa] 12 1 8 6 4 2 H [m] 12 1 8 6 4 2..5 1. 1.5 2. 2.5 3. 3.5 4.Q [m³/h]..2.4.6.8 1. Q [l/s] TM5 7462 113 G P1 max [W] I 1/1 [A] 22 1.5 Enclosure class: IPX2D Connections: Rp 1 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +11 C (TF 11) L1 B1 B2 H1 H2 TM6 5265 4215 Dimensions [mm] L1 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 12 18 2 13 63 69 1" 4.7 5..58 Net [kg] Gross [kg] 25

6 Data sheets UPA 12, 1 x 23 V, 5 Hz Singapore, India, Argentina p [kpa] 12 1 8 6 4 2 H [m] 12 1 8 6 4 2..5 1. 1.5 2. 2.5 3. 3.5 Q [m³/h]..2.4.6.8 1. Q [l/s] TM5 7459 113 G P1 max [W] I 1/1 [A] 25 1.14 Enclosure class: IPX2D Connections: Rp 1 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +95 C (TF 95) L1 B1 B2 H1 H2 TM6 5265 4215 Dimensions [mm] L1 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 12 18 2 13 63 69 1" 4.7 5..58 Net [kg] Gross [kg] 26

6 UPA 12, 1 x 12 V, 6 Hz Mexico Data sheets p [kpa] 12 1 8 6 4 2 H [m] 12 1 8 6 4 2..5 1. 1.5 2. 2.5 3. 3.5 4.Q [m³/h]..2.4.6.8 1. Q [l/s] TM5 7463 113 G P1 max [W] I 1/1 [A] 225 2 Enclosure class: IPX2D Connections: Rp 1 - Rp 1/2 unions Operating pressure: Max. 6 bar Liquid temperature: +2 C to +11 C (TF 11) L1 B1 B2 H1 H2 TM6 5265 4215 Dimensions [mm] L1 H1 H2 B1 B2 G Weights [kg] Shipping volume [m 3 ] UPA 12 18 2 13 63 69 1" 4.7 5..58 Net [kg] Gross [kg] 27

7 Grundfos Home Booster Product numbers 7. Product numbers Market Argentina Australia and New Zealand Port-to-port length [mm] Terminal box position Connection Voltage [V] Frequency [Hz] Product number Data sheet page UPA 15-9 16 12 H G 3/4 23 5 5953952 12 UPA 12 18 12 H G 1 23 5 52588423 26 UPA 15-9 N 16 12 H G 3/4 24 5 5953958 14 UPA 15-9 16 12 H G 3/4 11 6 59539518 13 Brazil UPA 15-9 16 12 H G 3/4 22 6 59539517 15 UPA 12 18 12 H G 1 11 6 52588421 24 UPA 12 18 12 H G 1 22 6 5258842 25 UPA 15-9 16 12 H G 3/4 11 6 9855924 13 Brazil (white colour) UPA 15-9 16 12 H G 3/4 22 6 98559114 15 UPA 12 18 12 H G 1 11 6 98559136 24 UPA 12 18 12 H G 1 22 6 9855914 25 UPA 15-9 16 12 H G 3/4 23 5 9936677 12 China UPA 15-12 2 12 H G 1 23 5 9936678 22 UPA 15-16 23 9 H G 1 23 5 99195711 23 Czech Republic UPA 15-9 16 12 H G 3/4 23 5 59539514 12 Europe UPA 15-12 2 12 H G 1 23 5 98699677 2 UPA 15-16 23 9 H G 1 23 5 99331335 21 Global UPA 15-9 16 12 H G 3/4 23 5 59539521 17 Netherlands UPA 15-9 N 16 12 H G 3/4 23 5 9662143 18 India UPA 15-9 16 12 H G 3/4 23 5 59539511 17 UPA 12 18 12 H G 1 23 5 52588416 26 Indonesia UPA 15-9 16 12 H G 3/4 23 5 59539519 12 Japan UPA 15-9 N 16 12 H G 3/4 1 6 5953955 16 Korea Mexico UPA 15-9 16 12 H G 3/4 22 6 59539513 15 UPA 12 18 12 H G 1 22 6 52588418 25 UPA 15-9 16 12 H G 3/4 127 6 5953952 19 UPA 12 18 12 H G 1 12 6 52588422 27 Romania UPA 15-9 16 12 H G 3/4 23 5 59539516 12 Russia UPA 15-9 16 12 H G 3/4 23 5 59539512 17 Singapore UPA 15-9 N 16 12 H G 3/4 24 5 5953959 14 UPA 12 18 12 H G 1 23 5 52588415 26 UPA 15-9 16 12 H G 3/4 11 6 5953956 13 Taiwan UPA 15-9 16 12 H G 3/4 22 6 5953957 15 UPA 12 18 12 H G 1 11 6 52588413 24 UPA 12 18 12 H G 1 22 6 52588414 25 Turkey UPA 15-9 16 12 H G 3/4 23 5 59539515 12 UK UPA 15-9 N 16 12 H G 3/4 23 5 9762721 18 UPA 15-9 16 12 H G 3/4 23 5 5953951 17 28

Grundfos Home Booster 8 8. Accessories External flow switch for UPA 12 71 TM6 5193 4115 Accessories 37 4 TM6 813 4616 Fig. 12 External flow switch for UPA 12 Product number Description Product number External flow switch for UPA 12 9176166 29

9 Grundfos Home Booster Grundfos Product Center 9. Grundfos Product Center Online search and sizing tool to help you make the right choice. http://product-selection.grundfos.com SIZING enables you to size a pump based on entered data and selection choices. REPLACEMENT enables you to find a replacement product. Search results will include information on the lowest purchase price the lowest energy consumption the lowest total life cycle cost. CATALOGUE gives you access to the Grundfos product catalogue. LIQUIDS enables you to find pumps designed for aggressive, flammable or other special liquids. All the information you need in one place Performance curves, technical specifications, pictures, dimensional drawings, motor curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. The Product Center displays any recent and saved items - including complete projects - right on the main page. Downloads On the product pages, you can download installation and operating instructions, data booklets, service instructions, etc. in PDF format. 3

31

98715166 1117 ECM: 1197372 The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. Copyright Grundfos Holding A/S GRUNDFOS A/S DK-885 Bjerringbro. Denmark Telephone: +45 87 5 14 www.grundfos.com