Installation, Operation and Maintenance Manual

Similar documents
Installation, Operation, and Maintenance Manual. Automatic Fire Damper

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

MA40-704X Series MA41-707X Series MA41-715X Series

General Description. Product Specification. Document Digital Temperature Interlock

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Installation, Operation and Maintenance Manual

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Installation, Operation and Maintenance Manual

LF Series Spring Return Direct Coupled Actuator

MA-5200 Series MA-5300 Series

AF Series Spring Return Direct Coupled Actuator

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

MS Series MS Series MS Series

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Pro Island Ventilation Hoods

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Installation Instructions

Electrical Control Panel

MC-351, 421, 431, MC-4311

Installation Instructions

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

M100F Incremental Motor Actuator R81F Interface Board

M Remote Mounting Kit

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

The Da-Lite Difference.

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

MF4E MF4E

FSAF24(-S) US, FSAF120(-S) US

Installation Instructions

MF Series MF Series MF Series

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

The Da-Lite Difference.

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Quarter Master Series 94 Actuator

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Utility Distribution System

Installation Instructions

Powers TM Controls EA 338 Electronic Actuator

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

Invensys Energy Solutions 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL United States of America

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

The Da-Lite Difference.

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

Installation Instructions

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Versatile and Powerful

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Installation, Operation and Maintenance Manual

INSTALLATION MANUAL. Melink Corporation (513) Revision

Belimo is the Worldwide Leader in Fire and Smoke Actuation

Installation Instructions

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Minimum 27 in-lb torque

E.S.P. Embedded Sensing Probes for Motor Brushes

Series 41 and 81 Modutrol IV Motors

Owner s Information Manual

Installation Instructions

ELECTRONIC FIREPLACE DAMPER

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

Installation Instructions

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)

Mounting Installation Instructions LM, NM, AM, GM

Installation Instructions

M9216 Series Electric Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Installation Instructions

Installation and Operating Manual

Instruction Book for. ContouR ElECtRol

IMPORTANT ATTENTION INSTALLERS:

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

WhispAire Range Hood Quiet Hood

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

NUTONE RANGE HOOD NTM SERIES

Installation Instructions Electric Heaters 5 20 kw

Quarter Master Chief Series 92 Actuator

Transcription:

Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Automatic Fire Damper Function Designed to close in fire situations Reset by activating the reset switch UL Listed Constructed in accordance with NFPA 96 The automatic fire damper is a thermostatically controlled, resettable fire damper designed to prevent the spread of fire into the kitchen exhaust ductwork. The thermostat is designed to provide automatic closure in the event of a fire where duct temperatures exceed 280ºF. These conditions would typically exist after the first line fire suppression system failed to extinguish the fire. The damper will then close and shut off the exhaust fan along with any make-up air equipment, preventing the fire from entering the duct. The damper is reset by activating the reset switch after the thermostat has cooled to a temperature less than 280ºF. When the damper is fully open, power to the exhaust fan and make-up air will be restored. Testing the damper requires activating the test switch, typically mounted on the face of the hood, or in a separate control panel. The damper will then close, as if the thermostat had reached 280 F. To return to normal operation simply activate the reset switch. The automatic fire damper is not intended to function as an air controller. All fire dampers connected to a common fan will function simultaneously allowing the fan to be on only when all dampers are fully open. Many local code authorities do not recommend or allow the use of fire dampers. For this reason, consult your local code authorities for specific requirements. Table of Contents DANGER Always disconnect power before working on or near any electrical components in the hood. If necessary, lock and tag the breaker servicing this equipment to prevent accidental power up. Only qualified personnel should install and service this system and they should be aware of general safety precautions. NOTE Follow all local electrical and safety codes, as well as the National Electrical Code (NEC), and the latest edition of the National Fire Protection Agency Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations (NFPA 96). Follow the Canadian Electrical Code (CEC) and ULc-S650 if installing this product in Canada. CAUTION It is the responsibility of the installer to make sure both electrical and gas appliances shut down in the event of a fire or in the event of a power loss to the building when this sequence is required by the authority having jurisdiction. Automatic Fire Damper Function.... 1 System Components....2-3 Installation.... 3 Electrical Requirements.... 4 Control Box Wiring Diagram.... 5 Start-Up.... 6 Maintenance.... 6 Operation.... 6 Troubleshooting.... 7 Installation of Actuator....8-10 Maintenance Log.... 11 Our Commitment.... 12 Automatic Fire Damper 1

