Specif ications. S&C Positrol Fuse Links. Outdoor Distribution

Similar documents
www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

SPECIFICATION BULLETIN

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Specif ications. Minimum Surge Arrester Rating, kv

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts)

G B C, P l u g - i n F u s e

Input Current (Amps) Input Power (ANSI Watts)

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Input Current (Amps) Input Power (ANSI Watts)

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Specifications. S&C Switch Operators Types AS-1A and AS-10a. Conditions of Sale

Input Power (Watts) (min/max)

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

K-Limiter high ampere Companion II fuse

ICN2S40N35I Ele Ballast (2) F40T V

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

Input Current (Amps) Input Power (ANSI Watts)

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Input Power (Watts) (min/max)

C308F 3 mm x 8.4 mm fast-acting, ceramic tube fuses for hazardous applications

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Low-Peak 600V Class RK1

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Input Power (Watts) (min/max)

Transporter Current Flow Diagram No. 671 / 1 Edition

Specifications. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Input Power (Watts) (min/max)

SUBMERSIBLE SECONDARY CONNECTORS

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

AMP MCP Interconnection System AMP MCP 6.3/4.8K Contact System

Application of Primary Fuses

2010 Irrigation Products Illustrated Parts Breakout

S&C Recloser Bypass Disconnects

RELB2S40N35I (2)F40T12 120V Ele BLST

Specifications. S&C Source-Transfer PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) With Micro-AT Control. Conditions of Sale

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

FUSE & CIRCUIT PROTECTION

Service and installation must be performed by a trained/experienced service technician.

Special Purpose Fuses

S&C Loadbuster Disconnects

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

HM SERIES. (Outdated connector) Features P-01

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Figure 1. HX cutout fuseholders. Positive Interruption

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

NEOZED D0 fuse-links gg 400/440VAC

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

Advanced Instructions

LAB 7. SERIES AND PARALLEL RESISTORS

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

INTERFACE PART NUMBER NOTES

Generator Quick Connection Tap Box WM Series

General Purpose IEC Fuses

Midget & Electronic Fuses

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding

Installation and Operation

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

8.3kV, 9.9kV, 15.5kV, 17.2kV and 23kV Cooper ELSP Backup Fuses Testing per C

Molded Current-Limiting Fuse

Swagelok Alternative Fuel Ser vice (AFS) Ball Valves

2004 Scion xa. PARKING LIGHTS (+) GREEN At Harness On Top Of Fuse Box DOOR TRIGGER (-) RED/WHITE In 9-Pin On Top Of Fuse Box

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Quick Reference Performance Guide

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

Type ICX Outdoor open type cutout

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

S&C Manual PME Pad-Mounted Gear

Technical Specification For Outdoor Substation Harmonic Filter Banks

CF5X P/N _J NSF. Certified. Technical Data Sheet. October Scan QR code to access product information on your mobile device.

UNIVERSAL WIRING HARNESS Installation Manual

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

SMGT Technical Data Sheet

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

TYPE-CERTIFICATE DATA SHEET

Passat Current Flow Diagram No. 46 / 1 Edition

Pole-mounted capacitor racks with single-phase capacitor units

Transcription:

S&C Positrol Fuse Links Outdoor Distribution Specif ications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: SPECIFICATION NOTES: S&C QR Speed Positrol Fuse Links in both the Universal and Extra-Performance Styles are interchangeable mechanically and with respect to time-current characteristics with Kearney Type QA fuse links. How to Order Positrol Fuse Links Obtain the catalog number of the fuse link in the desired style and rating. Note: Fuse links in ratings through 100 amperes are sold in packs of 5 or overpacks of 25. Minimum ordering quantity is 5. Fuse links in ratings greater than 100 amperes are sold in packs of 1 or overpacks of 5. Minimum ordering quantity is 5. All S&C Positrol Fuse Links have removable button heads to accommodate cutout fuse tubes with arc-shortening rods. SPECIFICATION DEVIATIONS: Special length fuse links cannot be supplied. S&C Positrol Fuse Links are manufactured in accordance with a quality system certified to ISO 9001, and they are Rural Utilities Service (RUS) accepted. April 21, 2014 S&C Electric Company Specification Bulletin 352-31

