Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

Similar documents
Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Specif ications. Minimum Surge Arrester Rating, kv

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

S&C Type XS Fuse Cutouts

S&C Type XS Fuse Cutouts

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Recloser Bypass Disconnects

T HREE-SHOT TYPE MZR F USE CUTOUT

S&C Loadbuster Disconnects

SPECIFICATION BULLETIN

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Disconnect & ByPass Switches

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

TYPE BLT DISCONNECT SWITCHES

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Figure 1. HX cutout fuseholders.

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.

Figure 1. HX cutout fuseholders. Positive Interruption

Installation and Operation

Specif ications. S&C Positrol Fuse Links. Outdoor Distribution

Technical Specification for Pole Mounted Capacitor Rack

Specifications. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

Type ICX Outdoor open type cutout

S&C Manual PME Pad-Mounted Gear

TYPE V CENTER BREAK SWITCH

POWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS

Catalog 14A January 2013

Installation. Loadbuster The S&C Loadbreak Tool Outdoor Distribution (14.4 kv through 34.5 kv) Table of Contents. Instruction Sheet

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Technical Specification For Outdoor Substation Harmonic Filter Banks

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

Electronic Resettable Sectionalizer

K-Limiter high ampere Companion II fuse

شركة كهرباء محافظة القدس المساهمة المحدودة

Q pole Pole Mounted Capacitor System

Specifications. S&C Source-Transfer PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) With Micro-AT Control. Conditions of Sale

OVERHEAD SERVICE. Items to consider

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

JUMPERS & SWITCHING TOOLS

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Underground Distribution Switchgear

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

3.0OVERHEAD TRANSMISSION SWITCHES

M-Force three-phase switch

M-Force three-phase switch

34-SDMS-01 SPECIFICATIONS FOR

43-SDMS-01 SPECIFICATIONS FOR

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 15 DPL Building Courthouse Plaza Southwest Dayton, Ohio P.U.C.O. NO. 1

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Specifications. S&C Switch Operators Types AS-1A and AS-10a. Conditions of Sale

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

D-73P disconnect and bypass switches

Easy-On II Terminations

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

OVERHEAD DISTRIBUTION SWITCHES

Copper Double Break Switch

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

Molded Current-Limiting Fuse

S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, SMD-3, and SMD-50. Outdoor Transmission (34.5 kv through 138 kv)

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Medium Voltage Fuses

Industrial Control Transformers

PROTECTION AND CONTROL

GROUP D. Switch & Protective device.

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

045 : 2000 CEB STANDARD

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

GENERAL. CONSTRUCTION External

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Instructions for Installation

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Jumpers & Load Pickup Tools

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Typical Specification

Transcription:

Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS below. SPECIAL TO THIS PODUCT: INCLUSIONS: S&C Type XS Fuse Cutouts are assigned single-value nominal voltage ratings (not dual, slant, or system voltage class ratings) and are applicable, without restriction, on all three-phase systems having system maximum operating voltage (line-to-line) less than or equal to the cutout maximum voltage. Type XS Cutout interrupting ratings have been substantiated by testing performed in accordance with IEEE C37.41-2000. ecognizing that under certain fault conditions cutouts can be exposed to voltages in excess of system line-to-neutral voltage faults the cutouts should clear with no reliance on backup devices S&C has tested Type XS Cutouts at full system line-to-line voltage across a wide spectrum of available fault currents using transient-recovery voltages realistically representative of those the cutout will see in actual service. A choice of connector arrangements is available some at an extra charge as listed in the table Specify the connector arrangement desired by adding the appropriate suffix letter to the catalog number of the selected cutout. All S&C Type XS Fuse Cutouts and Disconnects listed are equipped with hooks for use with Loadbuster the S&C Loadbreak Tool. EXCLUSIONS: Overhead pole-top style cutouts do not include fuse links or mounting brackets. Mounting brackets for these cutouts are available, at an extra charge, as listed in the table WAANTY QUALIFICATIONS: The standard warranty contained in seller s standard conditions of sale (as set forth in Price Sheet 153) does not apply to S&C Type XS Fuse Cutouts Outdoor Distribution when installed in conjunction with fuse tubes or disconnect blades of other than S&C manufacture, nor does it apply to S&C fuse tubes and disconnect blades installed in cutouts of other than S&C manufacture. How to Order A Complete Type XS Fuse Cutout 1. Obtain the catalog number of the desired fuse cutout from the table on pages 2 and 3. 2. Select mounting bracket (if desired), connector arrangement (required), and other options (if desired) from the tables Add the indicated suffix letter(s) to the catalog number selected in Step 1, above. How to Order Handling Tools Obtain the catalog number(s) of recommended handling tool(s) from the table efer to Specification Bulletin 851-31. S&C Type XS Fuse Cutouts are manufactured in accordance with a quality system certified to ISO 9001:2000. Single-shot Overhead Pole-Top Style Type XS Fuse Cutouts are sold in the United States, Canada, and all countries in the Caribbean (excluding countries located on the mainland of South America and Central America) by MacLean Power Systems, www.macleanpower.com. Also applicable on 26.4- through 34.5- systems for protection of single-phase-to-neutral circuits (lines or transformers) only and grounded-wye connected capacitor banks in solidly grounded-neutral (multigrounded-neutral) systems. For fuse cutouts to be used on a 36- system, contact your nearest S&C Sales Office. November 9, 2015 S&C Electric Company 1999-2015, all rights reserved Specification Bulletin 351-31

Complete Units Style and Illustration System Voltage, Extra-Heavy-Duty Overhead Pole-Top2 4.16 thru 14.4 Amperes, MS Interrupting, Asym. Leakage Distance to Ground Minimum, Inches (mm) and Connectors)1 Page eference for Dimensional Information 14.4 15 110 100 10 000 8½ (216) 143/4 (375) 8902110 8902110-P 6 25 27 125 100 8 000 11 (279) 8902210 6 150 100 8 000 17 (432) 19 (480) 8904210 8904210-P 7 16.5 thru 24.9 25 27 125 100 8 000 11 (279) 8902210 6 150 100 8 000 17 (432) 19 (480) 8904210 8904210-P 7 26.4 thru 34.5 25 27 150 100 8 000 17 (432) 19 (480) 8904210 8904210-P 7 Ultra-Heavy-Duty Overhead Pole-Top3 4.16 thru 14.4 14.4 15 25 27 110 100 16 000 8½ (216) 143/4 (375) 8903110 8903110-P 8 110 200 12 000 8½ (216) 143/4 (375) 8907111 8907111-P 10 125 100 12 000 11 (279) 8903210 8 150 100 12 000 17 (432) 19 (480) 8905210 8905210-P 9 25 27 125 100 12 000 11 (279) 8903210 8 125 200 10 000 11 (279) 8907211 10 16.5 thru 24.9 150 100 12 000 17 (432) 19 (480) 8905210 8905210-P 9 25 27 150 200 10 000 17 (432) 19 (480) 8909211 8909211-P 11 150 100 12 000 17 (432) 8903310 26.4 thru 34.5 25 27 150 100 12 000 17 (432) 19 (480) 8905210 8905210-P 9 150 100 12 000 17 (432) 8903310 26.4 thru 34.5 25 27 150 100 12 000 26 (660) 357/16 (900) 8905310 8905310-P 9 suffix letter(s) to catalog number. For example, 8903110-BD. See table 2 Uses either nonremovable or removable buttonhead fuse links. 3 Uses removable buttonhead fuse links only. Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly grounded-neutral (multigrounded-neutral) systems where the leakage distance to ground meets user s requirements. Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly grounded-neutral (multigrounded-neutral) systems. For use on a 36- system, contact your nearest S&C Sales Office. One-shot rating, based on replacement of cutout tube only. Approximate fuse-tube length, top of fuse-tube cap to bottom of fuse tube: 14¾ inches (375 mm). Approximate fuse-tube length, top of fuse-tube cap to bottom of fuse tube: 18¼ inches (464 mm). Leakage distance to ground is 26 inches (660 mm) for catalog numbers 8905310 and 8925310, 28.3 inches (720 mm) leakage distance also available, contact your nearest S&C Sales Office. Product discontinued. Meets 170- BIL rating requirement of IEC Publication 282-2. TABLE CONTINUED 2 S&C Specification Bulletin 351-31

