Solution Power Medium Voltage Metal Clad Switchgear

Similar documents
Solution Power Medium Voltage Metal Clad Switchgear

Prime-MEC LS HRC Power Fuses

Miniature Circuit Breakers BK63HU / BK63H

SF6 Gas Insulated Ring Main Unit RMU. A Compact switchgear solution for secondary power distribution networks. Super Solution.

Super Solution Retrofit VCB Vacuum Circuit Breakers

Leader in Electrics & Automation SOLUTION Power Transmission & Distribution

Tri-MEC Load Break Switch

Pro-MEC Vacuum Circuit Breakers Vacuum Interrupter

Up to 24kV Modular type Air insulated switchgear

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS]

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

the safe, reliable, and efficient choice for MV switchgear

Metal Clad Air Insulated Switchgear

Vacuum Circuit Breaker

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Unitole UP kv Primary substations Motor control centres

High Torque Performance and Precise Control. 0.75~75kW 3Phase 200 ~ 230Volts 0.75~160kW 3Phase 380 ~ 480Volts

High Torque Performance and Precise Control. 0.75~22kW 3Phase 200~230Volts 0.75~160kW 3Phase 380~480Volts. Automation Equipment.

Metal Clad Switchgears

High Torque Performance and Precise Control. 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Unitole UP kv Primary substations Motor control centres

Manual Motor Starters

Metal Clad VCBs ~ Mk1

Air-insulated switchgear UniGear type ZS1

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

with Vacuum Circuit Breaker HAF

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Metal-Clad Switchgear

PowerCube type PB series A complete solution for OEMs

CPG.0 Single busbar gas-insulated cubicles

PIX-H Metal-clad switchgear up to 17.5kV

Tri-MEC LS Medium Voltage Vacuum Contactors

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

Gas Insulated Switchgear

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Ensuring excellent switching capability and high quality with various advantages

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

MESG 12 / 17.5 / 24 / 36 KV

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

33KV INDOOR SWITCHGEAR

Gas Insulated Metal-clad Switchgear, HMGS!

Medium Voltage Metal-Enclosed Switches

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

with Vacuum Circuit Breaker HAF

Low Voltage Main Distribution Board

We build a better future!

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

Medium Voltage. ANSI C37.20 and NEMA SG-5

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Innovac SVS/08 - SVS/ kv modular switchgear

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Medium Voltage Metal-Enclosed Switches

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

MEDIUM VOLTAGE SWITCHGEAR

40.5kV ET2 Removable AC Metal-enclosed Switchgear

GROUP D. Switch & Protective device.

Valid for you. medium voltage switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Vacuum Circuit Breaker VS1

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

RAPIER DSB Disconnectors

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

TECHNICAL SPECIFICATIONS

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Power IT Air Insulated Cubicle Uniswitch

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

ASN3 ASN2 ASN1. ASN Series Medium voltage, metal-clad, air-insulated switchgear for primary distribution

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

NXPLUS C Single busbar. Maintenance-free for lifetime

FIXED VCB AIR INSULATED SWITCHGEAR

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

INESING SWITCHGEAR BROCHURE

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Transcription:

www.lsis.biz Solution Power Medium Voltage Metal Clad Switchgear

Contents Features 12 Ratings 14 Structures and dimensions 16 Accessories and apparatuses 18 Arrangement (for general application) 22 2I

LSIS showing the new, innovative products every customer desires to present standards for the future electric power solution as leading industrial electrical / electronic sectors with developing high-tech. I3

Vacuum Circuit Breaker, VCB is installed in the medium voltage distribution lines to protect life and load equipment. In case of accidents such as over current, short circuit and ground fault current, VCB works by interrupting the circuit through the inner Vacuum Interrupter which is acted by signal from the outside separate relay. LSIS' Super Solution, Susol VCB responds. - customer needs for the breakers with high interrupting capacity and large current due to the integration and increase of the load capacity. - worldwide trend of diversification in the medium voltage distribution lines. - increase of the reliability for the temperature characteristics of circuit breakers. Premium-type products to improve convenience and reliability of medium voltage switchgear configuration. - full line-up modeling to the high interrupting capacity and large current. - main structure with high reliability application. - a variety of accessories and ability to maximize. Suitable for use as the main circuit breaker to protect key installations in the places such as device industry, power plants, high-rise buildings, large ships. 4I