System Components Damper, Actuator, and Linkage Assembly The damper, actuator, and linkage assembly will be factory installed. The damper is located in each exhaust collar, its actuator and linkage assembly just outside the collar. Damper Control Panel The damper control panel will include at least a threeposition momentary reset/test switch and an open indicator light inside a two-gang electrical junction box. RESET controls the opening of the damper and TEST controls the closing of the damper under daily conditions. The indicator light illuminates when the damper is completely open, and power is restored to the exhaust fan and make-up air. Mounting options: Hood mounted (face of hood) Utility cabinet mounted Shipped loose (for remote mounting) Mounted on UDS (Utility Distribution System) Mounted on KFCC (Kitchen Fan Control Center) door Dimensional details: Control Box The control box will include relays and terminal blocks for field wiring connections. This 8 x 8 x 4-inch (203.2 x 203.2 x 101.6 mm) NEMA 3R box will be painted. Figure 1 on page 3 shows the typical placement of the hood mounted control box. Mounting options: Hood mounted (on top of hood) Shipped loose (for remote mounting) Dimensional details:.594 inches.5 inches FRONT VIEW 9.875 inches 6.563 inches 4.509 inches 8.0 inches RESET TEST OPEN 4.509 inches TOP VIEW 5.313 inches EXHAUST DAMPER FRONT VIEW 3.75 inches 8.0 inches 4.215 inches SIDE VIEW TOP VIEW 2.50 inches SIDE VIEW 2 Automatic Fire Damper

System Components - continued Control Box 120/60/1 Installation If shipped loose, mount the control box and/or damper control panel. Access to the control box, thermostat, actuator and linkage must be available for possible maintenance. Actuator and Linkage Assembly 7.9 in. Thermostat (inside junction box) 12 in. Damper Control Panel NOTE For hoods with fire dampers in the exhaust (and/or supply) duct collars, an access panel for cleaning and inspection shall be provided in the duct. This panel shall be as close to the hood as possible and not exceed 18 inches from any hood damper. (Factory recommendation). FIGURE 1: Hood Mounted Control Box with Hood Mounted Damper Control Panel The damper control panel must be mounted so that it is accessible for daily use and its location may need to comply with ADA Standards for Accessible Design. For any readjustment on the linkage, refer to the actuator field installation instructions on beginning on page 8. Automatic Fire Damper 3

Electrical Requirements NOTE All wiring must be in accordance with National Electrical Code (NEC) NFPA 70 guidelines and local building codes. Standard electrical requirements assume one hood per fan. A special wiring diagram may be needed if there are multiple hoods exhausted by one fan or if interfacing with other items such as a fan control center. Consult the factory if a special wiring diagram is needed, or if the correct wiring diagram is missing. A control box wiring diagram can be found on page 5. The table below indicates which wiring diagram to use for each situation that would normally occur with the automatic fire damper assuming one hood per fan. When selecting the drawing, take into account these options: Control Box (Control Cabinet) Damper Control Panel (Damper Switches) Hood Switches for Light(s), Fan(s), Tempering (Heating or Cooling Supply Air) Number of Ducts(s) = Number of Damper(s) Drawing Numbers Control Box Control Panel (Damper Switches) Hood Switches One Damper (Drawing #) Two Dampers (Drawing #) *** *** *** M24778 M24782 *** *** --- M24777 M24781 *** --- --- M24776 M24780 --- --- --- M24775 M24779 *** Hood Mounted Control --- Remote Mounted Controls Conditions: 1. If Control Box, Damper Control Panel (Damper Switch(s)), and Control Panel (Hood Switches) are all hood mounted use drawing: For one Exhaust Damper - M24778 For two Exhaust Damper(s) - M24782 2. If Control Box and Damper Control Panel (Damper Switch(s)) are hood mounted, but the Hood Control Panel (Hood Switch(s)) are remote mounted use drawing: For one Exhaust Damper - M24777 For two Exhaust Damper(s) - M24781 3. If the Control Box is hood mounted but both the Control Panel(s) are remote mounted use drawing: For one Exhaust Damper - M24776 For two Exhaust Damper(s) - M24780 4. If the Control Box, Damper Control Panel (Damper Switch(s)), Hood Control Panel (Hood Switch(s)) are all remote mounted use drawing: For one Exhaust Damper - M24775 For two Exhaust Damper(s) - M24779 NOTE All field connections must use UL Listed conduit and fittings. 4 Automatic Fire Damper

