RP1 TWISTER. Micro Air Installation and Operation Manual

Similar documents
Model SD23, SD34, SD46, SD48 Operator s Manual INSPECTION: The Superior table is shipped on one skid. This skid should be inspected for any visible

MICRO-AIR DUST COLLECTOR Installation and Operation Manual MODEL RP6-2, RP-3, RP8-2 & RP-3

XA46 Max. Installation and Operation Manual

XA34 Max. Installation and Operation Manual

MC2500. Installation and Operation Manual

MODEL WC2500 Installation and Operation Manual Important:

MODEL WC1200 Installation and Operation Manual Important:

MODEL MC1500 Installation and Operation Manual Important:

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

MODEL SCA Installation and Operation Manual Important:

MODEL MA4210 Installation and Operation Manual Important:

SUPERIOR PERFORMANCE

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

DUST COLLECTORS. Stronger. Better. CLEANER.

Air Boss CA3000C & CA6000C. Installation Operation Maintenance Manual. Cartridge Air Cleaners

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

High Pressure Abrasive Blast Cabinet 42000

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION

Empire Abrasive Equipment Company

Horizontal downflow pleated cartridge dust collector

Installation & Service Manual for Horizontal Cartridge Filtration Systems

Affordable portable filtration unit

Empire Abrasive Equipment Cartridge Filter Collector EM 2-2 and EM 2-4

Owner s manual for installation, usage and maintenance

Torit PowerCore CPC-3, -4, -6, -8, -12, -16, -24, -32, -40 and -48 Hopper Inlet After November 2008

CA3000C & CA6000C Cartridge Air Cleaners

OWNER S MANUAL DOWNWARD FLOW CARTRIDGE DUST COLLECTOR MODEL: SFC PATENT NO:

Supra-Blast Cartridge Dust Collector Installation and Operation Manual

Empire Finish & Reclaim Cabinets. Cabinet Models Options EFR-2636 SRC. Parts Cabinet Assembly Reclaimer Dust Bag Dust Collector Pipe String Blast Gun

PHOENIX MINI-GUARDIAN

FJS Continuous Cleaning Cartridge Series Installation and Operation Manual

Torit PowerCore VH 1-4, 1-6, 2-8, 2-12, 2-16, 3-18, Installation and Operation Manual Installation, Operation, and Service Information

Cabinet Collector Series Models 54, 64, 66, 75, 81, 84, 90

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

Torit PowerCore VH 1-4, 1-6, 2-8, 2-12, 2-16, 2-20, 3-18, 3-24, 3-30 VL 1-4, 1-6, 2-8, 2-12, 2-16, 2-20, 3-18, 3-24, 3-30

Owner s manual for installation, usage and maintenance

IMPORTANT SAFETY INSTRUCTIONS

Horizontal downflow pleated cartridge dust collector

THE MAGNUM SUCTION SYSTEM

COMPACT MEDIA DUST COLLECTOR BDC SERIES

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

Modular Baghouse Top Access MBT and MBTH

MIMPEN0410. Installation, operation and maintenance manual DMP-170, DMP-170S, DMP-270, DMP-270S, DMP-350, DMP-350S, DMP-450 & DMP-450S

Installation and Operation Manual

Installation & Service Manual for Portable Fume Collector. Model PFC-800

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

Downflo II DFT 2-4 and 3-6 (Units Built After July 2003)

Installation and Operation Manual

OWNER'S MANUAL. CL3000 Series. Installation and Service Manual

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

Torit PowerCore TGP. Installation and Operation Manual Installation, Operation, and Service Information TG4 TG12

WITH 300 CFM RECLAIM MANUAL NUMBER: 563 TABLE OF CONTENTS

Torit PowerCore CPV-1, -2, -3, -4, -6, -8, and -12 After November 2008

FROM A LEADER IN CLEAN AIR TECHNOLOGY

CONTENTS 2. NOTICE 3 3. SET UP 4 8. CABINET PART DRAWING 9,10 9. ERGO CABINET PLUMBING 11,12, DUAL REMOTE CONTROL VALVE 14,15

AIR CLEANERS. Model MX 1800 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

RPH Reverse-Pulse Dust Collectors Models RPH-2, 3, 4, 6, and 8 O. M

OWNER'S MANUAL. OX1100 Series. Installation and Service Manual

TD Collector TD-162 and TD-573

Bin Vent TBV-2, TBV-4 and TBV-6

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

ON DEMAND INSTALLATION GUIDE

Installation and Operation Manual

OWNER S MANUAL. OX3500C Series. Installation and Service Manual

PRESSURE CABINETS PROBLEM CAUSE SOLUTION

WSO Mist Collector WSO 20, 25-1, 25-2 and 25-3

downflo workstation dust collectors

Installation and Operation Manual

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Installation and Operation Manual