Strengthening of the high interrupting capacity and large current models and full line-up new VCB models to high/middle/low. Voltage Interrupting current Rated current 7.2kV 8/12.5/20/25/31.5/40/50kA 400/630/1250//3150/4000A 12/17.5kV 20/25/31.5/40/50kA 630/1250//3150/4000A 24kV 12.5/25/31.5/40kA 630/1250//2500/3150A 36kV 25/31.5/40kA 1250//3150A 40.5kV 25/31.5kA 1250//3150A Main circuit structure with high reliability. Maximizing the durability and reliability of the main circuit contactors (Stego Tulip contactor). Strong structure for the temperature rise (Natural cooling system). Convenience of switchgear configuration and a variety of accessories. CB compartment structure: Metal isolation structures to prevent the accident spread and ensure safety. And the convenience of switchgear building is extended by its module style. A variety of accessories: UVT, Locking Magnet, Plug Interlock, Key lock, Temperature Sensor, MOC, TOC, Earthing S/W. Maximizing compatibility with existing products through the dualistic deployment of phases and compact models. Type testing is complete for all models according to latest standard, IEC62271-100 (2008) [M2, E2 (List1 or 3), C2]. I5

Susol VCB installed Solution Power Medium Voltage Metal Clad Switchgear by adopting high performance and reliable Susol VCB supports compact size to be widely used in a variety of electric power facilities for the stable power supply and maintenance. Susol VCB Family Susol VCB series are premium-type products featuring main structure with high reliability application and a variety of accessories and ability to maximize to be suitable for use as the main circuit breaker to protect key installations in the places such as device industry, power plants, high-rise buildings, large ships up & Compact Full line 6I Full line-up new VCB models to the high interrupting capacity and large current (~ 50kA, ~ 4000A) featuring maximization of compatibility with existing products through the dualistic deployment of phases and compact models

< < Medium Voltage Metal Clad Switchgear 7.2/12/17.5kV (VL-06/12/17) 7.2/12/17.5/24/36/40.5kV (VH-06/12/17/24/36/40) Rated short-time (to withstand current ): 3sec. 4sec* Rated operating sequence: O-0.3s-CO-15s-CO Type test level: M2, E2 (List3), C2 Electrical and mechanical life: 30,000 operations Compatibility with existing Pro-MEC breakers Various cradle: E, F, G and H type CB Compartment for MCSG available A variety of control power - DC 24~30V, DC 48~60V, DC 110V, DC 125V, DC 220V - AC 48V, AC 100~130V, AC 220~250V A variety of accessories - VCB part: Charge switch, UVT, Secondary trip coil, Latch checking switch, Position switch, Locking magnet, Plug interlock, Key lock, Button cover, Button padlock, Padlock (H type Door interlock), MOC - Cradle part: MOC (Mechanical Operated Cell switch), TOC (Truck Operated Cell switch), Temperature sensor, Earthing switch & accessaries, Door, Door interlock, Door emergency button - Others: Racking in/out handle, UVT Time delay controller, CTD (Condensor Trip Device), Temperature module TEST/SERVICE Automatic Position Indicator Standards and certification - IEC62271-100 (2008) [M2, C2, E2 (List3)] - KEMA, KERI type tested, V-check (KESCO) certification Note ) * Please contact us Ur Isc Ir (kv) (ka) (A) 7.2 20 630 1250 25 630 1250 12 20 630 1250 25 630 1250 17.5 20 630 1250 25 630 1250 Rated short-time (to withstand current ): 3sec. 4sec* Rated operating sequence: O-0.3s-CO-3min-CO Type test level: M2, E2 (List3), C2 Electrical and mechanical life: 20,000 operations Various cradle: K and H type CB Compartment for MCSG available A variety of control power - DC 48V, DC 110V, DC 125V, DC 220V - AC 48V, AC 110V, AC 220V A variety of accessories - VCB part: UVT, Secondary trip coil, Latch checking switch, Position switch, Locking magnet, Plug interlock, Key lock, Button cover, Button padlock, Padlock (H type Door interlock), MOC - Cradle part: MOC (Mechanical Operated Cell switch), TOC (Truck Operated Cell switch), Temperature sensor, Earthing switch & accessaries, Door, Door interlock, Door emergency button - Others: Racking in/out handle, Lifting hook, UVT Time delay controller, CTD (Condensor Trip Device), Temperature module Standards and certification - IEC62271-100 (2008) [M2, C2, E2 (List3)] - KEMA, KERI type tested, V-check (KESCO) certification Note ) * Please contact us Ur Isc Ir (kv) (ka) (A) 7.2 50 1250 12 17.5 2500 3150 4000 24 25 2500 31.5 1250 3150 40 1250 3150 36 25 1250 3150 31.5 1250 3150 40 1250 3150 40.5 25 1250 3150 31.5 1250 3150 VCB Cradle type E type F type H type I7

