C2000 driving IM with TQC+PG

Similar documents
VFD E Series. Features

Servo Motors B-1. Introduction B-2. NX Series B-9. Accessories B-47

Application Note CTAN #234

HIDRA CRONO Controller VVVF Control Techniques Unidrive SP (Asynchronous motors)

TOSVERT VF-S11. V/F control functions

APPLICATION NOTE. Labeling Machine

Tension Control Inverter

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Servo Motors ver ver.4

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Technical Explanation for Inverters

Expanding Application of FRENIC-Lift Series for Elevators

CRANE FUNCTION MANUAL. FR-A (0.4K) to 04750(90K)-CRN FR-A (0.4K) to 06830(280K)-CRN FR-A (315K) to 12120(500K)-CRN

StepSERVO Tuning Guide

SP5 INSTALLATION AND SETUP MANUAL

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Instruction manual with V3 motor

Application Note: SyMAX Permanent Magnet Motor Simple Startup Procedure

HBI 22. Integrated Three-phase Synchronous Drive

MASTERDRIVE Compact Plus

UE-MINI HYDRO BOOSTER SYSTEM

SDC,Inc. SCR-Regenerative Ac Drive

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

Delta Products VFD CP2000 Bypass Control Packages.

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

SYSDrive Frequency Inverter

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

TRIPS AND FAULT FINDING

C1 Controller & Driver. User s Guide

SD1 Series General Purpose AC Variable Speed Drives

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Dynaserv G2 Digital Servo Drives

2232 S 024 BX4 CSD/CCD 24 12,4 6,4 67,7 2 / 17 4,1 / ball bearings, preloaded 0,015. stainless steel 77 electronically reversible

3242 G 024 BX4 CS/CC 24 3,6 18,2 77,3 1,6 / 12,4 9 / ball bearings, preloaded 0,015. stainless steel 370 electronically reversible

List of Tables: Page # Table 1: Emerson Commander SK VFD parameter settings 2. Table 2: Allen Bradly Power Flex 4M VFD parameter settings 3

User Manual. V6/V5 T T8 Tension Control Inverter

GHD Global Help Desk. HOISTING commissioning with ATV71 03/2010

Mitsubishi. VFD Manuals

APPLICATION NOTE

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Configuration IN THIS CHAPTER 23

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

Inverter control of low speed Linear Induction Motors

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

Troubleshooting. YASKAWA ELECTRIC SIEP C D YASKAWA AC Drive A1000 Technical Manual 301

GS2 Series - Introduction

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

zub A Software Kernel for Servo Drives and Frequency Converters machine control AG

Stepper Motors ver ver.5

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

Fincor Series 2230 MKII/2240

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

Synchronous Motor Drives

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Technical Guide No. 7. Dimensioning of a Drive system

Technical Reference H-37

Hybrid Control System, Alpha Step

ABB Sace S.p.A. presents its new BSD servo system, a compact, high-performance and easy product.

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

Frequency Inverters SJ Series Type P1

User s Manual. For DM542T. Full Digital Stepper Drive

Bistable Rotary Solenoid

YASKAWA AC Drive High Performance Vector Control A1000

YASKAWA AC Drive High Performance Vector Control A1000

FUJI FRENIC INVERTER USER GUIDE

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

ALTIVAR 58 AC Drives

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

APPLICATION GUIDE. Pure easiness for a wide range of applications ACS580 general purpose drives

Additional Instruction of _STOCK Firmware

Addendum to Instruction Manual GP10 and VG10

SINAMICS GM150 IGCT version

Small step, big impact: Energy efficiency and dynamic performance

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278.

MAGPOWR Spyder-Plus-S1 Tension Control

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Driving Characteristics of Cylindrical Linear Synchronous Motor. Motor. 1. Introduction. 2. Configuration of Cylindrical Linear Synchronous 1 / 5

Introduction to hmtechnology

CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION. Professor Dae Ryook Yang

Operating Manual For Stepper Driver

1. An inverter can be programmed to stop an AC motor quickly by enabling

Linear Alignment. motion. 2 Flexible combination of XY. 4 High resolution and high responsiveness. accuracy. Optical linear encoder scale head

Overvoltage Suppression F7 Drive Software Technical Manual

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

For motors controlled

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

HIGH POWER SOLENOID DRIVER 1

690+ Series Integrator

Piktronik d. o. o. Cesta k Tamu 17 SI 2000 Maribor, Slovenia Fax:

Introduction The aim of this application note is to outline how to configure an ACSM1 drive to run with an ABB BSM series AC servo motor.