Control Box Wiring Diagram CONTROL INPUT: 115VAC, 15AMPS FROM BREAKER G H AD4 N BK 11 R1 14 R2 OPTIONAL THERMOSTATS RD 11 12 YW WH TH1 TH2 R1 T1 T2 T(last) A1 A2 "RESET" "TEST" BK BK R1 22 21 AD5 S1 AD3 PR RL R2 A1 A2 LT1 "RESET" 21 R1 24 BL AC1 A1 AC2 A2 WH WH GND LABEL DESCRIPTION T1, T2, T3,... R1 R2 S1 Thermostats Relay 3PDT 120VAC Coil Relay DPDT 120VAC Coil Test/Reset Switch AUX Auxiliary Device E1 Exhaust Fan Circuit LS1, LS2,... Actuator Mounted Limit Switches S2 Fan Switch A1, A2, A3,... Damper Actuators LT1 Optional Red Reset Light LT2 Green Operational Light NOTES: 1) ONE THERMOSTAT REQUIRED FOR EACH FIRE DAMPER 2) SHORT CIRCUIT AND OVERLOAD PROTECTION PROVIDED BY OTHERS BK 31 R1 34 BL AUX1 AUX AUX2 (OPTIONAL) TO SLAVE CONTROL CABINET LS1 LS2 LS3 LS(last) OPTIONAL ACTUATOR MOUNTED LIMIT SWITCHES S2 A3 A4 A5 A6 A7 A8 LT2 "OPERATIONAL" E1 TORQUE: TERMINAL BLOCKS = 8 LB.IN GROUNDING BLOCKS = 8 LB.IN FIELD WIRING: USE MINIMUM 60 Copper Wire WIRE COLOR BK - black BL - blue BR - brown OR - orange PR - purple RD - red YW - yellow WH - white FACTORY WIRING FACTORY INSTALLED TERMINAL JUMPER CLIP OPTIONAL FACTORY WIRING OPTIONAL FIELD WIRING UL LISTED ALL WIRING 90 C 14 GA. UNLESS SPECIFIED Automatic Fire Damper 5