Main circuit structure with high reliability Susol VCB Breaker Insulation rod Lower terminal Shunt Vacuum interrupter Upper terminal Tulip contactor Contacts Bellows shield Bellows Movable electrode Fixed electrode Fixed seal cup Arc shield Ceramic Movable seal cup Vacuum Interrupter, VI The vacuum rate within the VI is very high (approximately 5x10-5 Torr) and the spacing between fixed contact and movable contact is about 6~20mm, depending on the voltage. The contacts are in a structure that arc can easily be extinguished and the surfaces of the contacts are made of special alloy (copperchromium) and the interior is completely sealed to prevent loss of vacuum. Therefore the wearing of the contacts can be minimized in the event of short-circuit and the arc energy by overvoltage or switching can be reduced effectively. 8I

< < Medium Voltage Metal Clad Switchgear Convenience and Variety Maximizing the durability and reliability of the main circuit contactors (Stego Tulip contactor) Strong structure for the temperature rise (Natural cooling system) I9

Stego Tulip Main circuit structure with high reliability Maximizing the durability and reliability of the main circuit contactors (Stego Tulip contactor) Strong structure for the temperature rise (Natural cooling system) Tulip finger Tulip spring Main circuit terminal of the breaker Plate understar : Securing freedom of Tulip Plate star: Supporting Tulip for position maintaing and torsional flow prevention Structure of Stego Tulip Terminal Maintaining the connection between breaker and cradle for the optimum current path through securing freedom of Tulip. Increasing the heat dissipation area of the contactors and minimizing aging. Major supply records - S Electro-Mechanics, Busan plant: 12kV 40kA 4000A VCB - P Combined cogeneration power plant: 7.2kV 50kA 4000A VCB - K Petrochemical, Ulsan plant: 7.2kV 40kA 4000A VCB - P Steel plant, Gwangyang: 7.2kV 50kA 4000A VCB - P Steel plant, Pohang: 7.2kV 50kA 4000A VCB - L Chem, Cheongju plant: 7.2kV 40kA 4000A VCB - S Electronics, Tangjeong plant: 7.2kV 40kA 4000A VCB 10I

< < Medium Voltage Metal Clad Switchgear 6/12/17.5/24/36/40kV... (VH-06/12/17/24/36/40) Drawout / natural cooling system Improved temperature characteristics and ensured high reliability VL type Tulip contactor VH type Tulip contactor 36kV Tulip contactor I11