RVS-DX Digital Reduced Voltage Motor Starter

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-10 PELTIER TEMPERATURE CONTROL SYSTEM

Transcription:

Product AMD Type VFD-C2000 Issued by SC Author Leo Yang Security Level No. Release Date General High Top N/A 30 th May, 2012 C2000 driving IM with TQC+PG Devices and tools: Inverter:VFD007C43A, 1PCS (Firmware V1.01 D12055) Induction motor:teco/3phase/380v/0.75kw PG:EMC-PG01L 1PCS Operation Steps: 1. Set Pr00-02=9(50Hz) or 10(60Hz) to go back factory setting. 2. Set the following parameters based on IM motor you are using: Parameters Definition Value 01-00 Induction motor max frequency (Hz) 50.00 01-01 Induction motor rated frequency (Hz) 50.00 01-02 Induction motor rated voltage (V) 380.0 05-01 Induction motor rated current (A) 2.0 05-02 Induction motor rated power (kw) 0.75 05-03 Induction motor rated speed (rpm) 1410 05-04 Induction motor pole numbers 4 3. Set Pr05-00=1 and press run to begin auto-tuning in rolling test. Make sure the motor has no-load before executing auto-tuning and the shaft is not connected to any belt or gear motor. It is recommended to set to 2 if the motor can t separate from the load. If Pr.05-00 is set to 2 (static test), user needs to input the no-load current value of motor into Pr.05-05 for motor 1/Pr.05-17 for motor 2. The figure is about 40% of the rated current. 4. Check the following parameters after IM rotary auto-tuning. When auto-tuning is completed, please check if the measured values are written into motor Product Solutions Announcement - 1 -

1(Pr.05-05 ~05-09) and motor 2 (Pr.05-17 ~05-21) automatically. 5. Set parameters about encoder. Pr 10-00 Encoder Type 1 Pr 10-01 Encoder pulse 1024 Pr 10-02 Encoder Input Type 1 6. Set Pr00-11=2 for IM FOC+PG control mode. Keep Pr00-10=1 which means velocity mode, and set Pr00-11 to 2 for IM FOC+PG mode. Set a low speed for the inverter, for example 10 Hz and press Run to make sure the inverter is working properly. If not, check the wiring or change Pr10-02 to 2, then, try again. 7. Set Pr11-00=2 for inertia auto-tuning: Set speed command=2/3*rated speed of motor (05-03). Set acceleration and deceleration time is 1s or 1.5s. Forward and reverse in turn until 11-01 is stable. 8. Set ASR parameters based on the practical situations: Please set 11-03 11-04 11-05 if we set Pr11-00=1 and finish the inertia auto-tuning. Please set 11-06 to 11-11 if we set 11-00=0 which doesn t need the inertia auto-tuning. 9. Set Pr00-10=2 for torque mode and Pr00-13=0 for TQCPG mode. TQCPG mode is based on FOCPG mode, so if you want to use this mode, you have to finished the FOCPG mode settings first, then, change Pr00-10 to 2 for torque mode. 10. Set Pr11-27=100: maximum torque command according to your real situation. This parameter is used to set the upper limit of torque command, and the factory setting is 100%. 11. Set Pr11-33=0 to choose the source of torque command. Parameter Value Definition 0 Digital Keypad (Pr11-34) 1 RS485 serial communication 2 Analog signal (Pr03-00) 11-33 3 CANopen 4 Reserved 5 Communication Card Product Solutions Announcement - 2 -