Start-Up Check the wiring connections to ensure proper installation. Open the damper by pressing the reset switch in the control panel. Allow 20 seconds for the damper to fully open. Make sure both the indicator light and fan are on. Visually verify that the damper behind the filters is open. Activate the test switch. Make sure the indicator light and the fan are off. Visually verify that the damper is closed. Maintenance The automatic fire damper is designed to be a maintenance-free damper (there is no link to replace). Testing the damper at least once a week is recommended to ensure proper function in the event of a fire. Visually verify that the damper is opening and closing when testing. If the damper isn t functioning properly, refer to the Troubleshooting section on page 7. WARNING If damper will not open after testing, do not continue to use cooking appliances until this is fixed. Operation Fire 1. At a thermostat temperature of 280ºF, the damper will close, and any exhaust fan(s) and make-up air connected to the damper(s) will shut off. 2. The damper will remain closed until the reset switch is activated and the thermostat has cooled to less than 280ºF. Reset 1. The damper(s) will open when the reset switch is activated. 2. When the damper is fully open the indicator will light and power will be provided to the exhaust fan and connected make-up air. Test 1. The damper will close when the test switch is activated. 2. The indicator light will shut off. 3. The power to the exhaust fan and the connected make-up air will be disconnected. 4. The damper(s) will open when the reset switch is activated. 5. The indicator will light and power will be provided to the exhaust fan and connected make-up air when the damper is fully open. Daily 1. Fan control and operation will not affect the open damper(s). 2. The indicator light will signify normal operation of the system with an open damper(s). 3. The user may test the damper nightly to shut off all fans and close the damper(s), eliminating nightly drafts of air through the ductwork. WARNING The main purpose of the automatic fire damper is to close off the exhaust ductwork in the event of a fire under the hood. If the user activates the test switch at night (closes the damper), but fails to reset the switch in the morning and proceeds to cook/use the appliances under the hood, this can cause heat build-up. Eventually this can start a fire and/or dump the fire suppression system. Consult your local code official for what is and is not allowed with respect to the functionality of the automatic fire damper and the appliance interfacing with this product. Make sure all kitchen staff who will be working with this product fully understand its function. 6 Automatic Fire Damper

Troubleshooting Problem: Automatic fire damper is not opening. Is the damper reset? Is the power being supplied to the damper circuit? Are the relays and switch working properly? Is the damper stuck? Is the actuator getting power? Activate the reset switch and visually verify that the damper is opening. To verify power is being supplied to the damper circuit, measure the voltage across terminals 1 and 2 in the control box to be sure the proper line voltage is being supplied. Relays are located in the control box. R1 will engage when the reset switch is actuated, R2 will engage momentarily when the test switch is activated, disengaging R1. If the relays are not functioning properly, the problem may be a faulty relay or reset/test switch. Check the damper to make sure it is free from obstruction. Proper line voltage should exist across terminals L1 and L2 on the back of the actuator when the power is on and the reset switch is activated. The actuator may be faulty if it is receiving power and not in the open position. If the actuator is not receiving power verify the thermostat is providing contact. Problem: Indicator light is not on. Is the light bulb burned out? Is power being supplied to the exhaust fan? Is the limit switch making contact? Is the damper linkage adjusted properly? Remove the control panel switch cover to confirm that the light bulb is functional. Power supplying the fan starter supplies the indicator light. It is possible the fan overload breakers have tripped. Verify that the actuator limit switch (terminals C and N.O. in back of the actuator) is making contact when the damper is open. Refer to the actuator installation instructions.. Problem: Automatic fire damper is not closing. Is the damper linkage adjusted properly? Is the damper blade clear of obstructions? Has the actuator s internal spring failed? Refer to the actuator installation instructions. The actuators internal spring should rotate its shaft to the normal position when power is not being applied. (Contacts L1 and L2). Problem: Hood is not exhausting effluent properly. Refer to the hood Installation, Operation and Maintenance manual for troubleshooting tips on improving hood performance. Automatic Fire Damper 7

Installation of Actuator MA & MC Series, UL Listed electric actuators with two position control. These instructions apply to the external field installation of Invensys actuators. Invensys actuators rotate to their energized position when power is applied and spring return to their fail position when power is interrupted, except for the MC-431 which drives under power in both directions. Control Shaft to Damper Direct Drive 17 These parts are for use with a 1 in. shaft 11 10 Jackshafted Rotate as required (typical) 20 6 12 15 13 6 16 9 7 14 14 8 7 9 3.0 in. 1 19 8 3.0 Ref. 14 2.25 Ref. 6 Spring 13 4 5 2 3 6 Item Qty Description 1 1 Actuator 2 1 Mounting Bracket 3 1 Mounting Plate 4 4 1/4-20 x 1/2 in. Thread Stud 5 3 1/4-20 x 3/4 in. Thread Cutting Screw 6 10 1/4-20 Spinlock Nut 7 3 1/2 in. Crankarm 8 3 5/16-18 x 1-1/2 in. Bolt 9 3 5/16-18 Spinlock Nut 10 1 1 in. Crankarm 11 1 3/8-16 x 2-1/2 in. Carriage Bolt 12 1 3/8-16 Spinlock Nut 13 2 Linkage Adjustment Pin 14 2 1/4 in. E-ring 15 1 Drive Link 16 1 Stand-Off Bracket 17 4 1/4 - x 20 x 1/2 in. Thread Cutting Screw 18 1 Ball Bearing 19 1 1/4 x 1/2 in. Knurl Pin 20 4 1/4-20 x 1/2 in. Hex Bolt 21 2 #10 Tek Screw MA & MC Installation Instruction Part #454199, Rev. 4, September 2007 8 Automatic Fire Damper