Solution Power Series Features Reduced installation space Securing a free space for installation even in the places where safety is top priority such as Power Plant(Nuclear, Thermal, Hydro and Cogeneration), Industrial Plant(semiconductor, petrochemical, steel) and Infrastructure facilities (subways, railways, airports), etc. Up to 57% reduction in installation space compared to conventional switchgear 20% reduction in the width of switchgear with rating upto 1250A Integration : Incoming VCB and main PT are installed in a panel (from 2 panels before) Solution Power Conventional Switchgear Incoming VCB + PT Feeder VCB Installation space Incoming VCB Main PT Feeder VCB reduced Note) 1. For models up to 24kV 25kA 1,250A. 2. In order to apply above size CT, PT and VCB models stated in this catalog should be applied. Safety considerations This Solution Power switchgear provides the best protection rating out of Air Insulated Switchgear!! Designed to remove explosion or damage to peripheral devices as possible in the event of internal arc happening.to prove its reliability and safety LSIS use the internationally recognized testing agency, KERI / KEMA / CESI for certification as well as LSIS' test lab PT&T that is a KOLAS-qualified (Korea Laboratory Accreditation Scheme) accredited testing laboratory and provides worldwide testing service. Metal clad type: each compartment is divided by metal partitions for the highest degree of protection rating out of Air Insulated Switchgears. Short-circuit, short-time current and internal arc tests passed at KERI / KEMA / CESI by IEC 62271-200. Various options including - Mechanical interlock to prevent from inadvertent operating - Mechanism enable the breaker to be drawn in or out without opening the door - Position padlock to lock the breaker at the present position. Solid structure with hinge and locker IP Cover on the face of the breaker and inspection window on the door Metal shutter and shutter padlock installed in CB compartment for safe maintenance Used reliable tube & boots for busbar insulation Insulation cap and padlock used for earthing switch to secure insulation and safety CT equipped with protective insulation wall Inhouse test equipment with 1,500 MVA capacity for performing reliability test 12I

Convenient maintenance and inspection Preventive maintenance is essential for all switchgears. LSIS' One-Stop Total preventive maintenance activities cover continuous maintenance, inspection, remaining life expectancy and streamline. Solution Power Switchgear is structured for these convenient maintenance and inspection. Using recently developed Susol VCB for almost unnecessary maintenance and inspection. Low voltage compartment provides enough space to test and change the internal wiring easily, and the wiring duct at the top of it is made of steel material. Independent bus compartment structured not to affect any accident to adjacent panels. 100% 50% 20% 10% 5% 85% of accidents preventable through diagnosis and maintenance 25.8% 22% 18.4% 15.8% 8.6% 7% Equipment instability Aged deterioration Poor maintenance Contact with foreign objects Negligent operating Other Digital type switchgear capable of digital data link Digital Protection & Monitoring Device, GIPAM developed by LSIS is adopt for establishing convenient and reliable power protection and monitoring system, and for Digital data link with remote monitoring and control system. X GIPAM separate type touch screen applied X GIPAM GIPAM- GIPAM-2200 I13

Solution Power Series Ratings 7.2kV Metal Clad Switchgear Specification Section Contents μs Model Solution Power S7 / V7 Rated voltage (kv) 7.2 Rated frequency (Hz) 50/60 Rated power frequency withstand voltage 20 (kv/1min) Rated lighting impulse withstand voltage 60 (kv[1.2 50 ]) Rated short-time withstand current (ka/s) 25/3 40/3 50/3 Degree of protection IP4X IP4X IP4X Internal arc withstand current (ka/s) 25/1 40/0.1 - Rated current (A) 630/1250/ 1250//3150 4000 Size (mm) Wide 600 650(850) 1050 Height 2250 2250 2250 Depth 1800 1900 2100 Certification KERI KERI KERI VCB Model Susol Pro-MEC Susol Standard IEC 62271-200 Note) 1. Solution Power V Series : Pro-MEC VCB installed. 2. Solution Power S Series : Susol VCB installed. 3. The number of the size in ( ) is for 3150A rating. 12kV Metal Clad Switchgear Specification Section Contents μs Model Solution Power S12 / V12 Rated voltage (kv) 12 Rated frequency (Hz) 50/60 Rated power frequency withstand voltage 28 (kv/1min) Rated lighting impulse withstand voltage 75 (kv[1.2 50 ]) Rated short-time withstand current (ka/s) 25/3 40/3 40/3 50/3 50/3 Degree of protection IP4X IP4X IP4X IP4X IP4X Internal arc withstand current (ka/s) 25/1 40/1-50/0.5 - Rated current (A) 630/1250/ 1250/2500/ 3150 4000 1250/2500 4000 Size (mm) Wide 600 650(850) 1050 850 1050 Height 2250 2250 2250 2250 2250 Depth 1800 1900 2100 1900 2100 Certification KERI/KEMA KERI/KEMA KERI/CESI KERI/CESI KERI/KEMA VCB Model Susol Pro-MEC Susol Pro-MEC Susol Standard IEC 62271-200 Note) 1. Solution Power V Series : Pro-MEC VCB installed. 2. Solution Power S Series : Susol VCB installed. 3. The number of the size in ( ) is for 3150A rating. 14I

