HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3

Similar documents
SPECIFICATIONS FOR MOTOR OPERATED VALVES

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

TECHNICAL SPECIFICATIONS FOR STEEL PLATES

Oilmist Lubrication Applications In Refineries- Installation & Maintenance Issues

NECO Pumping Systems

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

FEPL ENGINEERING. Oil Mist Lubrication Systems. Service Driven. Practical Innovations. FMC Series Model FMC 750

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

34-SDMS-01 SPECIFICATIONS FOR

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

CENTAC C700 Start-Up Services

Rosemount 285 Annubar Pak-Lok Assembly

SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU Lts.

MODEL 10LH SPECIFICATION

Technical Information Liquiline System CAT810

Modular Instrumentation System

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

technical catalogue tetris KW Chiller and heat pumps air/water

MAP Sensor. Technical Spec COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED ECOTRONS LLC. -Manifold Absolute Pressure Sensor

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered.

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Transformer Components & Accessories

Copeland Screw TM Compressors

Purging Air From Divider Block Lubrication Systems

AIR COOLED CHILLERS WATER COOLED CHILLERS

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

DS Series Solar System

ANSI Z50.1. Safety Standards

Series 774 Automatic Skid Package

Rosemount 485 Annubar Threaded Flo-Tap Assembly

(770) Turning Parts Changers Into TROUBLESHOOTERS!

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

ENGINEERING STANDARD FOR MACHINERY PIPING

STANDBY EMERGENCY CNG/LPG GENERATOR

MSC Guidelines for Fuel Oil Systems

22 Kg/Sq.cm gauge at 55deg C. As per Design Code requirement. 100% requiredfor entire vessel

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Technical Information for PVX Series Pumps

Features 1. Differential Latch-type, lightweight, dependable

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

UD SERIES COMPRESSORS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

GENERAL-SERVICE COMPRESSED-AIR PIPING SECTION GENERAL-SERVICE COMPRESSED-AIR PIPING PART 1 - GENERAL

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt

SOLAR HEATING SYSTEM

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

ECONOMISER SERIES E2T USER MANUAL

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Technical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS

Type 2000 Transducer Product Instructions

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Installation, Operation and Maintenance Manual

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

Date: Project #: Engineer: Prepared By: Bid Date:

Wet pipe low flow foam/water manifold system

Pneumatic High-Viscosity Filtration System Instruction Manual

G72x Series Direct Spark Ignition Controls

Section 9: Centralized Lubrication Systems

SECTION AIR TERMINAL UNITS

SAMPLE SPECIFICATIONS

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

Installation, Operation and Maintenance Manual

HTX-HTH SEPARATORS I&O MANUAL

M-3025CB-AV Fuel Pump

Section 3 Technical Information

ROOTS Meters Series B3 Meter Models 8C175-56M175

Publication No.: PSG

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

SPECIFICATION OF TRAILOR MOUNTED SEWER JETTING MACHINE RAMJET 1500 Lts.

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

SECTION MOTOR CONTROL

Installation, Operation and Maintenance Manual

Installation Instructions

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST FOR

SECTION H3 TRAYMASTER SERIES DEAERATORS

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

VTZ variable speed Reciprocating compressors

TotalPac 3 Firecyle III Wet pipe Remote controlled system

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

TotalPac 3 Deluge, Electric release Remote controlled system

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Installation and Maintenance Manual

ITS-50R TRANSFER SWITCH OWNER S MANUAL

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data:

Transcription:

Page 1 of 7 HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3 STANDARD SPECIFICATION FOR OIL MIST LUBRICATION SYSTEM DOCUMENT NO : 44LK-5100-704/M.02/0024/A4 Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 21-May-09 7 Issued for FEED SBN PDB SNG

HPCL, MUMBAI Standard specification PART V SULPHUR BLOCK for Oil mist lubrication system SECTION : 3.3 44LK-5100 Doc No.: 44LK-5100-704/M.02/0024/A4 Page 2 of 7 TABLE OF CONTENTS 1.0 SCOPE 3 2.0 GENERAL requirements 3 3.0 INSPECTION AND TESTING 6 4.0 PACKING 6 5.0 DOCUMENTATION 6 6.0 GUARANTEE 7