Complete Units Continued Style and Illustration System Voltage, Amperes, MS Mom., Asym. Leakage Distance to Ground Minimum, Inches (mm) and Connectors)1 Page eference for Dimensional Information Disconnect Overhead Pole- Top 4.16 thru 14.4 14.4 15 110 300 16 000 8½ (216) 143/4 (375) 8922110 8922110-P 12 25 27 125 300 12 000 11 (279) 8922210 12 16.5 thru 24.9 25 27 125 300 12 000 11 (279) 8922210 12 150 300 12 000 17 (432) 8922310 26.4 thru 34.5 25 27 150 300 12 000 17 (432) 8922310 26.4 thru 34.5 25 27 150 300 12 000 26 (660) 357/16 (900) 8925310 8925310-P 13 suffix letter(s) to catalog number. For example, 8903110-BD. See table Applicable where the leakage distance to ground meets user s requirements. For cutouts to be used on 36- system, contact your nearest S&C Sales Office. 28.3 inches (720 mm) leakage distance is also available; contact your nearest S&C Sales Office. Product discontinued. Meets 170- BIL rating requirement of IEC Publication 282-2. S&C Specification Bulletin 351-31 3

Mounting Brackets and Connector Options Item Add Catalog Number Suffix S&C Extended Mounting Bracket for crossarm, pole, or wall mounting of overhead pole-top style cutouts -B NEMA Type B Mounting Bracket for crossarm mounting of overhead pole-top style cutouts -C Item Quantity Accommodating Conductors Size and Material Position Parallel-Groove Connectors Two No. 6 solid (13.3 mm 2 ) through No. 2 stranded (44.4 mm 2 ) copper or aluminum in one groove; No. 2 solid (33.6 mm 2 ) through 250 kc mil (168 mm 2 ) stranded copper or aluminum or 4/0 ACS (161 mm 2 ) in the other groove Standard Orientation -D Eye-Bolt Connectors One No. 8 solid (8.4 mm 2 ) through 250 kc mil (168 mm 2 ) stranded copper or aluminum, or 4/0 ACS (161 mm 2 ) Standard Orientation Lower Connector otated 90 -M -M90 Other Options Item Add Catalog Number Suffix Sea-Coast Design all galvanized steel components and hardware replaced with stainless steel to provide enhanced corrosion resistance in coastal or high contamination environments1 -S 1 Special order. Available only for porcelain insulators. ecommended Handling Tools For use with Type XS Fuse Cutouts Item Catalog Number Station Prong 44022 Distribution Prong 4416 Talon Handling Tool 4440 Universal Pole Select to match height of installation. efer to Specification Bulletin 851-31. 4 S&C Specification Bulletin 351-31