17.5kV Metal Clad Switchgear Specification Section Contents Model Solution Power S17 / V17 Rated voltage (kv) 17.5 Rated frequency (Hz) 50/60 Rated power frequency withstand voltage (kv/1min) 38 Rated lighting impulse withstand voltage (kv[1.2 50μs]) 95 Rated short-time withstand current (ka/s) 25/3 40/3 Degree of protection IP4X IP3X Internal arc withstand current (ka/s) 25/1 40/0.1 Rated current (A) 630/1250/ 1250/3150 Size (mm) Wide 600 800(950) Height 2250 2250 Depth 1800 1900 Certification KERI/KEMA KERI/KEMA VCB Model Susol Pro-MEC Standard IEC 62271-200 Note) 1. Solution Power V Series : Pro-MEC VCB installed. 2. Solution Power S Series : Susol VCB installed. 3. The number of the size in ( ) is for 3150A rating. 24kV Metal Clad Switchgear Specification Section Model Solution Power S24 / V24 Rated voltage (kv) 24 Rated frequency (Hz) 50/60 Rated power frequency withstand voltage (kv/1min) 50 Rated lighting impulse withstand voltage (kv[1.2 50μs]) 125 Rated short-time withstand current (ka/s) 25/3 Degree of protection IP4X Internal arc withstand current (ka/s) 25/1 Rated current (A) 630/1250 2500 Size (mm) Wide 800 1000 1000 Height 2250 2250 2250 Depth 1800 1800 Certification KERI VCB Model Pro-MEC Pro-MEC Susol Standard IEC 62271-200 Note) 1. Solution Power V Series : Pro-MEC VCB installed. 2. Solution Power S Series : Susol VCB installed. 36kV Metal Clad Switchgear Specification Contents Section Contents Model Solution Power S36 Rated voltage (kv) 36 Rated frequency (Hz) 50/60 Rated power frequency withstand voltage (kv/1min) 70 Rated lighting impulse withstand voltage (kv[1.2 50μs]) 170 Rated short-time withstand current (ka/s) 25, 31.5, 40/3 Degree of protection IP4X Internal arc withstand current (ka/s) 40/1 Rated current (A) 1250//3150 Size (mm) Wide 1200 Height 2250 Depth 2600 Certification KERI/KEMA VCB Model Susol Standard IEC 62271-200 I 15

Solution Power Series Structures and dimensions R R S S T H T D W Low voltage compartment C.B. compartment Cable compartment V.T. compartment 300 15 110 150 140 40 W 550 50 40 BusBar compartment 65 d-130 D Base detail 16I 65

Ventilation Cover Bus Compartment Independent bus compartment structured not to affect any accident to adjacent panels. Low Voltage Compartment Enough space to test and change the internal wiring easily. Wiring duct for panel connection at the top is made of steel. Earthing Switch Device to discharge the load side current in the position of Test and Drawout to ensure the safe maintenance CB Compartment Can be drawn in and out C.B. without opening the door. Viewing window for C.B. inspection Solid structure with hinge and locker Metal shutter and shutter padlock IP cover on the face of C.B Cable compartment Sufficient spaces for wiring Insulation cap for the dielectric of Earthing switch Bottom incoming and outgoing (Top incoming and outgoing not available) I17

