FPR Series Pump INSTRUCTION AND MAINTENANCE MANUAL: FPR SERIES PUMP. Sanitary Centrifugal Pump

Similar documents
FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment

Instruction and Maintenance Manual: FPR Series Pu m p

Instruction and Maintenance Manual: Sanitary Centrifugal Pump

INSTRUCTION AND MAINTENANCE MANUAL: FZX 2000 SERIES PUMP

Tri-Clover Manual and Air Actuated Fractional Valves

INSTRUCTION AND MAINTENANCE MANUAL:

Artesian Owners Manual

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Artesian2 Owners Manual

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

INSTRUCTION AND MAINTENANCE MANUAL: FKL-25, 50, 75, 150, 250 and 400 Style Pump

ArtesianPro Owners Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Artesian2 Owners Manual

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Cascade Owners Manual

Cascade Owners Manual

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

End Suction Centrifugal

INSTRUCTION AND MAINTENANCE MANUAL: FL2/FL3 Series Pumps (Models: 15, 58, 75, 100 & 130)

ArtesianPro Owners Manual

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

TBM Series 3-Way Ball Valve

Models P420A-3100 & P420A-5100

Illumifalls Patio Pond

INSTRUCTION AND MAINTENANCE MANUAL:

Artesian2 Owners Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

Model GP5128. Triplex Ceramic Plunger Pump Operating Instructions / Manual

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

User s Manual D-Series Blowers and Exhausters

Model GP5128HS. Hydraulic Drive Pump. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Read this entire manual before operation begins.

DAP-625S and DAP-875S

TECHNICAL SERVICE MANUAL

Submersible Pond Pump with UV 800 Gallons Per Hour

60 Series End-Mount Brake Instructions Standard Housing

Models GP7545GB-180/ GP7555GB-180. Gearbox Versions for Pinion Shaft Drives

MetroPrime 22MPC Self-Priming Centrifugal Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Premium Pond Pump 330 Gallons Per Hour

INSTALLATION AND SERVICE MANUAL

Instruction and Maintenance Manual: FL II Series Pumps (Models: 15, 58, 75, 100 & 130)

Model GP5128. Triplex Ceramic Plunger Pump Operating Instructions / Manual

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Submersible Waterfall Pump 1200 Gallons Per Hour

Mega-Flow External Damper Fans

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

D-Series Blowers and Exhausters

Guardian Taper Grid Shaft Coupling

Model. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual SP100W/SP351W

Read this entire manual before operation begins.

Installation and Maintenance Manual

Model GP7122. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Positive Displacement Pump

Premium Waterfall Pump 1200 Gallons Per Hour

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

MP Series. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. Pump Models: MP4120 MP4124 MP4126 MP4130 MP4130HK MP4135

Service Guide JATCO Environmental Protection Tank Model J-7000

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

TITAN FLOW CONTROL, INC.

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Guardian Steel Gear Shaft Coupling

Read this entire manual before operation begins.

Installation & Operating Manual

Dodge 24v ISBe

Natural Fiber Planter Fountain

Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

Installation Manual DIAPHRAGM WELL TANK

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

NECO Pumping Systems

AT Clutch Major Service Sizes 25, 55, 115

WELDING FUME EXHAUSTERS & ARMS

Series 867 Reduced Pressure Zone Assemblies

APCO CSV-1600 SURGE CHECK VALVE

AIR CHAMP PRODUCTS. User Manual. DAP-625S and DAP-875S FORM NO. L D-0914

CRD610 Automatic Fitting Inserter

Model C230 Pump Controller

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

Installation Instructions

COYOTE ENTERPRISES, INC. 9/10 BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Atlas PV-9WP Addendum

Transcription:

FPR Series Pump INSTRUCTION AND MAINTENANCE MANUAL: FPR SERIES PUMP Sanitary Centrifugal Pump

Fristam Pumps 2 DESCRIPTION This manual contains installation, operation, assembly, disassembly and repair instructions for the Fristam FPR centrifugal pump. The motors are standard NEMA totally enclosed fan cooled (TEFC) motors. They are C-face and have a locked front bearing. These motors do require feet. Replacements motors are easily available from local motor distributors. CAUTION: BEGIN ALL PUMP MAINTENANCE OPERATIONS BY DISCONNECTING THE ENERGY SOURCE TO THE PUMP. OBSERVE ALL LOCK OUT/TAG OUT PROCEDURES AS OUTLINES BY ANSI Z244.1-1982 AND OSHA 1910.147 TO PREVENT ACCIDENTAL START- UP AND INJURY.

