INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Similar documents
power cable accessories

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

Cellplux Plug-in Technology

INSTALLATION PRODUCTION TESTS

Transformer bushings, type GOH. Technical guide

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Completing the picture

NXPLUS C Single busbar. Maintenance-free for lifetime

Zinc-Oxide Surge Arrester TEXLIM Q-C

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

THORNE & DERRICK UK TEL FAX TEL FAX

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

High Voltage Accessories up to 72.5 kv

a Nexans company Catalogue 2007

Nexans Network Solutions Div. Euromold

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Gas Insulated Metal-clad Switchgear, HMGS!

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

a Nexans company Catalogue 2009

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

High Voltage and Extra High Voltage Cables

Zinc Oxide Surge Arrester EXLIM R

Zinc Oxide Surge Arrester PEXLIM Q

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

Unified requirements for systems with voltages above 1 kv up to 15 kv

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

ZX-Family Gas-insulated medium voltage switchgear

Surge arrester POLIM-H..SD

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

IEC Separable Connectors 17.5 kv/24 kv, 630A

8DJ. Maintenance-free for lifetime

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

600 A 15 kv class T-OP II deadbreak connector

B kv T&D GAS INSULATED SWITCHGEAR

Separable Connectors and Kits

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

600 A 35 kv class BT-TAP deadbreak connector

GENERAL. CONSTRUCTION External

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Surge arrester POLIM-H.. ND

On-load tap-changer OILTAP V

a Nexans company Catalogue 2009

Current accuracy class. Sensor principles

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

a Nexans company Catalogue 2015

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Transformer bushings, type GSA-OA Technical guide

Benefits, typical uses

Surge arresters Product overview

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Nexans Network Solutions Div. Euromold

TGK Prefabricated Substation Technical Data

ZX2 Gas-insulated medium voltage switchgear

a Nexans company Catalogue 2009

Product Specification

3EP6 porcelain surge arrester

High Voltage Surge Arresters Station Class

Shielded surge arresters

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

B kv Gas-insulated Substations

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

MEDIUM VOLTAGE NETWORKS

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

ZX2.2 Gas-insulated medium voltage switchgear

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Surge arrester POLIM-C.. HD

3EQ Composite Housed Surge Arresters

a Nexans company Catalogue 2015

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance


3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Product Description: Objective and Certification: Test Samples and Test Cable:

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

H e a t s h r i n k P r o d u c t G u i d e

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Transcription:

INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side style arrangements which have been previously available. Dead front design means less maintenance. The high voltage compartment does not require constant cleaning and is not affected by harsh environments. Deadfront means no exposed live parts; this provides a higher degree of safety. Lower risk of arc flash phase to phase or phase to ground. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. The 44kV MiniSub TM system is rated 600A, 1500MVA, 250 kv BIL. Because it is a MiniSub TM, it can be available with all features on the low voltage side as our previous units Main breakers Custom and Utility Metering Secondary distribution SCADA And more. See our regular brochure for more info or visit: http://www.powersystems.ca/

CABLE TERMINATION SYSTEM The cable termination systems include separable connectors and bushings in sizes 0, 1, 2 and 3. The separable connector is plugged into the bushing and bolted mechanically. The system must be de-energized when inserting or removing the connectors. The absence of voltage may be tested on the capacitive voltage tap integrated into the separable connector. Special features of the cable termination system: - metal-enclosed - fully-insulated W touch proof - free from arcing - high short-circuit protection - maintenance-free - fully submersible - for outdoor use - dirt proof - IP 66 - up to 11 kv E Exe - The contact parts are designed for stranded circular aluminum or copper conductors to DIN VDE 0295. - Separable connectors for stranded sector-shaped, solid sector-shaped or solid circular conductors are available upon request. - The insulating and field-control- ling part is designed to fit all PVC- insulated cables. - Separable connectors can be installed on different types of plastic cables. To enable us to adjust the components to your specific requirements, kindly complete the Form to determine Separable Connectors D Bushing 10. female contact part 11. insulating bushing 12. housing A Contact System 1. contact ring 2. tension cone 3. thrust piece B Insulating and fieldcontrolling part C Housing 4. bell flange 5. pressure sleeve 6. pressure spring 7. heat-shrink tubing 8. test lead 9. cable screen