TOOLS REQUIRED 6. Assembly the linkage. Wrenches: (1) 3/8, (2) 1/2, (1) 7/16, and (1) 9/16 in. and a hammer. 1. Install the stand-off bracket to the damper. 11 10 6 12 One-inch shaft Steps 6a and 6b Parts needed 13 14 9 3.0 in. 15 6c 14 7 8 7 9 Orientation of stand-off bracket for a jackshaft driven damper. Orientation of stand-off bracket for a directly driven damper. Dampers with a jackshaft 1a. Mount the stand-off bracket onto the jackshaft bracket with four 1/4-20 x 1/2 in. thread cutting screws. Use the orientation shown on this page. Dampers without a jackshaft (shaft extension) 1b. Mount the stand-off bracket spanning across the damper frame flanges positioned over the control shaft. Use the orientation shown on this page. The damper shaft must be centered in the stand-off bracket. Fasten to the damper frame with four #14 Tek screws or equal, supplied by others. Be sure not to run the screws into the damper linkage which is between the flanges. 2. Fasten the mounting plate to the mounting bracket using four 1/4-20 x 1/2 in. thread studs and four 1/4-20 spinlock nuts through the matching A four hole pattern on the mounting bracket labeled A on the illustration. Note that the mounting plate has only one pattern that A will match the mounting plate pattern. Mounting Plate 3. Mount the mounting bracket to the stand-off bracket using four 1/4-20 x 1/2 in. bolts and four 1/4-20 spinlock nuts included with this kit. Use the outer four holes of the mounting bracket for jackshafted models and the inner four holes for directly-driven models. 4. If the damper has a 1/2 in. diameter damper shaft, mount the ball bearing into the mounting bracket with two #10 Tek screws. The Tek screws are required to keep the thrust forces from pushing the bearing out of the mounting bracket. If the damper shaft is one-inch in diameter, then no ball bearing is required. 5. Mount the actuator to the mounting plate in the corresponding holes using three 1/4-20 x 3/4 in. thread cutting screws. Note that the actuator must be mounted with the shaft in the horizontal position. 19 1/2-inch shaft Steps 6a and 6b Parts needed 8 Linkage Exploded View Parts needed for dampers with 1/2 in. shaft Item Qty Description 6 1 1/4-20 Spinlock Nut 7 3 1/2 in. Crankarm 8 3 5/16-18 x 1-1/2 in. Bolts 9 3 5/16-18 Spinlock Nuts 13 1 Linkage Adjustment Pin 14 2 1/4 in. E-ring 15 1 Drive Link 19 1 1/4 x 1/2 in. Knurl Pin Parts needed for dampers with 1 in. shaft Item Qty Description 6 2 1/4-20 Spinlock Nut 7 1 1/2 in. Crankarm 8 1 5/16-18 x 1-1/2 in. Bolt 9 1 5/16-18 Spinlock Nut 10 1 1 in. Crankarm 11 1 3/8-16 x 2-1/2 in. Carriage Bolt 12 1 3/8-16 Spinlock Nut 13 2 Linkage Adjustment Pin 14 2 1/4 in. E-ring 15 1 Drive Link 6a. Assemble the shaft crankarms. For dampers with 1/2 in. shaft The crankarms must be placed as mirror images of each other, meaning the like sides face each other. The bolts and nuts are to be positioned as in the linkage exploded view drawing. For dampers with 1 in. shaft The 1 in. crankarm, item 10, must be in the position shown in the shaded encircled exploded view above. Position the bolt and nut as shown in the same diagram. 14 13 6d Automatic Fire Damper 9 6 2¼ in.