Solution Power Series Accessories and apparatuses Optional accessories for C.B. Compartment Shutter Padlock The hole to lock the shutters (load and line side) in close position, to increase the safety during the maintenance of a VCB draw-out position. Connector for Auxiliary circuits When the C.B. is service position, jack terminal can not be removed. Interlocking device between door and C.B. When the C.B. is service position, customer can not open the door without releasing the interlock key. Earthing Switch Padlock Prevent the accident in case of carelessness earthing switch operation. The locking of the earthing switch is available when the switch is in 'OFF' position. Emergency trip device C.B. can be tripped by trip device without opening the door. Inspection window Viewing window permits view of the status of the breaker through the closed door. Draw-in and out device C.B. can be drawn-in and out with the door closed. Mechanical position indicator Indicate the service and test position of C.B. VCB Position Padlock The hole prevent the draw-in and out of a VCB from the present position('run' or 'Test'). 18I

Vacuum circuit breaker LS Susol VCB is user-friendly to give more convenience and safety by providing high speed interrupting time (3cycles), adopting the rapid auto reclosing method, and having wide range of accessories. CB Compartment Option Mechanically Operated Cell switch (MOC) Auxiliary switch, which is mechanically operated in 'Run' position, indicates 'ON' or 'OFF' condition of the breaker. Earthing Switch Position Switch The auxiliary switch (5a5b) to indicate 'ON' or 'OFF' of the earthing switch. Truck Operated Cell Switch (TOC) The auxiliary switch (3a4b), which is operated when the breaker comes to 'Run' position. Earthing Locking Coil To prevent the accident through carelessness earthing switch operation, the earthing switch can be changed to 'ON' position after releasing the lock by energizing the coils. Code Plate (Miss insertion prevention) To prevent the insertion of a breaker to a cradle If their ratings do not match. I19

Solution Power Series Accessories and apparatuses Current Transformer In Door Insulator Type Current Transformer DCI-204A(W) Max system voltage 7.2KV to 25.8KV The primary and secondary coil are wounded on high permeability directional core with short magnetic path. The assembly of primary, secondary and ground is entirely encapsulated with silica-filled epoxy resin. This ensures superior electrical characteristics and mechanical strength Type Maker Rated Voltage (kv) Rated Primary Current (A) Rated Secondary Current (A) Rated Output (VA) Rated Insulation Power Frequency (kv/1min) Level Impulse (kv/1.2 50μs ) Rated Short Time Current (ka) Contact us for other specification. DCI-204A(W)DIC-205A(W) TPU 60.23 Dongwoo ABB 24 20 to 2,000 1,5 40 50 125 25 2-M12 TAP (DP:20mm) 28 162.5 4-M12 TAP (DP:20mm) 28 2-M12 TAP (DP:20mm) 4-M12 TAP (DP:20mm) 160 200 28 12.5 162.5 350 28 28 100 1250A to A (Primary current) 112 320 370 50 28 162.5 28 100 200 220 28 150 162.5 355 17.5 28 1250A to A (Primary current) 122 320 370 50 28 150 EARTH TERMINAL (M6) EARTH TERMINAL (M6) SEC. TERMINAL(M6) SEC. TERMINAL(M6) 20I

Voltage Transformer In Door Type Voltage Transformer Compact and concentrated fuse holder of Y24F can be easily applied to the VTS compartment Mounting type Compact and epoxy molded for superior insulation and maintenance free μs Type Maker Rated Voltage (kv) Rated Voltage Ratio (V) Rated Output (VA) Rated Insulation Power Frequency (kv/1min) Level Impulse (kv/1.2 50 ) Rated Voltage Factor Contact us for other specification. Y24F/a14 (Equipped with a fuse) SADTEM (France) 24 22,900/ 3 / 190/ 3 or 110/ 3 100 50 125 1.9 8h 605 138 A H1 240 NAMEPLATE 599 240 25 304.5 130 108 2 285 325 DIA 11 I21