S&C Positrol Fuse Links Fuse Links, Universal Style Not Usable in Positect S&C Standard Speed1 (TCC No. 123-6) S&C K Speed2 (TCC No. 165-6) S&C T Speed3 (TCC No. 170-6) S&C QR Speed45 (TCC No. 166-6) Rating, Amperes 23-Inch (584 mm) Overall Length Rating, Amperes 23-Inch (584 mm) Overall Length Rating, Amperes 23-Inch (584 mm) Overall Length Rating, Amperes 23-Inch (584 mm) Overall Length 1 64001R1 1QR 338001R1 2 64002R1 2QR 338002R1 3 64003R1 3QR 338003R1 5 64005R1 5QR 338005R1 6K 265006R1 6T 279006R1 7 64007R1 7QR 338007R1 8K 265008R1 8T 279008R1 8QR 338008R1 10 64010R1 10K 265010R1 10T 279010R1 10QR 338010R1 12K 265012R1 12T 279012R1 15 64015R1 15K 265015R1 15T 279015R1 15QR 338015R1 20 64020R1 20K 265020R1 20T 279020R1 20QR 338020R1 25 64025R1 25K 265025R1 25T 279025R1 25QR 338025R1 30 64030R1 30K 265030R1 30T 279030R1 30QR 338030R1 40 64040R1 40K 265040R1 40T 279040R1 40QR 338040R1 50 64050R1 50K 265050R1 50T 279050R1 50QR 338050R1 60QR 338060R1 65 64065R1 65K 265065R1 65T 279065R1 75QR 338075R1 80 64080R1 80K 265080R1 80T 279080R1 100 64100R1 100K 265100R1 100T 279100R1 100QR 338100R1 125 64125R2 125QR 355125R1 140K 265140R2 140T 279140R1 150 64150R2 150QR 355150R1 175QR 355175R1 200 64200R2 200K 265200R2 200T 279200R1 200QR 355200R1 1 These fuse links replace obsolete S&C Extra-Performance Style Fuse Link s 334XXX. 2 These fuse links replace obsolete S&C Extra-Performance Style Fuse Link s 335XXX. 3 These fuse links replace obsolete S&C Extra-Performance Style Fuse Link s 336XXX. 4 These fuse links replace obsolete S&C Extra-Performance Style Fuse Link s 337XXX for ratings through 100 amperes and s 356XXX for ratings above 100 amperes. 5 These fuse links are interchangeable mechanically and with respect to time-current characteristics with Kearney Type QA fuse links. For optional cable adapters for use with S&C QR Speed fuse links, see table on page 5. For use in 200-ampere cutouts. The 1-, 2-, and 3-ampere S&C Standard Speed Positrol Fuse Links meet requirements for coordination with fuse links rated 6K and 6T amperes as specified in ANSI Standard C37.42, and are recommended for use in K and T Speed fuse-link coordination schemes. 2 S&C Specification Bulletin 352-31

S&C Positrol Fuse Links Fuse Links, Universal Style Not Usable in Positect S&C N Speed1 (TCC No. 167-6) Fuse Links, Universal Style Not Usable in Positect S&C Coordinating Speed (TCC No. 172-6) 5N 8N 10N 15N 20N 25N 30N 40N 45N 50N 65N 75N 85N 95N 100N 125N 150N 200N 23-Inch (584 mm) Overall Length 267005R4 267008R4 267010R4 267015R4 267020R4 267025R4 267030R4 267040R4 267045R4 267050R4 267065R4 267075R4 267085R4 267095R4 267100R4 267125R4 267150R4 267200R4 1 These fuse links are interchangeable (with respect to time-current characteristics) with discontinued GE Models 9F1C and 9F51AAN series fuse links. For use in 200-ampere cutouts. 23-Inch (584 mm) Overall Length 101 179101R1 102 179102R1 103 179103R1 For use in 100-ampere cutouts. Fuse Links, Universal Style Not Usable in Positect S&C QR Speed1 (TCC No. 166-6A) 23-Inch (584 mm) Overall Length 125 QR 338125R1 150 QR 338150R1 1 These fuse links are interchangeable mechanically and with respect to time-current characteristics with Kearney Type QA fuse links. For optional cable adapters for use with S&C QR Speed fuse links, see table on page 5. For use in 100-ampere cutouts. S&C Specification Bulletin 352-31 3

S&C Positrol Fuse Links Fuse Links, Universal Style Usable in Positect S&C Standard Speed (TCC No. 123-6) Fuse Links, Indicating Style Usable in Positect Only S&C Standard Speed (TCC No. 123-6) 23-Inch (584 mm) Overall Length 1 364001 2 364002 3 364003 5 364005 7 364007 10 364010 15 364015 20 364020 25 364025 30 364030 40 364040 50 364050 65 364065 80 364080 100 364100 10-Inch (254 mm) Overall Length 3 115003 5 115005 7 115007 10 115010 15 115015 20 115020 25 115025 30 115030 40 115040 50 115050 65 115065 80 115080 100 115100 Fuse Links Open Style S&C Standard Speed (TCC No. 123-6) 8-Inch (203 mm) Fuse Links, Universal Style Usable in Positect S&C Y Speed (TCC No. 158-6) 135 Y 364100-S100 1 77401 2 77402 3 77403 5 77405 7 77407 10 77410 15 77415 20 77420 25 77425 4 S&C Specification Bulletin 352-31

S&C Positrol Fuse Links Adapters for S&C QR Speed Positrol Fuse Links (Universal Style)1 Description Add Suffix to of Link Fuse Link Cable Adapter -U 1 QR 100 QR 125 QR 150 QR 1 For adapting fuse link for use in cutouts having bolt-type connections for upper and lower fuse-link cables. Overall length of all QR Speed Positrol Fuse Links equipped with suffix -U cable adapter is 23 inches (584 mm). Optional Features Item Add Suffix to of Link Style1 Fuse Link Cable Adapter and Color-Coded Ampere Rating Flag23 Extra-Long Cable (Provides 29 inches (737 mm) Overall Fuse Link Length) -S100 Universal -L29 Universal 1 5 6K 100K 6T 100T 1 200 6K 200K 6T 200T 1QR 200QR 5N 200N 101 Coord 103 Coord 1 Not usable in Positect. 2 For adapting fuse link for use in cutouts having bolt-type connections for upper and lower fuse-link cables. 3 Flag colors for Standard Speed fuse links are as follows: 1 Brown, 2 Red, 3 Orange, 5 Yellow. Flag colors for T and K Speed fuse links are as follows: 6T and 6K Tan, 8T and 8K Green, 10T and 10K Blue, 12T and 12K Pink, 15T and 15K Violet, 20T and 20K Gray, 25T and 25K Clear, 30T and 30K White, 40T and 40K Black, 50T and 50K Silver, 65T and 65K None, 80T and 80K None, 100T and 100K None. S&C Specification Bulletin 352-31 5

Printed in U.S.A.