Separable Connectors Size 0-3 Technical data Test Specification to DIN VDE 0278 Part 6 High-Current-Proof Design II Cable Termination System DIN VDE 0278 Part 629-1 test series D, Tab. 7 20,8 / 36 / 42 kv type test, according on IEC 60 840 / 02.99 26 / 45 / 52 kv Size 3/S Nominal current IN (A) 1250 Max. operating voltage UM (kv) 52 Rated power frequency withstand voltage 50 Hz/1 min (kv) 95 Rated lightning impulse withstand voltage (BIL) 1,2/50 µs (kv) 250 Partial discharge 2 x U0 (pc) 10 D.C. voltage test 15 min 6 x U0 (kv) 156 Rated short-time withstand current 0,5 sec (ka) 63 1 sec (ka) 50 Rated impulse current (ka) 150 Weight ca. kg 9,4 approx.kg Size classification list of Cable Connectors Size max. conductor max. cross min. ø over max. diameter remarks diameter section insulation over insulation 3 32,6 mm 630 31,6 47,1 mm with voltage tap 3 32,6 mm 630 31,6 50,6 mm without voltage tap Specifications The Standards for surge arresters (DIN VDE 0675, Part 4/05.94 and IEC 99-4) are applicable to these devices. The dimensions of the plug- in termination system comply with EN 50180/EN 50181. Design The live part consists of metal oxide resistors without spark gap. The resistors possess a high thermal stability ensured by suitable dimensioning. These live parts are enclosed by a silicone rubber jacket that provides insulation against the metal housing. The corrosion-resistant aluminum housing renders the surge arrester intrinsically safe and thus assures optimal safety for operating personnel. The metal housing provides a hermetic sealing of the live parts against environmental influences, such as moisture or pollution. The plug-in connector is designed to fit the inside cone plug-in termination system acc. EN 50180/EN 50181.It is available in sizes 1, 2 and 3.The cable termination is attached via flange and is thus in conformity with the installation. The arrester is equipped with a corrosion-resistant fracture membrane that opens the arrester in case of an internal fault and allows for a defined axial pressure relief on the bottom of the arrester without any damage to the plug-in system.

Lightning Arrestors Scope of Application Surge arresters are used for the protection of metal-enclosed switchgear and transformers equipped with plug-in type bushings acc. EN 50180/EN 50181. The separable surge arrester is installed on the switchgear/transformer to prevent the intake of unduly high over-voltages. The surge arrester limits particularly those over-voltages that are produced by the reflection of traveling waves. When using these surge arresters for switchgear/transformers connected to the transmission line via a cable route, it is necessary to protect the transition between the cable and the transmission line with suitable arresters. The capacity of protection is specially coordinated with the switchgear s resistance to surge voltages, considering at the same time the space arrangement and the level of electrical protection. For distribution systems based on metal oxide resistors with plug-in type bushing size 1, 2 and 3 for rated voltages from 6 to 52 kv nominal discharge current 10 ka high-current impulse withstand 65 ka line discharge class 1 acc. DIN VDE 0675 part 4 and IEC 99-4,suitable for inside-cone termination system acc. EN 50180/ EN 50181 Selection of the Rated Voltage Selection Parameters The selection of the rated voltage depends on the maximum operating voltage of the system as well as on the type of neutral point. The selection is done in accordance with the following table, for example: Um = 24 kv maximum permissible operating voltage of the installation (GIS/transformer). Type of neutral point: insulated. According to the table below, the rated voltage of the arrester to be selected is Ur = 30 kv. Max. Operating Voltage Rated Voltage, Rated Voltage, Insulated or Compensated Solidly Earthed System (earth fault factor up to 1.7) Um (kv) Ur (kv) Uc (kv) Ur (kv) Uc (kv) 7,2 9 7,2 7,2 6 12 15 12 12 9,5 14,5 9 15 15 12 17,5 22 17,5 18 14 24 30 24 24 19 36 45 36 36 29 42 52 42 42 33 With compensated or insulated systems, the continuous voltage Uc of the arrester must be equal to the maximum operating voltage Um. If the selected continuous voltage is too low, this can lead to a failure of the surge arrester.