PART V Standard specification HPCL, MUMBAI SECTION : 3.3 for Oil mist lubrication system SULPHUR BLOCK Page 3 of 7 Doc No.: 44LK-5100-704/M.02/0024/A4 44LK-5100 1.0 SCOPE This specification lists technical requirements for Closed loop oil mist lubrication system to be provided for the project. 2.0 GENERAL REQUIREMENTS 2.1 All pumps in unit, except forced/ pressurized lubricated pumps, shall be provided with closed loop oil mist lubrication system by the LSTK Contractor. 2.2 Centralized oil mist lubrication for all pumps and motors shall be provided. 2.3 All piping / tubing for conveying oil mist shall be of SS 304. 2.4 The system shall be provided suitable for the hazardous area classification. 2.5 All auxiliaries and instrumentation necessary for smooth and trouble free operation of the oil mist lubrication system shall be provided. 2.6 An closed-loop centralized lubrication system designed to produce, transport and deliver oil mist from a central console to supply bearing lubrication for the pumps and drivers shall be provided. 2.7 Oil mist system vendor to advise number of console/generators based on total number of users and plot layout. 2.8 The oil mist lubrication system provided by the contractor shall include the following as a minimum: - Console/Generator with auxiliary back-up unit and demisting apparatus - Microprocessor controller to monitor operating variables - Mist manifold (one for each pump) - Mist reclassifiers (one for each lubrication point) - Condensed oil mist collection container (one per equipment set) - Oil return header to route recovered oil to oil receiver - Hand pump for each condensed oil mist collection container to transfer collected oil to return header - Necessary piping for transfer of oil from hand pump to return header - Oil receiver of adequate capacity to hold oil recovered from all oil mist collection containers. Oil receiver shall be provided with drain arrangement to collect oil to be drained in portable containers. - Oil purification system including pump, filter and other necessary equipment. The system to be designed such that purified oil can be recycled to oil mist lubrication system.

HPCL, MUMBAI Standard specification PART V SULPHUR BLOCK for Oil mist lubrication system SECTION : 3.3 44LK-5100 Doc No.: 44LK-5100-704/M.02/0024/A4 Page 4 of 7 2.9 Console/Generator i) Console cabinet and oil reservoir (for main and auxiliary units) shall be constructed out of 304 SS. All console piping, tubing, tube fittings and mounting brackets shall be of 304 SS. ii) iii) iv) Console shall have a 304 SS sunscreen roof. No heating elements shall come into direct contact with the lubricating oil. The atomizing device, generator head, shall have an air bypass regulator to control mist density. v) The generator (mist) head shall provide 125% of the required airflow without exceeding the maximum capacity of the head. The head shall also be capable of proper misting operating down to 50% of rated flow. vi) vii) viii) vix) vx) vxi) The design of the mist head shall be such that its capacity can be changed without complete removal of the mist head from the console. Mist head shall include an air/oil heater. Console shall have an auxiliary back-up unit with the following: Oil mist generating capacity shall be equal to and of the same design as the main unit capable of operating independently from the main generating system provide a 10 micron oil filter easily accessible for maintenance. The oil reservoir of the main mist-generating chamber shall allow the system to operate for a minimum of 72 hours without refill. Oil reservoir shall include the following: - Level sight glass with normal operating level indicated - Fill connection with filtering screen - Tank vent - Low point drain - Low level probe - Temperature indicator - Pressure relief valve - Removable cover plate - Low point drain and valve - Low level alarm switch - Pressure gauge - Mist injection valve 2.10 Inlet Air System 2.10.1 The inlet air system shall include the following: Filter/moisture separator Pressure regulator 2.11 Instrumentation