6b. For dampers with 1/2 in. shaft Insert the knurl pin through both of the small holes in the crankarms and tap it into place using a hammer. For dampers with 1 in. shaft Insert the linkage adjustment pin, item 13, into the crankarm slot. Position it 3 in. from the center of the damper shaft hole and fasten with a 1/4-20 spinlock nut (see shaded encircled diagram). 6c. Attach the drive link, item 15 to the damper shaft crankarm(s). For dampers with 1/2 in. shaft Insert the knurl pin through one of the drive link holes. Fasten with an E-ring. For dampers with 1 in. shaft Insert the linkage adjustment pin, item 13, through one of the drive link holes. Fasten with an E-ring. 6d. Attach the drive link to the actuator crankarm with the linkage adjustment pin, a spinlock nut and an E-ring. Set the linkage adjustment pin at 2-1/4 in. on the crankarm and secure it there with the spinlock nut. Fasten the other end through the empty drive link hole with the E-ring. 7. Note the damper shaft rotation for fail direction and orient the linkage appropriately as shown in the illustrations. The damper linkage is now in its fail position. Position the Damper Shaft damper blades to their proper position (open or closed). Tighten the bolts. NOTE While the MC series actuator installs and links the same as the MA series, the wiring is different. A three wire control circuit is required because the actuator runs under power to both open and close the actuator. This actuator does not spring return. L1 or H L2 or G Thermostat or Switch One SPDT switch can only control one actuator SPDT Snap-Acting Control R B C C1 Aux. Switch Damper Actuator B rotates 0º to 180º R rotates 180º to 360º (0º) Aux. Switch (-500 Models) COM Wiring Diagram for MA Series Actuators Wiring Diagram for MA Series Actuators H G R1 B1 H G NC NO AC Supply Actuator These terminals are marked L1 and L2 on line voltage actuators Damper Shaft Return 2¼ in. Power Fail Position Power Position Clockwise to Fail Position 10. Apply power to the actuator. The damper blades should fully open or close and return to the fail position when power is disconnected. If they do not, adjustments can be made by resetting the crankarm position on the damper or actuator shaft, or adjusting the 2-1/4 in. dimension as discussed in Step #6d. Power Position Return 2¼ in. Fail Position Power Counterclockwise to Fail Position 8. Orient the actuator crankarm so that it will rotate through the full stroke of the actuator with the shaft crankarms rotating only 90 degrees without power. Adjust the position as necessary. Tighten all of the crankarms. 9. Wire the actuator according to the appropriate wiring diagram that identifies the actuator s electrical connections. Wiring should be per an approved project or job wiring diagram and must comply with all applicable electrical codes. NOTE Motors in models MA-318 and MA-418 switch to a holding winding at the end of their stroke. Motor may overheat if stalled before cycling to the end of the power stroke. Actuator Part Number Power Supply Aux. Switch VA Running Holding MA-305 24 No 56 56 MA-305-500 24 Yes 56 56 MA-405 120 No 48 48 MA-405-500 120 Yes 48 48 MA-318 24 No 92 32 MA-318-500 24 Yes 92 32 MA-418 120 No 108 42 MA-418-500 120 Yes 108 42 MC-431 120 Yes 96-10 Automatic Fire Damper

Maintenance Log Automatic Fire Damper 11

Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, provides additional safety information. This publication can be obtained from AMCA International, Inc. at www.amca.org. Phone: 715.359.6171 Fax: 715.355.2399 Parts: 800.355.5354 E-mail: gfcinfo@greenheck.com Website: www.greenheck.com 12 458295 Automatic Fire Damper, Rev. 3, June 2015 Copyright 2015 Greenheck Fan Corporation