FPR Series Pump 3 TABLE OF CONTENTS Technical Information...4 Preventative Maintenance...5-6 Single Seal Assembly drawing...6 Double Seal Assembly drawing...7 Exploded Assembly FPR 700-3540...8-9 Exploded Assembly FPR 345, 355, 1050 & 1160...10-11 Seal Replacement Disassembly...12 Assembly...13-17 Pump Shaft Replacement Disassembly...18 Assembly...19 Setting Impeller to Housing Gap...20 Motor Replacement...22 Installation...23-25 Troubleshooting...26-28 Warranty...31

TECHNICAL INFORMATION Fristam Pumps SPECIFICATIONS Maximum Inlet Pressure...150 PSI Temperature Range...-40 o F 400 o F Noise Level... 60 85 db (A) STANDARD MATERIALS OF CONSTRUCTION (NOTE: OTHER OPTIONS AVAILABLE) Product Contact Components...AISI 316L Stainless Steel Seal Components Single Rotating Seal...Chrome Oxide coated 316L Stainless Steel Stationary Seal...Carbon Double Rotating Seal (if installed)...ceramic Product Contact Surface Finish... 32 in Ra Flange Support...Cast Iron Gaskets / O-rings...Viton Cover O-ring... Buna Motor... NEMA TEFC C-face (Painted Rolled Steel or Painted Cast Iron...3 Phase, 60 Hz, 208-230/460 VAC, 1750/3500 RPM FRONT PULL-OUT SEAL OPTIONS Single Internal Mechanical Single Internal Mechanical with Cascade Single Internal Mechanical with Double External Mechanical Recommended Seal Flush Pressure... 5 PSI Maximum Recommended Seal Flush Flow... 1 2 Gallons per Hour SEAL SIZES 757 Used on Models: 700, 710, 720, 3520, 731, 3530, 740, 1740 & 3540 Motor Frame Range: 140TC 320TC Single Flange 758 Used on Models: 3450, 3550, 1051 & 1161 Motor Frame Range: 180TC 360TC Double Flange RECOMMENDED TORQUE VALUES Impeller Nut: Models 700-355... 40 ft-lbs Impeller Nut: Models 1050-4000... 90 ft-lbs 757 Housing Clamp Bolt... 55 ft-lbs 758 Housing Bolts... 50 ft-lbs Motor Bolts 56C 140TC... 20 ft-lbs 180TC 280TC... 55 ft-lbs 320TC 360TC... 110 ft-lbs Shaft Collar Screw(s) 56C 140TC... 6 ft-lbs 180TC 280TSC... 15 ft-lbs 280TC 360TC... 40 ft-lbs 4

FPR Series Pump IMPELLER GAPS (TO HOUSING/TO COVER) 700, 710, 720, 731, 740, 1740... 0.5 mm (0.020 ) / 0.5 mm (0.020 ) 3530, 3450, 3550, 3540, 3520, 1051... 1 mm (0.040 )/ 0.5 mm (0.020 ) 1161... 1.5 mm (0.060 )/ 2 mm (0.080 ) 4000..2.0 mm (0.80 )/2 mm (0.80 ) TOOLS FOR ASSEMBLY & DISASSEMBLY 9/16 socket...56c 140TC motor bolts 3/4 socket... 180TC 280TC motor bolts, double flange housing bolts...single flange housing clamp bolt 15/16 socket...impeller nut, 320TC 360TC motor bolts 3/16 Allen wrench socket...56c 180TC shaft collars 1/4 Allen wrench socket...210tc 250TC shaft collars 5/16 Allen wrench socket...280tc 360TSC shaft collars 3/4 wrench... Single flange clamp bolt Ratchet... For loosening bolts Torque wrench...for proper tightening Adjustable pliers...for removing water pipes Soft-faced hammer...for removing cover star nuts 3/8 diameter rod... For holding the shaft when tightening & loosening the impeller Food grade lubricant..for lubricating o-rings and gaskets RECOMMENDED PREVENTIVE MAINTENANCE RECOMMENDED SEAL MAINTENANCE Visually inspect mechancical seal daily for leakage. Replace mechanical seal annually under normal duty. Replace mechanical seal as often as required under heavy duty. ELASTOMER INSPECTION Inspect all elastomers when performing pump maintenance. We recommend replacing elastomers (o-rings and gaskets) during seal, pump shaft and/or motor replacement. MOTOR LUBRICATION RECOMMENDATIONS Use a high grade ball and roller bearing grease. Recommendations for standard service conditions include Shell Dolium R or Chevron SRI. (See Tables 1-3 for more details.) NEMA/(IEC) Frame Size Rated Speed - RPM 3500 1750 Table 1: Motor Lubrication Intervals for Standard Conditions Up to 210 incl. (132 IEC) 5,500 hrs. 12,000 hrs. Over 210 to 280 incl. (180 IEC) 3,600 hrs. 9,500 hrs. Over 280 to 360 incl. (225 IEC) 2,200 hrs. 7,400 hrs. For severe service conditions, multiply interval hours by.5 For extreme service conditions, multiply interval hours by.1