PART V Standard specification HPCL, MUMBAI SECTION : 3.3 for Oil mist lubrication system SULPHUR BLOCK Page 5 of 7 Doc No.: 44LK-5100-704/M.02/0024/A4 44LK-5100 2.11.1 Oil mist vendor shall be responsible for supplying instrumentation to continuously monitor pressures, temperatures and oil levels. As a minimum the following variables shall be monitored: - Oil supply pressure - Supply air pressure - Regulated air pressure - Mist header pressure - Mist density - Air/oil temperature - Oil level in the mist-generating reservoir - Oil level in the bulk oil supply tank - Oil temperature in the bulk oil supply tank - Ambient temperature - The oil mist vendor shall provide a local control panel. Values for the above parameters shall be displayed on command on the panel. 2.12 Instruments and Safety Controls 2.12.1 Alarm switches for low discharge pressure, low oil reservoir level, and high filter differential pressure shall be provided. The switches shall be explosion-proof dual switches. The switches shall be closed (energized) during normal operation. The contractor shall provide for local or remote annunciation of oil system alarms. Contractor is also responsible for confirming that all system electrical components are suitable for the hazardous area classification. 2.12.2 An annunciator with manual reset sequence shall be furnished by the Purchaser and located in the local control panel. 2.12.3 Provide an auxiliary relay connected to a common trouble alarm located in the control center. This auxiliary relay shall be activated by all alarms. 2.13 Piping 2.13.1 All distribution piping and tubing shall be provided by EPC contractor. 2.13.2 Main headers shall be 2 inches (50 mm) galvanized steel pipe and shall not exceed 600 feet (180 meters) in length. The oil mist supply vendor shall insure that the time required for oil mist to reach the most distant point(s) on a header shall not exceed 5 minutes. 2.13.3 All headers shall be sloped continuously downward to the console at a minimum rate of 1/240. An auto drain leg shall be used when any portion of the header cannot be continuously sloped to the console due to obstructions. 2.13.4 There shall be no block valves in the header downstream of the switching valves that control the flow of mist from the mist generator. 2.13.5 Pockets shall be avoided. 2.13.6 Branch headers shall be 2 inch (50mm) stainless galvanized steel pipe. 2.13.7 Drop points shall be ¾ inch (19mm) stainless galvanized steel pipe and shall come off the top of the headers.

HPCL, MUMBAI Standard specification PART V SULPHUR BLOCK for Oil mist lubrication system SECTION : 3.3 44LK-5100 Doc No.: 44LK-5100-704/M.02/0024/A4 Page 6 of 7 2.13.8 Drop points shall be sloped downward towards the main or branch headers at the rate of 1/240. 2.13.9 Drop points shall terminate between 24 inches (60cm) and 48 inches (120cm) above and offset to the equipment to be lubricated. The drop leg should not interfere with access to the rotating equipment. 2.13.10 Drop points shall not have block valves. 2.13.11 Return header (for closed loop only) shall be parallel to and constructed of the same material as the main distribution header. 3.0 INSPECTION AND TESTING 3.1 All items and their parts shall be subjected to all mandatory tests and supplementary tests (wherever specified) and checks called for in the respective codes/standards/specification. 3.2 All items shall be stage wise inspected by 3 rd party inspection agency as per requirements 4.0 PACKING 4.1 All items shall be protected from rust, corrosion and mechanical damage during transportation, shipment, and storage, Rust preventive shall not be harmful to welding and shall be easily removable with a petroleum solvent. 4.2 End shall be suitably protected and the protectors shall be secured and tightly attached. 4.3 Part Nos are to be painted with an alkyd based paint. Lead based paints of stamping is prohibited. 4.4 Packing for imported items shall be seaworthy in wooden crates/cases with internal plastic envelopes and shall facilitate easy opening for dockside inspection. 5.0 DOCUMENTATION 5.1 AT OFFER STAGE Manufacturer s complete descriptive catalogue / literatures Accreditions/approvals of international agencies, for the subject item. List of deviations, the reasons thereof and the technical compatibility. 5.2 ALONGWITH DELIVERY Ten copies of manufacturer s Material Test Certificates (physical properties, chemical composition, heat treatment etc.) duty certified by inspection authority. Test support s for all mandatory as well as supplementary tests wherever specified. One soft copy on CD for all documents. 5.3 Any other drawings/document as required.

PART V Standard specification HPCL, MUMBAI SECTION : 3.3 for Oil mist lubrication system SULPHUR BLOCK Page 7 of 7 Doc No.: 44LK-5100-704/M.02/0024/A4 44LK-5100 6.0 GUARANTEE Vendor shall guarantee that all items supplied shall conform to the settled requirements in all respects. Any items found defective shall be replaced by the supplier at his on cost and without any delay.