RPC-2 REVERSE PULSE DUST COLLECTOR

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

ASSEMBLY INSTRUCTIONS FOR JACKETED FILTER REACTOR SYSTEMS

Torit PowerCore CPV-After November 2008

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

COMPRESSED AIR LOADER MODEL: AL-1

OWNER S MANUAL. Installation and Service Manual

Installation and Operation Manual

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Replacement Parts List

MACHINES / RECLAIMS WITH DUST BAG

Torit Easy-Trunk. Installation and Operation Manual Installation, Operation, and Service Information. English Master Language

Downflo Oval DFO 2-8, 2-12, 2-16, 2-24, , 3-12, 3-18, 3-24, 3-36, 3-48, 3-60, 3-72, 4-16, 4-32, 4-48, 4-64, 4-80, 4-96, 4-112, and 4-128

Portable Systems & Parts Book

Installation and Operation Manual

75L & 100L JACKETED ASSEMBLY INSTRUCTIONS FOR PROCESS REACTOR SYSTEMS N. Mill Road Vineland, NJ Phone: Fax:

Powers TM Controls SW 141 Differential Static Airflow Switches

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Positive Displacement Pump

Unimaster Dust Collector UMA 40, 70, 100, 150 and 250 Built After August 2005 UMA 450 and 750 Built After March 2006

Torit PowerCore TG 2, 4, 6, 8, and 12

Downflo Evolution DFE 2-4 and 3-6

Martin Air Cleaner. Operator s Manual M3918

IOM AK (ENG) Revision 3

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast.

CDC-1 Reverse Pulse Dust Collectors Models 300, 600, and 900 CFM O. M

DUST COLLECTORS DOWNFLO OVAL

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Transcription:

RP1 TWISTER Micro Air Installation and Operation Manual IMPORTANT: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible to list all the hazards of dust control equipment. All persons involved with the equipment or systems should be instructed how to operate in a safe manner.

CAUTIONS: Avoid mixing combustible materials, such as buffing lint, paper, and wood with dust generated from grinding ferrous metals due to the potential fire hazard caused by sparks in the unit. Under no conditions should cigarettes or any other burning object be put into the unit. All users of MicroAir dust collection equipment should comply with all National and Local Fire Codes and/or other appropriate codes when determining the location and operation of dust control equipment. This unit is not suited for applications where explosion potential is present. Consult the Factory to determine if there is a risk. INSTALLATION: INSPECTION: The MicroAir Twister (RP1) is shipped on one skid. This skid should be inspected for any visible damage that may have occurred during shipment. Note any damage on the packing slip. EQUIPMENT/TOOLS REQUIRED: Standard wrenches. Screwdriver Forklift Pipe Wrench ASSEMBLY OF UNIT: Determine the location where the unit is to be installed. Be sure to allow sufficient room around the unit to service the filters, and allow for exhaust air. 1. Uncrate the unit. Use caution not to damage the paint while dismantling the crate. SPECIFICATIONS: INPUT VOLTAGE: 120V 60Hz 1 Phase MOTOR/CURRENT: 1.5HP 1PHASE 3450RPM TEFC 120V: 18Amps OVERALL DIMENSIONS: Base Unit: 76 H x 25 W x 20 D FILTER AREA: 80/20 Media: 174 Sq. Feet Poly Media: 150 Sq. Feet AIR REQUIREMENTS: 1.1 SCFM at 80psi per second of cleaning pulse. Minimum air line is 3/4 Air Pressure regulated 80 90 psi. Clean, dry, compressed air at the correct pressure is required for the cleaning system to operate correctly. It is recommended that a pressure regulator and coalescing filter be installed between the compressed air source and the inlet to the table. 2. Remove any options ordered from the skid. 3. Assemble the optional wall bracket onto the unit. 4. Carefully mount the unit into its location. COMPRESSED AIR INSTALLATION The compressed air inlet for the Roto-Pulse cleaning system is on the side of the unit. A 3/4 air line is required (at a minimum) with 80 90 psi clean dry air, for proper operation of the Roto-Pulse System. 1. Locate the compressed air connection. 2. Connect your standard air fitting to the provided 3/4 NPT thread. 3. Connect your air line to the fitting. 1