Fristam Pumps 6 Table 2: Service Conditions Definitions Service Conditions Maximum Abient Temperature Atmospheric Contamination Standard 104 F (40 C) Clean, little corrosion Severe 122 F (50 C) Moderate dirt, corrosion Extreme >122 F (>50 C) Severe, dirt abrasive dust, corrosion Table 3: Volume of Grease to be Added per Bearing Frame Size NEMA/(IEC) Grease IN. 3 Volume TSP Up to 210 incl. (132 IEC) 0.6 2.0 Over 210 to 280 incl. (180 IEC) 1.2 3.9 Over 280 to 360 incl. (225 IEC) 1.5 5.2 Single Rotating Seal SINGLE SEAL ASSEMBLY Single Seal Spring Seal Driver Stationary Seal Impeller Nut Gasket Single Stationary Seal O-Ring Single Rotating Seal O-Ring Inner Seal Driver O-Ring Outer Seal Driver O-Ring

FPR Series Pump 7 DOUBLE SEAL ASSEMBLY Single Rotating Seal Single Seal Spring Seal Driver Stationary Seal Double Rotating Seal Double Seal Spring Double Rotating Seal O-Ring Double Stationary Seal O-Ring Inner Seal Driver O-Ring Single Rotating Single Seal O-Ring Stationary Seal O-Ring Outer Seal Driver O-Ring Impeller Nut Gasket

Guard Screw Fristam Pumps 8 Guard Flange Clamping Nut Motor Shaft Clamp Impeller Key Clamping Bolt Motor Bolt & Washer Shaft Exploded Assembly FPR 700-3540 Water Pipe Housing

FPR Series Pump 9 Single Stationary Seal O-Ring Single Rotating Seal O-Ring Inner Seal Driver O-Ring Double Seal Spring Double Rotating Seal O-Ring Double Rotating Seal Double Stationary Seal O-Ring Stationary Seal Single Rotating Seal Single Seal Spring Seal Impeller Driver Impeller Nut Cover Outer Seal Driver O-Ring Impeller Nut Gasket Cover O-Ring Cover Star Nut

Motor Fristam Pumps 10 Motor Bolt & Washer Flange Guard Screw Shaft Clamp Impeller Key Guard Shaft Housing Bolt & Washer Water Pipe Housing Exploded Assembly FPR 345, 355, 1050 & 1160

FPR Series Pump 11 Double Rotating Seal O-Ring Double Stationary Seal O-Ring Single Stationary Seal O-Ring Double Seal Spring Double Rotating Seal Stationary Seal Single Rotating Seal Single Seal Spring Seal Driver Impeller Impeller Nut Cover Single Rotating Seal O-Ring Inner Seal Driver O-Ring Outer Seal Driver O-Ring Impeller Nut Gasket Cover O-Ring Cover Star Nut

Fristam Pumps 12 SEAL REPLACEMENT DISASSEMBLY FIGURE 1 Remove flange guard. Remove cover star nuts with soft-faced hammer. Remove cover and discard cover o-ring. FIGURE 2 3/8 Shaft Hole Place 3/8 rod or Phillips screwdriver in shaft hole. Use 15/16 socket with ratchet to remove impeller nut. Discard impeller nut gasket. Remove impeller and discard impeller o-ring. Remove key.