Solution Power Series Arrangement (for general application) (Withdrawable VT) Section view Diagram Note) Panels except Incoming panel and Feeder panel to be applied those of a general switchgear. 22I

(Withdrawable VT) Section view Diagram I23

Safety Instructions For your safety, please read user's manual thoroughly before operating. Contact the nearest authorized service facility for examination, repair, or adjustment. Please contact a qualified service technician when you need maintenance. Do not disassemble or repair by yourself! Any maintenance and inspection shall be performed by the personnel having expertise concerned. c 2011.12 LSIS Co.,Ltd. All rights reserved. www.lsis.com HEAD OFFICE Korea Gyeonggi-do Anyang-si dongan-gu LS-ro 127 (Hogye-dong) Tel. (82-2)2034-4931, 4943, 4946 Fax. (82-2)2034-4882 CHEONG-JU PLANT Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, 361-720, Korea Specifications in this catalog are subject to change without notice due to continuous product development and improvement. Global Network LSIS USA Inc. Chicago, America Address: Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America Tel: 847-941-8240 Fax: 847-941-8259 e-mail: seungheonc@lsis.com LSIS (Middle East) FZE Dubai, U.A.E. Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab Emirates Tel: 971 4 886 5360 Fax: 971 4 886 5361 e mail: hschoib@lsis com LSIS Europe B.V. Schiphol-Rijk, Netherlands Address: 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands Tel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: junshickp@lsis.biz LSIS-VINA Co., Ltd. Hanoi, Vietnam Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: sjbaik@lsis.biz LSIS-VINA Co., Ltd. Hochiminh, Vietnam Address: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, Vietnam Tel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: hjchoid@lsis.biz LSIS Gurgaon Office Gurgaon, India Address: 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India Tel: +0091-124-493-0070 Fax: 91-1244-930-066 e-mail: hwyim@lsis.biz LSIS Japan Co., Ltd. Tokyo, Japan Address: Toykokurakubu Bldg. 13th floor, 3-2-6, Kasumigaseki, Chiyoda-ku, Tokyo, 100-0013 Japan TEL:+81-3-6268-8241 FAX:+81-3-6268-8240 e-mail: jschuna@lsis.biz LSIS Shanghai Office Shanghai, China Address: Room 32 floors of the Great Wall Building, No. 3000 North Zhongshan Road, Putuo District, Shanghai, China Tel: 86-21-5237-9977 Fax: 89-21-5237-7189 e-mail: mkleea@lsis.com LSIS Beijing Office Beijing, China Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District, Beijing 100013, P.R. China Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: sunmj@lsis.com.cn LSIS Guangzhou Office Guangzhou, China Address: Room 1403, 14/F, New Poly Tower, No.2 Zhongshan Liu Road, Guangzhou 510180, P.R. China Tel: 020-8326-6754 Fax: 020-8326-6287 e-mail: chenxs@lsis.com.cn LSIS Chengdu Office Chengdu, China Address: Room 1701 17Floor, huamin hanjun internationnal Building, No1 Fuxing Road Chengdu, 610016, P.R. China Tel: 86-28-8670-3201 Fax: 86-28-8670-3203 e-mail: yangcf@lsis.com.cn LSIS Qingdao Office Qingdao, China Address: Room 2001,20/F,7B40, Galaxy Building, No.29 Shandong Road, Shinan District, Qingdao 266071, P.R. China Tel: 86-532-8501-6058 Fax: 86-532-8501-6057 e-mail: htroh@lsis.biz LSIS (Wuxi) Co., Ltd. Wuxi, China Address: 102-A, National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: wangzy@lsis.com.cn Dalian LSIS Co., Ltd. Dalian, China Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: tangyh@lsis.com.cn 2014. 02 Medium Voltage Metal Clad Switchgear (E) 2011. 12/(04) 2014. 02 Printed in Korea STAFF