ELECTRICAL INSTALLATION: ALL ELECTRICAL WORK MUST BE DONE BY A QUALIFIED ELECTRICIAN ACCORDING TO LOCAL CODES INSTALLATION CAN CAUSE EXPOSURE TO LIVE COMPONENTS. DISCONNECT ELEC- TRICAL POWER BEFORE PROCEEDING WITH INSTALLAITON. PROPER LOCK OUT/ TAG OUT PROCEDURES SHOULD BE USED. If the unit is ordered with 120V electrical wiring there is no additional wiring required. Simply plug the unit into any 110/120V electrical plug rated for 15A. UNIT OPERATION: 1. To start the unit, turn the switch located on the front of the unit to the on position. To stop the unit, turn the switch to the off position. CARTRIDGE CLEANING OPERATION: The Micro-Air Twister is designed with the Roto- Pulse Cleaning System to clean the cartridge filters. This system provides superior cleaning performance using a rotating tube with pre-drilled holes. As the diaphragm valve opens, the Roto-Pulse tube rotates while air exits the holes, thus providing the cleaning of the cartridge. For proper cleaning, the compressed air pressure should be regulated at 80-90 psi maximum. During normal operation the Roto-Pulse cleaning system is activated by depressing the pulse button located on the electrical box. The Roto-Pulse cleaning operation dislodges particles from the cartridges. Particles then fall down into the collector. NOTE: When servicing the collection system, be sure to turn the unit off. PULSE TIMING: The Twister is provided with a manual pulse option as the standard for all units. The filters can be pulse cleaned by depressing the pulse button (located on the front of the electrical box) and holding it down for approximately 2 seconds. Since the unit does not have Auto-Pulse the filters should be pulse cleaned regularly throughout the day. In addition they should be pulsed several times after the blower has been shut off. NOTE: Cleaning of the filters too often will decrease your level of performance. A certain level of dust cake on the filters will improve the efficiency of the filter cartridges. You should try to maintain a minimum of 1 in w.c. of pressure differential across the filters. If you can not maintain this minimum level of differential across the filters the time between cleaning pulses should be increased until this can be achieved. MAGNAHELIC INSTALLATION: 1. Turn off dust collector and disconnect power to the unit. 2. Mount the Magnehelic Gauge into the Magnehelic Mounting Bracket and place the (2) male barb fittings in the pressure ports locatedon the side of the Magnehelic Gauge. 3. Also use the two pressure port plugs supplied with the Magnehelic Gauge on the two ports located on the backside of the gauge. 4. Mount the bracket. Do not mount the bracket on the unit. Mounting screws may damage internal components. 5. Using 1/4 clear tubing (Additional length can be purchased) connect the LOW pressure port on the gauge to the clean air plenum and HIGH pressure port to the dirty air plenum. 6. Reconnect the power to the unit and start the dust collector. 2

BARREL LID INSTALLATION: 1. Remove parts from box and inspect for any possible damage incurred during shipping. 2. Using the 10 hose clamp attach the 8 flex hose to the collar on the slide gate. 3. With the remaining 10 hose clamp attach the barrel lid flex hose to the collar on the top of the 8 to 10 reducer. 4. Attach the 10 side of the reducer to the barrel lid. 5. With barrel lid installed a 55 gallon barrel (not provided) can be placed under the barrel lid for material collection. FILTER CHANGE: 1. Turn unit off. Manually pulse the unit several times to remove excess material from the filter. 2. Disconnect power to the unit. 3. Open the slide gate to empty any remaining material from the hopper. 4. Remove the barrel, barrel lid kit, and hopper by loosening the lowest joint band. The drop out plate will come off with the hopper. 5. Remove the 4-Prong knob and seal washer from below the filter. Save the knob. 6. Slide the filter down out of the unit. 7. Reverse steps 4-6 to install new filter. See Parts List Diagram for additional assistance. 3

Parts List Diagram Item # Part # Description Item # Part # Description Item # Part # Description 1 36720-10 Roto-Pulse Assembly 20 P1050 Edge Protector 35 P2704 3/8 Washer 2 38151-01 Body Weldment 21 P119 5/16-20 Bolt 36 P2766 Pulse Push Button 3 38154-01 Clean Air Plenum 22 P124 3/8-16 Bolt 37 P3403 5/8 ID Hose 4 38155-01 Roto-Pulse Seal Plate 23 P1363 Cord w/plug 38 P3411 1 Hose Clamp 5 38155-02 Blower Seal Plate 24 P141 3/8 Nut 39 P3158 8 Slide Gate 6 38155-03 Motor/Fan Plate 25 P142 3/8 Lock Washer 40 P345 14 Ga Cord 7 38155-04 Drop-Out Plate 26 P164 1/4-20 Bolt 41 P3508 5/16 Rivnut 8 38155-05 Exhaust Grill 27 P1954 Cord Strain Relief 42 P3559 Rubber Washer 9 38158-01 Hopper 28 P2059 #8 Screw 43 P3585 Hose Barb 10 38160-01 Silencer Assembly 29 P2075 Diaphram Valve 44 P3649 Knob 11 38162-01 Joint Band 30 P2301 1 1/2HP Motor 45 P3734 1/4 OD Air Hose 12 38165-01 Electrical Box Weldment 31 P2302 Blower Assembly 46 P3735 90 Presto Lock 13 38168-01 Electrical Box Cover 32 P233 5/16 Washer 47 P3924 Straight Presto Lock 33 P242 1/4 Lock Washer 48 P7401RM 80/20 Cartridge Filter 34 P249 5/16 Lock Washer 48 P7410RM Poly Cartridge Filter 4

Notes: Installation Date: Location: Machine Number: Installer: Air Pressure: Air Line Size: FilterType: 80/20 Cellulose Media (Red) OR Polyester Media (White) Distributor Company: Contact Name: Phone Number: ( ) - Other Notes: 5 Micro Air Inc Form. No. L2466 05/17