FPR Series Pump 13 FIGURE 3 Double Seal Components Remove seal driver/rotating seal assembly. Discard rotating seal, o-rings and spring. Remove stationary seal and discard. Double Seal Only: Remove double rotating seal and double spring and discard. ASSEMBLY DOUBLE SEAL ONLY: FIGURE 4 Install spring behind shaft pins. Place o-ring into double rotating seal and lubricate. Push seal onto shaft making sure slots align with pins. (Note: housing and flange removed from picture for clarity)

Single Stationary Seal O-ring Fristam Pumps 14 FIGURE 5 Single Seal: Install single stationary seal o-ring and lubricate. Double Stationary Seal O-ring Double Seal: Install single and double stationary seal o-rings and lubricate. Align flats on housing & seal FIGURE 6 Install the stationary seal into housing making sure to align flats on the seal with the flats on the housing. FIGURE 7 Install spring behind seal pins inside the seal driver.

FPR Series Pump 15 FIGURE 8 Install single rotating seal o-ring and lubricate. Slide seal driver onto rotating seal making sure to align pins inside the driver with the slots on the seal. FIGURE 9 Slide small rotating seal o-ring onto the shaft and lubricate. (Note: housing and flange removed from picture for clarity) FIGURE 10 Slide seal driver assembly onto the shaft. (Note: housing and flange removed from picture for clarity)

Fristam Pumps 16 FIGURE 11 Install impeller key and outer seal driver o-ring. Lubricate o-ring. Seal Driver O-ring FIGURE 12 Slide impeller onto shaft making sure to align keyway in impeller with key in the shaft. Lubricate impeller nut gasket and place it onto the impeller nut. Thread impeller nut onto shaft. Place 3/8 rod or Phillips screwdriver in shaft hole. Use 15/16 socket with torque wrench and torque nut to 40 ft-lbs.

FPR Series Pump 17 FIGURE 13 Install cover o-ring. FIGURE 14 Install cover. Install cover star nuts and tighten with a soft-faced hammer.

Fristam Pumps 18 DISASSEMBLY Disassemble pump as described in Figures 1-3 PUMP SHAFT REPLACEMENT FIGURE 15 (700-354 MODEL PUMPS ONLY) Double Seal and Water Cascade Only: Remove water pipe(s) using adjustable pliers. Use two 3/4 wrenches to loosen the clamping bolt and nut. Remove the housing. FIGURE 16 (345, 355, 1051 & 1161 MODEL PUMPS ONLY) Double Seal and Water Cascade Only: Remove water pipe(s) using adjustable pliers. Use a 3/4 socket to remove the housing bolts and washers. Remove the housing.

FPR Series Pump 19 FIGURE 17 Shaft Clamp Cap Screw Use an Allen wrench to loosen the shaft clamp cap screw(s). Remove pump shaft. ASSEMBLY FIGURE 18 Align slits Install new shaft making sure to align the slit in the shaft with the slit in the shaft clamp. Also align the keyway in the motor shaft with the hole in the pump shaft. (Note: flange removed for clarity) Align hole with keyway FIGURE 19 (700-354 MODEL PUMPS ONLY) Install housing hub into the flange. Rotate the inlet to align it with the piping. Use a 3/4 wrench and a 3/4 torque wrench to torque the clamping bolt to 55 ft-lbs.

Fristam Pumps 20 FIGURE 20 (345, 355, 1051 & 1161 MODEL PUMPS ONLY) Install housing hub into the flange. Rotate the inlet to align it with the piping and align bolt holes. Install the lockwashers and bolts. Use a 3/4 torque wrench to torque the bolts to 50 ft-lbs. SETTING IMPELLER-TO-HOUSING GAP FIGURE 21 Feeler Gauge Assemble seal as described in figures 4-11. Slide impeller onto shaft making sure to align keyway in impeller with key in the shaft. Lubricate impeller nut gasket and place it onto the impeller nut. Thread impeller nut with gasket onto pump shaft. Use a torque wrench to torque the impeller nut to 40 ft-lbs. Slide a feeler gauge between the impeller and housing. The thickness of feeler gauge is determined by the pump model. (Note: see page 3 for gauge thicknesses) Push Set the impeller-to-housing gap (see figure 22) by pushing on the impeller. Once the feeler gauge fits snugly behind the impeller, tighten the shaft clamp bolt with an Allen wrench to the correct torque. (Note: see page 3 for torque values) Remove feeler gauge.