Protection Values of Surge Arresters Rated voltage Continuous operating voltage Max. residual voltage 8/20: Technical Data Ur: 6 kv 52 kv Uc: 4,7 kv 42 kv Ures at 10 ka, 18 kv 153 kv Thermal energy discharge capacity 2 kj/kvrated Rated lightning discharge Current (peak value in ka, waveform) isn: 10 ka, 8/20 µs High surge current (peak value in ka, waveform) ish: 65 ka, 4/10 µs Long-wave surge current (peak value in A, rectangular wave) isl: 250 A; 2000 µs Short-circuit strength (r.m.s. value in ka) 16 ka; 0,2 s No Size Ur Uc Dimensions mm Weight kv kv A B C kg 827 510 150 1 15 12 435 320 76 3,5 827 510 240 1 24 19 565 450 76 5,0 827 510 300 1 30 24 565 450 76 5,0 827 520 060 2 6 4,7 435 320 76 3,5 827 520 072 2 7,2 6 435 320 76 3,5 827 520 150 2 15 12 435 320 76 3,5 827 520 240 2 24 19 565 450 76 5,0 827 520 300 2 30 24 565 450 76 5,0 827 524 360 2 36 29 760 645 120 11,2 827 524 450 2 45 36 760 645 120 11,2 827 534 360 3 36 29 830 680 110 12,5 827 534 450 3 45 36 830 680 110 12,5 827 534 520 3 52 42 830 680 110 12,5 Other variants are available on inquiry. Um = Max. operating voltage Ur = Rated voltage of surge arrester Uc = Max. continuous voltage of surge arrester Rated Voltage Max. Continuous Voltage Max. Residual Voltage : - 1 ka, 8/20-5 ka, 8/20-10 ka, 8/20 Ur (kv) Uc (kv) Ures (kv) Ures (kv) Ures (kv) 6 4,7 13,9 16 17,6 7,2 6 17,4 20 22,0 9 7,2 20 24 26,4 12 9,5 27,8 32 35,2 15 12 34,8 40 44 18 14 41,6 48 52,7 19 15 45,1 52 57,1 22 17,5 52,1 60 66 24 19 55,5 64 70,3 30 24 69,4 80 87,9 36 29 83,3 96 105,5 45 36 104,2 120 131,9 52 42 120,7 139 152,7 65 52 150,9 174 190,45

The DSA-i3 integrated voltage testing system fulfills present day requirements for maintenance-free, cost-effective and reliable voltage indicating system, and meets the requirements specified in DIN VDE 0682, part 415, respectively IEC 61243-5. It features a clear voltage display DSA-i3 (red LCD). It is also equipped with test sockets for phase comparison. A third socket permits the display itself to be easily checked for reliability. CABLE INTEGRATING VOLTAGE TESTING SYSTEM Special Features Technical Data No external power supply required Integrated voltage limiting device Easy installation No in-service test required Nominal frequency 50 Hz / 60 Hz Threshold voltage 4 5 V Degree of protection IP 66 Input impedance 2 MΩ Operating temperature 25 bis / to +55 C Dimensions: width/height/depth 96 x 48 x 30 mm Diagrammatic sketch of a capacitive voltage divider Balance plate bar capacitance (minimum): C2Lmin=C1 x 0,12 x UN 1 C2W 1592 pf 5V Balance plate bar capacitance (maximum): C2Lmax =C1 x 0,4 x UN 1 C2W 1592 pf 5V

SYSTEM MOUNTING PLATE

Cable size to determine connector Company: Name: Date: Tel: Fax: E-mail: Cable manufacturer Cable type: Cross section Maximum operating voltage: Um kv Nominal voltage Un kv Line to earth voltage Uo kv Cable design: Single core cable: Super flexible cable: Three core cable: Application: Above ground: Soilproof: Capacitive voltage tap: Yes No Size of bushing: Size 0 Size 1 Size 2 Size 3 Conductor shape: Stranded circular: RM Solid circular: Stranded sector: Solid sector: Super flexible stranded: Super flexible cable: 1. Diameter of conductor mm 2. Diameter of insulation PVC: XLPE: EPR: mm 3. Diameter over outer semiconductor layer 4. Semi conductor layer Graphite: Fully bonded: Easy strip: 5. Screen Al: Cu: Type: Wires: Tape: 6. Armouring Yes: Al: Wire: No: Cu: Pb: Steel Tape: Corrugated: Max. current over armouring: Max A 7. Overall diameter mm RE SM SE RF mm

SAFE RELIABLE -- SECURE Power Systems Technology Ltd Tel: (613) 228-7228 1-866-300-1527 Fax: (613) 224-6012 300-30 Colonnade Rd N., Ottawa ON, Canada K2E 7J6