Mounting Bracket Details 211 16 TO 4 MAX (68 TO 102 MAX) 3/8 (10) 413/16 (122) 41/8 TO 51/8 MAX (105 TO 130 MAX) 11/8 (29) 17/32 (13.5) SQUAE 43/8 (111) 71/2 41/2 (191) (114) 31/4 (83) 11/16 (17.5) DIA. HOLE 7/16 (11) SQUAE 11/8 (29) SEE DETAIL AT IGHT 11/8 (29) 2 (51) 1 (25) S&C Extended Mounting Bracket ( Suffix -B ) Adjustable from 3 4 to 4 5 (76 102 to 102 127) Crossarm 211 16 TO 4 MAX (68 TO 102 MAX) 3/8 (10) 21/4 (57) 41/8 TO 51/8 MAX (105 TO 130 MAX) 17/32 (13.5) SQUAE 3/4 (19) 21/4 (57) 71/2 (191) 41/2 (114) 31/4 (83) 11/16 (17.5) DIA. HOLE 7/16 (11) SQUAE SEE DETAIL AT IGHT 7/8 (22) NEMA Type Mounting Bracket ( Suffix -C ) Adjustable from 3 4 to 4 5 (76 102 to 102 127) Crossarm 13/4 (44) S&C Specification Bulletin 351-31 5

Extra-Heavy-Duty Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. Q M S 17/32 (13.5) DIA. HOLE X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 s 8902110 and 8902210 Uses either nonremovable or removable buttonhead fuse links. Amperes, MS Interr., Asym Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 14.4 15 110 100 10 000 81/2 (216) 8902110 14.4 15 110 100 10 000 143/4 (375) 8902110-P 25 27 125 100 8 000 11 (279) 8902210 suffix letter(s) to catalog number. For example, 8902110-BD. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. Dimensions in Inches (mm) M N Q2 S3 T W X4 17 (432) 17 (432) 197/8 201/4 (514) 201/4 (514) 121/2 (318) 121/2 (318) 131/8 (333) 93/4 (248) 93/4 (248) 23/8 (60) 23/8 (60) Net Weight, Lbs. (kg) 13 (5.9) 81/2 (3.9) 151/2 (7.0) 4 Dimension applies to cutout furnished with optional NEMA Type B Mounting Bracket (cutout Suffix -C ). If cutout is furnished Number Suffix -B ), dimension is 11/8 inches (29 mm). 6 S&C Specification Bulletin 351-31

Extra-Heavy-Duty Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. S Q 17/32 (13.5) DIA. HOLE M X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 8904210 Uses either nonremovable or removable buttonhead fuse links. Amperes, MS Interr., Asym Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 suffix letter(s) to catalog number. For example, 8904210-BD. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. 25 27 150 100 8 000 17 (432) 8904210 Dimensions in Inches (mm) M N Q2 S3 T W X4 197/8 25 27 150 100 8 000 19 (480) 8904210-P 197/8 131/8 (333) 131/8 (333) Net Weight, Lbs. (kg) 201/2 (9.3) 10 (4.5) 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems rated 26.4 through 34.5 where leakage distance to ground meets user s requirements. S&C Specification Bulletin 351-31 7

Ultra-Heavy-Duty Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. Q M S 17/32 (13.5) DIA. HOLE X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 s 8903110 and 8903210 Uses removable buttonhead fuse links only. Amperes, MS Interr., Asym Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 14.4 15 110 100 16 000 81/2 (216) 8903110 14.4 15 110 100 16 000 143/4 (375) 8903110-P 25 27 125 100 12 000 11 (279) 8903210 suffix letter(s) to catalog number. For example, 8903110-CM. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. Dimensions in Inches (mm) M N Q2 S3 T W X4 17 (432) 17 (432) 197/8 201/4 (514) 201/4 (514) 121/2 (318) 121/2 (318) 131/8 (333) 93/4 (248) 93/4 (248) 23/8 (60) 23/8 (60) Net Weight, Lbs. (kg) 13 (5.9) 81/2 (3.9) 151/2 (7.0) 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). 8 S&C Specification Bulletin 351-31