FPR Series Pump 21 FIGURE 22 The impeller-to-housing gap is measured between the back of the impeller and the housing. Impeller-to-Housing Gap Install cover o-ring, cover and cover star nuts as described in figures 13-14.

Fristam Pumps 22 MOTOR REPLACEMENT DISASSEMBLY Disassemble pump as described in figures 1-3. Remove housing and shaft as described in figures 15-17. FIGURE 22 Use a socket to remove the motor bolts and washers. Remove the flange. ASSEMBLY Replace motor. Install flange onto motor. Replace bolts and washers. Use a torque wrench to tighten the bolts to the correct torque. (Note: see page 3 for torque values) Install shaft and housing as described in figures 18-20. Assemble seal as described in figures 4-11. Set impeller-to-housing gap as described in figure 21. Install cover o-ring, cover and cover star nuts as described in figures 13-14. Replace guard(s) and water pipe(s) if necessary.

FPR Series Pump 23 INSTALLATION UNPACKING Check the contents and all wrapping when unpacking the pump. Inspect the pump carefully for any damage that may have occurred during shipping. Immediately report any damage to the carrier. Remove the shaft guard and rotate the pump shaft by hand to make sure the impeller rotates freely. Keep the protective caps over the pump inlet and outlet in place until you are ready to install the pump. INSTALLING Prior to actually installing the pump, ensure that: The pump will be readily accessible for maintenance, inspection and cleaning. Adequate ventilation is provided for motor cooling. The drive and motor type is suitable for the environment where it is to be operated. Pumps intended for use in hazardous environments (i.e. explosive, corrosive, etc.) must use a motor and drive with the appropriate enclosure characteristics. Failure to use an appropriate motor type may result in serious damage and/or injury. PIPING GUIDELINES This section describes good piping practices to obtain maximum efficiency and service life from your pump. Figure 23 Maximum performance and trouble-free operation require adherence to good piping practices. Ensuring proper piping support and alignment at both the suction inlet and discharge outlet can help prevent serious damage to the pump housing (Figure 23). Avoid abrupt transitions in the piping system (Figure 24). Avoid throttling valves in the suction piping. Keep suction lines as short and direct as possible. Ensure that the NPSH available in the system is greater than NPSH required by the pump. Figure 24 Avoid sump areas where sediments may collect (Figure 25). Figure 25

Fristam Pumps 24 Avoid the formation of air pockets in the piping (Figure 26). Figure 26 Avoid abrupt closure of shut-off valves, this may cause hydraulic shock which can cause severe damage to the pump and system. Avoid elbows in the suction line if possible. When necessary they should be located 5 pipe diameters away from the pump inlet, and have a bend radius greater than 2 pipe diameters (Figure 27). Figure 27 Check valves in discharge line should be a minimum of 5 ft. away from the pump outlet (Figure 27). ELECTRICAL INSTALLATION We use standard duty TEFC motors unless otherwise specified. Many motor options are available: washdown, flameproof, explosion proof, hostile duty or chemical duty. The motor selected should meet the requirements of the specified operating conditions. A change in conditions (for example, higher viscosity, higher specific gravity, lower head losses) can overload the motor. When changing operating conditions or whenever there is any doubt, please contact Fristam Pumps, Inc., for technical assistance. Have an electrician connect the motor using sound electrical practices. Provide adequate protection. Pumps fitted with mechanical seals must not run dry, not even momentarily. Determine the direction of rotation by watching the motor fan, which must turn clockwise. PUMP OPERATIONS START-UP INSTRUCTIONS Remove any foreign matter that may have entered the pump. Do not use the pump to flush the system! Check pump for proper rotation as indicated on the pump. Proper motor direction is clockwise when looking at the fan end of the motor. (NOTE: When checking the direction of rotation, the pump must be full of liquid.) Never run the pump dry, even momentarily. Seal damage can result. SHUT-DOWN INSTRUCTIONS Shut off the power supply to the pump. Close the shut-off valves in the suction and discharge piping. Drain and clean the pump. Protect the pump against dust, heat, moisture and impact damage.