In this case, set Pr11-33=0, which means the torque command source comes from the digital keypad, and the value can be set in Pr11-34. For example, if you need 50% torque, you can just key in 50 in Pr 11-34. The interval of Pr11-34 is changeable according to Pr11-27. 12. Set Pr11-36=0 to choose the source of speed limitation. Parameter Value Definition 0 Set by Pr.11-37 (Forward speed limit) and Pr.11-38 (Reverse speed limit) 11-36 1 Set by Pr.11-37,11-38 and Pr.00-20 (Source of Master Frequency Command) 2 Set by Pr.00-20 (Source of Master Frequency Command). You can set Pr11-36 to choose the source of this speed limitation. In this case, set Pr11-36=0 to choose Pr11-37&Pr11-38 as the source of speed limitation. In TQCPG mode, when the motor speed is accelerated to speed limit value (Pr.11-36, 11-37 and 11-38), it will switch to speed control mode to stop acceleration. 13. Set forward and reverse speed limit. Set Pr11-37=10, Pr11-38=10, here 10 means 10% of Pr01-00 max output frequency. For example, if you set Pr01-00=50Hz, forward and reverse speed limit will be 5Hz. 14. Set torque offset according to your real situation: Choose the source of torque offset Pr11-28: 0, Disable 1, Analog input (by Pr03-00) 2, Torque offset setting (by Pr11-29) 3, Control by external terminal (by Pr11-30 to Pr11-32) If Pr11-28=1, torque offset comes from analog input, then, set Pr03-00=3. If Pr11-28=2, torque offset comes from Pr11-29, key in the figure you need. If Pr11-28=3, torque offset comes from external terminals, you have to choose three multi-function input terminals, for example, MI1,MI2,MI3, and set Pr02-01=31(low torque offset), Pr02-02=32(middle torque offset), Pr02-03=33(high torque offset). Low/middle/high torque offset will take effect when the particular MI port is on. 15. Set ASR control at Torque mode according to your real situation: ASR control function under torque mode is now contained in firmware V1.01 date12055. If you Product Solutions Announcement - 3 -

want to adjust PI value in the ASR of torque mode, please refer to Pr10-24: Bit#0 0:Use P as ASR 1: Use PI as ASR There is a small mistake in present, the value is opposite. Then, adjust Pr11-06~Pr11-11 if you set Pr11-00=0. Attentions: 1. How to make auto-tuning when load cannot be taken off from the motor? There are two auto-tuning functions in C2000, one is Pr05-00=1(dynamic auto-tuning) and the other is Pr05-00=2(static auto-tuning. We can use dynamic auto-tuning when the motor is empty load, but when the motor is on load, this function will not take effect. In that condition, we have to use static auto-tuning instead. The operation steps of these two ways is just the same, the only difference between them is that when you use static auto-tuning, you need to input the no-load current value of motor into Pr.05-05 for motor 1/Pr.05-17 for motor 2. The figure is about 40% of the rated current. 2. In TQCPG mode, the output frequency rises immediately or speeds up with a accelerate time? In standard factory firmware, if you choose Pr11-37&Pr11-38 as your speed limitation, the output frequency will rise immediately without a accelerate/decelerate time; if you choose frequency command as your speed limitation, the output frequency will speed up or decelerate with a accelerate/decelerate time, and you can adjust this time in Pr01-12~Pr01-19. 3. In TQCPG mode, is there any output torque or power when output frequency is zero? If torque command is 0%, the motor will produce excitation current but no torque current. It s mean that there is not any output torque or power there. If you do want to make an output torque there, you can set Pr11-39=1. This parameter defines the torque command mode at 0% of torque output. When Pr.11-39 is set as 1 (the speed mode), if torque command is 0%, the AC motor drive can still produce torque current through speed controller to prevent motor race and the drive will also automatically adjust the speed to 0 when the speed command is not equal to 0. 4. What s the difference between P and PI in ASR control? P is used to eliminate the system error. It is usually used to decrease the error and get the faster response speed. But if setting too large value, it may cause the system oscillation and instability. I is used to eliminate the error during stable system. The integral control doesn t stop working until error is 0. The integral is acted by the integral time. The smaller integral time is set, the stronger integral action will be. It is helpful to reduce overshoot and oscillation to make a stable system. At this moment, the decreasing error will be slow. The integral control is often used with Product Solutions Announcement - 4 -

other two controls to become PI controller or PID controller. Product Solutions Announcement - 5 -