Ultra-Heavy-Duty Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. Q M S 17/32 (13.5) DIA. HOLE X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 s 8905210 and 8905310 Uses removable buttonhead fuse links only. Amperes, MS Interr., Asym Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 25 27 150 100 12 000 17 (432) 8905210 25 27 150 100 12 000 19 (480) 8905210-P 25 27 150 100 12 000 26 (660) 8905310 suffix letter(s) to catalog number. For example, 8905210-CM. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). Dimensions in Inches (mm) M N Q2 S3 T W X4 197/8 197/8 223/4 (578) 25 27 150 100 12 000 357/16 (900) 8905310-P 223/4 (578) 313/8 (797) 313/8 (797) 133/4 (349) 133/4 (349) 133/4 (349) 133/4 (349) 91/2 (241) 91/2 (241) 13 (330) 13 (330) Meets 170 BIL rating requirement of IEC Publication 282-2. Net Weight, Lbs. (kg) 201/2 (9.3) 10 (4.5) 23 (10.4) 12 (5.5) Approximate fuse-tube length, top of fuse-tube cap to bottom of fuse tube: 143/4 inches (375 mm). Approximate fuse-tube length, top of fuse-tube cap to bottom of fuse tube: 181/4 inches (464 mm). Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems rated 26.4 through 34.5 where leakage distance to ground meets user s requirements. S&C Specification Bulletin 351-31 9

Ultra-Heavy-Duty Overhead Pole-Top Style Q OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. S M 17/32 (13.5) DIA. HOLE X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 s 8907111 and 8907211 Uses removable buttonhead fuse links only. Amperes, MS Interr., Asym Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 Dimensions in Inches (mm) Net Weight, Lbs. (kg) 14.4 15 110 200 12 000 81/2 (216) 8907111 14.4 15 110 200 12 000 143/4 (375) 8907111-P 25 27 125 200 10 000 11 (279) 8907211 suffix letter(s) to catalog number. For example, 8907111-CD. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). M N Q2 S3 T W X4 17 (432) 17 (432) 197/8 201/4 (514) 201/4 (514) 121/2 (318) 121/2 (318) 131/8 (333) 93/4 (248) 93/4 (248) 23/8 (60) 23/8 (60) 14 (5.9) 91/2 (4.3) 161/2 (7.5) 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). 10 S&C Specification Bulletin 351-31

Ultra-Heavy-Duty Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. Q 17/32 (13.5) DIA. HOLE M S X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 8909211 Uses removable buttonhead fuse links only. Amperes, MS Interr., Asym Leakage Distance to Ground, Min., Inches (mm) suffix letter(s) to catalog number. For example, 8909211-CD. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). and Connectors)1 Dimensions in Inches (mm) Net Weight, Lbs. (kg) 25 27 150 200 10 000 17 (432) 8909211 M N Q2 S3 T W X4 197/8 25 27 150 200 10 000 19 (480) 8909211-P 197/8 131/8 (333) 131/8 (333) 2 (9.8) 11 (5.0) 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). S&C Specification Bulletin 351-31 11

Disconnect Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. Q M S 17/32 (13.5) DIA. HOLE X 5/16 (8) T N OPTIONAL PAALLEL-GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 20 s 8922110 and 8922210 Amperes, MS Short Time Mom., Asym 15-Cycle (Sym.) Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 14.4 15 110 300 16 000 10 600 81/2 (216) 8922110 14.4 15 110 300 16 000 10 600 143/4 (375) 8922110-P 25 27 125 300 12 000 8 600 11 (279) 8922210 suffix letter(s) to catalog number. For example, 8922110-BD. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). Dimensions in Inches (mm) M N Q2 S3 T W X4 17 (432) 17 (432) 197 8 201/4 (514) 201/4 (514) 121/2 (318) 121/2 (318) 131/8 (333) 93/4 (248) 93/4 (248) 23 8 (60) 23 8 (60) Net Weight, Lbs. (kg) 13 (5.9) 81/2 (5.9) 151/2 (7.0) 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). 12 S&C Specification Bulletin 351-31