FPR Series Pump 25 INSTALLATION OF WATER FLUSH FOR DOUBLE MECHANICAL SEAL Set up the water flush for the double mechanical seal as shown (Figure 28). Use only between 1-2 gallons per hour of water at a maximum pressure of 5 PSI. Excessive flow of water through the seal increases the pressure inside the seal. Note: maximum pressure inside the seal is 5 PSI. Excessive flow/pressure through the seal flush will cause excessive wear and shorten seal life. Pipe the exit side of the water flush with 2-5 feet physical height of tubing. This ensures that some water is always in the center seal and the seal never runs dry. It is possible to inject steam through the center seal (within the pressure requirements). We do not recommend using steam alone for the cooling/lubricating of the seal. It is desirable to have the flush water on the outlet side visible. This allows an easy check to see that the flush water is on and also if the seal is functioning properly. In a malfunctioning seal the flush water will disappear, become discolored, or show an unusual increase in flow. If these conditions exist, check the seal and replace if necessary. VISIBLE WATER FLOW TO DRAIN 2-5 FEET Figure 28 THROTTLE THIS VALVE TO 1-2 GAL/HR 1/8" N.P.T. COOLING WATER IN WATER PIPE CONNECTIONS FOR DOUBLE SEALS IL-0173 7/7/00 INSTALLATION OF WATER CASCADE The water cascade (if supplied) is piped through the hub of the pump housing and into the stationary seal. Since there is no rear seal, the flush water will exit through the rear of the seal area (Figure 29). Not all FPR pumps require a water cascade on the seal. Use about 1-2 gallons per hour of water at a maximum pressure inside the seal of 5 psi. Figure 29 WATER IN 1265000062 8/21/02

Fristam Pumps 26 PUMP MAINTENANCE RECORD DATE SERVICE PERFORMED BY

Fristam Pumps 28 NOTICE OF TERMS, WARRANTY PROVISIONS INCLUDING DISCLAIMERS, CLAIMS AND LIMITATION OF LIABILITY Prices and all terms and conditions of sale are established in current price sheets and are subject to change without notice. All orders are subject to acceptance by Fristam Pumps USA, Limited Partnership. Each Fristam Pumps item is warranted to be free from manufacturing defects for a period of one (1) year from the date of shipment, providing it has been used as recommended and in accordance with recognized piping practice, and providing it has not been worn out due to severe service, such as encountered under extremely corrosive or abrasive conditions. This warranty is expressly in lieu of any other warranties expressed or implied, including but not limited to, any implied warranty of merchantability or fitness for particular purpose. All other warranties whatsoever, expressed or implied by law or otherwise, are hereby excluded. All claims must be in writing and must be mailed or delivered by purchaser within thirty (30) days after purchaser learns of the facts upon which such claim is based. Any claim not made in writing and within the time period specified above shall be deemed waived. Purchaser s sole and exclusive remedy and Fristam Pumps maximum liability for claims arising hereunder or for negligence for any and all losses and damages resulting from any cause shall be either the repair or replacement of defective items or, at Fristam Pumps option, the refund of the purchase price for such items. In no event, including in the case of a claim for negligence, shall Fristam Pumps be liable for incidental or consequential damages, including loss of profits. No person, including any representative employee or agent of Fristam Pumps is authorized to assume on behalf of Fristam Pumps any liability or responsibility in addition to or different from that described in this provision. Any and all representations, promises, warranties or statements that are in addition to or different from the terms of this provision are of no force or effect. If any provision of this Notice is held to be invalid, such provision shall be severed and the remaining provisions shall continue to be in force.

FPR Series Pump 29 Copyright 2008 - Fristam Pumps USA Limited Partnership Drawing # 1250000002 Updated 12/28/07 Part # 1050000040 Visit www.fristam.com for a current list of literature. 2410 Parview Road Middleton, WI 53562-2524 1-800-841-5001 608-831-5001 Website: www.fristam.com Email: fristam@fristampumps.com