Disconnect Overhead Pole-Top Style OPTIONAL MOUNTING BACKET (CATALOG NUMBE SUFFIX -B O -C ). SEE PAGE 4. S Q 17/32 (13.5) DIA. HOLE M X 5/16 (8) T N 20 OPTIONAL PAALLEL- GOOVE CONNECTO (CATALOG NUMBE SUFFIX -D ). SEE PAGE 4. W 8925310 Amperes, MS Short Time Mom., Asym 15-Cycle (Sym.) Leakage Distance to Ground, Min., Inches (mm) and Connectors)1 suffix letter(s) to catalog number. For example, 8925310-BD. See table 2 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 53/16 inches (132 mm). 25 27 150 300 12 000 8 600 26 (660) 8925310 Dimensions in Inches (mm) M N Q2 S3 T W X4 223/4 (578) 25 27 150 300 12 000 8 600 357/16 (900) 8925310-P 223/4 (578) 313/8 (797) 313/8 (797) 133/4 (349) 133/4 (349) 91/2 (241) 91/2 (241) 13 (330) 13 (330) 3 Dimension applies to cutout furnished with optional parallel-groove connectors (cutout Suffix -D ). If cutout is furnished with optional eye-bolt connectors (cutout Suffix -M ), dimension is slightly smaller. 4 Dimension applies to cutout furnished with optional NEMA Type B Number Suffix -B ), dimension is 11/8 inches (29 mm). Meets 170- BIL rating requirement of IEC Publication 282-2. Net Weight, Lbs. (kg) 23 (10.4) 12 (5.5) S&C Specification Bulletin 351-31 13

Parts for Type XS Cutout Item Basic Catalog Number Presently ated,, Nom.1 Previously ated,, Nom.2 Leakage Distance to Ground, Minimum, Inches (mm) Approx. Fuse Tube Length,3 Inches (mm) Amperes, Cont. and Connectors)4 Overhead Pole- Top Cutout, less Fuse Tube Extra-Heavy- Duty Fuse Tube, including cap Ultra-Heavy- Duty Fuse Tube, including cap and arc-shortening rod Spare Disconnect Blade 89021 89031 89071 89221 89022 89032 89072 89222 89042 89052 89092 89033 89223 89053 89253 14.4 25 25 7.2, 7.2/14.4 14.4, 14.4/25 14.4, 14.4/25 81/2 (216) 143/4 (375) 111/4 (286) 8981110 8981110-P 11 (279) 143/4(375) 8981210 17 (432) 19 (480) 143/4 (375) 8980210 8980210-P 25 25 17 (432) 181/4 (464) 8981310 25 26 (660) 357/16 (900) 181/4 (464) 8982310 8982310-P 89021 14.4 7.2/14.4 81/2 (216) 14¾ (375) 111/4 (286) 100 8952110 89022 89042 25 14.4 11 (279) 17 (432) 19 (480) 143/4 (375) 100 8952210 89031 14.4 7.2/14.4 81/2 (216) 14¾ (375) 111/4 (286) 100 8953110 89032 89052 89033 89053 25 14.4/25 25 25 11 (279) 17 (432) 17 (432) 26 (660) 19 (480) 357 16 (900) 143/4 (375) 100 8953210 181/4 (464) 100 8953310 89071 14.4 7.2 81/2 (216) 14¾ (375) 111/4 (286) 200 8957111 89072 89092 25 14.4 11 (279) 17 (432) 19 (480) 143/4 (375) 200 8957211 89221 14.4 7.2/14.4 81/2 (216) 14¾ (375) 111/4 (286) 300 8962110 89222 25 14.4/25 11 (279) 143/4 (375) 300 8962210 89223 89253 25 25 17 (432) 26 (660) 1 Cutouts having catalog number supplement -11, -10, -9, 8, or -7. For example, 8902110-BD. 2 Cutouts having catalog number supplement -6 or lower. For example, 890215-BD. 3 From top of fuse-tube cap to bottom of fuse tube. 357 16 (900) 181/4 (464) 300 8962310 4 Specify mounting bracket, if desired, and connector option by adding suffix letter(s) to catalog number. For example, 8981110-BD. See table Product discontinued. 14 S&C Specification Bulletin 351-31